Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57664436

Tender For Repair Maintenance To Fire Alarm Cum Detection System Including Connected Fitting Fixtures At Map Ph-I, Ph-Ii And Ch (Ec) Under Ge Alipore Kolkata

Issued by Statutory Bodies & Commissions/Committees · Kolkata, West Bengal
Tender Value
45 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
19 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance To Fire Alarm Cum Detection System Including Connected Fitting Fixtures At Map Ph-I, Ph-Ii And Ch (Ec) Under Ge Alipore Kolkata

BOQ

Name of Work:- REPAIR MAINTENANCE TO FIRE ALARM CUM DETECTION SYSTEM INCLUDING CONNECTED FITTING FIXTURES AT MAP PH-I, PH-II AND CH (EC) UNDER GE ALIPORE KOLKATA
Sl. No. Item Description
1Supply, fixing, testing & commisioning Sprinkler comprises of 15mm dia conventional pattern, 68 degree centigrade, quatzoid bulb type pendent sprinklers. The installation shall be complete as per the drawings and requirement of local fire service & complete all as specified and directed. MAKE : Spray safex / HD or equivalent make as approved by GE
2S&F Sprinkler rossette complete all as specified and directed.
3S&F Sprinkler flexible drop 1m complete all as specified and directed.
4Supplying, fixing, testing and commissioning of automatic fire Alarm detectors including end of line relay bases whereever required as per specifications including making connections with wires to complete the system complete all as specified and directed o the following types:- MAKE : System Sensor / Apollo / Edward or equivalent make as approved by GE
5Optical /Photoelectric type smoke detectors as per IS : 11360 - 1985 of photo-optic sensing chamber, 12/24 volt DC, twin visual alarm indicator \\"Blink\\" in stand by and \\"Steady\\" in alarm (LED's) with base as required.
6Fixed cum rate of rise temprature type heat detectors as per IS : 2175 - 1988, 57 to 60oC (135 degree F) (fixed) and 15 degree F per minute rate of rise twin visual alarm indicators (LED's) \\"Blink\\" in stand by and \\"Steady\\" in alarm with base as required.
7Projected beam smoke detector with protection range upto 100 meter operating temperature of -22 degree F to +131 degree F, caliberated test filter, alarm indicator (local red LED), trouble indicator (local amber LED), normal indicator (local flashing green LED), alignment LED etc.
8Supplying, fixing, testing and commissioning of manual call point, break glass type housed in 16 SWG sheet steel housing in surface/recess including making connections with wires complete as per specifications. The manual call point should have an indicator, which should \\"blink\\" in stand by condition complete all as specified and directed. Make:MPA/ASC or equivalent make as approved by GE
9Supplying, fixing, testing and commissioning of electronic hooters (hooters shall also be able to work as public address system sounders) housed in 16 SWG sheet steel housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete all as specified and directed.
10Supplying, fixing, testing and commissioning of response indicators pulsating type suitable for operation on 12/24 volts DC, housed in 16 SWG sheet steel housing suitable for surface/recess mounting including making connections with wires; the response indicator should have an indicator, which should \\"blink\\" in stand by condition complete all as specified and directed.
11Supplying, fixing, testing and commissioning of ISI marked 2 core, 1.5 sqmm PVC insulated Armoured stranded copper conductor cable conforming to IS : 1554 specifications on existing cable tray / rack or fixing on wall/ ceiling with iron clamps or inside existing pipe including end termination, glands, lugs & clamps etc. complete all as specified and directed.
12S&F concealed or open 20 mm external dia. rigid non metallic PVC conduit with and including all tees, bends, elbows, reducers, bell mouth tube ends, junctions and terminal boxes and fixing accessories such as couplers, lock nuts, saddles, pipe hook, etc for fire alarm wires complete all as specified and directed. Note: Cutting chases shall be deemed to be included in unit rate quoted.
13S&F self illuminated \\"EXIT\\" signs made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed to the walls as required complete all as specified and directed.
14S&F in position ISI marked nominal bore cast iron sluice valves, flanged 150 mm of class 1.6 PN, IS - 14846, suitable for pressure 15 KG/cm 2 including transporting to work site, nuts, bolts, gaskets, flanges & washers etc. including testing complete all as specified and directed.
15S&F in position ISI marked 150 mm nominal bore cast iron, double flanged, Non return valve as per IS : 5312, part- I, suitable for pressure 15 KG/cm 2 , including transportation to work site, nuts, bolts, gaskets and washers etc. including testing complete all as specified and directed.
16Supply, installation and testing of cylindrical type flanged air vessel tank, 450 mm dia, 1.0 m long and made out of 6 mm thick MS plain black sheet, including necessary welding or riveting as directed, common for all pump sets including flanged connection, suitable supporting legs etc. The air cushion tank shall be provided with stop cock, safety valve, pressure gauge, drain valve, provisions for pressure switches, tested to min 15 KG/cm 2 with & including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
17Supply, installation 4 way 63 mm instantaneous inlet for fire brigade connection and making connection with 150 NB fire fighting wet riser pipe or under ground water tank and fixing inlets with caps and chains in a 4 mm thick glass fronted box of 16 SWG MS sheet, fixing it on the ground level on concrete base or on MS Angle Iron frame, with & including painting with two coats fire red paint over a coat of primer including testing complete all as specified and directed. MAKE: Firex / Safex / Minimax / Newage or equivalent make as approved by GE.
18M&L for Construction of brick masonry valve pit of size 120 x 120 x 120cm (internal dimension) of sub class 'B' brick built in cement mortar (1:4) on 200 mm thick PCC (1:4:8) type D2 using 40 mm stone graded crushed stone aggregate as in bedding and coping, 15 mm thick cement platering in cm (1:4) internally and externally upto 15 cm below ground level and providing valve pit cover with 3mm thick MS sheet welded with (40 x 40 x 6) mm angle iron frame fixed on top surface of pit wall on edge of the cover and hinged in one side and providing locking arrangement including painting of the steel surfaces with two coas of synthetic enamel over one coat of red oxide primer including excavation in any type of soli complete all as specified and directed.
19Supplying and laying 25 Sqmm 4 core Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin type cable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands (on surface, the cable run shall on MS cable trey or fixed on MS clamps etc.of suitable size) complete all as specified and directed. NOTE: In case cable is laid in trenches excvation and earthwork, sand cushioning and brick protection shall be measured and paid separately.
20M&L for flame proof point wiring with copper conductor from ground floor to top floor for MCP/Hooter/Control Pannel Board (Control panel Board to Each MCP located at Each floor and hooter) including appropriate size of PVC casing capping/PVC Conduit with all accessoriese for surface/concealed wiring as per existing including 2x1.5 sq. mm + earth wire 1.5 sqmm PVC insulated copper cable 1100 Volts grade complete all as specified and directed. Note: PVC conduit will measured and paid separately
21S&F Bends ductile Iron (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of size up to 300mm dia complete all as specified and directed.
22S&F butterfly valve, ISI marked conforming to IS 13095, 80 dia bore complete all as specified and directed.
23S&F butterfly valve, ISI marked conforming to IS 13095, 100 dia bore complete all as specified and directed.
24S&F butterfly valve, ISI marked conforming to IS 13095, 150 dia bore complete all as specified and directed.
25M&L for mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size with & including applying one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint complete all as specified and directed.
26S&F nozzle made of SS 63 mm inlet and 16 to 20 mm dia shut off outlet dia complete all as specified and directed.
27Cutting existing 150mm MS pipe line and fixing of any type of fitting for connecting new pipe line complete all as specified and directed
28Dismantling, servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed .
29M&L for repair / replacement of worn out Gland Packing of pump set / sluice valves / hydrants any make / metal / size including washers of any shape / size to avoid water leakage as indicated including taking out old one complete all as specified and directed.
30Supplying, fixing, testing and commissioning of local fire alarm control and indicating panel with mimic panel with indicating lights etc for proper working of the system and as per specifications. The control wires between the local control panel and the main control panel should be monitored and give a fault indication at the Main Panel in the event of a fault complete all as specified and directed. MAKE : Minimax / Mather+Platt / Safeway or equivalent make as approved by GE.
31Control Panel 14 Zone
32Control Panel 10 Zone
33Control Panel 8 Zone
34Supply, installation, testing, commissioning and testing of loop card for Networkable Analogue Addressable Fire Alam Control Panel compatible with existing system approved by EN 54 complete all as specified and directed
35Supply, installation, testing, commissioning and testing of Networkable Analogue Addressable Fire Alam Control Panel. The Panel Shall be compliant with EN54-4 and approved by LPCB. The Fire Alarm control Panel should have 4 loops & shall have expandable capacity to 8 loops. The panel must have full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The panel must also have the capability to take addressable intelligent wire and wireless devices on same loop. Each loop shall have a capacity of 127 analogue addressable devices and 127 base sounders/Base sounder beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, filterable and printable. The panel shall have three access levels. Panel shall support filterable and printable. The panel shall have three access levels, panel shall support upto 500 cause & effects entries, with upto 20,000 inputs controlling & 20,000 controlling outputs across the network. The panel shall have capability for peer to peer networking through Rs 485 network card. The panel must have 4 inbult programmable sounder circuits, each circuits rated at 2.5A.
36BoQ Serial Item No.29.00 Contd/- : The panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The panel shall have up to sub-addressable 512 programmable inputs/outputs via optional Rs 485 COMMS serially connected expansion cards. The panel shall have 240V AC power supply alongwith automatic battery charger. The panel shall be fully expandable via common plug in loop driver boards, The user shall have a choice of using the panel with 5.25 Amp to 10.25 Amp power supply unit which is inbult in the FACP and should be approved to EN54-4. The panel shall have configurable via USB port to PC or memory stick. The panel shall have dedicated Rs 232 serial port for optional printer complete all as specified and directed approved by EN 54 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57664436
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance To Fire Alarm Cum Detection System Including Connected Fitting Fixtures At Map Ph-I, Ph-Ii And Ch (Ec) Under Ge Alipore Kolkata
Basic Detail
Tender No GE/ALP (8735) KOLKATA OF 2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 23 Sep 2026
Submission Date 14 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
48596ffe-a6b9-4793-a8e8-565bdac6ca74.html
BOQ_886570.xls
sch.pdf
tenderdoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

48596ffe-a6b9-4793-a8e8-565bdac6ca74.html

xls

BOQ_886570.xls

pdf

sch.pdf

pdf

tenderdoc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders