Tender For Repair / Maintenance Of Water Treatment Plant, Swimming Pool, Ci / Di Water Pipelines, Chemical Dosing System, Control Cable Valve Pits Alongwith Certain Other Connected Works And Fire Hydrant System At Af Stn Under Ge (Af) Jamnagar No.2
Tender Overview
Project Description
Tender for Repair / Maintenance Of Water Treatment Plant, Swimming Pool, Ci / Di Water Pipelines, Chemical Dosing System, Control Cable Valve Pits Alongwith Certain Other Connected Works And Fire Hydrant System At Af Stn Under Ge (Af) Jamnagar No.2
BOQ
| Sl. No. | Item Description |
| 1 | M & L for cleaning of swiming pool of capacity 2 Lakh Gallon at depth of 5mtr by removing sludge, mud or any other foreign material from the bottom and internal wall surface of tank by means of wire brush and spraying of cleaned fresh water, bailing out accumulated dirty water inside the tank with pump sets, removal of deposited muds and other sediments, washing of internal surface with sufficient quantity of mixture in suitable proportion (0.10 Kg of bleaching powder will be mix in 1.0 litre water, acid wash of tiles), finally applying two coats of lime washing on entire internal surface of walls, allowing applied coat to become dry and wait for confirmation from MES Staff, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as specified and directed. |
| 2 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out in soft / loose soil complete all as specified and directed. |
| 3 | Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed. |
| 4 | Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed. |
| 5 | S&F in repair GI tubing medium grade, ISI Marked conforming to IS:1239 Part-I 2004, 20mm bore with and including all fittings such as bends, elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 6 | S&F in repair GI tubing medium grade, ISI Marked conforming to IS:1239 Part-I 2004, 25mm bore with and including all fittings such as bends, elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 7 | S&F in repair GI tubing medium grade, ISI Marked conforming to IS:1239 Part-I 2004, 40mm bore with and including all fittings such as bends, elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 8 | S&F in repair GI tubing medium grade, ISI Marked conforming to IS:1239 Part-I 2004, 50mm bore with and including all fittings such as bends, elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 9 | Supply and Fix in repair submersible pump cable, PVC insulated, PVC sheathed, multi stranded copper conductor cable 1100 volts grade and connecting complete including taking out old unsv damaged cable of following sizes:-Make: Finolex / Havells / KEI |
| 10 | 6sqmm 3 core |
| 11 | 10sqmm 3 core |
| 12 | S & F in repair cast iron foot valve confirming to IS:4038 with rubber seating, flanged end complete incl taking out old unsv complete all as specified and directed for the following .Make: Kartar/Venus/Zoloto |
| 13 | 150 mm bore |
| 14 | 100 mm bore |
| 15 | 80 mm bore |
| 16 | M&L for Dismantling of existing defective/unsv squirrel cage induction motor of capacity of 15 HP, three phase, 415 V, 50 Hz, from the foundation, disconnecting the electric connection, coupling pulley, transportation to work shop, seperating the stator and rotor assembly, cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding of stator with super enamelled solid copper conductor (winding wire) of appropriate gauge and size to match with the existing so as to acheive desired RPM, including varnishing, drying, ovening, overhauling, greasing, providing insualtion and reassembling stator and rotor, connecting coils / winding in star and delta mode at the junction box/terminal, fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and directed. |
| 17 | S&F in repair Bronze gate valve class-1 for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed. |
| 18 | S&F in repair Bronze gate valve class-1 for 20mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed. |
| 19 | S&F in repair Bronze gate valve class-1 for 25mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed. |
| 20 | S&F in repair Bronze gate valve class-1 for 40mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed. |
| 21 | S&F in repair Bronze gate valve class-1 for 50mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed. |
| 22 | Supply and fix in repair DOL starter three phase 415v along with short circuit protection connected accessories suitable with for 3 to 5HP motor complete all as specified and directed. |
| 23 | Supply and fix in repair star delta starter three phase 415v along with short circuit protection connected accessories suitable with for 7.5 to 15HP motor complete all as specified and directed. |
| 24 | Material and labour for road cutting through pneumatic tools and compressor machine hardstanding or Bitumin road for any pipe line work coomplete all as specified and directed by Engr in Charge. |
| 25 | S&F in repair PVC 3 Core copper cable 1.5 Sqmm insulated for fixing of junction box to street light fittings complete all as specified and directed Make- Polycab |
| 26 | Supply and fixing in repair outdoor type solar type automatic timer for street light control single phase 230 volt maximum load 3-5 KW 25 Amp rating with hinged LID complete all as specified and directed.Make- Swadeep model No Swadeep-66-3KW1P |
| 27 | Supply and fix in repair MS pipe medium grade of size 80mm dia, thickness shall not be less than 4.05mm for suction line of pump, header of pumps and connecting to exisiting pipe line including cutting, fabrication work and including weliding work fixing with exisiting pipe line like suction pipe of all motor pumps with all fittings complete all as specified and directed. |
| 28 | Supply and fix in repair MS pipe medium grade of size 100mm dia, thickness shall not be less than 4.05mm for suction line of pump, header of pumps and connecting to exisiting pipe line including cutting, fabrication work and including weliding work fixing with exisiting pipe line like suction pipe of all motor pumps with all fittings complete all as specified and directed. |
| 29 | Supply and fix in repair MS pipe medium grade of size 150mm dia, thickness shall not be less than 4.05mm for suction line of pump, header of pumps and connecting to exisiting pipe line including cutting, fabrication work and including weliding work fixing with exisiting pipe line like suction pipe of all motor pumps with all fittings complete all as specified and directed. |
| 30 | Material & Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed. |
| 31 | Material & Labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed. |
| 32 | Material & Labour for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed. |
| 33 | S&F in repair cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. |
| 34 | Supply and mixing TCCA 90 (Trichloroisocyanuric acid) granular for water purification and chlorinelevel control of swimming pool water complete all as specified and directed. |
| 35 | Supply only POOL Shark chemical for swimming pool as per sample as per direction of Engr in Charge . |
| 36 | Supply and mixing potash alum crystal type or water soluble alum crystals as flocculant for water purification of swimming pool water complete all as specified and directed. |
| 37 | Supply and mixing blue crystal copper sulphate to maintain PH value and visibility of swimming pool water complete all as specified and directed. |
| 38 | Supply and mixing alum (Liquid aluminium ) of good quality for water purification of filtration plant water complete all as specified and directed. |
| 39 | S&F in repairs and install Swimming pool sand filter Top-mount sand filter with a multiport valve , 450 mm (17.7 inches), suitable for small to medium-sized pools Filter Height Approximately 650–750 mm (25.6–29.5 inches) Sand Capacity Around 100–150 kg. Flow Rate Up to 8–12 cubic meters per hour (2,120–3,170 gallons per hour). Connection Size Typically 1.25 to 1.5 inches Build Compact, durable, and weather-resistant construction designed for easy operation and maintenance with multi port valve complete all as specified and directed. |
| 40 | S&F in repairs and install Dosing system (Dual tank Model No- FTPS AQUA 1005 & 1006) Mechancally actuated , variable eccentric type motor dosing system . High flow rate of 0-30 LPH & High pressure of 10kg/cm2 . Flanged vertically Mounted with TEFC induction Motor Directly coupled.Motor capacity 0.25HP , 1440 RPM . Including accessories injection check valve (1/2\\" NPT -M \\"Y\\" strainer 1/2\\" BSP-F) , Suction Strainer (Y Type PP/PVC) and Discharge tubingh 3Mtrs . Accessories must include the following :- (A) Preparation tank Model No AQUA1005 of net capacity 170ltrs . FRP dosing tank dia 650xnet Height 375 + conical 300mm . gross Height with stand 1000mm consisting of water inlet line , outlet with \\"Y\\" stariner . Drain overflow conical bottom for sludge deposition , Pot hole with cover , Level gauge Agitator 120Watt 960RPM single phase flange mounted motor with plastic shaft and impeller (B) Service Tank Model NOAQUA1006 of net capacity 100ltrs of FRP dosing tank Top dia 540mm x Bottom dia 480mm x Height 575mm consisting of water inlet line , Dosing pump inlet arrangement , Drain Ocverflow level gauge , inspection port , Agittator 120Watt 960RPM single phase flange mountred motor with plastic shaft and impeller .Provision of mounting lid .Pump fitted with mounted on heavy duty MS fabricatyed frame and painted with anticorrosive paint Make- Aquafit of Aquajio Technoliogies and MAIC India |
| 41 | S&F in repairs and installation, testing, commissioning, factory made CPRI approved, outdoor type feeder pillar box, of size not less than 600mmx300x450mm made out of 3.15mm thick CRCA sheet, 415volts, 3 phase, 50Hz supply mounted on and including MS angle section 40x40x5mm thick MS frame with frant and back openable, double door with provision of locking arrangement dust proof, gasket, TPN busbar capacity 100 Amps shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall power coated complete all as specified and directed & consisting of the following equipment including taking out old unserviceable:- Incoming (i) MCCB 4 Pole, 32 KA, 250 Amps 415 Volts extended terminals, fixed setting type -01 Nos (ii) Out going MCCB 16 KA 120 Amps -02 Nos (iii) Digital Volt/Ammeter -01 (iv) Seletor switch -01 (v) RYB Indicators (vi) Single phase opreventor -01 set (vii) Star Delta starter of capcity submericble motor complete assemby fixing arrangement inside of LT panel board Make- L&T Model MG15 FASD - 02 Nos (Location - swiming pool ) |
| 42 | Material and labour for servicing of existing fire hydrant sluice valves of dia 100mm replacemnt of rubber gasket , spindle, bronze gate and suitable rubber washer and applying greasing and oiling of complete all as specified and directed by Engr in Charge . |
| 43 | Supply and fix in repair 63mm dia 30m long hose pipe conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed. |
| 44 | Supply and fix in repair fire hydrant landing valve type (single head outlet) of 63 mm dia of size confirming to IS 5290 complete all as specified and directed. |
| 45 | Supply and fix in repairs ose box made of 18 gauge MS Sheet 900mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard |
| 46 | Supply and fix in repair 63 mm dia gun metal branch pipe and nozzle short/long confirming to IS 903 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender