Tender For Installation Of Different Diameter Sluice Valves And Other Allied Works To Regulate And Controlling The Flow Of Water In The Pipe Line Network Of Secondary Grid For Joynagar-Ii Block Under South-24 Pgns W/S Divn-I, Phe Dte.
Tender Overview
Project Description
Tender for Installation Of Different Diameter Sluice Valves And Other Allied Works To Regulate And Controlling The Flow Of Water In The Pipe Line Network Of Secondary Grid For Joynagar-Ii Block Under South-24 Pgns W/S Divn-I, Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches or drains ,in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoil within a lead of 75 metre as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 2 | (a) Depth of excavation not exceeding 1500 mm. |
| 3 | (b) Depth of excavation for additional depth beyond1,500 mm. and upto 3,000 mm. but not requiringshoring. |
| 4 | Filling in foundation or plinth by Silver Sand in layers not exceeding 150mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. |
| 5 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 6 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 7 | Hire and labour charges for shuttering with centering and necessary staging upto 4 mtr. using approved stoutprops and thick hard wood planks of approve thickness with required barching for concrete slab, beams, columns, lintels, curved or straight including fitting, fixing & striking out after completion of works (Upto roof of ground floor) |
| 8 | a) Steel shuttering of 9 to12mm thick approved quality ply board shuttering in any concrete work |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m i) Tor steel/Mild Steel I. SAIL/ TATA/RINL |
| 10 | Distance from Ex-outlet to work site 10 km |
| 11 | Ordinary Cement Concrete (mix 3:1.5:1) with graded stone chips (20mm down) excluding shuttering and reinforcement. If any, in ground floor, as per IS 456-2000. |
| 12 | a) Pakur Variety |
| 13 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm including watering and ramming etc. layer by layer complete. |
| 14 | With earth obtained from excavation of foundation. |
| 15 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. |
| 16 | In ground floor including roof (a) upto 150 mm. thick |
| 17 | Supply of M.S. Flange (Slipper type) as per IS:6392 TABLE Thickness 20mm - 22mm. |
| 18 | i) 400 mm dia (NB) |
| 19 | ii) 350 mm dia (NB) |
| 20 | iii) 300 mm dia (NB) |
| 21 | iv) 250 mm dia (NB) |
| 22 | v) 200 mm dia (NB) |
| 23 | vi) 150 mm dia (NB) |
| 24 | Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW rate). |
| 25 | i) 600 mm dia |
| 26 | ii) 400 mm dia |
| 27 | iii) 350 mm dia |
| 28 | iv) 300 mm dia |
| 29 | v) 250 mm dia |
| 30 | vi) 200 mm dia |
| 31 | vii) 150 mm dia |
| 32 | Cutting to requisite length or shape departmental R.S. joists, channels, angles, tees, plates etc. (Payment to be made on area of cut surface) |
| 33 | Welding in M.S. structural work with gas or electric:(a) Continuous weld. |
| 34 | Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] |
| 35 | i) 80 mm to 150 mm dia pipe |
| 36 | ii) 200 mm dia pipe |
| 37 | iii) 250 mm to350 mm dia pipe |
| 38 | iv) 400 mm to 450 mm dia pipe |
| 39 | Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). |
| 40 | For CI/DI/MS pipe |
| 41 | i) 600 mm dia |
| 42 | ii) 450 mm dia |
| 43 | iii) 350 mm dia |
| 44 | iv) 300 mm dia |
| 45 | v) 250 mm dia |
| 46 | vi) 200 mm dia |
| 47 | vii) 150 mm dia |
| 48 | Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). |
| 49 | For CI/DI/MS pipe |
| 50 | i) 600 mm dia |
| 51 | ii) 450 mm dia |
| 52 | iii) 350 mm dia |
| 53 | iv) 300 mm dia |
| 54 | v) 250 mm dia |
| 55 | vi) 200 mm dia |
| 56 | vii) 150 mm dia |
| 57 | Making lighting arrangement for continuation work during night including all charges (Applicable exclusively for emergency situation and as per direction of EIC.) |
| 58 | Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC) |
| 59 | Hire charges of moveable crane (capacity 10MT) including operator, helper, fuel, lubricants etc. for loading/ unloading/ placing of various materials / accessories of water supply works as per direction of E.I.C.(For 8 Hrs of working per day)[ For lowering and placing of different dia meter sluice valves] |
| 60 | Supply of M.S. Flange (Slipper type) as per IS:6392 TABLE Thickness 24mm |
| 61 | 600 mm dia (NB) |
| 62 | Supplying & fabricating of different diameter M.S. Pipes as per specification (IS 3589:2001) and direction of E.I.C. |
| 63 | i) 610 mm MS pipe 12.5 mm th |
| 64 | ii) 406.4 mm MS pipe 8.8 mm th |
| 65 | iii) 355.6 mm MS pipe 7.7 mm th |
| 66 | iv) 323.9 mm MS pipe 7.1 mm th |
| 67 | v) 273 mm MS pipe 6.3 mm th |
| 68 | vi) 219.1 mm MS pipe 6.3 mm th |
| 69 | vii) 168.3 mm MS pipe 4.5 mm th |
| 70 | Supply and delivery of MS Machine End to be delivered at site inclusive of all duties, taxes, charges and cost of transportation, loading & unloading and stacking all complete and lifting at destination point all complete as per the direction of EIC. |
| 71 | i) 600 mm dia |
| 72 | ii) 400 mm dia |
| 73 | iii) 350 mm dia |
| 74 | iv) 300 mm dia |
| 75 | v) 250 mm dia |
| 76 | vi) 200 mm dia |
| 77 | vii) 150 mm dia |
| 78 | Add GST @ 18% on all items Except Item No. 19, 20, 21 & 22 |
| 79 | Add CESS @ 1% on all items except item no. 19, 20, 21 & 22 including GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender