Tender For Repair/Replacement Of Dg Sets, Amf Panels, Control Panels And Connected Allied Works At Nofra, Outlaying Area Under Ge (Nw) Nofra.

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
47.22 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
11 days left
EMD
94450
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Dg Sets, Amf Panels, Control Panels And Connected Allied Works At Nofra, Outlaying Area Under Ge (Nw) Nofra.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Sep-2026 Corrigendum date Terms and Conditions 12-Oct-2026

BOQ

Name of Work:- REPAIR/REPLACEMENT OF DG SETS, AMF PANELS, CONTROL PANELS AND CONNECTED ALLIED WORKS AT NOFRA, OUTLAYING AREA UNDER GE (NW) NOFRA.
Sl. No. Item Description
1A Check :M&L for monthly Inspection, maintenance and serviceing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed.
2Monthly Service :(a) Checking engine oil level and topping up as and when required. [Note : Oil shall be measured and paid separately.](b) Checking and adjusting the belt for tension and replacement of belt. [Note : Belt shall be measured and paid seperately](c) Checking of oil bath air cleaner level(d) Checking of exhaust system for leakage(e) Draining of sediment from fuel filter and fuel tank(f) Cleaning of air cleaner element(g) Checking engine alternator coupling, mounting bolts and alignment(h) Tightening all nuts, bolts, in altenator terminal block(j) Checking of alternator carbon brush and connections in alternator
3(k) Checking and tighting of all connection in DC control wiring.(l) Checking of all radiator rubber hose and replacement if required. [Note : Hose pipe shall be measured and paid separately](m) Checking and recording oil pressure, water and oil temperature(n) Checking anti vibration mounting and replacement if required. [Note : Anti vibration pad shall be measured and paid separately(o) Checking throttle linkage(p) Checking battery for cell test, electrolyte level, gravity and topping up to required level(q) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit.(r) Checking of AMF panel, all electrical connections etc.(s) Checking of earthing resistance(t) Cleaning of vegitation around the DG set up to 1.5 mtr area.
4125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Duxbury
5125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Aditi/Ahilya
6125 KVA Capacity, Make : Kirloskar, Model 6R1080TA G1, Location : Vandana/Vishaka
7125 KVA Capacity, Make : Greaves, Model 4G11TAG26, Location : Meena STP
8125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : Vidya/Vijaya
9125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : IMSC
10125 KVA Capacity, Make : Kirloskar, Model 4K1080ETA4G1, Location : Jhelum
11110 KVA Capacity, Make : Crompton Greaves, Model : 12050610540, Location : Sasson dock
12100 KVA Capacity, Make : Greaves, Model 4G11TAG25, Location : Meena STP
13100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
14100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
1582.5 KVA Capacity, Make : Koel green, Model : AL4CT1DG3, Location : Vatsala (RO plant)
1682.5 KVA Capacity, Make : Ashok Leyland, Model AL4CTIDG3, Location : IMSC (Mobile)
1762.5 KVA Capacity, Make : Kirloskar, Model 4R810TA G1, Location : Vatsala
1862.5 KVA Capacity, Make : Kirloskar, Model 4R810TAG1, Location : WNC 'o' Mess
1962.5 KVA Capacity, Make : Cummins, Model 4BTAA3.3G11, Location : Chenab
2025 KVA Capacity, Make : Kirloskar, Model : F102/2014-07-E1 , Location : NT Pool
21B' Check once in Six month OR 250 Hrs running of DG set whichever is EarlierMaterial and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :-
22Repeat the activities of 'Á' CheckReplacment of of lubricant oil. (Note:- Lub Oil are Paid separately.)Replacing lubricant oil filter element with 'O' ringReplacing fuel filter elementReplacing coolant. (Note:- coolant are Paid separately.)Replacing Governer oilNotes :B Check kit, coolant shall be measured and paid separately under relevent items Lubricant oil shall be measured and paid separately under relevent item.
23125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Duxbury
24125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Aditi/Ahilya
25125 KVA Capacity, Make : Kirloskar, Model 6R1080TA G1, Location : Vandana/Vishaka
26125 KVA Capacity, Make : Greaves, Model 4G11TAG26, Location : Meena STP
27125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : Vidya/Vijaya
28125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : IMSC
29125 KVA Capacity, Make : Kirloskar, Model 4K1080ETA4G1, Location : Jhelum
30110 KVA Capacity, Make : Crompton Greaves, Model : 12050610540, Location : Sasoon dock
31100 KVA Capacity, Make : Greaves, Model 4G11TAG25, Location : Meena STP
32100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
33100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
3482.5 KVA Capacity, Make : Koel green, Model : AL4CT1DG3, Location : Vatsala (RO plant)
3582.5 KVA Capacity, Make : Ashok Leyland, Model AL4CTIDG3, Location : IMSC (Mobile)
3662.5 KVA Capacity, Make : Kirloskar, Model 4R810TA G1, Location : Vatsala
3762.5 KVA Capacity, Make : Kirloskar, Model 4R810TAG1, Location : WNC 'o' Mess
3862.5 KVA Capacity, Make : Cummins, Model 4BTAA3.3G11, Location : Chenab
3925 KVA Capacity, Make : Kirloskar, Model : F102/2014-07-E1 , Location : NT Pool
40Supply only B check kit for DG set of following capacities :-Note : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element
41125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Duxbury
42125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Aditi/Ahilya
43125 KVA Capacity, Make : Kirloskar, Model 6R1080TA G1, Location : Vandana/Vishaka
44125 KVA Capacity, Make : Greaves, Model 4G11TAG26, Location : Meena STP
45125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : Vidya/Vijaya
46125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : IMSC
47125 KVA Capacity, Make : Kirloskar, Model 4K1080ETA4G1, Location : Jhelum
48110 KVA Capacity, Make : Kirloskar, Model : 12050610540, Location : Sasson dock
49100 KVA Capacity, Make : Greaves, Model 4G11TAG25, Location : Meena STP
50100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
51100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
5282.5 KVA Capacity, Make : Koel green, Model : AL4CT1DG3, Location : Vatsala (RO plant)
5382.5 KVA Capacity, Make : Ashok Leyland, Model: AL4CTIDG3, Location : IMSC (Mobile)
5462.5 KVA Capacity, Make : Kirloskar, Model 4R810TA G1, Location : Vatsala
5562.5 KVA Capacity, Make : Kirloskar, Model 4R810TAG1, Location : WNC 'o' Mess
5662.5 KVA Capacity, Make : Cummins, Model 4BTAA3.3G11, Location : Chenab
5725 KVA Capacity, Make : Kirloskar, Model : F102/2014-07-E1 , Location : NT Pool
58Supply & Replacement of Air Fillter Assembly for DG set of following capacities :-
59125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Duxbury
60125 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : Aditi/Ahilya
61125 KVA Capacity, Make : Kirloskar, Model 6R1080TA G1, Location : Vandana/Vishaka
62125 KVA Capacity, Make : Greaves, Model 4G11TAG26, Location : Meena STP
63125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : Vidya/Vijaya
64125 KVA Capacity, Make : Kirloskar, Model 4K1080TA G2, Location : IMSC
65125 KVA Capacity, Make : Kirloskar, Model 4K1080ETA4G1, Location : Jhelum
66110 KVA Capacity, Make : Kirloskar, Model : 12050610540, Location : Sasson dock
67100 KVA Capacity, Make : Greaves, Model 4G11TAG25, Location : Meena STP
68100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
69100 KVA Capacity, Make : Kirloskar, Model 6R1080TA, Location : INS Shikra
7082.5 KVA Capacity, Make : Koel green, Model : AL4CT1DG3, Location : Vatsala (RO plant)
7182.5 KVA Capacity, Make : Ashok Leyland, Model: AL4CTIDG3, Location : IMSC (Mobile)
7262.5 KVA Capacity, Make : Kirloskar, Model 4R810TA G1, Location : Vatsala
7362.5 KVA Capacity, Make : Kirloskar, Model 4R810TAG1, Location : WNC 'o' Mess
7462.5 KVA Capacity, Make : Cummins, Model 4BTAA3.3G11, Location : Chenab
7525 KVA Capacity, Make : Kirloskar, Model : F102/2014-07-E1 , Location : NT Pool
76Supply only coolant, K cool super plus 50-50 Premix
77Supply only Battery water with electrolyte mix
78Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
79Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged.
80Material and labour for replacement of unserviceable battery 12 V, 150 AH with maintenance free battery 12 Volt initially charged.
81Material and labour for replacement of unserviceable battery 12 V, 90 AH with maintenance free battery 12 Volt initially charged.
82Material and labour for replacement of brass battery terminal suitable for lead acid, battery 12 V any AH
83Material and labour for replacement of battery Copper Cable 70 Sqmm Red including Copper Lugs
84Material and labour for replacement of battery Copper Cable 70 Sqmm Black including Copper Lugs.
85Taking out old unserviceable battery charger from the following DG sets replacemnt with the following battery charger of suitable capacity and checking the terminals including petroleum jelly and spray cleaning and getting test certificate to produce Engr-in-charge for the following capacities of DG sets all as specified and directed.
86Battery charger 12 volts 20 Amps capacity panel mounted suitable for 100/110/125 KVA DG set complete all as directed.
87Battery charger 12 volts 10 Amps capacity panel mounted suitable for 25/62.5/82.5 KVA DG set complete all as directed.
88Dismantling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and outlet connections, overhauling/ servicing the radiator , clearing, removing blockages, arresting leakages, assembling back including necessary welding, brazing as required , refixing , reconnecting and testing for proper functioning:
8925 KVA Capacity
9062.5 KVA Capacity
9182.5 KVA Capacity
92100/125 KVA Capacity
93Taking down the defective water pump from DG Set & replace with new one for DG set of following capacities complete all as directed by Engr-in-Charge.
9462.5 KVA Capacity, Make : Kirloskar, Model 4R810TA G1
9582.5 KVA Capacity, Make : Ashok Leyland, Model: AL4CTIDG3,
96100 KVA Capacity, Make : Kirloskar, Model 6R1080TA,
97100 KVA Capacity, Make : Greaves, Model 4G11TAG25,
98125 KVA Capacity, Make : Greaves, Model 4G11TAG26,
99125 KVA Capacity, Make : Kirloskar, Model 6R1080TA,
100Supply & fix in replacement of set of belts suitable for following capacity of DG sets as per existing at site :- [Note : Each set included dynamo belt, Fan belt and water pump belt]
10125 to 82.5 KVA DG Set
102100 To 125 KVA DG Set
103Supply & fix in replacement of AVR card suitable for 25 to 82.5 KVA DG set of any make as per existing model at site all as specified and directed.
104Supply & fix in replacement of AVR card suitable for 100 to 125 KVA DG set of any make as per existing model all as specified and directed.
105Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function :
10625 KVA Capacity
10762.5 KVA Capacity
10882.5 KVA Capacity
109100/125 KVA Capacity
110Supply & fix in replacement of Solenoid Switch of DG set complete all as specified and directed.
11125 KVA Capacity
11262.5 KVA Capacity
11382.5 KVA Capacity
114100/125 KVA Capacity
115M&L for replacement of unservicable contactor AC operated 4 pole 415 volts suitable for the following capacity of DG set:-
11625 kVA capacity
11762.5 kVA capacity
11882.5 kVA capacity
119100 kVA capacity
120125 kVA capacity
121Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ servicing, replacement of pim spiral, washers, Cup injector, retainer, Cup screw etc assembling calibiration, setting for proper function refixing and testing for:
12225 KVA Capacity
12362.5 KVA Capacity
12482.5 KVA Capacity
125100/125 KVA Capacity
126Dismantling of fuel injection Pump assembly complete from the engine of following capacity of DG Sets, reconditioning/ servicing, replacement of pim spiral, washers, Cup injector,retainer, Cup screw etc assembling calibiration, setting for proper function refixing and testing for:
12725 KVA Capacity
12862.5 KVA Capacity
12982.5 KVA Capacity
130100/125 KVA Capacity
131Supply & fix in replacement of Fuel Connection Pipe with Benjo Bolt and Washer of the following DG set complete all as specified and directed.
13225 KVA Capacity
13362.5 KVA Capacity
13482.5 KVA Capacity
135100/125 KVA Capacity
136Taking down defective Alternator of DG set of capacity 25 KVA DG set installed at various location. Installations & servicing / overhauling including replacing worn out part like solenoid, bearing, carbon brush, rewinding the starter motor winding etc. & refitting the same after repair for smooth functioning in all respect.
137Taking down defective Alternator of DG set of capacity 62.5 KVA to 82.5 KVA DG set installed at various location Installations & servicing / overhauling including replacing worn out part like solenoid, bearing, carbon brush, rewinding the starter motor winding etc. & refitting the same after repair for smooth functioning in all respect.
138Taking down defective Alternator of DG set of capacity 100 KVA to 125 KVA DG set installed at various location Installations & servicing / overhauling including replacing worn out part like solenoid, bearing, carbon brush, rewinding the starter motor winding etc. & refitting the same after repair for smooth functioning in all respect.
139Supply & fix in repair Door Hinges.
140Supply & fix in repair Door Locks.
141S&F in replacement of AMF control panel factory made cubical type floor mounted totally enclosed fabricated out of CRCA sheet 16 SWG over an angle iron frame made out of 50x50x6 mm angle with removable side cover hinged front panel and rear panel for easy accessebility, epoxy powder coated complete with internal wiring with suitable size copper conductor cable and cable glands for external connections complete suitable for 82.5 KVA DG set with bypass arrangement including all necessary operation and control devices (to meet the requirement of above capacity plus 25% over load) Including following components such as :-
142(a) MCCB 200 Amps, 35 KA-02 No.(b) AC volt meter 500 volts digital type with selector switch-01 No(c) Amp meter digital type CT ratio 200/5 operated with selector switch-01 No(d) Frequency meter digital type-01 No(e) HRC type insturment fuse(f) Indicator lamp for DG set ON/Off indicator-01 No(g) Copper bus bar of capacity 400 Amps -04 Nos(h) Circuit diagram plate - 01 No(j) CT operated KWH meter-01 No and KW/PF meter digital type -01 No(k) Reverse power relay suitable contractor -01 set(l) Battery charging system with indicator and cut off relay's low & high protection reverse current protection duly wired with flexible copper conductor cable and cable connection with lugs/thimble complete as recommended by manufacurer and directed by Engineer-in-Charge.(m) Contactor for DG set supply and main supply of suitable capacity -02 Nos.
143S&F in replacement of AMF control panel factory made cubical type floor mounted totally enclosed fabricated out of CRCA sheet 16 SWG over an angle iron frame made out of 50x50x6 mm angle with removable side cover hinged front panel and rear panel for easy accessebility, epoxy powder coated complete with internal wiring with suitable size copper conductor cable and cable glands for external connections complete suitable for 100 KVA DG set with bypass arrangement including all necessary operation and control devices (to meet the requirement of above capacity plus 25% over load) Including following components such as :-
144(a) MCCB 300 Amps, 35 KA-02 No.(b) AC volt meter 500 volts digital type with selector switch-01 No(c) Amp meter digital type CT ratio 200/5 operated with selector switch-01 No(d) Frequency meter digital type-01 No(e) HRC type insturment fuse(f) Indicator lamp for DG set ON/Off indicator-01 No(g) Copper bus bar of capacity 400 Amps -04 Nos(h) Circuit diagram plate - 01 No(j) CT operated KWH meter-01 No and KW/PF meter digital type -01 No(k) Reverse power relay suitable contactor -01 set(l) Battery charging system with indicator and cut off relay's low & high protection reverse current protection duly wired with flexible copper conductor cable and cable connection with lugs/thimble complete as recommended by manufacurer and directed by Engineer-in-Charge.(m) Contactor fro DG set supply and main supply of suitable capacity -02 Nos.
145Repair to AMF Panels of 25 kVA DG set dismantling/taking down of all electrical connection from unserviceable AMF panel to carry out following repairs :-(a) Replacement of unserviceable microprocessor auto main failure relay 400 volt AC 3 phase 4 wire system having following parameter :-(i) Display of RYB phase voltage.(ii) Display of generating voltage.(iii) Display of generator frequency.(iv) Display of main frequency.(v) Display of battery voltage.(vi) Display of single phase current.(vii) Display of generator run hoursMake:- C&S/Hitech or equivalent.(b) Replacement of digital multifunctional meter of size 96x96mm having following parameter:(i) Voltage, ampere and frequency (c) Replacement of digital energy meter 3 phase of size 96X96mm. (d) Replacement of safety control relay for cranking-01 Nos.(e) Replacement of burnt out control wiring for panel with suitable size of lugs.(f ) Replacement of auto/manual switch
146All as per item No- 33 but for 62.5 kVA to 82.5 kVA DG set .
147All as per item No- 33 but for 100 kVA to 125 kVA DG set.
148Supply only AMF relay for DG set of following capacities-
14962.5 KVA Capacity
15082.5 KVA Capacity
151100 kVA Capacity
152125 kVA capacity
153M&L for painting of DG set of with synthetic enamel paint two coats of existing colour for following capacities
15462.5 kVA capacity
15582.5 kVA capacity
156100 kVA capacity
157110 kVA capacity
158125 kVA capacity
159M&L for MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 36 KA for 25 kVA DG set.
160M&L for MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 36 KA for 62.5 kVA to 82.5 kVA DG set.
161M&L for MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 kVA for 100 kVA DG set.
162M&L for MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 kVA for 125 kVA DG set.
163Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 Core. Including gland and lugs for incoming and outgoing cables.
164Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor of size 120 sqmm 3.5 Core.including gland and lugs for incoming and outgoing cables. Please Enable Macros to View BoQ information
165Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor of size 120 sqmm 3.5 Core.including gland and lugs for incoming and outgoing cables. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57674036
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.22 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Dg Sets, Amf Panels, Control Panels And Connected Allied Works At Nofra, Outlaying Area Under Ge (Nw) Nofra.
Basic Detail
Tender No GE (NW) NOFRA 8588
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 30 Sep 2026
Submission Date 12 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 47.22 Lakhs
Tender Fee 500
EMD 94450
Exemption Available
Document List
25ae222f-028e-4224-ba9d-565cc30215c4.html
BOQ_886638.xls
Tendernotice_1.pdf
tenderpages8588.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

25ae222f-028e-4224-ba9d-565cc30215c4.html

xls

BOQ_886638.xls

pdf

Tendernotice_1.pdf

pdf

tenderpages8588.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders