Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57663340

Tender For Construction Of Mini Secretariat /Combined Office Building Tissa At Bhanjraru In Tehsil Churah District Chamba (H.P.).(Sh Providing ,Installation,Testing And Commissioning Of Addressable Fire Alarm And Pa System Therein.)

Issued by Government Departments · Chamba, Himachal Pradesh
Tender Value
27.29 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
0 days left
EMD
54600
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chamba → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Mini Secretariat /Combined Office Building Tissa At Bhanjraru In Tehsil Churah District Chamba (H.P.).(Sh Providing ,Installation,Testing And Commissioning Of Addressable Fire Alarm And Pa System Therein.)

BOQ

Name of Work:- Construction of Mini Secretariat /Combined office building Tissa at Bhanjraru in Tehsil Churah District Chamba (H.P.).(SH Providing ,Installation,Testing and Commissioning of Addressable Fire Alarm and PA System therein.)
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 2 Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8\\" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories, UL-FM/EN54-VDS Listed Certification.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
2Make: Schrack Honeywell (Notifire) / JC/IFC Series
3Supply, Installation, Testing and Commissioning of Active and networkable repeater panel with 4x20 character LCD display complete system function keys for programming and control like system reset, alarm acknowledgement, alarm silence, trouble acknowledgement etc. Shall be UL-FM/EN54-VDS Listed Certification.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
4Make: Schrack Honeywell (Notifire) / JC/IFC Series
5Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL-FM/EN54-VDS Listed Certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) . The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
6Make: Schrack Honeywell (Notifire) / JC/IFC Series
7Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL-FM/EN54-VDS Listed Certification.. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) . The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
8Make: Schrack Honeywell (Notifire) / JC/IFC Series
9Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL-FM/EN54-VDS Listed Certification.
10Make: Schrack Honeywell (Notifire) / JC/IFC Series
11SITC of Loop Powered Sounder cum Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should have IP40 or better protection rating be programmed from the panel. Shall be UL-FM/EN54-VDS Listed Certification.
12Make: Schrack Honeywell (Notifire) / JC/IFC Series
13Supply, Installation, Testing and Commissioning of Addressable Phone Control Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL-FM/EN54-VDS Listed Certification.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
14Make: Schrack Honeywell (Notifire) / JC/IFC Series
15Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doorsetc, Shall be UL-FM/EN54-VDS Listed Certification.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
16Make: Schrack Honeywell (Notifire) / JC/IFC Series
17Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
18Make PES/Giolite/OMEX
19Supply, Installation, Testing and Commissioning of 3/1.5 W Horn type loud speakers with following features:- Built-in 100 / 70 V LMT compliance with IEC60268 - Part 5, Power tapping 15 / 7.5 / 3.75 W, Sound pressure level at 3/1.5 W / 1 W (1 kHz, 1 m) 115 / 103 dB (SPL)complete with necessary mounting hardware & accesories. Certified to UL/ EN standards as required complete in all respects.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
20Make: Schrack Honeywell (Notifire) / JC/IFC Series
21Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power -12W ,Rated power (PHC) - 9W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 .The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
22Make: Schrack Honeywell (Notifire) / JC/IFC Series
23Supply, Installation, Testing and comissioning of controller unit 6-zone system pre-amplifier 240 amplifier Inbuilt Bluetooth and USB pen drive. Two input channels for call stations , Universal input for microphone/line, with speech optimized tone control , Three inputs for BGM selection and music optimized tone control , Front panel zone selection for BGM and call station zone selection for calls, S/N (flat at max volume) >63 dB (mic); >70 dB (line), S/N (flat at min volme/muted) >75 dB, CMRR >40 dB (50 Hz – 20 kHz),Line input 3 x, Master output 1 x, Frequency response 50 Hz to 20 kHz (+1 / -3 dB) complete in all respect.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
24Make: Schrack Honeywell (Notifire) / JC/IFC Series
25Supply, Installation, Testing and comissioning of Stylish 6-zone call station, Six zone selection keys, allcall key and momentary PTT-key for calls Selectable gain, speech filter and limiter for improved intelligibility LED indications for zone selection, fault and emergency state Voltage range 18 – 24V Nominal sensitivity 85 dB SPL (gain preset 0dB) Gain preset +6 / 0 / -15 dB Equivalent input noise level 25 dBSPLA Frequency response 100Hz – 16kHz complete in all respect.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
26Make: Schrack Honeywell (Notifire) / JC/IFC Series
27Supply, Installation,testing & Commissioning of digital autio amplifire 75 watt,25 V rms opreating 240V AC supply complete as required.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
28Make: Schrack Honeywell (Notifire) / JC/IFC Series
29Supply, Installation, Testing and comissioning of 2 core multistrand 1.5 sq mm annealed copper conductor Fire alarm & speaker cable in existing pipe/ channel I/C connection etc.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
30Makes:- Finolex/Polycab/Havells/ KEI
31Supply, Installation, Testing & commissioning of PVC Conduit Pipe, 25mm medium duty, ISI Mark with complete accessories as required complete in all respects and to the best satisafaction of Engineer-in-Charge.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
32Makes:- Diplast/Polyplast
33Supply, Installation, Testing and comissioning of 19U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect. The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
34Makes:- Valrack /Netrack/ Comrack
35Supply, Installation, Testing and comissioning of 2KVA UPS Cum inverter, including batteries and 2 hour Backup as required complete in all respects and to the best satisafaction of Engineer-in-Charge.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST.
36Makes:- LIBERT EINOVA/APC /Luminous
37Testing for system operation shall be conducted in presence of Engineer in charge & test certificate shall be furnished for the same. Testing shall be conducted using a test fire at normal floor level. The number of locations for such test shall be 1% of the total number of detectors in an installation subject to a minimum of two and maximum of five. The system operation for fault conditions shall be conducted by introducing faults such as open circuit, short circuit, removal of detector, open/short circuit in a sounder circuit etc. NOC/Approval from concremed Fire Officer is to be obtained as per H.P. Fire regulation & byelawas.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57663340
AUTHORITY Government Departments
TENDER VALUE 27.29 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Mini Secretariat /Combined Office Building Tissa At Bhanjraru In Tehsil Churah District Chamba (H.P.).(Sh Providing ,Installation,Testing And Commissioning Of Addressable Fire Alarm And Pa System Therein.)
Basic Detail
Tender No Electrical Division HPPWD Palampur
Bidding Type Tender
Location
City Chamba
State Himachal Pradesh
Key Dates
Publish Date 23 Sep 2026
Submission Date 29 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 27.29 Lakhs
Tender Fee 2000
EMD 54600
Exemption Not Available
Document List
2073fa5e-40de-4878-bfde-91bfd465efbc.html
BOQ_214243.xls
DECLARATION.pdf
FireChamba.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2073fa5e-40de-4878-bfde-91bfd465efbc.html

xls

BOQ_214243.xls

pdf

DECLARATION.pdf

pdf

FireChamba.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders