Tender For Internal Electrification And Other Allied Work At Vishwakarma Park Bps
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Sep 2026
0 days left
EMD
15600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal Electrification And Other Allied Work At Vishwakarma Park Bps
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/fan point/exhaust fan point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M S. box & earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as reqd. Group – C.1.8.3 |
| 2 | Wiring for circuit / sub main wiring along with earth wire with the following. Sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2 X 2.5 Sq. mm. + 1 X 2.5 Sq. mm. earth wire.1.14.2 |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.1.12 |
| 4 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel MCB distribution board, 415 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator).4 way (4 + 12) Double Door.2.4.1 |
| 5 | Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole. 2.10.1 |
| 6 | Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole & neutral. 2.10.2 |
| 7 | Supplying and fixing two module steeped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.1.25 |
| 8 | Supply /fixing of following module type switch /socket on the existing switch box / cover including connection etc. as required 5/6 amp switch.1.23.1 |
| 9 | Supply /fixing of following module type switch /socket on the existing switch box / cover including connection etc. as required 15/16 amp switch.1.23.3 |
| 10 | Supply /fixing of following module type switch /socket on the existing switch box / cover including connection etc. as required 3 pins5/6-amp socket.1.23.4 |
| 11 | Supply /fixing of following module type switch /socket on the existing switch box / cover including connection etc. as required 6 pins15/16-amp socket.1.23.5 |
| 12 | Supplying and fixing 3 pins, 5-amp ceiling rose on the existing junction box/ wooden block including connection etc. as required1.33 |
| 13 | Supply of LED type luminaries with electronic ballast of capacity 20 W, 1×22 LED type. Make - Havells/Crompton/ Polycab |
| 14 | Supply of LED type luminaries with electronic ballast of capacity 70 watt street light type with wall mounted pipe and nut bolts as required at site Make - Havells/Crompton |
| 15 | Supply of 1200 mm. Sweep Ceiling Fans. Make: -(Orient / Havells / Crompton ). |
| 16 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. As per DSR E&M(2022) Item 1.44 |
| 17 | Supply of 450 mm. Exhaust Fans. Make: -(Orient / Havells / Crompton ). |
| 18 | Installation of exhaust fan/wall mounted air circulator in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep As per DSR E&M Item 1.50.1 |
| 19 | Supply of 2 X 10 Sq. mm. Aluminum Conductor Power Armoured Cable. polycab/ Grandlay/ National. |
| 20 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.1.41 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer