Tender For Awp For Maintenance Of Pao (Ors) Krc, Dad Residential Colony And Guest House Ranikhet At Ranikhet Under Ge Ranikhet
Tender Overview
Project Description
Tender for Awp For Maintenance Of Pao (Ors) Krc, Dad Residential Colony And Guest House Ranikhet At Ranikhet Under Ge Ranikhet
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Oct-2026 | CorrigendumNo1 | BOQ | 15-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar. |
| 2 | M&L for Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified. |
| 3 | M&L for Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM (1:3) complete all as specified. |
| 4 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws incl taking down existing CGI/Asbestos sheet complete all as specified. |
| 5 | S&F for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws incl taking down existing CGI/Asbestos sheet complete all as specified. |
| 6 | Dismantling boarding, any description, fixed in any position with nails. |
| 7 | Dismantling framed timber scantlings 40 sq. cm and over in section, in any position. |
| 8 | M&L for clean sawn Second class hard-wood in scantlings. |
| 9 | Dismantling PVC water tanks exc 500 Ltrs but not exc 1000 ltr capacity and removing to store. |
| 10 | S&F rotantional moulded polythylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position complete with ball valve of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball and screwd for iron pipe 20mm bore complete all as specified and directed. |
| 11 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. of capacity incl 500 and n exc 1000 Ltr complete all as specified and directed. |
| 12 | Taking up or down 15mm dia steel tubing and connection incl cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge. |
| 13 | S&F for GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 15 mm dia bore. |
| 14 | Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge. |
| 15 | S&F steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 20 mm dia including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete 1:2:4 complete all as specified and as directed by Engineer-in-Charge |
| 16 | S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 17 | S&F in repair fancy type 15mm bore Stop valves (Angle valve), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. |
| 18 | S&F in repair 125mm Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union |
| 19 | S&F in repair 15mm bore dia CP Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 20 | S&F in repair CP brass Tubular towel rail 20mm dia. |
| 21 | S&F in repair brackets for above item No 20. |
| 22 | S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws. |
| 23 | S&F in repair PVC connection 15mm dia and 600 mm long with 2 Nos PTMT nuts complete. |
| 24 | S&F in repair vitreous China Squatting pan 'Orrisa' pattren size 580 x 440mm white with integral foot rest complete. |
| 25 | S&F in repair vitreous china wash down water closet pan pedestal pattern white including connection in drain and in flushing pipe complete including 'P' or 'S' trap complete all as specifed and directed. |
| 26 | S&F in repair Plastic water closet seat cover White closed pattern with recessed bottom and cover and mild steel chromium plated hinging device, fixed in repairs complete. (Make : Jaquar, Hindware & Kohler) |
| 27 | S&F in repair PVC valveless, 10 ltr syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets. |
| 28 | S&F in repair vitreous china wash basin, white, flat back, size 550x400 excluding taps, chain and plug and porcelain stopper but including brackets, coupling, bottle trap/waste pipe complete all as specified and directed. |
| 29 | S&F in repair 15mm bore dia of pipe pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 30 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 31 | S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 32 | S&F in repair PVC (SWR) floor trap, plain with grating (waste hole/plain type) including jointing with solvent cement, 75 to 100 mm mm diameter of outlet, all as specified. |
| 33 | S&F in repair looking mirror of selected quality sheet glass 5.5 mm thick designer with chromium plated brass screw and cup washer complete all as specified and directed. |
| 34 | S&F in repair for 15 mm bore dia Brass CP mixer (Wall mixer 3-in-1) for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 35 | S&F in repair 15 mm bore dia Brass CP mixer (Wash basin mixer) for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 36 | S&F in repair 15 mm bore dia Brass CP mixer (Sink mixer wall mounted) for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 37 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long |
| 38 | S&F in repair Corner Glass Shelf (with Bracket) |
| 39 | Demolition and breaking up drain pipes (SGSW, AC, PVC or reinforced cement) set in cement mortor internal dia of pipe 75 to 100 mm complete all as specified and directed. |
| 40 | S&F for 110 mm bore SWR pipes single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all specified and directed. |
| 41 | S&F for 110 mm bore SWR pipes single socketed in any length with rubber ring joints fixed to walls complete all specified and directed. |
| 42 | S&F for 75 mm bore SWR pipes single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all specified and directed. |
| 43 | S&F for 110 mm bore PVC (SWR) bends complete all as specified and directed. |
| 44 | S&F for 75 mm bore PVC (SWR) bends complete all as specified and directed. |
| 45 | S&F for 110 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 46 | S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 47 | S&F for stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipecomplete all as specified and directed. |
| 48 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc. |
| 49 | M&L for 10 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth (without using extra cement) complete all as specified and directed. |
| 50 | M&L for 5 mm thick cement plaster in cement mortar 1:3 on brick or concrete surface etc. of ceiling finished even and smooth (without using extra cement) complete all as specified and directed. |
| 51 | M&L for 15 mm thick cement plaster in cement mortar 1:4 on brick or concrete surface etc. on wall finished even and smooth (without using extra cement) including liquid water proofing compound complete all as specified and directed. (Note : Liquid water proofing compound shall be paid separately) |
| 52 | Supply only Liquid water proofing compound |
| 53 | M&L for preparation of newly plastered surfaces of wall and applying two coats of distemper oil emulsion over 1mm thick putty and one coat of primer all as specified. |
| 54 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed. |
| 55 | M&L for preparation of newly plastered surfaces of wall and applying two coats cement base paint over primer complete all as specified and directed. |
| 56 | M&L for preparation of old steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 57 | M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 58 | Complete removal of existing treatment of wall surface and applying two coats of oil bound distemper over primer and 1mm thick putty complete all as specified and directed. |
| 59 | M&L for preparation of old surface of wall and applying one coat of oil bound distemper complete all as specified and directed. |
| 60 | M&L for Washing, rubbing down and stopping of distempered of old surface of wall and applying two coats of oil bound distemper complete all as specified and directed. |
| 61 | M&L for preparation of old surface of ceiling and applying one coat of white washing complete all as specified and directed. |
| 62 | M&L for preparation of old surface of wall and applying one coat of cement base paint complete all as specified and directed. |
| 63 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified. |
| 64 | M&L for 75mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in plinth/sub base. Complete all as specified. |
| 65 | S&F in repair fancy type Curtain rods decorative type stainless steel 25mm nominal dia of approved quality (1mm wall thickness) including fixing of two number decorative brackets fixed in brick/concrete wall, Two number of latto on both ends of curtain rods complete all as directed and specified. |
| 66 | Taking down wall panelling and similar work complete all as specified and directed. |
| 67 | S&F for Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 68 | Hacking out old broken glasses any thickness size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed. |
| 69 | M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed upto 8th floor Height. |
| 70 | S&F 3mm thick Figured glass, pin head type and glazing with oil putty in square n. exc 0.80 Sqm in each panes fixed any bldg hight complete all as specified and directed upto 8th floor Height. |
| 71 | S&F in rapair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 72 | Taking down of shutters of any description in same opening exc 2 sqm each complete all as specified and directed. |
| 73 | Refixing of shutters of any description in same opening exc 1 sqm and n exc 2 sqm each complete all as specified and directed. |
| 74 | Refixing of shutters of any description in same opening exc 2 sqm each complete all as specified and directed. |
| 75 | Factory made, Plain framed panelled shutters of 2nd class hard wood 35mm thick (any number of panels) with lock rails and panels of 9mm thick BWP commercial ply or 12mm veneered parcticle board with commercial veneering on both faces. The size of rails and stile as per IS:1003, complete all as specified and as directed. |
| 76 | Glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 77 | S&F for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 78 | Preparation of new wood or wood based surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint, over a coat of primer complete all as specified and as directed. |
| 79 | S&F for MS butt hinges 100mm long medium weight cold rolled mild steel etc |
| 80 | S&F for aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified . |
| 81 | S&F for Extruded aluminum alloy handle, fabricated type, anodized 150mm size. |
| 82 | S&F for Aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete. |
| 83 | S&F for Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel fixed in floor with over all length of cover plate 140 mm fixed complete. |
| 84 | S&F for mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete. |
| 85 | Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof). |
| 86 | Cutting out cracks to V-section in existing roofs or terracing surfaces, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight), complete all as specified and as directed. |
| 87 | M&L for PCC 1:2:4 type B1 with 20 mm graded stone aggregate as in padding over roof slab for making slope on roof top complete all as specified and directed. |
| 88 | M&L for 10 mm thick Cement plaster on surfaces of concrete in CM 1:4 on roof surfaces (Over PCC Padding) with WPC (WPC shall be measured and paid separately) |
| 89 | Supply only of liquid water proofing compound complete all as specified and directed. |
| 90 | M&L for applying evenly a tack coat of industrial bitumen 85/[email protected]/Sqm complete all as specified and directed. |
| 91 | M&L for APP based modified pre-fabricated , minimum 3 mm thick and weighing not less than 3.00 Kg per Sqm water proofing membrane reinforced with polyester non woven fabric (wt not less than 150gms/sqm) land on primed surface by forced application conforming to IS -3488 @ 0.4 LT/Sqm, membrane laid by torch application side over lap of 75 mm and end overlap of 100 mm wide, joint/overlap sealed with torch applications for parapet etc the membrane taken up to 30 cm and then inserted inside the parapet after making necessary groove in brick or RCC parapet wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 as required after necessary preparation of the surface and applying two coat of aluminum painting complete as per manufacturer’s instructions. |
| 92 | Dismantling wrought iron or mild steel work of any description not otherwise provided |
| 93 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410-W (GdeE- 250) qualityAcomplete all as directed and specified. |
| 94 | Excavation in trenches not exc 1.5m wide and not exceeding 1.5 mtr in depth for foundation etc shaft, cesspits, manholes sewage line etc not exc. 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed. |
| 95 | Returning, filling in, trenches with soil in layers not exc 25 cm thick, watering and well ramming complete all as specified and directed. |
| 96 | Removal of surplus soil to a distance not exc 50 mtr away & deposting where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 97 | Demolition and breaking up old unserviceable salt glazed stoneware pipe 150mm bore at any depth set in cement morter incl PCC bed complete all as specified and directed. |
| 98 | M&L for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregates) bedding for sewage lines of 150mm bore incl packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 99 | Supply and fixed class SN-8, dia of pipe 150mm & thickness of pipe as specified in IS 16098 (Part-2):2013, clause 6.3.1 table no 5 structured wall polythelene piping system (pipe with online/offline coupler and elastomeric sealing ring) with non smooth external anular corrugated and smooth internal surface (double wall) for non pressure underground sewerage & drainage application polythylene piping fitted with help of coupler attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying at prescribed gradient, depth and alignment, testing the water tightness of the joint, ensuring the continuity tests of the specified pipe segments etc including all necessary fittings (cost of fittings, rubber rings, gaskets etc includded) complete all as specified and directed by Engineer-in-charge. |
| 100 | S&F Precast Plastic fibre reinforced concrete manhole cover medium duty of size 900mm x 450mm x 80mm confoming to IS- 12592 incl demolition of old RCC cover , complete all as specified and directed. |
| 101 | Demolition of brick work/stone boulder measonary built in cement mortar or cement lime mortar of any description and in any position all as specified. |
| 102 | M&L for brick work in CM (1:4) straight or curved on plan exc 6.0m mean radius and using old size sub class 'B' bricks all as specified. |
| 103 | Providing cement concrete type B1 1:2:4 (20mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 104 | Providing cement concrete type C2 1:3:6 (40mm graded aggregate) as in surface channels and drains complete all as specified and directed. |
| 105 | M&L for Finishing cement concrete surface even and smooth using extra cement complete all as specified. |
| 106 | M&L for 55mm thick cement concrete type B-1, 1:2:4 (20mm gradedaggregate) complete all as specified and directed. |
| 107 | Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 108 | M & L point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia )with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed. One light/One fan/one bell point controlled by one modular switch |
| 109 | One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 110 | One modular socket outlet 3 pin 6 amps controlled by one switch on independent board. |
| 111 | All as per item No 2 herein before but wiring with 2.5 sqmm copper wire (FRLSH) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board. |
| 112 | S & F point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core multi-stranded) copper conductor cable (FRLSH) drawn into and including PVC casing capping of suitable size with its all necessary fittings and accessories on wooden / stone / brick masonry wall surface and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size solid copper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed. One light/one fan/one bell point controlled by one, one way switch. |
| 113 | One socket outlet 5 pin 5 amps controlled by one switch on same board. |
| 114 | One socket outlet 5 pin 5 amps controlled by one switch on independent board. |
| 115 | All as per item No 4 herein before but wiring with 2.5 sqmm copper wire (FRLSH) PVC and 2.5 sqmm earth wire for socket outlet 6 pin 16 amps on independent board. |
| 116 | Supply and fix in repair modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 117 | Supply and fix in repair socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 118 | Supply and fix in repair switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 119 | Supply and fix in repair socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 120 | S&F in repair ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 121 | S & F in repair lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 122 | S & F in repair MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type in the MCB DB including taking down complete all as specified and directed. |
| 123 | S & F in repair MCB SPN, 240 volts, 40 Ampere, rupturing capacity 10 KA, ‘B’ curve type in the MCB DB including taking down complete all as specified and directed. |
| 124 | S & F in repair MCB Double pole, 240 volts, 40 Amp, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. |
| 125 | S & F in repair MCB Four pole, 415 volts, 40 to 100 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. |
| 126 | S&F in repair sheet metal enclosure for DBs(double door type) single pole and neutral 8 way including blacking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 127 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings |
| 128 | Supply and fix in repair High quality LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transfer incl one LED PC tube rod and driver, internaly pre wired of 1.5 sqmm twin twisted flexible cable all as specified & directed.NOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 129 | S & F in repair Recess mounting LED luminaire 600mm x 600 mm ,36 W, 220V, with high efficiency PMMA diffuser soft glare free light suitable for recessed mounting ,with powder coated CRCA housing with LEDs, seamless front frame complete with driver and all accessories internally pre-wired and including necessary cutting as required in panel and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 130 | S & F in repair LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser complete with all accessories and including LED light driver holder connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed.Make : Bajaj//Philips/HavellsNOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 131 | Taking out old U/S Sub main wiring for replacement including S&F sub main wiring with two single core FRLSH PVC insulated and sheathed 1100 Volts grade, 6.0 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 6.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length). |
| 132 | Supply and fixing in repair LED building security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum housing with high eficiency LEDs as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and heat resistant, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete. all as specified and directed .NOTE : The contractor must submit 5 years warranty for LED fittings. |
| 133 | Taking down for Repair of Exhaust fan of size 250 mm to 450 mm sweep of any type including replacement of burned copper winding, bearing and any other accessories and refixing after repair with suitable size nut bolts and wire complete all as specified and directed. |
| 134 | S & F in repair call bell ding dong AC, 230V single pole fixed over with and including sunk spressed steel box of size 175mmx100mm with 3mm thick plastic laminated backalite shut cover fixed with brass screw complete all as specified and directed, |
| 135 | S&F in repair modular bell push, 6 Amp 1 module complete all as specified and directed. |
| 136 | S & F in repair LED Bulb 9W complete all as specified & directed. |
| 137 | S & F LED Bulb, LEDZ Inverter lamp 9W CDL B22 with minimum back-up of up to 4Hours, autocut-off after full charging of battery and long-life of up to 15000 Hours complete all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender