Tender For Repair/Maintenance And Replacement Of Unserviceable Lt Ug Cables And Lt Panels Installed At Scientist Hostel, Officers Mess And Pump House At Drdo Township Kanchanbagh Under Ge (I) R&D Kanchanbagh.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
20 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance And Replacement Of Unserviceable Lt Ug Cables And Lt Panels Installed At Scientist Hostel, Officers Mess And Pump House At Drdo Township Kanchanbagh Under Ge (I) R&D Kanchanbagh.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of LTUG cable, 1100 volts grade, PVC insulated, PVC unsheathed armoured with aluminum conductor cable complete including lugs of 300 SQMM 3.5 CORE sizes for the following nominal cross sectional areas of cables including taking down old unserviceable cable complete all as directed |
| 2 | Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of LTUG cable, 1100 volts grade, PVC insulated, PVC unsheathed armoured with aluminum conductor cable complete including lugs of 185 SQMM 3.5 CORE sizes for the following nominal cross sectional areas of cables including taking down old unserviceable cable complete all as directed |
| 3 | Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of LTUG cable, 1100 volts grade, PVC insulated, PVC unsheathed armoured with aluminum conductor cable complete including lugs of 120 SQMM 3.5 CORE sizes for the following nominal cross sectional areas of cables including taking down old unserviceable cable complete all as directed |
| 4 | Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of LTUG cable, 1100 volts grade, PVC insulated, PVC unsheathed armoured with aluminum conductor cable complete including lugs of 95 SQMM 3.5 CORE sizes for the following nominal cross sectional areas of cables including taking down old unserviceable cable complete all as directed |
| 5 | S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.Make Danson |
| 6 | Excavation in trenches not exceeding 1.5m wide and depth beyond 1.5m but not exceeding 3 metre deep and getting out in loose/ soft soil, complete all as specified and directed by Engineer-in-charge. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge. |
| 8 | Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge. |
| 9 | Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge.Note :- For payment purpose punned thickness shall be measured. |
| 10 | Supplying and laying unreinforced precast concrete cable cover, class HV, type 2, flat, size 450mmx l80mm x 40mm, complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for laying of common burnt bricks, sub class 'B', old size 230 x 115 x 75 mm in trenches for cable protection complete all as directed. |
| 12 | Supply, laying and testing in repair of HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 volts grade cross section area 185 sqmm 3 core complete laid in trenchers, duct, passing through pipe, fixed to poles complete all as specified and directed by Engr-in-Charge. |
| 13 | Supply and fixing in replacement of GI strip 32x6mm, buried in ground upto 50 cm or fixed to wall with insulators etc for loop earthing including welding for joints complete all as specified and directed by Engr-in-Charge.Note : Earth work will be measured and paid separetely. |
| 14 | Supply, fix in repairs, testing and commissioning of Air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT polymeric insulators and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically operated including locking arrangement for operating handle with and including 7 levers Navtal lock complete suitable for current rating of 400 Amps HT 11 KV working pressure all as specified and directed. |
| 15 | Earthing complete with GI earth plate electrode 600x600x3.15mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.25mtr below normal ground level connected to the GI strip 32x6mm size by means of bolts ,nuts,check nuts and washers of copper and 32x6mm Copper strip protected by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item.(ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for separately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistance is not obtained, the contractor shall redo the earthing without any extra cost to the department. |
| 16 | S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for fixing cable route indicators made of PCC (1:3:6) including CI part indicator brown colored of circular shape of dia 150mm fixed on angle iron of size 40 x 40 x 4mm not less than 0.3mtr of height over the PCC duly engraved \\"HT cable / HT cable joint\\" PCC block size 150 x 150 x 900mm fixed on 300mm below ground level complete all as specified and directed. |
| 18 | Disconnecting Existing panel and its connections and supply, install, testing and commissioning of new powder coated out door LT feeder panel of 600 Amps, factory fabricated, CPRI approved, cubicle type, made out of 3.15 mm thick CRCA sheet, vermin proof with Aluminium bus bar of 600 Amp, Al strip 3 phase and neutral connections, locking arrangements and painting with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio,ICs=100%ICu and pilot indication lamps along with provision of necessary cable entry/ exit boxes for all incoming and out going cables with suitable cable glands including PCC foundation complete all as specified and directed and consisting the following :- (a) MCCB 4 Pole, 415 volts adjustable type, 500 Amps wth breaking capacity 36KA -01 No. (incomming)(b) MCCB 3 Pole, 415 volts adjustable type, 400 Amps with breaking capacity 35KA -01 Nos. (Outgoing)(c) MCCB 3 Pole, 415 volts adjustable type, 250 Amps with breaking capacity 25KA -01 Nos. (Outgoing)(d) MCCB 3Pole, 415 volts adjustable type, 125 Amps with breaking capacity 25KA -02Nos. (Outgoing)(e) 3-phase Panel mounted Digital type Voltmeter meter 0-500 Volts with selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(f) Phase Indicating lamp LED type for Red, Yellow and Blue - 01 SetNote : (a) All existing incoming and out going cables are to be connected with proper lugs, glands, nuts & bolts etc (b) The cost including digging of trenches for connecting to the new panel boards and making good the disturbed surfaces(c) The panel shall be fabricated from a reputed firm(CPRI Approved) with approval of Engineer in charge . |
| 19 | Disconnecting Existing panel and its connections and supply, install, testing and commissioning of new powder coated out door LT feeder panel of 500 Amps, factory fabricated, CPRI approved, cubicle type, made out of 3.15 mm thick CRCA sheet, vermin proof with Aluminium bus bar colour coded and painting with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio including PCC foundation complete all as specified and directed and consisting the following :- (a) MCCB 4 Pole, 415 volts adjustable type, 400 Amps wth breaking capacity 36KA -01 No. (incomming)(b) MCCB 3 Pole, 415 volts adjustable type, 200 Amps with breaking capacity 35KA -03 Nos. (Outgoing)(c) MCCB 3 Pole, 415 volts adjustable type, 250 Amps with breaking capacity 25KA -01 Nos. (Outgoing)(d) MCCB 3Pole, 415 volts adjustable type, 125 Amps with breaking capacity 25KA -02Nos. (Outgoing)(e) 3-phase Panel mounted Digital type Voltmeter meter 0-500 Volts with selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(f) Phase Indicating lamp LED type for Red, Yellow and Blue - 01 SetNote : (a) All existing incoming and out going cables are to be connected with proper lugs, glands, nuts & bolts etc (b) The cost including digging of trenches for connecting to the new panel boards and making good the disturbed surfaces(c) The panel shall be fabricated from a reputed firm(CPRI Approved) with approval of Engineer in charge . |
| 20 | Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed. |
| 21 | M&L fo GI tubing light grade 80 mm dia with all fittings laid in trench or fixed on wall, along pole for protection of cable complete all as specified and directed by Engr-in-Charge. |
| 22 | Plain cement concrete, (1:4:8), type D-2( using 40mm graded crushed stone aggregates) as in foundation filling & mass concrete for pole complete all as specified and directed by Engr-in-Charge. |
| 23 | Plain cement concrete, (1:3:6), type C-1( using 20mm graded crushed stone aggregates) as in foundation filling & mass concrete for stay complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender