Rural Development Government Departments Closing in 2 days TDR #57670908

Tender For Mp-Lads-Scheme-2019-20-Scheme Proposed By Sri. K. Somaprasad Ex Mp(Rs) - Construction Of Open Air Auditorium At Sooranad Rakthasakshi Smaraka Stadium Ward 18 Parakkadavu,-Sooranad North Grama Panchayathu-General Electrical Work

Issued by Government Departments · Kollam, Kerala
Tender Value
1.80 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
2 days left
EMD
4518
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Mp-Lads-Scheme-2019-20-Scheme Proposed By Sri. K. Somaprasad Ex Mp(Rs) - Construction Of Open Air Auditorium At Sooranad Rakthasakshi Smaraka Stadium Ward 18 Parakkadavu,-Sooranad North Grama Panchayathu-General Electrical Work

BOQ

Name of Work:- MP-LADS-Scheme-2019-20-Scheme proposed by Sri. K. Somaprasad Ex MP(RS) - Construction Of Open Air Auditorium at Sooranad Rakthasakshi Smaraka stadium Ward 18 Parakkadavu,-Sooranad North Grama Panchayathu-General Electrical Work
Sl. No. Item Description
1Electrification
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
390.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
490.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
590.3.10:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
6OD144926/2026-2027:Supply and fixing LED Bulk head with IP65 protection, suitable for surface and wall mounting application including giving connection etc as required ( Philips make WT140W LED7S CW PSU S1 PC or equivalent Make) -
790.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
8OD144927/2026-2027:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output minimum 120lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
990.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
101.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
111.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
1290.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
13OD144932/2026-2027:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C-
141.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
151.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
161.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
171.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
181.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
191.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
201.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
211.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
221.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
231.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
241.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
251.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
262.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
272.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
282.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
292.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
305.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
31OD219773/2025-2026:Supply and providing test joint for the earthing system using 2 NOs of the following sizes of strips including cutting and bending to shape ,drilling necessary holes and fixed to the watering pipe etc as required 2x25x3 mm tinned copper strip
3290.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
3390.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3490.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
3590.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
3690.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
37OD219792/2025-2026:Supply and providing 25x3 mm brass bolt and nut with washer including drilling holes as required
38OD219791/2025-2026:Supply and providing 25x6 mm brass bolt and nut with washer including drilling holes as required
39OD219781/2025-2026:Supply and fixing Meter board SMC for fixing single phase KWH meter,32A DP MCB,32A cutout,N/L etc (Sintex GSMB 4422 or equivalent)
40OD219824/2025-2026:Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main
41OD219780/2025-2026:Amount to be deposited with KSEB for availing service connection/additional load (actual amount will be reimbursed on production of original documents) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57670908
AUTHORITY Government Departments
TENDER VALUE 1.80 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Mp-Lads-Scheme-2019-20-Scheme Proposed By Sri. K. Somaprasad Ex Mp(Rs) - Construction Of Open Air Auditorium At Sooranad Rakthasakshi Smaraka Stadium Ward 18 Parakkadavu,-Sooranad North Grama Panchayathu-General Electrical Work
Basic Detail
Tender No S3.1/2023
Bidding Type Tender
Location
City Kollam
State Kerala
Key Dates
Publish Date 23 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 1.80 Lakhs
Tender Fee 555
EMD 4518
Exemption Available
Document List
737de1f5-1d63-4284-be44-4ce1bc3a7e71.html
affdvt.pdf
BOQ_1478686.xls
fot.pdf
preeagree.pdf
sbdddd.pdf
Tendernotice_1 (20).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

737de1f5-1d63-4284-be44-4ce1bc3a7e71.html

pdf

affdvt.pdf

xls

BOQ_1478686.xls

pdf

fot.pdf

pdf

preeagree.pdf

pdf

sbdddd.pdf

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders