Tender For Tender For Supply Of Equipment/Material, Design, Erection, Testing And Commissioning Of Augmentation Of Existing 11/0.4 Kv 25 Kva Sub-Station Parihar-Iii (Naghuien) To 63 Kva Along With Three Phase Lt Line From The Augmented Dtr For Provid
Tender Overview
Project Description
Tender for Tender For Supply Of Equipment/Material, Design, Erection, Testing And Commissioning Of Augmentation Of Existing 11/0.4 Kv 25 Kva Sub-Station Parihar-Iii (Naghuien) To 63 Kva Along With Three Phase Lt Line From The Augmented Dtr For Providing Sop To Assistant Engineer, Piu Chamba, Jal Shakti Vibhag For Lift Water Supply Scheme At Madhiyar, Ditrict Chamba In (E) Section Chaned (U) Esd Hpsebl Chamba No-Ii.T.S No.06/2026-27, Deposit
BOQ
| Sl. No. | Item Description |
| 1 | Supply Part- Aug. Of 25 kVA DTR to 63 kVA |
| 2 | 11/0.4 kV, 63 kVA Distribution Transformer ( Outdoor Type) |
| 3 | ACSR Conductor 6/1/3.35, 50 sq. Mm for earthing & jumpering |
| 4 | X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] |
| 5 | MS Angle Iron (50X50x5 mm), Length: 2800 mm x(1 Nos for LA's) |
| 6 | X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 7 | X-Arm [Channel Iron (100x50x6 mm), Length : 2800 mm x 2 Nos for Transformer bed |
| 8 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer |
| 9 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 10 | MS Angle Iron 35x35x5 mm), Length : 460 mm x 2 Nos |
| 11 | MS Angle Iron 50x50x6 mm), Length : 950 mm x 2 Nos for Bed Knee Bracing |
| 12 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos for LT DISTRIBUTION BOX and GO switch assembly |
| 13 | MS Angle Iron (50X50x6 mm), Length : 450 mm x 1 Nos for LT DISTRIBUTION BOX and GO switch assembly |
| 14 | GO Switch Handle supporting : [ Channel Iron (75x40x6 mm), Length:460 mm |
| 15 | GO AB Switch Unit (11kV, 400A, 25 KA ) Triple Pole O/D Type |
| 16 | D.O Fuse Unit |
| 17 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 18 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 19 | 11 kV Pin Insulator |
| 20 | Stay set complete |
| 21 | Stay Wire (7/3.15 mm) 6Kg per set |
| 22 | Pipe Earthing Set with GI, Charcoal & salt |
| 23 | LT Distribution Panel Box with MCCB 100 amp 3P 35kA , ICS =100 % ICU, KIT KAT 200 Amp |
| 24 | Half Clamp (M.S. Flat 50X6 mm) |
| 25 | Full Clamp ( M.S Flat 50x6 mm) |
| 26 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 27 | Aluminium Thimble |
| 28 | Copper Thimble |
| 29 | Danger Plate |
| 30 | Barbed Wire |
| 31 | LT Cable 3.5 Core 120 sq. mm |
| 32 | Aluminium Paint. |
| 33 | Red Oxide |
| 34 | LT Switched Capacitors for 63 KVA DTR (27 kVAr) |
| 35 | Energy Meter (3-Ph, 4-Wire) Smart Meter for 11/0.4 kV 63 kVA DTR( Specification/Make be got approved from Sub-Divisional Engineer) |
| 36 | Kitkat Fuse 400A, 415 V |
| 37 | Chain Link Fencing , Angle Iron, gate for transformer fencing |
| 38 | Insulation Tester (Megger) 2500 V ( Specification/Make be got approved from Sub-Divisional Engineer) |
| 39 | Erection part - Aug. Of 25 kVA DTR to 63 kVA |
| 40 | 11/0.4 kV, 63 kVA Distribution Transformer ( Outdoor Type) |
| 41 | ACSR Conductor 6/1/3.35, 50 sq. Mm for earthing & jumpering |
| 42 | X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] |
| 43 | MS Angle Iron (50X50x5 mm), Length: 2800 mm x(1 Nos for LA's) |
| 44 | X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 45 | X-Arm [Channel Iron (100x50x6 mm), Length : 2800 mm x 2 Nos for Transformer bed |
| 46 | X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer |
| 47 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 48 | MS Angle Iron 35x35x5 mm), Length : 460 mm x 2 Nos |
| 49 | MS Angle Iron 50x50x6 mm), Length : 950 mm x 2 Nos for Bed Knee Bracing |
| 50 | MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos for LT DISTRIBUTION BOX and GO switch assembly |
| 51 | MS Angle Iron (50X50x6 mm), Length : 450 mm x 1 Nos for LT DISTRIBUTION BOX and GO switch assembly |
| 52 | GO Switch Handle supporting : [ Channel Iron (75x40x6 mm), Length:460 mm |
| 53 | GO AB Switch Unit (11kV, 400A, 25 KA ) Triple Pole O/D Type |
| 54 | D.O Fuse Unit |
| 55 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 56 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 57 | 11 kV Pin Insulator |
| 58 | Stay set complete |
| 59 | Stay Wire (7/3.15 mm) 6Kg per set |
| 60 | Pipe Earthing Set with GI, Charcoal & salt |
| 61 | LT Distribution Panel Box with MCCB 100 amp 3P 35kA , ICS =100 % ICU, KIT KAT 200 Amp |
| 62 | Half Clamp (M.S. Flat 50X6 mm) |
| 63 | Full Clamp ( M.S Flat 50x6 mm) |
| 64 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 65 | Aluminium Thimble |
| 66 | Copper Thimble |
| 67 | Danger Plate |
| 68 | Barbed Wire |
| 69 | LT Cable 3.5 Core 120 sq. mm |
| 70 | Aluminium Paint. |
| 71 | Red Oxide |
| 72 | LT Switched Capacitors for 63 KVA DTR (27 kVAr) |
| 73 | Energy Meter (3-Ph, 4-Wire) Smart Meter for 11/0.4 kV 63 kVA DTR( Specification/Make be got approved from Sub-Divisional Engineer) |
| 74 | Kitkat Fuse 400A, 415 V |
| 75 | Transportation Charges ( Mechanical+ Mannual Carriage for an average lead of 1 km) |
| 76 | Supply Part- 0.790 km 3-Ph LT Line on ST 9 mtr long poles |
| 77 | Steel Tubular Poles 9 mtr. Long W/L 200 Kgs |
| 78 | LT XLPE Cable 3.5 Core 35 sq. mm PVC (1.1 kV, AI, Un-armoured) |
| 79 | ACSR 6/1/3.35 50 sq. Mm conductor |
| 80 | Shackle Insulator (16 KN) |
| 81 | D-Iron (U-clamp) |
| 82 | Eye Hook |
| 83 | LT Earthing Set complete( Preferably coil earthing) |
| 84 | Earth Wire (GI, 8SWG) |
| 85 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 86 | Aluminium Paint. |
| 87 | LT Stay Set complete REC No 31/1983 i/c Stay Clamp |
| 88 | Egg Insulator (LT) |
| 89 | Stay Wire (7/8 SWG) |
| 90 | Half Clamp (M.S. Flat 50X6 mm) |
| 91 | Full Clamp ( M.S Flat 50x6 mm) |
| 92 | Angle Iron 75x75x6, Length 1.5 Mtr |
| 93 | Come Along Clamp |
| 94 | Digital Clamp Multimeter (AC/DC) |
| 95 | Erection Part-0.790 km 3-Ph LT Line on ST 9 mtr long poles |
| 96 | Steel Tubular Poles 9 mtr. Long W/L 200 Kgs |
| 97 | Muffs with concerete filling ( To be provided by HPSEBL) |
| 98 | LT XLPE Cable 3.5 Core 35 sq. mm PVC (1.1 kV, AI, Un-armoured) |
| 99 | ACSR 6/1/3.35 50 sq. Mm conductor |
| 100 | Shackle Insulator (16 KN) |
| 101 | D-Iron (U-clamp) |
| 102 | Eye Hook |
| 103 | LT Earthing Set complete( Preferably coil earthing) |
| 104 | Earth Wire (GI, 8SWG) |
| 105 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 106 | Aluminium Paint. |
| 107 | LT Stay Set complete REC No 31/1983 i/c Stay Clamp |
| 108 | Egg Insulator (LT) |
| 109 | Stay Wire (7/8 SWG) |
| 110 | Half Clamp (M.S. Flat 50X6 mm) |
| 111 | Full Clamp ( M.S Flat 50x6 mm) |
| 112 | Angle Iron 75x75x6, Length 1.5 Mtr |
| 113 | Transportation of material ( Mechanical Transportation+Mannual carriage for an average lead of 1 km) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender