Bids Are invited for Internal Electrification Of Hop Quarter At Tuirial Neepco Mizoram
Tender Overview
Project Description
Bids Are invited for Hffr 1100 Voltage 1.5 Sq. Mm Copper Wire For Very Short Light Point With Frls Pvc Conduit Pipe - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is 694-1990 And Halogen Fire Retardant (Hffr) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5 Sq Mm Running Inside Frls-Pvc Coduit Pipe (Heavy Duty) 20Mm Diameter Fixed, Recess Inside The Wall,Ceiling,Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Switch To The Light Point,Fan Point,Exaust Fan Point Etc As Required (I)Light Point, Very Short Point (Moduler). The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Hffr 1100 Voltage 1.5 Sq. Mm Copper Wire For Short Light Point With Frls Pvc Conduit Pipe - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is-694 (1990) And Halogen Fire Retardant (Hffr) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5 Sq Mm Running Inside Frls-Pvc Coduit Pipe (Heavy Duty) 20Mm Diameter Fixed, Recess Inside The Wall, Ceiling, Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Switch To The Light Point,Fan Point,Exaust Fan Point Etc As Required(I) Light Point, Short Point (Moduler). The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Hffr 1100 Voltage 1.5 Sq. Mm Copper Wire For Medium Light Point With Frls Pvc Conduit Pipe - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is-694 (1990) And Halogen Fire Retardant (Hffr) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5 Sq Mm Running Inside Frls-Pvc Coduit Pipe (Heavy Duty) 20Mm Diameter Fixed, Recess Inside The Wall, Ceiling, Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Switch To The Light Point,Fan Point,Exaust Fan Point Etc As Required (I) Light Point. Medium Point (Moduler). The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Hffr 1100 Voltage 1.5 Sq. Mm Copper Wire For Long Light Point With Frls Pvc Conduit Pipe - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is-694 (1990) And Halogen Fire Retardant (Hffr) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5 Sq Mm Running Inside Frls-Pvc Coduit Pipe (Heavy Duty) 20Mm Diameter Fixed, Recess Inside The Wall, Ceiling, Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Switch To The Light Point,Fan Point, Exaust Fan Point Etc As Required (I) Light Point. Long Point (Moduler). The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Calling Bell Point Long Point - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Conductor/Wires As Per Is 694 (1990) And Halogen Free Fire Retardant (Hffr) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5 Sqmm Running Inside Frls Pvc Concuit Pipe (Heavy Duty) 20Mm Dia Fixed, Recess Inside The Wall/ Floor As Per Convenience Including Junction Box Having Required Numbers Of Ways From Control Bell Push Switch To The Light Point Etc As Required (I) Calling Bell Point. Long Point. The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Hffr 1100 Voltage 2.5 Sq.Mm Copper Wire For Very Short Light Plug Point With Frls Pvc Conduit Pipe - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is-694 (1990) And Halogent Free Fire Retardant(Hffr) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 2.5 Sqmm Running Inside Frls Pvc Coduit Pipe (Heavy Duty) 20Mm Dia Fixed, Recess Inside The Wall, Ceiling, Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Db To The Light Plug,Socket 5-6A Point Etc As Required (I)Light Plug Point. Very Short Point (Moduler). The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Zhls 1100 Voltage 4.0 Sq.Mm Copper Wire For Medium Power Plug Point With Frls Pvc Conduit Pipe - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is-694(1990) And Life Shield- Zero Halogen Low Smoke (Zhls) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 4 Sqmm Running Inside Frls-Pvc Conduit Pipe (Heavy Duty) 20Mm Dia Fixed, Recess Inside The Wall, Ceiling, Floor As Per Convenience Including Junction Box Having Required Numbers Of Ways From Db To The Power Plug,Socket 15,16A Point Etc. As Required (I) Power Plug Point. 15 Or 16A Medium Point (Modular). The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Halogen Free Fire Retardant Copper Conductor Including Earth Wire - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Conductor Wires As Per Is-694 (1990) And Halogent Free Fire Retardant (Hffr) Or Fr 1100 Voltage Graded Copper Flexible Wire Stranded Copper Of Defferent Size As Mention Below Running Inside Frls-Pvc Conduit Pipe(Heavy Duty) Of Different Dia Fixed, Recess Inside The Wall, Ceilling, Floor As Per Convenience Including Junction Box Having Required Numbers Of Ways From Main To Sub-Main Or Db, Sub-Main Or Db To Sdb Or Switch Board Or Sdb To Switch Board As Required.(I) 2X4 Sqmm Copper Conductor Cable Plus 1X4.0 Sqmm Earth Wire. The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , 2 X 6 Sqmm And 1X6 Sqmm Halogen Free Fire Retardant Copper Conductor Including Earth Wire - Wiring In Looping System With Pvc Wire Sheathed Standard Copper Wires As Per Is-694 (1990) And Halogent Free Fire Retardant (Hffr)Or Fr 1100 Voltage Graded Copper Flexible Wire Stranded Copper Of Defferent Size As Mention Below Running Inside Frls-Pvc Conduit Pipe(Heavy Duty) Of Different Dia Fixed, Recess Inside The Wall,Ceilling,Floor As Per Convenience Including Junction Box Having Required Numbers Of Ways From Main To Sub-Main Or Db, Sub-Main Or Db To Sdb Or Switch Board Or Sdb To Switch Board As Required. (I) 2X6 Sqmm Copper Conductor Cable + 1X6 Sqmm Earth Wire. The Price Quoted Shall Be Inclusive Of All Expenses To Execute The Item. , Phenolic Laminated Switch Board - Supplying And Fixing Of Ft Metal Box With Phenolic Laminated Or Sunmica Sheet Cover Of The Following Sizes On Surface Recess Including Necessary Switches, Plug Socket And Fan Regulators Etc. With Necessary Painting If Necessary (I) 8 Inch X 12 Inch Switch Board (Ordinary) 18S , 8 Way Mcb Db Tp And N - Supplying, Fitting And Fixing Of 4-Ways, Loadline Mcb, Db,Tp And N, Vertical Suitable For G-Frame Mccb(Without Mccb) Design For Multiphase Out Going, Single Door In Sheet Steel Phosphatised Powder Painted Mcb, Dbs With Bus Bar, Neutral Link, Earth Bar And Din Rail Conforms To Is-13032, Is-8623, Bs-5486, 240Volts 50Hz On Surface Recess Including Inter Connection, Painting Etc. As Required. (I) 8-Way Mcb, Db, Tp And N Loadline Sd Vertical Suitable For G-Frame Mccb (Without Mccb) , Earthing With G.I Earth Pipe - Earthing With G.I Earth Pipe 3.5 Mtr Long And 25Mm Dial For Copper Wiring Including Accessories And Providing Masonery Enclosure With Cover Plate Having Locking Arrangement And Water Pipe, Etc (But Without Charcoal Or Coke And Salt) , Supply Of Salt And Charcoal - Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required , 6 To 32 Dp Mcb B Series - Supply And Fixing Of All Types And Rating Mcbs, Rccbs, Elcbs Etc, 240/415 Volts 50Hz Ac Supply In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc In Completed. (I) 6 To 32 Dp Mcb B Series , Luminaire With Electronic Ballast - Supply And Fixing Of Ftl Deco 1 X 18W Dreamlite Electronic/Mirolta Slim Compact Energy Efficient Luminaire With Coloured End Caps And Electronic Ballast Suitable (Havels/Philips/Cromton/Bajaj) , Installation Testing Commissioning Of Pre Wired Flourescent Light - Installation, Testing And Commissioning Of Pre-Wired Flourescent Light Fitting Of All Type, With All Accessories And Tube Etc. Direcly On Ceilling/Wall. Including Connection With 1.5 Sqmm Copper Conductor Single Core Cable Etc As Required , Supply Of Angle Holder - Supply, Fitting And Fixing Of Angle Holder Including Connection Etc As Required , Supply, Insttallation Of Calling Bell - Supply, Fitting And Fixing Calling Bell-Buzzer Suitable For Ac-Dc Single Phase 230Volts Compleated As Required , Supply Of 5 Star Rated Ceiling Fan - Celling Fan 5 Star Rated E5 (White/Brown/Ivory 1200Mm Sweeps (Havells/Usha/Polar/Gromton/Bajaj) , Installation Testing Commissioning Of Ceiling Fan - Installation, Testing And Commissioning Of Celling Fan And Regulator, Including Wiring The Down Rod Of Standard Length (Upto 30 Cm) With 2 X 1.5 Sqmm Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supply Of Bulk Head Fitting - Supply, Fitting And Fixing Bulk Head Fitting 1X8cfl/100W Gsl Rugby Bulk Head In Die Cast Alluminium Housing And Frosted Glass Completed As Required. , Supply Of Exhaust Fan - Exhaust Fan 300Mm Sweeps Isi Marked (Usha/Havell/Polar/Gromton/Bajaj) , Supply Of Down Lighter - Supply And Fixing Of Down Lighter 1X60-100 W Gsl/Cfl Dn622 (Philips/Havell/Gromton/Bajaj/Syka) , Supply Of 8 Way Mcb Db - Supply And Fixing Of 8 Way(2+8) Mcb Db Sp And N Consumer Unit D/S (Phlip/Havel/Gromton)
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | HFFR 1100 VOLTAGE 1.5 Sq. mm COPPER WIRE FOR VERY SHORT LIGHT POINT WITH FRLS PVC CONDUIT PIPE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS 694-1990 and Halogen fire retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper 1.5 Sq mm running inside FRLS-PVC coduit pipe (Heavy duty) 20mm diameter fixed, recess inside the wall,ceiling,floor as per convenience including junction box having required number of ways from control switch to the light point,Fan point,exaust Fan point etc as required (i)Light Point, Very Short point (moduler). The price quoted shall be inclusive of all expenses to execute the item. |
| 2 | HFFR 1100 VOLTAGE 1.5 Sq. mm COPPER WIRE FOR SHORT LIGHT POINT WITH FRLS PVC CONDUIT PIPE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS-694 (1990) and Halogen fire retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper 1.5 Sq mm running inside FRLS-PVC coduit pipe (Heavy duty) 20mm diameter fixed, recess inside the wall, ceiling, floor as per convenience including junction box having required number of ways from control switch to the light point,Fan point,exaust Fan point etc as required(i) Light Point, Short point (moduler). The price quoted shall be inclusive of all expenses to execute the item. |
| 3 | HFFR 1100 VOLTAGE 1.5 Sq. mm COPPER WIRE FOR MEDIUM LIGHT POINT WITH FRLS PVC CONDUIT PIPE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS-694 (1990) and Halogen fire retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper 1.5 Sq mm running inside FRLS-PVC coduit pipe (Heavy duty) 20mm diameter fixed, recess inside the wall, ceiling, floor as per convenience including junction box having required number of ways from control switch to the light point,Fan point,exaust Fan point etc as required (i) Light Point. Medium point (moduler). The price quoted shall be inclusive of all expenses to execute the item. |
| 4 | HFFR 1100 VOLTAGE 1.5 Sq. mm COPPER WIRE FOR LONG LIGHT POINT WITH FRLS PVC CONDUIT PIPE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS-694 (1990) and Halogen fire retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper 1.5 Sq mm running inside FRLS-PVC coduit pipe (Heavy duty) 20mm diameter fixed, recess inside the wall, ceiling, floor as per convenience including junction box having required number of ways from control switch to the light point,Fan point, exaust Fan point etc as required (i) Light Point. Long point (moduler). The price quoted shall be inclusive of all expenses to execute the item. |
| 5 | CALLING BELL POINT LONG POINT | Wiring in looping system with PVC wire sheathed standard copper conductor/wires as per IS 694 (1990) and Halogen Free Fire Retardant (HFFR) 1100 voltage graded copper flexible wire stranded copper 1.5 sqmm running inside FRLS PVC concuit pipe (Heavy Duty) 20mm dia fixed, recess inside the wall/ floor as per convenience including junction box having required numbers of ways from control bell push switch to the light point etc as required (i) Calling Bell Point. Long point. The price quoted shall be inclusive of all expenses to execute the item. |
| 6 | HFFR 1100 VOLTAGE 2.5 Sq.mm COPPER WIRE FOR VERY SHORT LIGHT PLUG POINT WITH FRLS PVC CONDUIT PIPE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS-694 (1990) and Halogent Free Fire Retardant(HFFR) 1100 voltage graded copper flexible wire stranded copper 2.5 Sqmm running inside FRLS PVC coduit pipe (Heavy duty) 20mm dia fixed, recess inside the wall, ceiling, floor as per convenience including junction box having required number of ways from DB to the light plug,Socket 5-6A point etc as required (i)Light plug Point. Very Short point (moduler). The price quoted shall be inclusive of all expenses to execute the item. |
| 7 | ZHLS 1100 VOLTAGE 4.0 Sq.mm COPPER WIRE FOR MEDIUM POWER PLUG POINT WITH FRLS PVC CONDUIT PIPE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS-694(1990) and Life shield- Zero Halogen low smoke (ZHLS) 1100 voltage graded copper flexible wire stranded copper 4 Sqmm running inside FRLS-PVC conduit pipe (Heavy Duty) 20mm dia fixed, recess inside the wall, ceiling, floor as per convenience including junction box having required numbers of ways from DB to the power plug,socket 15,16A point etc. as required (i) Power Plug Point. 15 or 16A Medium Point (Modular). The price quoted shall be inclusive of all expenses to execute the item. |
| 8 | HALOGEN FREE FIRE RETARDANT COPPER CONDUCTOR INCLUDING EARTH WIRE | Wiring in looping system with PVC wire sheathed standard copper conductor wires as per IS-694 (1990) and Halogent Free Fire Retardant (HFFR) or FR 1100 voltage graded copper flexible wire stranded copper of defferent size as mention below running inside FRLS-PVC conduit pipe(Heavy duty) of different dia fixed, recess inside the wall, ceilling, floor as per convenience including junction box having required numbers of ways from main to Sub-Main or DB, Sub-main or DB to SDB or Switch board or SDB to Switch board as required.(i) 2x4 Sqmm copper conductor cable plus 1x4.0 Sqmm earth wire. The price quoted shall be inclusive of all expenses to execute the item. |
| 9 | 2 x 6 Sqmm and 1x6 Sqmm HALOGEN FREE FIRE RETARDANT COPPER CONDUCTOR INCLUDING EARTH WIRE | Wiring in looping system with PVC wire sheathed standard copper wires as per IS-694 (1990) and Halogent Free Fire Retardant (HFFR)or FR 1100 voltage graded copper flexible wire stranded copper of defferent size as mention below running inside FRLS-PVC conduit pipe(Heavy duty) of different dia fixed, recess inside the wall,ceilling,floor as per convenience including junction box having required numbers of ways from main to Sub-Main or DB, Sub-main or DB to SDB or Switch board or SDB to Switch board as required. (i) 2X6 Sqmm copper conductor cable + 1X6 Sqmm earth wire. The price quoted shall be inclusive of all expenses to execute the item. |
| 10 | PHENOLIC LAMINATED SWITCH BOARD | Supplying and fixing of FT metal box with phenolic laminated or Sunmica sheet cover of the following sizes on surface recess including necessary switches, plug socket and fan regulators etc. with necessary painting if necessary (i) 8 inch x 12 inch Switch Board (Ordinary) 18S |
| 11 | 8 WAY MCB DB TP and N | Supplying, fitting and fixing of 4-ways, loadline MCB, DB,TP and N, vertical suitable for G-frame MCCB(without MCCB) design for Multiphase out going, single door in sheet steel Phosphatised Powder painted MCB, DBs with bus bar, Neutral link, earth bar and din rail conforms to IS-13032, IS-8623, BS-5486, 240Volts 50Hz on surface recess including inter connection, painting etc. as required. (i) 8-way MCB, DB, TP and N Loadline SD vertical suitable for G-frame MCCB (without MCCB) |
| 12 | EARTHING WITH G.I EARTH PIPE | Earthing with G.I Earth Pipe 3.5 Mtr long and 25mm dial for copper wiring including accessories and providing masonery enclosure with cover plate having locking arrangement and water pipe, etc (but without charcoal or coke and salt) |
| 13 | Supply of salt and charcoal | Extra for using salt and charcoal for pipe earth electrode as required |
| 14 | 6 to 32 Amp DP MCB B series | Supply and fixing of all types and rating MCBs, RCCBs, ELCBs etc, 240/415 Volts 50Hz AC supply in the existing MCB DB complete with connections, testing and commissioning etc in completed. (I) 6 to 32 Amp DP MCB B series |
| 15 | LUMINAIRE WITH ELECTRONIC BALLAST | Supply and fixing of FTL Deco 1 x 18W DREAMLITE Electronic/mirolta Slim compact energy efficient luminaire with coloured end caps and electronic ballast suitable (Havels/Philips/Cromton/Bajaj) |
| 16 | Installation testing commissioning of PRE WIRED FLOURESCENT LIGHT | Installation, testing and Commissioning of pre-wired Flourescent Light fitting of all type, with all accessories and tube etc. direcly on ceilling/wall. Including connection with 1.5 Sqmm copper conductor single core cable etc as required |
| 17 | Supply of angle holder | Supply, fitting and fixing of angle holder including connection etc as required |
| 18 | Supply, Insttallation of Calling Bell | Supply, fitting and fixing calling Bell-Buzzer suitable for AC-DC single phase 230Volts compleated as required |
| 19 | Supply of 5 star rated ceiling fan | Celling Fan 5 star rated E5 (white/Brown/ivory 1200mm sweeps (Havells/Usha/Polar/Gromton/Bajaj) |
| 20 | Installation testing commissioning of ceiling fan | Installation, testing and Commissioning of celling Fan and regulator, Including wiring the down rod of standard length (upto 30 cm) with 2 x 1.5 sqmm PVC insulated copper conductor single core cable etc as required. |
| 21 | Supply of Bulk Head Fitting | Supply, fitting and fixing Bulk head fitting 1x8CFL/100W GSL Rugby Bulk head in die cast alluminium Housing and Frosted Glass completed as required. |
| 22 | Supply of Exhaust Fan | Exhaust fan 300mm sweeps ISI marked (Usha/Havell/Polar/Gromton/Bajaj) |
| 23 | Supply of Down lighter | Supply and fixing of down lighter 1x60-100 W GSL/CFL DN622 (Philips/Havell/Gromton/Bajaj/SYKA) |
| 24 | Supply of 8 Way MCB DB | Supply and fixing of 8 way(2+8) MCB DB SP and N consumer unit D/S (Phlip/Havel/Gromton) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender