Tender For Running Maintenance Of Different M.I. Schemes Under Durgachowmuhani Block & Kamalpur Nagar Panchayet During The Year 2026-27/S.H:- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc.
Tender Overview
Project Description
Tender for Running Maintenance Of Different M.I. Schemes Under Durgachowmuhani Block & Kamalpur Nagar Panchayet During The Year 2026-27/S.H:- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc.
BOQ
| Sl. No. | Item Description |
| 1 | Dismentaling of pump for over hauiling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineerin- Charge. |
| 2 | For LI |
| 3 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality. |
| 4 | 150 mmφ |
| 5 | 190 mmφ |
| 6 | Providing & fitting fixing coupling nuts & bolts (all Size) of approved quality. |
| 7 | For LI |
| 8 | Providing & fitting fixing coupling rubber bush (All Size) of approved quality. |
| 9 | For LI |
| 10 | Providing & fitting fixing coupling star bush (All Size) of approved quality. |
| 11 | 150 mmφ |
| 12 | 190 mmφ |
| 13 | Providing & fitting fixing Pump Shaft of approved quality. |
| 14 | Providing & fitting fixing Shaft sleeve bush of approved quality. |
| 15 | For LICast iron (CI) |
| 16 | Providing & fitting fixing Shaft sleeve nut of approved quality. |
| 17 | For LICast iron (CI) |
| 18 | Providing & fitting fixing C.I. Impeller of approved quality for Horizontal pump |
| 19 | Providing & fitting fixing coupling/ impeller Key of approved quality. |
| 20 | Providing & fitting fixing Casing ring of approved quality |
| 21 | Providing & fitting fixing C.I. gland of approved quality |
| 22 | For LI |
| 23 | Providing & fitting fixing Gland nut / Stag nut 100 mm long for gland of approved quality. |
| 24 | For LI |
| 25 | Providing & fitting fixing Lantern Ring for pump of approved quality |
| 26 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling. |
| 27 | 6305 Ball bearing (TATA /SKF) |
| 28 | 6306 Ball bearing (TATA /SKF) |
| 29 | Supplying & fitting fixing of GI . bend of approved quality |
| 30 | 125 mm dia |
| 31 | 150 mm dia |
| 32 | Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-in-charge. |
| 33 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality. |
| 34 | 150 mm dia |
| 35 | 125 mm dia |
| 36 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality. |
| 37 | 150 mm dia |
| 38 | 125 mm dia |
| 39 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality. |
| 40 | 150 mm dia |
| 41 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality |
| 42 | 150 mm dia |
| 43 | Providing & fitting fixing C.I tail piece of approved quality at site of work. |
| 44 | 150 mm dia |
| 45 | 125 mm dia |
| 46 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality. |
| 47 | 150 mm dia |
| 48 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality. |
| 49 | C.I foot valve weight |
| 50 | C.I foot valve ring |
| 51 | C.I foot valve net |
| 52 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. |
| 53 | Dismantaling of horizontal pump and motor of 20/25 HP from the base and carrying the pump set to the nearest workshop for repairing the body thread of stag nut and carrying the same to the scheme and fitting fixing the pump set as before as per direction of the Engineer-in-charge. |
| 54 | Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm ɸ |
| 55 | Dismentaling of G.I bend including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm ɸ |
| 56 | Dismentalling of motor for vernishing, heating etc. complete in/c reinstallation and trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge |
| 57 | Supplying and greasing/applying of grease in wheel bearing complete as per direction of Engineer-in-charge. |
| 58 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge. |
| 59 | Excavating trenches required width for pipes, cables, etc. including excavation for sockets, collars etc and dressing of sides ramming of bottoms , depth minimum 0.90m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil within a lead of 50m (For G.I and C.I pipes)A) All kinds of soil.i) Pipes, cables etc exceeding 75 mm dia but not exceeding 150 mm |
| 60 | Providing and fixing G.I. pipes medium class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer- in - charge.A. External worki. 40 mm dia. nominal bore |
| 61 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. |
| 62 | 125 mm dia. nominal bore |
| 63 | 150 mm dia. nominal bore |
| 64 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in- Charge. |
| 65 | 150 mm dia nominal bore(medium) |
| 66 | 125 mm dia nominal bore(medium) |
| 67 | Supplying & fitting fixing manually operated oil immerged starter of approved quality.a) 30 Hp Osco/BCH Make |
| 68 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality.SMI-144, Range 0-400 to 0-500 |
| 69 | Supplying and fitting fixing AC Ammeter (Moving Iron) on the panel board of approved quality.SMI-144, Range 0-10A |
| 70 | Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality. |
| 71 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.7/16 Copper Wire |
| 72 | Supplying & fitting fixing kit cut for main & sub-main swich (Male & female) as per direction of the Engineer in Charge. |
| 73 | 63 Amps main switch |
| 74 | 200 Amps main switch |
| 75 | Supplying and fitting fixing of spare contact kit ,type ML 1.5 suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge. |
| 76 | Supplying and fitting fixing of spare coil, type ML 1.5 range suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge. |
| 77 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:- |
| 78 | a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 79 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: |
| 80 | a) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 81 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- |
| 82 | Above 300mm length.- |
| 83 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 84 | 125 mm dia.A. PN - 1.6 |
| 85 | 150 mm dia.A. PN - 1.6 |
| 86 | Labour charge for fitting fixing of CI sluice valve class-I with cap complete by providing nuts and bolts, 3mm thick rubber insertion etc.(Tail piece if required will be paid separately) (only C.I sluice valve class-I with will be supplied by deptt. at free of cost) |
| 87 | Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in -charge. |
| 88 | charges for fitting fixing of brass fullway valve with handle (issued from department free of cost) in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in - charge. |
| 89 | 40mm dia |
| 90 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg.- In - Charge. |
| 91 | Stand finger |
| 92 | Gola finger |
| 93 | CT Coil |
| 94 | Magnet Coil |
| 95 | Circuit board for Osco starter of Backelite make |
| 96 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality. |
| 97 | 125 mm dia |
| 98 | 150 mm dia |
| 99 | Dismentling of pannel board by disconnection of all electrical equipments & stacking of materials & return the same to Sub- Divisional store as per direction of the Engineer-in-charge. |
| 100 | Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge. |
| 101 | Providing and installation of Copper Strips of 200 Amps busbar by replacing the damaged one with necessary nuts and bolts etc. as perdirection of Engg.- In - Charge. |
| 102 | Labour charge for dismantling,turning making alignment of pump motor shaft for suitable fitting coupling,bearing,sleeve bush etc as per direction of the Engg-in-Charge. |
| 103 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.40 mm dia |
| 104 | Supplying & fitting fixing of spare parts for 20/25 HP Horizontal motor. |
| 105 | Motor fan |
| 106 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge |
| 107 | Current range 63 Amps. |
| 108 | Current range 200 Amps Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender