Tender For Repair And Maintenance Of 33/11 Kv Main Receiving Station (Mrs) Including Connected Works Under Ge Ima Dehradun
Tender Value
35 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
12 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of 33/11 Kv Main Receiving Station (Mrs) Including Connected Works Under Ge Ima Dehradun
BOQ
| Sl. No. | Item Description |
| 1 | M&L for servicing 33 KV yard structure complete including replacement of unserviceable jumper, sleeves, vice type connnector, nut bolt and washers, connecting lugs/thimble, knife contact, applying petroleum jelly to the moving as well as fixed contacts, tightining all the connection for its smoth functioning preparing old painted surface of this structure such as poles, cross arms, bracing supports, clamp and back plate complete painting of one coat of anti corrosive weather proof heat resistant aluminium paints and providing Red/Yellow and Black paint including writing SM/MES No or all ther direction/Marker/Code etc with grey/Black paint on boards etc not less then 40 mm hight 7 - 10 mm thick all as directed at site by Engineer-in-charge. Note: No extra payment will made for the spares required to keep the yard structure in satisfactory functional state through out contract period other then given in schedule complete all as directed. |
| 2 | Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying cable/taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Excavation in trenches not exc. 1.5 mtr wide and exc. 1.5 mtr but nexc.3.0mtr in depth for laying cable/taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil all as specified and directed. |
| 4 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft/lose soil after cable/pipes are laid and tested all as specified and directed. |
| 5 | Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all as specified and directed. |
| 6 | M&L for sand cushioning to under ground cables in trench and existing duct at MRS, thick before laying the cable, stretching and testing the cable all as specified and directed. Note:- Punned thickness of sand will be measured and paid. |
| 7 | M&L for un-reinforced precast concrete cable cover HV type I, flat size 300 mm X 180 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as specified and directed. |
| 8 | Supply, laying, jointing and testing of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 3 core 185 sq mm including taking out/down old existing unserviceable cable complete all as specified and directed. |
| 9 | Supply, laying, jointing and testing of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 3 core 150 sq mm including taking out/down old existing unserviceable cable complete all as specified and directed. |
| 10 | S&F of rotating type air break isolating switch horizontal mounting for triple pole, mechanically operated mounted on gang operated devices united on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps for 33000 volts all as specified and directed. |
| 11 | S&F of switches air break, gang operated triple pole with dropout fuse set 12 insulator, mechanically operated, mounted insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps 11000 volts complete including dismantling and taking down existing unserviceable GOD of any description complete all as specified and directed. |
| 12 | M&L for filtration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil upto 50KV at 2.5mm gap complete all as specified and directed. Note : (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge/JE (E/M).(b) The contractor shall ensure no wastage at transformer oil.(c) The contractor is solely responsible for any damage to the transformer/HT OCB during filtration operations. He is responsible for making good any damage to the transformer/HTOCB at his own cost without any extra cost to the department.(d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration.(e) Contractor will be fully responsible for shift the load of existing transformer to standby transformer before taking down for repair. |
| 13 | S&F for disc type insulator porcelain vitreous 145 mm height and 255 mm dia ball and socket type white brown or green with tension clamp for conductor working pressure 11000 volts complete all as specified and directed. |
| 14 | S&L for post insulator 22KV each in double stake, working pressure 33000 Volts grade suitable for 33KV Yard including nuts and bolts etc complete all as specified and directed. |
| 15 | Supply, filling and topping up transformer Oil in power transformer at MRS complete all as specified and directed. Note: (i) The transformer oil shall be type EHV confirming to IS 3357 of 1983.(ii) Mineral oil grade 'B' shall be used.(iii) The transformer oil should have a high dielectric strength not less than 60KV. (iv) Oil should be brought 209 ltrs sealed container complete all as specified and directed. |
| 16 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jonting material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and directed. |
| 17 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jonting material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed. |
| 18 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jonting material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and directed. |
| 19 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jonting material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mmcomplete all as specified and directed. |
| 20 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jonting material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and directed. |
| 21 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jonting material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mmcomplete all as specified and directed. |
| 22 | S&F for Danger notice plate of 1.6mm Thick mild steel sheet, vitreous enamelled white, with letters, figures and conventionals skull and bones in dignal red colour of 33 KV and fixed with MS clamp FI 25x3 mm, botls and nuts of approved size for HT 25x20 cm size. |
| 23 | S&F LT control cable copper armoured conductor PVC insulated and PVC sheathed round multicore cable 1100 volts grade including dismantling of existing cable of following cross sectional area sizes :- |
| 24 | Size of cable 2.5 Sq mm 2 Core |
| 25 | Size of cable 2.5 Sq mm 4 Core |
| 26 | Size of Cable 2.5 Sq mm 8 Core Please Enable Macros to View BoQ information |
| 27 | Size of Cable 2.5 Sq mm 8 Core Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender