Rural Development Government Departments Closing in 3 days TDR #57664468

Tender For Construction Of 8 Nos. Residential Staff Quarter E Type At Tahasil Office,Building Bhatli In The District Of Bargarh For The Year 2025-26.

Issued by Government Departments · Bargarh, Odisha
Tender Value
2.44 Crore
Estimated cost
Bid Submission
06 Oct 2026
3 days left
EMD
2.44 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bargarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 8 Nos. Residential Staff Quarter E Type At Tahasil Office,Building Bhatli In The District Of Bargarh For The Year 2025-26.

BOQ

Name of Work:- Construction of 8 Nos. Residential Staff Quarter E Type at Tahasil Office,Building Bhatli in the district of Bargarh for the year 2025-26.
Sl. No. Item Description
1Earth work in excavation of foundation in hard soil or gravelly soil within 50 m initial loead and initieal lift, including dressing and levelling the bed etc. complete
2Earth work in excavation of foundation in hard soil or gravelly soil within 50 m initial loead and initieal lift, including dressing and levelling the bed etc. complete Compound Wall
3Supplying and filling foundation and plinth with sand wall watered and rammed with cost conveyance and royality, taxes of all materials and labour (T&P) etc. complete.
4Supplying and filling foundation and plinth with sand wall watered and rammed with cost conveyance and royality, taxes of all materials and labour (T&P) etc. complete. Compound Wall
5Cement Concrete (1:3:6) in Foundation using 4 cm size bhg metal including watering, curing with cost, conveyance, royalty and taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge.
6Cement Concrete (1:3:6) in Foundation using 4 cm size bhg metal including watering, curing with cost, conveyance, royalty and taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Compound Wall
7Cement Concrete (1:2:4) with 12mm size hard granite chips using 4 cm size bhg metal including watering, curing with cost, conveyance, royalty and taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge.
8Fly Ash Brick masonry with CM (1:6) in Foundation & Plinth including watering, curing with cost, conveyance, royalty and taxes of all materials & labour (T&P) etc. complete as per the direction of Engineer-in-Charge.
9Fly Ash Brick masonry with CM (1:6) in Foundation & Plinth including watering, curing with cost, conveyance, royalty and taxes of all materials & labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Compound Wall
10Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. Ground floor
11Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. First floor
12Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. Second Floor
13Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. Third Floor
14Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. Compound Wall
15R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Footing
16R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Compound Wall
17R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Plinth Beam
18R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Compound Wall
19R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Column Ground floor
20R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Column First floor
21R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Column Second Floor
22R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Column Third Floor
23R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Column Compound Wall
24R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Lintel Ground floor
25R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Lintel First floor
26R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Lintel Second Floor
27R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Lintel Third Floor
28R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Staircase Ground floor
29R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Staircase First floor
30R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Staircase Second Floor
31R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Roof Slab Ground Floor
32R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Roof Slab First floor
33R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Roof Slab Second Floor
34R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Roof Slab Third Floor
35R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Chajja First floor
36R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Chajja Second Floor
37R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Roof Beam First floor
38R.C.C. M-25 using 20 mm & down size b.h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Roof Beam Second Floor
39Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Ground Floor
40Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. First Floor
41Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Second Floor
42Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Third Floor
43Cutting, Bending, binding and tying the grills and placing in position including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Compound Wall
4416 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Ground floor
4516 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. First floor
4616 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Second Floor
4716 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Third Floor
4816 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Compound Wall
4912mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Ground floor
5012mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. First floor
5112mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Second Floor
5212mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Third Floor
5312mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. Compound Wall
546mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment Ground floor
556mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment First floor
566mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment Second Floor
5720mm thick cement plaster in C.M. ( 1:4) for Grading plaster with all cost conveyance etc. complete. Third Floor
58Cement washing one coat including scaffolding and cleaning the surface before application. Ground floor
59Cement washing one coat including scaffolding and cleaning the surface before application. First floor
60Cement washing one coat including scaffolding and cleaning the surface before application. Second Floor
61Cement washing one coat including scaffolding and cleaning the surface before application. Third Floor
62Cement washing one coat including scaffolding and cleaning the surface before application. Compound Wall
63Wall Priming one coat with any approved primer on New Plastered surface of with any approved primer including cost of primer etc. complete Ground floor
64Wall Priming one coat with any approved primer on New Plastered surface of with any approved primer including cost of primer etc. complete First floor
65Wall Priming one coat with any approved primer on New Plastered surface of with any approved primer including cost of primer etc. complete Second Floor
66Wall Priming one coat with any approved primer on New Plastered surface of with any approved primer including cost of primer etc. complete Third Floor
67Wall Priming one coat with any approved primer on New Plastered surface of with any approved primer including cost of primer etc. complete Compound Wall
68Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Ground Floor
69Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. First Floor
70Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Second Floor
71Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Third Floor
72Finishing out side wall surface with Weather Coat (I.S.I) two coats over a coat of primer with any approved shade including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Compound Wall
73Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. Ground Floor
74Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. First Floor
75Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. Second Floor
76Distempering two coats to walls with distemper of approved shade on new work to give an even shade including cost of distemper etc. complete as per specification and direction of the Engineer-in-charge. Third Floor
77Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.Ground Floor
78Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.First Floor
79Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.Second Floor
80Applying Acrylic Wall Putty (Water Based) to wall surface including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge.Third Floor
81Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete.Ground Floor
82Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete.First Floor
83Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete.Second Floor
84Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete.Third Floor
85Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete.Compound Wall
86Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour completeGround Floor
87Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour completeFirst Floor
88Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour completeSecond Floor
89Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour completeThird Floor
90Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour completeCompound Wall
91Priming one coat with any approved primer including cost of primer to iron and wood work etc. complete.Ground Floor
92Priming one coat with any approved primer including cost of primer to iron and wood work etc. complete.First Floor
93Priming one coat with any approved primer including cost of primer to iron and wood work etc. complete.Second Floor
94Priming one coat with any approved primer including cost of primer to iron and wood work etc. complete.Third Floor
95Priming one coat with any approved primer including cost of primer to iron and wood work etc. complete.Compound Wall
96Supplying, fitting, fixing up window/Door (sliding type) made up aluminum Section 151-154,151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc.complete as per direction of Engineer-in charge.Ground Floor
97Supplying, fitting, fixing up window/Door (sliding type) made up aluminum Section 151-154,151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc.complete as per direction of Engineer-in charge.First Floor
98Supplying, fitting, fixing up window/Door (sliding type) made up aluminum Section 151-154,151-155, as windows frame section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc.complete as per direction of Engineer-in charge.Second Floor
99Supplying fitting and fixing of 125mm x 63 mm Sal wood chaukhatasFirst Floor
100Supplying fitting and fixing of 125mm x 63 mm Sal wood chaukhatasSecond Floor
101Fitting and fixing of WI clampFirst Floor
102Fitting and fixing of WI clampSecond Floor
103Providing & fixing of 30-32 mm thick flush door BWR ply with both side decorative of approved quality and make with the all hardware i.e.4\\" ball in bearing hings, scew, tower, bolt, door stopper etc. complete as per direction of E.I.C.First Floor
104Providing & fixing of 30-32 mm thick flush door BWR ply with both side decorative of approved quality and make with the all hardware i.e.4\\" ball in bearing hings, scew, tower, bolt, door stopper etc. complete as per direction of E.I.C.Second Floor
105Supplying, Fitting & Fixing of F.R.P Doors With Frames including all materials, labour etc. complete.First Floor
106Supplying, Fitting & Fixing of F.R.P Doors With Frames including all materials, labour etc. complete.Second Floor
107Supplying, fitting and fixing of Vetrified Tile in floors of size 600mm x 600mm (plain Ivory) of approved make conforming to IS:13755 laid on 20 mm thick cement mortar and filling joins with white cement of approved quality including cost of all materials, labour T&P etc required for the works all complete as per direction of Engineer-in-charge. Ground floor
108Supplying, fitting and fixing of Vetrified Tile in floors of size 600mm x 600mm (plain Ivory) of approved make conforming to IS:13755 laid on 20 mm thick cement mortar and filling joins with white cement of approved quality including cost of all materials, labour T&P etc required for the works all complete as per direction of Engineer-in-charge. First Floor
109Supplying, fitting and fixing of Vetrified Tile in floors of size 600mm x 600mm (plain Ivory) of approved make conforming to IS:13755 laid on 20 mm thick cement mortar and filling joins with white cement of approved quality including cost of all materials, labour T&P etc required for the works all complete as per direction of Engineer-in-charge. Second Floor
110Providing and fixing 20mm thick Granite stone in floor and Skirting (sample of sample of stone should be approved by EIC) for any similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 25mm thick bed of cement mortar 1:1 (1 cement: 1 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-In-Charge. In all floors and all heights First Floor
111Providing and fixing 20mm thick Granite stone in floor and Skirting (sample of sample of stone should be approved by EIC) for any similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 25mm thick bed of cement mortar 1:1 (1 cement: 1 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-In-Charge. In all floors and all heights Second Floor
112P.V.C Rain Water down pipes providing at top of the roofs First Floor
113P.V.C Rain Water down pipes providing at top of the roofs Second Floor
114Supplying ,fitting ,fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32x32x2mm @0.90 mtr. C/C and stainless square pipe bracing of size 32x32x2mm in 3 rows in stair case as per approved design and specification, buffing , polishing etc with cost, conveyance, taxes of alll materials, labour, T&P etc required for the coplete in all respect.(Ground Floor) Ground floor
115Supplying ,fitting ,fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32x32x2mm @0.90 mtr. C/C and stainless square pipe bracing of size 32x32x2mm in 3 rows in stair case as per approved design and specification, buffing , polishing etc with cost, conveyance, taxes of alll materials, labour, T&P etc required for the coplete in all respect.(Ground Floor) First Floor
116Supplying ,fitting ,fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32x32x2mm @0.90 mtr. C/C and stainless square pipe bracing of size 32x32x2mm in 3 rows in stair case as per approved design and specification, buffing , polishing etc with cost, conveyance, taxes of alll materials, labour, T&P etc required for the coplete in all respect.(Ground Floor) Second Floor
11725mm thick Grading Concrete (1:2:2) using 4.7mm size b.h.g. chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. First Floor
11825mm thick Grading Concrete (1:2:2) using 4.7mm size b.h.g. chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. Second Floor
119Earth work in stoney earth and gravels mixed with stone and boulder not exeeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.(a) Initial lift upto 1.50m
120Earth work in stoney earth and gravels mixed with stone and boulder not exeeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department (b) From 1.50m to 3.00m depth
121Supplying all materials labour T&P and filling foundation and plinth with river sand well watered and rammed including conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per the direction of E.I.C.
122Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C.(a)110mm dia pipe
123Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (b)75mm dia pipe
124Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (d)110mm dia D/J with Door
125Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (e) 110mm dia P- Trap
126Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (f) 110mm dia Plain shoe bend
127Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (g)110mm dia Door Bend
128Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (h)110mm dia Offset
129Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (i)110mm dia Plain bend
130Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (j) 110mm dia cowl
131Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (l) 75mm dia Door Tee
132Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (m) 75mm dia Door Bend
133Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (n) 75mm dia offset
134Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (o) 75mm dia plain Bend
135Supplying all materials labour T&P and fitting & fixing u-PVC ventilating pipes and fittings of the following O.D conforming to ISI No.13592 /1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method / as per manufacturers specification testing e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. (p) 125mm dia C.P. Grating
136Supplying all materials labour T&P and fixing water closet, squatting pan (Indian type W.C. pan /Orissa pattern squatting pan) duly embedded in cc(1:5:10) using 4cm h.g. metal all complete as per the direction of E.I.C.(a) 580mm Orissa pan (make- Cera, Parryware, Hindware)
137Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) etc all complete as per specification and direction of the E.I.C.white vitrous china wash down water closet(E.W.C) with 'S' trap with seat cover
138Supplying all materials, labour, T & P and fixing kitchen sink with hole for pillar taps with C.I./M.S. brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C.(a) 600mm x 450mm x200mm Steel sink with 40mm dia c.p. west, west pipe and brackets.
139Supplying all materials, labour, T & P and fixing wash basing with hole for pillar taps with C.I./M.S. brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C.(a)550mm x 400mm W.H.B. with 32mm dia c.p. west, west pipe , brackets and connection pipe . (make- Cera, Parryware, Hindware)
140Supplying all materials, labour, T & P and fixing wash basing with hole for pillar taps with C.I./M.S. brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C. (b)Pedestrial for W.H.B. (make- Cera, Parryware, Hindware)
141Supplying all materials, labour T & P and fixing mirror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden plugs with C.P. screws and washers complete as per P.H. specification and direction of E.I.C.(a) 600mmx450mm B.E. Mirror
142Supplying all materials, labour T & P and fixing standard size glass shelf with C.P. brass brackets and guard rail complete fixed to wooden plugs with C.P. screws as per P.H. specification and direction of E.I.C.(a)(125x600)mm size glass-shelf with C.P Guard rail( make-Parryware)
143Supplying all materials,labour T&P and fixing standard size C.P. towel rail complete with C.P. Brass brackets fixed to wooden plugs with C.P. screws as per P.H. specification and direction of E.I.C.(a)25mmx600mm long C.P. towel rail ( make-Parryware)
144Supplying all materials,labour T&P and fixing standard size C.P. towel rail complete with C.P. Brass brackets fixed to wooden plugs with C.P. screws as per P.H. specification and direction of E.I.C (b)C.P Towel Ring( make-Parryware)
145Supplying all materials,labour T&P and fixing standard size CP soap holder complete with CP Brass brackets fixed to wooden plug with CP screws as per PH. specification and direction of E.I.C.(a)CP Soap holder ( make-Parryware)
146Supplying all materials labour T&P and cutting holes through brick stone masonary walls for taking HCI/PVC and fittings including making good the damages etc. all complete as per P.H. specification and direction of E.I.C.(a) 250mm thick wall
147Supplying all materials,labour,T&P and fixing ceramic tiles/marble tiles/ chequered tile in floors,treads and landing on 25mm thick bed of cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per the specification and direction of E.I.C.(i)1st. Floor :-
148Supplying all materials,labour,T&P and fixing ceramic tiles/marble tiles/ chequered tile in floors,treads and landing on 25mm thick bed of cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per the specification and direction of E.I.C.(ii) 2nd. Floor:-
149Supplying all materials,labour T&P and providing 20mm thicks CP (1:3)on brick/stone work including watering,curing conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
150Supplying all materials labour T&P and providing cement punning for skirting including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
151Supplying all materials labour T&P and fixing porcelain glazed tile/ Marble tiles/Kota tiles/Kodapa tiles in dados skirting and risers of steps on 12mm thick CP(1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C.(a) Wall Tiles:-1st floor
152Supplying all materials labour T&P and fixing porcelain glazed tile/ Marble tiles/Kota tiles/Kodapa tiles in dados skirting and risers of steps on 12mm thick CP(1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C. (b) Wall Tiles:-2nd floor
153Supplying all materials labour T&P & providing factory made FRP alternately called GRP door frame of size 75mm x 100mm fabricated using E glass chopped strand mat CSM UV stabilised Inopthalic Gelcoat and impregnated with Inopthlic resin.The thick ness of the FRP skins shall not be less than 2.00mm.The door frame consist of four segments which are provided wit plug in socket arrangement in-situ in the mould.The segments are plugged in and are joined together by means of screw. he GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for fixing metallic hold fast and shall be consolidated by filling with medium density foam plaster of paris with fibre reinforcement, Six numbers of 260mmx25mmx5mm size S shaped MS flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV TIFAC composites Desing centre s standards and specification and the door shutters tested in conformation to IS 4020-1998.The finish of door frame will be plain colour white/Ivory/ Beige/Light grey/Golden brown/Mahogancy/Teak wook/sand stone /Champagne/Pastel blue or any other colour using high quality pigments complete inall respect as per specification and direction of the Engineer in charge.
154Supplying all materials labour T&P and providing factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.59mm Expanded Polystyrone (EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcement for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) from shall be provided. A structural adhesive comptible with (EPS) foam shall be used for bending the core material, the sal wood reinforcements and the skins. The material and the door shutters tested in conformation to IS:4020-1998. The finish of door shutter will be plain colour white /Ivory/Beige/ Lightgrey/Mahogany/Teak woodor any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to is fitted on one side of shutter etc. complete as per direction of E.I.C..
155S.D. PORTION:- Supplying all materials labour T&P and constructing gully trap chamber of the following inside size with 8cm thick RCC precast coverslab in cc(1:1½:3)using 12mm size hg chips,foundation concrete(1:3:6)using 40mm size h.g. metal on bed and around trap,KB brick in cm(1:6) in F&P and inside 12mm thick CP(1:3) finished with a floating coat of neat cement including fixing 100mm size H.C.I. gully trap and grating etc. all complete as per approved drawing, specification and direction of E.I.C.(a) Inside size 250mm x 250mm
156Supplying all materials labour T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB brickwork in cm(1:6)moulding and shaping the channel inside and benching with cc(1:1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside,cement flush pointing(1:3)to outside,RCC coverslab in cc(1:1.5 :3)using 12mm size h.g. chips with R.C.C. man hole cover, e.w. in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.(a) Inside size 760mm x 760mm x 460mm
157Supplying all materials labour T&P and constructing manhole chamber of the following sizes with cc(1:3:6)using 40mm size h.g. metal on bed,1st class KB Brickwork in cm(1:6)moulding and shaping the channel inside and benching with cc(1:1.5:3)using 12mm size h.g. chips,12mm thick CP(1:3)with punning to inside, cement flushpointing (1:3) to outside,RCC cover slab in cc(1:1.5:3) using 12mm size hg chips with RCC manhole cover,e.w. in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site, payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.(a) Inside size 910mm x 910mm x 910mm
158Supplying all labour T&P and constructing soakway pit of the following sizes with drybrick walling from bottom upto invert of inlet pipe and 1st class KB brickwork in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside and outside over masonary brick work,gravel packing in the rear of well steining RCC cover slab in cc(1:1.5:3)using 12mm size h.g. chips fitted handles including e.w. in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron works,wattering,curing, conveyance of all meterails to worksite,payment of royality,taxes etc. all complete as per approved drawing,specification and direction of E.I.C.(a) 1.40m dia x 2.00m deep
159Supplying all labour T&P and constructing soakway pit of the following sizes with drybrick walling from bottom upto invert of inlet pipe and 1st class KB brickwork in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside and outside over masonary brick work,gravel packing in the rear of well steining RCC cover slab in cc(1:1.5:3)using 12mm size h.g. chips fitted handles including e.w. in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron works,wattering,curing, conveyance of all meterails to worksite,payment of royality,taxes etc. all complete as per approved drawing,specification and direction of E.I.C (b) 1.20m dia x 2.00m deep RCC Ring Soakway Pit
160Supplying all materials,labour,T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches(to slope or level) & jointing with supply of approved solvent cement by non-heat application method cc(1:3:6) using 40mm size hard granite metal on bed of the trenches and allround concrete encashing with cc(1:4:8)using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering,ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C.(a) 110mm dia PVC pipe with allround encasing
161Supplying all materials,labour,T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches(to slope or level) & jointing with supply of approved solvent cement by non-heat application method cc(1:3:6) using 40mm size hard granite metal on bed of the trenches and allround concrete encashing with cc(1:4:8)using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering,ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C. (b) 160mm dia PVC pipe with allround encasing
162Supplying all materials labour T& P and providing cc(1:3:6)using 4cm h.g metal including watering, curing, conveyance of all materials to work site, payment of royality, taxes etc. all complete as per specification and direction of E.I.C
163Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm hg chips including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
164Supplying all materials labour T & P and providing brick work with flyash Bricks having crushing strength not less than 75kg. / c.m2 with dimensional tolerance +/- 8% including watering, curing conveyance all materials to worksite payment of royality taxes etc. all complete as per specification direction of E.I.C.(a) Flyash Brick work in cm(1:4) F&P
165Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per specification and direction of E.I.C
166Supplying all materials labour T&P and providing MS reinforcement for RCC work including cutting, bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,conveyance of all materials to worksite,payment of royality, taxes etc. all complete as per specification and direction of E.I.C.
167Supplying all materials labour T&P and providing RCC(1:1.5::3) using 12mm hg chips for RCC works including hoisting,laying, watering,curing, conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
168Supplying all materials labour T&P and fixing MS step iron in 20mm dia MS steel bar and fixing into walls of septic tank duly embedded in cc(1:3:6)all complete as per P.H. specification and direction E.I.C.
169Supplying all materials labour T & P and fixing of R.C.C. baffle wall precast with cc(1:1.5:3)using 12mm bhg chips and fitted to septic tank as per P.H. specification and direction E.I.C.
170Supplying all materials,labour,T&P and providing fitting & fixing PVC Tee in wall including fitting the necessary with cc(1:1.5:3) with 12mm size h.g. chips all complete including watering,curing, conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.(a) 160mm p.v.cTee
171Supplying all materials labour T&P and Providing cement flush pointing(1:3) to brickmasonary including watering,curing, conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C.
172Supplying all materials labour T&P and providing 500x500x100mm thick RCC precast MH cover in cc(1:1.5:3)using 12mm h.g chips placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C
173Filling in foundation & plinth with excavated materials, including watering, and ramming as per direction of E.I.C.
174W/S SUPPLY PORTION:- Supplying all materials labour T&P and constructing bore well protection chamber of the following sizes with cc(1:4:8)using 40mm size hg metal on bed,1st class KB brickwork in cm(1:6), 12mm thick CP(1:4)to inside and out side ove masonary work,RCC coverslab in cc(1:1.5:3)using 12mm size hg chips with e.w.in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.(a)Bore Protection Chamber 500mm x 500mm x 750mm
175Supplying all materials,labour,T&P and construction of masonry staging with providing 1st class KB brickwork in cm(1:6)of 0.46mtr height in staging,12mm CP in cm(1:6),RCC Beam of 0.25mx0.30mx3.18m in cc(1:1.5:3)using 12mm size HG chips including centering,shuttering, bending and binding of rod etc watering,curring, conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C. (a) Stagging for 2000Lit. O.T.(F. Floor)
176Supplying all materials,labour,T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tankconforming to 12701/ 1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.L and placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. (a)2000Lit. Overhead tank (F. Floor)
177Supplying all materials,labour,T&P and fitting & fixing 10ltr. capacity low level flushing cystern with a pair of cast iron or m.s. brackets complete with fittings such as syphonic arrangements 15mm nominal size brass / pvc ball valve with polythene float, c.p. brass handle, union and couplings for connection with inlet, outlet and overflow pipes, 32mm dia c.p. flush bend, 15mm dia, pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C. (a)10Lit. Capacity Flushing cistern (Make- Slimline, Cera,)
178Supplying all materials, labour, T & P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89 (sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C.(a) 20mm dia C-PVC pipe(internal)
179Supplying all materials, labour, T & P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89 (sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C. (b) 25mm dia U-PVC pipe(internal)
180Supplying all materials, labour, T & P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89 (sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C. (c) 32mm dia U-PVC pipe(external)
181Supplying all materials, labour, T & P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89 (sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C. (d) 50mm dia C-PVC pipe(external)
182Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc all complete as per PH specification and direction of E.I.C.(a) 250mm thick wall (1st Floor) :-
183Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc all complete as per PH specification and direction of E.I.C (b) 250mm thick wall (2nd. Floor) :-
184Supplying all materials,labour,T&P cutting holes in RCC floors, roofs etc.up to 19cm thick for passing GI/PVC pipes fittings and reparing the holes after insertion of pipe etc. with cc(1:1.5:3) including finishing so as to make it leak proof as per direction of E.I.C.(a) First Floor:-
185Supplying all materials,labour,T&P cutting holes in RCC floors, roofs etc.up to 19cm thick for passing GI/PVC pipes fittings and reparing the holes after insertion of pipe etc. with cc(1:1.5:3) including finishing so as to make it leak proof as per direction of E.I.C. (b)Second.Floor:-
186Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking G.I/ PVC pipes and making good the damages as per direction of E.I.C.(a) 1st Floor:-
187Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking G.I/ PVC pipes and making good the damages as per direction of E.I.C. (b)2nd . Floor:-
188Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.(a)15mm dia C.P. SB Bibcock (Jaguar make)
189Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (b)15mm dia C.P.L.B. Bibcock (Jaguar make)
190Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (c)15mm dia C.P. Pillar cock Long Neck (Jaguar make)
191Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (d)15mm dia C.P. angle stopcock(Jaguar make)
192Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (e)15mm dia C.P.Two way Bibcock (Jaguar make)
193Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (f)15mm dia C.P. Concealed stopcock(Jaguar make)
194Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (g)15mm dia C.P. Revolving Shower with shower Arm(Jaguar make)
195Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (h)15mm dia Health Faucet & 1.0m long Flexible pipe
196Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (i) 25mm dia U-PVC Ball Valve
197Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (i) 32mm dia U-PVC Ball Valve
198Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (j) 15mm dia C.P. Extension Piece
199Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C (k)15mm dia C.P. Flange
200Supplying all materials,labour,T&P and fitting and fixing of I.S.I. mark 2H.P single phase vertical water cool submersible pump set with discharge 1800/2200Lit./Hour & a head-55/70mtr.of reputed make(CRI/KSB/Texmoor Equivelent)Including cost conveyance and taxes etc. all completes as per P.H. Specification and direction of E.I.C.
201Supplying all materials,labour,T&P and fitting & fixing of 2.0HP single phase vertical submersible pump set with commissioning and testing etc. all completes as per P.H Specification and direction of E.I.C.
202Supplying all materials, labour, T & P and fitting & fixing of I.S.I. mark D.O.L. starter of reputed make like B.C.H. or equivalent for 2HP single phase vertical submersible pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C.
203Supplying all materials labour T&P and fitting & fixing of 2.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/Finolex or equivalent&connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C.
204Supplying all materials labour T&P and fitting & fixing plastic rope with MS well cover,MS Clamp,stainless steel short piece,Bend & socket,union including all cost conveyance & taxes etc. all completes as per P.H. Specification direction of E.I.C.
205Supplying all materials labour T&P and fitting & fixing of H.D.P.E. pipes and pipe fittings with making connection to pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification direction of E.I.C.
206Sinking of 125mmx100mm dia Bore Well through DTH method.- 2 Nos. Labour for drilling of perfactly vertical bore holes as specified dia.For a specified depth below GL level through consolidated and uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs(600cfm/200psi)as required to suit the site conditions as per the direction of E.I.C.including use of own rigs with its accessories,tools & plants and consumable etc. for lowering 125mm dia PVC/ GI pipes for house fitted with socket and with or without well screen as per the necessity for the soft, medium,hard & boulder formation(PCV/GI)casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after complete of tube well.(Tube well-2 Nos.)(a)Drilling of 125mm. dia. Bore-0.00mtr to 30mtr
207Sinking of 125mmx100mm dia Bore Well through DTH method.- 2 Nos. Labour for drilling of perfactly vertical bore holes as specified dia.For a specified depth below GL level through consolidated and uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs(600cfm/200psi)as required to suit the site conditions as per the direction of E.I.C.including use of own rigs with its accessories,tools & plants and consumable etc. for lowering 125mm dia PVC/ GI pipes for house fitted with socket and with or without well screen as per the necessity for the soft, medium,hard & boulder formation(PCV/GI)casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after complete of tube well.(Tube well-2 Nos.) (b)Drilling 100mm dia. Bore-30mtr to 100.00mtr and above
208Lowering the following G.I/PVC pipe with or without soltted pipes as per necessity from ground level upto 30.00mtr depth and fitted and fixed in perfecty vertical position including cutting and threading pipes and soltted pipes and supplying and fixing of all jointing materials,T&P etc the top of the casing pipe threaded including piping tube well to prevent entry of foreign materials from above(PVC/G.I) supplied by the contractor (including cost of pipe)(a)Lowring of 125mm dia pipes-0.00mtr to 30.00mtr
209Lowering the following G.I/PVC pipe with or without soltted pipes as per necessity from ground level upto 30.00mtr depth and fitted and fixed in perfecty vertical position including cutting and threading pipes and soltted pipes and supplying and fixing of all jointing materials,T&P etc the top of the casing pipe threaded including piping tube well to prevent entry of foreign materials from above(PVC/G.I) supplied by the contractor (including cost of pipe (b)Cost of 125mm dia PVC casing pipes-0.00m to 30.60m
210Cleaning&developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of E.I.C.
211Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type -do- (Gr.A) (1.1.1-1.24.2)
212Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type (Gr.B) (1.1.2-1.24.2)
213Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type - (Gr.C) (1.1.3-1.24.2)
214Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type S/F of M.S. Box for 8 Module 18 swg
215Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type S/F of M.s. Box for 2 module 18 swg
216Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type S/F of M.S. Box for 6 Module 18 swg
217Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type S/F of M.S. Box for 4 Module 18 swg
218Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type S/F of M.S. Box for 12 Module 18 swg
219S/F of 3 pin 5/6 A.F.T switch and.Socket on existing board (Modular type) (1.25.1+1.25.4)
220S/Fof 6 module M.S. Box with Bakelite cover (Modular Type) on surface or in recess including providing and fixing of 2 nos 3 pin 5/6 amp. Socket out let 5/6amp. Piano type modular switch,connection,painting etc. as required (1.24.4 +2 x (1.25.1+1.25.4)
221S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
222S/F of A.C.Starter 20Amp with 2 module Box.(Make Havells/Equivalent)
223S/F of 15A Socket on 2 module for AC
224Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White).2x1.5 sqmm + 1 x 1.5 sqmm( 1 .8.1)
225Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White 2 x 2.5 sqmm + 1 x 1.5 sqmm (1.8.2)
226Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White- 2x4 sqmm + 1 x 1.5 sqmm (1.8.3)
227Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White 2x6 sqmm + 1 x 2.5 sqmm (1.8.4)
228Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White S/F of 5 to 32 Amp rating 240 Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution Board ISI marked complete with connection, testing and commissioning etc. as required (2.6.1)
229Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White S/F of 'C' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)Make L&T/Equivalent
230Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White S/F of MCB 8 way Double Door (2.3.6)
231Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White S/F of MCB 4 way double Door (2.3.1(a)
232Supply, Installation and commissioning of63 Amp. I.C.D.P. Main Switches (Sl.No. 1502) (IS 13940 Part 3/ 1993) on existing surface complete with H.R.C. fuse links, interconnections, earthing etc. as requiredas per direction of Engineer in- charge (Make Siemens/ HPL/Anchor/L&T/ Havels/ C&S/ R,K,) 2.15.1A
233Supply of250 mm x 300 mm x100 mm deep(1.24.13) for fixing 63 Amp ICDP Main Switch.
234S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30)
235Supply of 180 mm x 100 mm x 60mm deep (1.24.5) for fixing call bell
236S/F of batten holder BK angle holder ISI marked including connection etc. insulated of ceiling rose(1.29- 1.28)
237Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2+3.3)
238Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17)
239Invertor wiring (1x 1.5 sqmm) copper wire (1.19.1)
240S/F of step type modular fan regulator
241Supply of instalation, Testing commissioning of 13 Watt. LED bulb
242S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
243S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB
244S/F of 18-25 watt LED Tube light fitting compoete with all connection.\ including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL)
245S/F of 2000 VA/24V Inverter with 2 nos. 180 Ah Tall Tubular battery including trolley arrangement (Make: Microtek/V Guard/ Luminous/Exide)
246S/F of 5 kva automatic voltage stabilizer(90-300) with MS angle frame ( Make : Shakti/V-guard/Microtex)
247S/F of 18W Recess Mount(Round/Square) or Surface Type Ceiling light (Havels/crompton/philips/panasonic)
248S/F of 45-48 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection ( Make- Crompton/Phillips/HPL/Polycab/Havells )
249Supply and installation of 7 mtr long hot dip galvanized Octagonal pole having base dia of 175 mm and top dia of 70 mm and plate thickness of 4 mm or more complete with base plate of 250x250x16mm and 4 nos. Jtype En 8 grade foundation bolts M24X750mm to withstand 180 KM / HR wind speed considering the weight. Solar lights fixed on the top of the pole for AIO Integrated Solar lights . One no of AIO Solar lights at a height of 7 mtr above ground .Both the Octagonal pole, En8 grade fdn bolts and bracket must be manufactured in the Octagonal pole manufacturing company. ( Bracket & En8 grade Fdn bolts manufactured by third party pole supplier/manufacturer shall not be acceptable).The necessary test reports of Octagonal Pole and EN8 grade fdn bolts must be submitted by the manufacturer for acceptance of product/TDS approval prior to start of the work.The pole manufacturer must submit the confirmation regarding 10 years or more design life of the pole.Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with Solar light on that foundation. The work shall be excuted as per the direction of EIC. Installation of Octagonal Poles and fixing of 1 no AIO solar light in the bracket by using suitable machinery adopting all the safety precaurtions as per the direction of EIC. Make : - Utkarsh/RR Ispat/Vakrangee)
250Supply of 60 W AIO Solar street lights having 150Wp or more highly efficient Monocrystalline PV module & 12.8 V 66 Ah or more ) Lithium Ferrophosphate (LiFePo4) Battery (BIS approved) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), MPPT charge controller having > 92% efficiency & PIR Sensor. The initial lumen output of AIO street light shall be >9600 lumen or more in CCT 6000K (+/-500K) (Lumen efficacy of 160 lm/w ) as per LM 79 report of NABL lab The LED chip will be of OSRAM/NISCHIA/CREE/SEOUL Semiconductor only and should be with lenses for effective lighting distribution. The complete system & BMS should be designed to provide 2 days (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 66 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. . Warranty on the AIO street lights must be 5 years .The solar lighting company must submit the warranty certificate in the department by mentioning 5 years warranty on complete lighting system against manufacturing defects. Solar lighting company has to repair/replace the lighting system if required against the manufacturing defect till compleiton of warranty period. The Agency/Contractor has to maintain the lighting system till the completion of warranty period by considering the periodical maintenance like panel cleaning in regular interval and rectifying the defect by engaging labour/machinery to make the lighting system operative till warranty period. The agency/contractor must submit declaration for maintaining the system till warranty period .The following test reports/certifications must be submitted for the technical acceptance of the products .1. LM 79 REPORT NABL lab ) , 2. IK 08 (Report of NABL lab ), 3. IP 66 Report of NABL lab (The necessary test reports of NABL lab against the above must be submitted for any wattage of Solar Street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of Solar Lighting Company (Make:Crompton/Havells/Panasonic/Philips/Wipro) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57664468
AUTHORITY Government Departments
TENDER VALUE 2.44 Crore
LAST DATE 06-10-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of 8 Nos. Residential Staff Quarter E Type At Tahasil Office,Building Bhatli In The District Of Bargarh For The Year 2025-26.
Basic Detail
Tender No ONLINE-RWCSBP-22/2026-27
Bidding Type Tender
Location
City Bargarh
State Odisha
Key Dates
Publish Date 23 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 2.44 Crore
Tender Fee 10000
EMD 2.44 Lakhs
Exemption Available
Document List
9efa192b-243a-48a2-9f85-0236046c643e.html
BOQ_610594.xls
Tendernotice_1 (20).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

9efa192b-243a-48a2-9f85-0236046c643e.html

xls

BOQ_610594.xls

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders