Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57665224

Tender For Provn Of Sheds Including Electrification At Various Locations Under Ge (Af) Marathahalli Bangalore.

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
38.83 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
11 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Sheds Including Electrification At Various Locations Under Ge (Af) Marathahalli Bangalore.

BOQ

Name of Work:- PROVN OF SHEDS INCLUDING ELECTRIFICATION AT VARIOUS LOCATIONS UNDER GE (AF) MARATHAHALLI BANGALORE.
Sl. No. Item Description
1Surface excavation n exc 30 deep avg 15 cm getttin out hard soil/dense soil complete all as specified and directed.
2Excavating post holes in soil/dense soil (or similar holes) each n.exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, complete all as specified and directed by Engineer-in-charge.
3M&L PCC 1:3:6 type C2 as in foundation filling and post holes complete all as specified and directed.
4M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard and dese soil complete all as specified and directed.
5M&L for Pre-cast cement concrete laid in cement mortar (1:6) type B1 1:3:6 (20mm graded aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed.
6Material and Labour for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throating etc. including necessary form work complete all as specified and as directed.
7M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
8M&L Removing excavated material exc. 1.5 km and not exc 5.0 km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
9Rendering 15mm thick cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smooth without using extra cement complete all as specified and directed.
10M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified and directed.
11M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm / 450x350x7mm, as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:3 complete all as specified & directed.
12M&L for Reinforced cement concrete 1:2:4, type B1 (using 20mm graded stone aggregates) as in slab supported on wall, beam ,roofs, landing, chajja, shelves etc all as specified and as directed.
13M&L for mild steel bars 10 mm dia and over TMT bar, cut to length bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed.
14M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels for flat rough finished surfaces of concrete.
15M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs landing and similar work not exc 200 mm thick, with supports and rough finished surfaces of concrete .
16M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and including screed bed of 20mm thick in cement motar (1:4) with pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
17Rounding to edges of stones slabs one edges,such as in steps, cooking platforms and similar situations all as specified and directed.
18Excavating over areas not exc 1.50m deep and getting out in hard/dense soil all as specified and as directed.
19M&L Hardcore of broken stone or boulder gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
20M & L for Cement concrete in foundations, filling and mass concrete Type C2 1:4:8 (40mm graded aggregate) all as specified and as directed.
21M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick,industrial type coloured, Pre polished,set, jointed and pointed in neat cement slurry with gray cement and pigments in floors incl. 20mm thick screed bedding layer in cm 1:4. all as specified and as directed.
22M&L for PCC type B1 1:2:4 (20mm graded aggregate) as in copings, bed plates, kerbs incl necessary formwork etc all as specified and directed..
23S&F Structural steel works as roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc conforming to Fe-410-W (Gde-E-250) quality A, Complete all as specified and directed.
24S & F Pre-painted galvalum aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength as in roof covering/clading to wall, fixing, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering all as directed at site all as specified and directed.
25M & L for preparation of new steel surfaces of any description over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer completed all as specified and directed.
26Removing excavted material n exc 50 m and depositing where directed at level n exc 1.5 m above the staring point as soilcomplete all as specified and as directed by Engineer in charge.
27M & L for RCC 1:2:4 type B-1, using 20 mm graded stone aggregate as in column footing including raft footings, foundation, plinth beam, bases of columns etc. complete all as specified and directed.
28Use and waste form work to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical surfaces complete all as specified and directed.
29M & L RCC Type B1 1:2:4 (20 mm graded aggregate ) as in Columns, pillars, piers, posts and struts etc complete all as specified and directed.
30M & L use of Formwork to sides of pillars, posts, struts, piers, columns, and stanchions of square, rectangular type etc complete all as specified and directed.
31Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders etc.
32M & L Plastering 15 mm thick in in Cement Mortar 1:4 on Fair Faces of Brick Wall, Cement block wall or on Concrete Surfaces, Surface Finished Even and smooth without using Extra Cement complete all as specified and as directed.
33S & F Joist, channel, angle, Tubes or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) ®c complete using EWR or inducton butt welded tubes conforming to Fe410-W (Gde- E-250) quality A complete all as specified and directed.
34M & L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes , including bending of tube/trusses for semicirular type truss in reqired conforming to I. S.1161-1979 grade St.-240
35M & L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde-E- 250)quality-A including bending of tubes, angles, as required shape of shed complete all as specified and directed.
36S & F Plates (plain or chequered) channels , square or beams cut or notched (ordinary and counter sunk) forming holes, without any attachments or with rivited, bolted ot welded attachments, etc confirming to Fe 410-W(Gde-E-250)quality-A complete all as specified and directed. Note - cutting to require size and welding or boulting to Beam , post, rafter shall be at site, rate included in this item.
37S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified.
38S & F Pre-painted galvalum aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength as in roof covering/clading to wall, fixing as in courevd shape / semi circular shape on roof covering as per required on ground , it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering all as directed at site all as specified and dircted.
39M & L 20 mm Dia Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, length of bolts exc 15 cm l and n exc 30 cm long fixing/ embeded to cement concrete surface to hold MS post complete all as directed and specified.
40S & F 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and directed
41S & F 110 mm dia PVC (SWR) bends of any radius with access door complete all as specified and directed
42S & F 110 mm dia PVC (SWR) junction single T equal or un equal complete all as specified and directed
43M & L 3 mm thick ACP sheet fixed over aluminium Rectngular tube section of size 50 mm 25 mm x 2.0 mm thick with self taping screws , aluminium frame work shall be fixed on MS Tube post as in square/rectangular/circular shape , corners / joints should be filled with appropriate material to match the surface complete all as specified and directed.
44Supply , fixing LED highbay lights 100 watts with housing IP-65and IK 07, circular high pressure die cast aluminium housing and manufacture logo embossed on the housing and high transmittance tempered glass cover, optics lens with lens plate having NB and WB optics , system efficacy>120 lumens /watt, xitanium driver-IP 66 complying to IEC61347-2-13 certification like CE ENEC, ROHS, with rated life of 50000 hrs for driver at TC-80 degree C along with all safely features , thermal protections, protection against input over voltage< 320 volt Ac for 48 hrs , driver failure rate ,0.2% per 1 Khr @ TC 70-80 Deg C, wattage 100 Watts , internal wiring-teflon SDCM<5, CCT -5700, CRI>80, THD<20 at max load , third harmonics <20%, PF>.95 colour temperature 6500k, including all accessories necessary for mounting and installation of luminaires all are specified and as directed
45S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
46M & L for sub main wiring complete with two runs of 2.5 sqmm FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 1x2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
47S & F in repair MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
48S & F in repair MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent
49M & L for sub main wiring complete with three runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
50Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
51M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the following:-
52S & F modular socket 06/16 Amps 2/3 pin 2 module complete all as specified & directed.
53S&F modular White cover plate with frame 3 module complete all as specified & directed
54S&F modular metal flush box 3 module complete all as specified and directed.
55Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
56S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
57M & L for sub main wiring complete with two runs of 2 x 1.5 sqmm FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 1x1.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
58Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore light gradeGI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009.
59Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables ( heavy duty) 1100 volts grade with standered aluminium conductor of following sizes Complete all as specified and directed by EIC(a) Size 120 sq mm 3.5 core
60(b) Size 50 sq mm 3.5 core
61(c) Size 10 sq mm 4 core
62Design , fabricating , supply,installation ,testing & commissioning of LT outdoor panel board 3 phase 4 wire system outdoor double door front and back opening type slopped canopy (hood ) on top extended 100 mm al around separate compartment for each control gear cable alley , provn of knock out type plates for various sizes of cable up to 150 sqmm 3.5 core in and out incomming and outgoing feeders duly marked, CPRI type tested fabricated out of 3.15 mm thick CRCA sheet painted with epoxy powder coated mat finish pre wired with PVC insulated multi stranded copper conductor for controls and monitors , PV sleeved mounted on angle iron frame of 40x40x5 mm thick embded in pcc 1:3:6, 45 cm below ground level & 15 cm above ground level consisting of following and complete all as specified and as directed by Engineer in charge .- (a)Aluminium bus bar of 200 Amps capacity duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of class “F” class insulator(b)4 Pole MCCB 125 Amp 50 Hz 415 V with rupturing capacity 36 KA. (Incoming)-01 Nos(c)4 Pole MCCB 63 Amp 50 Hz 415 V with rupturing capacity 16 KA- 02 Nos(d)4 Pole MCB TPN (40 Amps-3 Actual ,Spare -01)(e)Multifunctional Meter (LED Display) to read KWH,AMPS,Volts and frequency etc (f)Selector switch-1No(g) Indication lamps-3 Nos Please Enable Macros to View BoQ information
63Design , fabricating , supply,installation ,testing & commissioning of LT outdoor panel board 3 phase 4 wire system outdoor double door front and back opening type slopped canopy (hood ) on top extended 100 mm al around separate compartment for each control gear cable alley , provn of knock out type plates for various sizes of cable up to 150 sqmm 3.5 core in and out incomming and outgoing feeders duly marked, CPRI type tested fabricated out of 3.15 mm thick CRCA sheet painted with epoxy powder coated mat finish pre wired with PVC insulated multi stranded copper conductor for controls and monitors , PV sleeved mounted on angle iron frame of 40x40x5 mm thick embded in pcc 1:3:6, 45 cm below ground level & 15 cm above ground level consisting of following and complete all as specified and as directed by Engineer in charge .- (a)Aluminium bus bar of 200 Amps capacity duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of class “F” class insulator(b)4 Pole MCCB 125 Amp 50 Hz 415 V with rupturing capacity 36 KA. (Incoming)-01 Nos(c)4 Pole MCCB 63 Amp 50 Hz 415 V with rupturing capacity 16 KA- 02 Nos(d)4 Pole MCB TPN (40 Amps-3 Actual ,Spare -01)(e)Multifunctional Meter (LED Display) to read KWH,AMPS,Volts and frequency etc (f)Selector switch-1No(g) Indication lamps-3 Nos Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57665224
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.83 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Sheds Including Electrification At Various Locations Under Ge (Af) Marathahalli Bangalore.
Basic Detail
Tender No GE (AF) MARATHAHALLI / 8873 / E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 23 Sep 2026
Submission Date 14 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 38.83 Lakhs
Tender Fee 500
EMD 78000
Exemption Available
Document List
3ee7b666-24ad-4f14-a66a-c8f7407d1e13.html
BOQ_886486.xls
TENDER8873.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

3ee7b666-24ad-4f14-a66a-c8f7407d1e13.html

xls

BOQ_886486.xls

pdf

TENDER8873.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders