Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57665249

Tender For Repair / Maintenance Of Scada System Of Water Supply Installation And Its Connected Items At Af-I And Repair / Maintenance Of Ceiling Fan, Wiring, Panel Sockets At Khambhaliya And Dwarka Under Ge (Af) Jamnagar No.2

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
35 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
13 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Scada System Of Water Supply Installation And Its Connected Items At Af-I And Repair / Maintenance Of Ceiling Fan, Wiring, Panel Sockets At Khambhaliya And Dwarka Under Ge (Af) Jamnagar No.2

BOQ

Name of Work:- REPAIR / MAINT OF SCADA SYSTEM OF WATER SUPPLY INSTALLATION AND ITS CONNECTED ITEMS AT AF-I AND REPAIR / MAINT OF CEILING FAN, WIRING, PANEL SOCKETS AT KHAMBHALIYA AND DWARKA UNDER GE (AF) JAMNAGAR NO.2
Sl. No. Item Description
1Supply installation testing and commissioning of PLC based Graphic Mimic Panel with appropriate number of inputs and outputs and 7\\" Colour touch screen HMI with minimum 2 nos. serial ports and 1 no. USB port. The Panel shall be of suitable size, made out of Aluminium / CRCA sheet of suitable that shall clearly depict the entire layout of the water supply system including taking down of existing mimic panel with all accessories. The same shall include pump status, valve status, level of tanks, etc.
2S&F 150 mm dia butterfly valve cast iron body confirming to IS 13095, class PN 1.6, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc including S&F motorised actuator suitable for 150 mm dia incl shaft suitable size if reqd and taking down old one butterfly valve and actuator complete all as specified and directed.
3Supply, Installation Testing & Commissioning of pressure transmitter with following specification including necessary power pack for supply of DC. Power supply: 10-36 V DC Process connection: G ½\\" Enclosure: whether proof IP 65 Process temperature: -30 to 120 Celsius Accuracy: 0.25 % including taking down of existing pressure transmitter with all accessories etc complete all as specified and directed.
4Supply, Installation Testing and Commissioning of Ultrasonic Level Transmitter complete all as directed by Engineer-in-Charge. Range: 0-5 meters Accuracy: 0.5 % minimum Supply Voltage : 24V dc Output : 4-20 mA Ultrasonic Frequency: 75 kHz burst, rep. rate 96 ms Delay at Power-up: 1.5 seconds including taking down of existing ultrasonic level transmitter with all accessories etc complete all as specified and directed.
5Supply, installation, testing and commissioning of PLC based centralized SCADA system with the following hardware & software for process control, visualization and data acquisition as per specifications etc complete all as specified and directed.
6Supplying and fixing in repair on wall / drawing through existing pipe (if any) 2 x 1.5 sq.mm. PVC insulated and PVC sheathed armoured copper cable with suitable size of saddles etc complete etc as required. (for solenoid valve) all as directed. Note: 2 runs of 1.5sqmm cable shall be measured as one unit
7Supplying and fixing in repair on wall / drawing through existing pipe (if any) 4 x 1.5 sq.mm. PVC insulated and PVC sheathed armoured copper cable with suitable size of saddles etc complete etc as required. (for MOV) all as directed. Note: 4 runs of 1.5sqmm cable shall be measured as one unit
8Supplying and fixing in repair on wall / drawing through existing pipe (if any) 6 x 1.5 sq.mm. PVC insulated and PVC sheathed armoured copper cable with suitable size of saddles etc complete etc as required. (for Actuator) all as directed. Note: 6 runs of 1.5sqmm cable shall be measured as one
9Supply & fix in repair and drawing through existing pipe/fixing on wall/surface/pipe 0.5sqmm, 5 pair, PVC insulated and PVC sheathed armoured communication cable with suitable size of saddles etc complete. (for Starter) all as directed. Note: 5 pairs of cable shall be measured as one unit
10Supply & fix in repair TV screen 32 inch Full HD LED or 4K resolution 230 volt 50 Hz for operating of SCADA system complete all as specified and directed .
11Supply & fix in repair inverter completre 1550/12volt 140-0 Va pure sine Wave single phase 230 volt 50 Hz with Luminous Tubular Battery Rc 25000 with 4 year warranty with free replace including fiber trolly for battry and inveret fixing including power point arrangement for inverter fixing complete all asspecified and directed by Engr-in-Charge. Make- Sine Volt and Luminoius or equivalant
12Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc.
13M&L for point wiring surface type with single core 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable (FRLS)including 1.5 Sqmm PVC insulated unsheathed copper conductor as earth continuity conductor drawn in and including ISI marked PVC casing caping not less than 20mm width with its accessories, and fixed in existing sunk boxes and covered with new 3.00 mm thick ISI marked laminated sheet cover and brass screw with cup washers for fixing switches/sockets/regulators etc.
14(a) One light point controlled by one switch
15(b) One fan point controlled by one switch.
16(c ) One 3 pin 5 Amps socket outlet point on independent board
17(d) One 3 pin 5 Amps socket point on the same board with other switches
18(e) One light point controlled by two two way switches
19Ditto all as per srl item No 13 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket.
20M&L for point wiring with concealed type in PVC Conduit with PVC insulated, unsheathed, single core multistandard copper conductor cable (FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through PVC conduit and fixed in sunk boxes and covered with 3.0mm thick ISI marked laminated sheet cover and brass screw with cup washers for switches / sockets / regulators etc.
21(a) One light point controlled by one piano type switch single pole one way.
22(b) One fan point controlled by one switch.
23(c) One 3/2 Pin 5 Amp socket out let point on the independent board.
24(d) One socket outlet 3/2 pin, 5 Amp, point on the same board with other switches.
25(e) One light point controlled by 2 way switch 5 amp single pole.
26Ditto all as per srl item No 15 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket.
27S & F switch piano, flush type single pole, one way 5 Amps
28S & F switch piano, flush type single pole, two way 15 Amps
29S & F switch socket outlet 2in1, 3pin,5A
30S & F switch socket outlet 2 in 1, 3 pin, 5 Amps and 15 Amps flush type.
31S & F ceiling rose surface bakelite 65x50 mm two to three terminals.
32Supply and fix steped type electronic fan regulator flush type, 230 volt, AC complete.
33S & F bell push, flush type, 5 Amps.
34S & F in repair call bell AC, 230 volts single pole
35S & F Modular Switch 1 way 6 Amps 1 Mopdule Make : Anchor /Havells/ Kinjal.
36S & F Modular Socket 6 Amps 2/3 pin combined 2 Module Make : Anchor /Havells/ Kinjal.
37S & F Modular Socket 16 Amps 2/3 pin combined 2 Module Make : Anchor /Havells/ Kinjal.
38S & F metal flush box 1 Module
39S & F metal flush box 3 Module
40S & F metal flush box 4 Module
41S & F metal flush box 5 Module
42S & F metal flush box 6 Module
43S & F white cover plate with frame 1 Module
44S & F white cover plate with frame 3 Module
45S & F white cover plate with frame 4 Module
46S & F white cover plate with frame 5 Module
47S & F white cover plate with frame 6 Module
48S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 10 Amps all as specified and directed.
49S & F in repair MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, TPN 4 way with 200 Amps rated bus bar , 415 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed.
50S & F in repair MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, SPN 4 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed.
51S & F in repair MCB DB for 8 way, double door 240 Volts 200Amps rated bus bar 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed.
52S & F in repair MCB TPN 415 Volt 63 Amps
53S & F in repair MCB SPN 40 Amps, 240 Volts
54S & F in repair MCB SP 40 Amp, AC, 240 volts,
55S & F in repair sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 2.5 Sqmm, 1100 volts grade (FRLS) and one run of 2.5 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through existing conduit complete incl taking down old UNSV wiring from existing concealed conduit/ casing caping all as specified and as directed. (Note :- Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
56S & F in repair sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through existing conduit complete incl taking down old UNSV wiring from existing concealed conduit/ casing caping all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
57S & F in repair sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through existing conduit complete incl taking down old UNSV wiring from existing concealed conduit/ casing caping all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
58M & L for earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB including taking off old uncerviciable Earthing material complete all as specified & as directed
59Supplying and fixing in repair 1100 volts grade 6 sqmm heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular Make- Anchor/Plaza
60Supplying and fixing in repair 1100 volts grade 10sqmm heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular Make- Anchor/Plaza
61Supply and fix in repair surface mounted Mini light LED batten 1 feet with extruded aluminium housing and robust construction 5 Watt system lumen with all accessories if required flexible copper 2 core wire from fitting to ceiling rose all as specified and directed by Engr-in-Charge. Make- Bajaj cat part No-BCLSB 05 WH or equivalant of Wipro/Philips
62Supply and fix in repair surface mounted Mini Mirror light LED batten 2 feet with extruded aluminium housing and robust construction 10 W system lumen with all accessories if required flexible copper 2 core wire from fitting to ceiling rose all as specified and directed by Engr-in-Charge.Make- Bajaj cat part No-BCLSB 10 WH or equivalant of Wipro/Philips
63Supply and fix in repair surface & wall mounted LED batten 4 feet with extruded aluminium housing and robust construction 24 W system lumen including flexible copper 2 core wire from tube light fitting to ceiling rose required length with all accessories all as specified and directed by Engr-in-Charge. Make- Bajaj cat part No-BCLSB 20 WH or equivalant of Wipro/Philips
64S&F in repair LED Bulkhead light fitting 10 Watt Environmental friendly , ultra modern , energy saving , surface mounted , decorative oval bulk haed edge lit LED luminarie comprising of high brightness LEDs including connetcion of fllexible copper wire 2 core from fitting ceiling rose/connection point Make- Bajaj cat part No-BIBWP 10W LED or equivalant of Wipro/Philips
65Supply and fixing in repair LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Please Enable Macros to View BoQ information
66Supply and fixing in repair LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57665249
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Scada System Of Water Supply Installation And Its Connected Items At Af-I And Repair / Maintenance Of Ceiling Fan, Wiring, Panel Sockets At Khambhaliya And Dwarka Under Ge (Af) Jamnagar No.2
Basic Detail
Tender No 8692/E8
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 23 Sep 2026
Submission Date 07 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
72PTenderDocs.pdf
8da8a961-a72a-44a6-82b7-0e4b1946bfd5.html
BOQ_886438.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.