Bids Are invited for Radiation Hardened Accelerometers
Tender Overview
Project Description
Bids Are invited for Radiation Hardened Accelerometers Charge Output, High Temperature, Radiation Hardened Accelerometers. , Hardline, Mi Cable - Between 10-32 Plug Of Accelerometer To 10-32 Plug Of In-Line Charge Lifier Input, With Length Of 3 Meter. , In-Line Charge Converter For Accelerometer. , Low-Noise Coaxial Cable For Radiation Hardened Accelerometer With Blue Tfe Jacket With Length Of 22 Meter Or 75 Feet. , Tri-Axial Mounting Block Along With The Studs , Pressure Sensors , Low-Noise, Coaxial, Tfe Cable With Stranded Conductor, With 10-Ft Length And 10-32 Plug On Both Ends , In-Line Charge Converters For Pressure Sensor , Low-Noise, Coaxial, With Minimum 30-Ft Length And 10-32 Plug To Bnc Plug Ends , Data Acquisition Unit With Software , Data Analysis - Processing Unit- Laptop - Charge Output, High Temperature, Radiation Hardened Accelerometers. - Charge Output, High Temperature, Radiation Hardened Accelerometers, As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.1 , Hardline, Mi Cable - Between 10-32 Plug Of Accelerometer To 10-32 Plug Of In-Line Charge Lifier Input, With Length Of 3 Meter. - Hardline, Mi Cable (Between 10-32 Plug Of Accelerometer To 10-32 Plug Of In-Line Charge Lifier Input) With Length Of 3 Meter As Per Technical Specification No. Pp-E-00162, Clause No.5.2.2 , In-Line Charge Converter For Accelerometer. - In-Line Charge Converter For Accelerometer As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.3 , Low-Noise Coaxial Cable For Radiation Hardened Accelerometer With Blue Tfe Jacket With Length Of 22 Meter Or 75 Feet. - Low-Noise Coaxial Cable For Radiation Hardened Accelerometer With Blue Tfe Jacket With Length Of 22 Meter Or 75 Feet As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.4 , Tri-Axial Mounting Block Along With The Studs - Tri-Axial Mounting Block Along With The Studs As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.5 , Pressure Sensors - Pressure Sensors As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.6 , Low-Noise, Coaxial, Tfe Cable With Stranded Conductor, With 10-Ft Length And 10-32 Plug On Both Ends - Low-Noise, Coaxial, Tfe Cable With Stranded Conductor, With 10-Ft Length And 10-32 Plug On Both Ends, As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.8 , In-Line Charge Converters For Pressure Sensor - In-Line Charge Converters For Pressure Sensor As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.7 , Low-Noise, Coaxial, With Minimum 30-Ft Length And 10-32 Plug To Bnc Plug Ends - Low-Noise, Coaxial, With Minimum 30-Ft Length And10-32 Plug To Bnc Plug Ends, As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.8 , Data Acquisition Unit With Software - Data Acquisition Unit With Software As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.9 And 5.2.10 , Data Analysis - Processing Unit- Laptop - Data Analysis/ Processing Unit -Laptop As Per Technical Specification No. Pp-E-00162, Clause No. 5.2.11
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Charge output, high temperature, radiation hardened accelerometers. | Charge output, high temperature, radiation hardened accelerometers, as per technical specification no. PP-E-00162, clause No. 5.2.1 |
| 2 | Hardline, MI Cable - between 10-32 plug of accelerometer to 10-32 plug of In-line charge amplifier input, with length of 3 meter. | Hardline, MI Cable (between 10-32 plug of accelerometer to 10-32 plug of In-line charge amplifier input) with length of 3 meter as per technical specification no. PP-E-00162, clause No.5.2.2 |
| 3 | In-line charge converter for accelerometer. | In-line charge converter for accelerometer as per technical specification no. PP-E-00162, clause No. 5.2.3 |
| 4 | Low-noise coaxial cable for Radiation hardened Accelerometer with blue TFE jacket with length of 22 meter or 75 feet. | Low-noise coaxial cable for Radiation hardened Accelerometer with blue TFE jacket with length of 22 meter or 75 feet as per technical specification no. PP-E-00162, clause No. 5.2.4 |
| 5 | Tri-axial Mounting block along with the studs | Tri-axial Mounting block along with the studs as per technical specification no. PP-E-00162, clause No. 5.2.5 |
| 6 | Pressure sensors | Pressure sensors as per technical specification no. PP-E-00162, clause No. 5.2.6 |
| 7 | Low-noise, coaxial, TFE cable with stranded conductor, with 10-ft length and 10-32 plug on both ends | Low-noise, coaxial, TFE cable with stranded conductor, with 10-ft length and 10-32 plug on both ends, as per technical specification no. PP-E-00162, clause No. 5.2.8 |
| 8 | In-line charge converters for pressure sensor | In-line charge converters for pressure sensor as per technical specification no. PP-E-00162, clause No. 5.2.7 |
| 9 | Low-noise, coaxial, with minimum 30-ft length and 10-32 plug to BNC plug ends | Low-noise, coaxial, with minimum 30-ft length and10-32 plug to BNC plug ends, as per technical specification no. PP-E-00162, clause No. 5.2.8 |
| 10 | Data Acquisition Unit with Software | Data Acquisition Unit with Software as per technical specification no. PP-E-00162, clause No. 5.2.9 and 5.2.10 |
| 11 | Data Analysis - Processing Unit- Laptop | Data Analysis/ Processing Unit -Laptop as per technical specification no. PP-E-00162, clause No. 5.2.11 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 35 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 36 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender