Tender For Provision Of Recoil Sytem, Resuperator Room For Eqpt Division At Tech Area Taku Cpe Itarsi Under Ge Bhopal
Tender Value
15.76 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
15 days left
EMD
32000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshangabad → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Recoil Sytem, Resuperator Room For Eqpt Division At Tech Area Taku Cpe Itarsi Under Ge Bhopal
BOQ
| Sl. No. | Item Description |
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out Hard/dense soil all as per specified and directed. |
| 3 | Removal of excavated material to a distance n. exc 50 m depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Excavating over areas, exc 1.5 m deep and getting out soft/loose soil as per complete all as specified and directed. |
| 5 | M & L for PCC bed (1:4:8) type D-2 (using 40 mm graded stone aggregate) cement concrete in in foundations, filling and mass concrete etc complete all as specified and directed. |
| 6 | M&L for reinforced cement concrete (Design Mix M-25) (using 20mm stone graded aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 8 | M&L for reinforced cement concrete (Design Mix M-25) (using 20mm graded stone aggregate) columns, pillars, piers, posts and strutscomplete all as specified and directed. |
| 9 | Use & waste formwork to sides of pillars, posts, struts, piers, columns with fair finished surfaces and stanchions complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete (Design Mix M-25) (using 20mm graded aggregate Beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and directed. |
| 11 | Use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 12 | M&L for reinforced cement concrete (Design Mix M-25) type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 13 | Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 14 | M&L for reinforced cement concrete (Design Mix M-25) (using 20mm graded stone aggregate) Chajjas, shelves complete all as specified and directed. |
| 15 | Use & waste formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. |
| 16 | S&F mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns ,footings , slabs hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 17 | All as per item 15.00 here-in before but 8 to 10 mm dia as in stirrups, spaces and binders, complete all as specified and directed. |
| 18 | M&L for brick work with subclass ‘B’ bricks,straight or curved onplan exc 6m mean radius, built in, built in CM 1:6 complete all as specified and directed. |
| 19 | M&L for 20 mm thick damp proof course in cement motar 1:2 to horizontal or vertical surfaces including necessary formwork, complete all as specified and directed. |
| 20 | M&L rendering 15 mm thick in CM(1:6) on fair faces of brick work or concrete surfaces of wall of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L rendering 15 mm thick in CM(1:4) using WPC in on other than fair faces of brick work or concrete surfaces of wall of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 22 | M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) surface even and smooth without using extra cement and necessary scaffolding all as specified and directed. |
| 23 | M&L for preparation of newly plastered surfaces of Wall & applying two coats coats of OBD over a coat of primer complete all as specified and directed. |
| 24 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces, complete all as specified and directed. |
| 25 | M&L for preparation of new plastered surfaces of ceiling & applying two coats of white wash complete all as specified and directed. |
| 26 | M&L for moorum filling in floors laid in layers n exc 25cm thick spread levelled and rammed including watering etc complete all as specified and directed. |
| 27 | M & L for 100 mm thick PCC 1:4:8 type D 2 as in sub base under floors complete all as specified and directed. |
| 28 | M&L for 150 mm thick cement concrete (1:2:4) type B-1 using (20 mm graded crushed stone aggregate) as in sub base of flooring,surface finished rough to receive floor topping complete all as specified and directed. |
| 29 | M&L for 75 mm thick PCC 1:3:6 type C 2 (using 40 mm garded aggregate) as in plinth protection complete all as specified and directed. |
| 30 | S&F for 30 mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 31 | S&F for 105x60mm pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS bar/flat at bottom of the frameetc, including wooden texture finished paint on the frame surface, complete all as specified and directed. |
| 32 | S&F for 200 mm long aluminum anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 33 | S&F for 200mm long extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 34 | S&F 300 mm long Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedmild steel all as specified and directed. |
| 35 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 36 | M&L for preparation of new untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed. |
| 37 | Returning filling in including spreading ,levelling watering and well rammimg of soft/loose soil inlayeres nexc 25 cm thick, complete all as specified and directed. |
| 38 | M&L for providing water proofing treatment with polymeric standard water proofing membrane complete all as specified and directed.. (Note:- (a) Applying 15 mm thick plaster in cement mortar (1:3) using water proofing compound to roof and similar work finished the surface even and smooth without using extra cement. (b) Applying evenly a tack coat of industrial bitumen 85/25 @1.20 Kg/sqm.(c) Supplying and laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including coping on the surfaces with torch application of membrane with 10cm over laps as required.(d) Applying two coats of aluminium paint @ 0.2 kg/sqm complete all as directed. (e) Ponding test shall be done for 24 hrs. |
| 39 | Excavation in trenches n. exceeding 1.5m wide and n. Exc 1.5 mtr in depth, for foundation etc, for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 40 | M&L for PCC 1:3:6, type C-1, using (using 20mm graded stone aggregate) in cement concrete insurface channels and drains including formwork complete all as specified and directed. |
| 41 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement , including forms, moulds mitred/stopped ends etc., complete all as specified and directed. |
| 42 | M&L for sand cussion 50mm thk under inter locking paver and under cable protection complete all as specified and directed. |
| 43 | M&L machine pressed precast concrete interlocking paver block 80mm thick M-40 grade any shape and size with gray cement & pigment confirming to IS-15658-2006 fixed with grey cement and no pigment complete all as specified and directed |
| 44 | M&L for cement concrete 1:2:4, type B1 (using 20mm graded aggregate) as in Cooping benching and similar work complete all as specified and directed. |
| 45 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 Ton complete all as specified and directed. |
| 46 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA, all as specified and directed. |
| 47 | M&L for concealed Point wiring using approved color coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor, 1.5 sqmm nominal cross sectional area, single core, PVC insulated FRLS cable 1100 Volts grade, PVC conduit medium grade and conduit accessories in wall/roof/floor etc with metal sunken box, modular cover plate for fixing of modular switches, sockets and fan regulators etc, including additional PVC insulated multistranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for one light point/fan point controlled by one switch. |
| 48 | All as per item No. 48.00 here-in before but for One socket outlet 5 Amps controlled by one switch on the same board, complete all as specified and directed. |
| 49 | All as per item No. 48.00 here-in before but for One socket outlet 5 Amps controlled by one switch on independent board, complete all as specified and directed. |
| 50 | All as per item No.48.00 here-in before but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and additional 2.5 Sq mm PVC insulated multistranded copper conductor cable as continuous earth wire complete all as specified and directed. |
| 51 | Supply and Fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN 10A- 20 Amps with complete accessories all as specified and as directed and directed by Engr in Charge as per site requirement. |
| 52 | S&F ceiling rose three terminal complete all as specified and directed. |
| 53 | S&F Modular switch 1 way 6A, 240 volts 1 module complete all as specified and directed. |
| 54 | S&F Modular switch 1 way 16A, 240 volts 1 module complete all as specified and directed. |
| 55 | S&F Modular socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 56 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 57 | S&F Modular fan step regulator, 100W, 240 volts 2 module complete all as specified and directed. |
| 58 | Supply and fixing ceiling fans complete with aluminium blades, with remote, anti dust down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed |
| 59 | S&F 1 x 20 Watt LED tube light fitting polycarbonated housing prewired with all accessories 4 feet long, PF>0.9 and efficacy 100 lm/Watt, inlcuding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 1.50 Sqmm complete all as specified and directed. |
| 60 | S&F in repair and replacement of sheet metal enclosure MCB DB 4 way triple pole and neutral 415 Volts leased in wall and all as per IS-8623, complete, cutting of wall, complete all as specified and as directed. |
| 61 | S & F in repair and replacement of MCB single pole 240 volts 6 to 40 Amps complete complete all as specified and as directed. Note: MCB shall be of 10 kA breaking capacity having 'B' curve characteristics as per IS-8828, wiring cable shall be connected to MCB's with suitable copper lugs |
| 62 | S & F MCB in repair and replacement of SPN 240 volts 16 to 40 Amps complete complete all as specified and as directed. Note: MCB shall be of 10 kA breaking capacity having 'B' curve characteristics as per IS-8828, wiring cable shall be connected to MCB's with suitable copper lugs |
| 63 | S & F MCB in repair and replacement of TPN 63 Amp 440 Volts complete all as specified and as directed. Note: MCB shall be of 10 kA breaking capacity having 'B' curve characteristics as per IS-8828, wiring cable shall be connected to MCB's with suitable copper lugs. |
| 64 | M&L for earthing complete with galvanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground levels) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nut, bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber, reassed for and including PCC (1:3:6) type C1 earthing chamber, RCC cover (1:2:4) 50 mm thick, reinforced with 6 mm TMT bar at 50 mm c/c, handle made with MS 10 mm bar, funnel, wire mesh including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Pt-I 1991 print and as directed. Note:- (i) Item of earthing includes cost of excavation, removing, PCC Chamber, 15mm bore medium grade GI protection Pipe (7.5 Meters long) for earth lead any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25% (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of Engr-in Charge. |
| 65 | S&F in repair and replacement of Building Security light fitting LED 35 Watt energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with toughened glass and impact resistance PF IK08 and GI pipe 32/40 mm dia, light grade for mounting bracket bent to shape 1.20 RM and fixing arrangement with two Nos of MS clamps set, nut bolts, washers of suitable size and fixing on wall/pole complete complete all as specified and as directed. |
| 66 | Materials & labour in replacement of 1100 volts grade heavy duty XLPE cable of size 35 Sqmm 3.5 core, passing through GI pipe with aluminium conductor stranded polyethylene insulated, conductor served with and including sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete including taking down existing unserviceable UG cable of any type and size all as specified and directed. |
| 67 | Supplying and laying Class LV, Type I, flat, size 250mm x 150mm x 40mmfor cable protection cover as per IS 5820 , laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 68 | M & L of GI pipe light grade 50mm dia bore with all fittings and fixed complete to wall, to pole or laid in trenches and road crossing complete including taking down unserviceable GI pipe of any size all as directed. |
| 69 | Supply, jointing, testing end termination jointing kit heat shrinkable out door type, suitable for LT 1100 Volts grade cable of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 70 | M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including filling at road cuttings or making pillars for supporting pipe including necessary form work complete all as specified and directed. |
| 71 | Deduct Schedule of credit (calculation will be done off line) Rs. 57988.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender