Housing Urban and Rular Development Government Departments Closing in 3 days TDR #57663232

Tender For Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Supplying, Installation, Testing & Commissioning Of Decorative Poles With All Accessories At Chirag Delhi Flyover Under M-South Ele

Issued by Government Departments · Delhi, Delhi
Tender Value
32.50 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
3 days left
EMD
65007
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Supplying, Installation, Testing & Commissioning Of Decorative Poles With All Accessories At Chirag Delhi Flyover Under M-South Electrical Division)

BOQ

Name of Work:- Maintenance of Street Lights, High Masts on Delhi PWD Roads under PWD M-South Division during 2026-27 (SH : Supplying, installation, Testing & Commissioning of Decorative Poles with all accessories at Chirag Delhi Flyover Under M-South Electrical Division)
Sl. No. Item Description
1Supplying & erection of flange mounted hot dip galvanized octagonal poles of 7 mtrs. height made from 3 mm thick HR Steel plate having bottom dia of 130 mm & top dia of 70 mm complete with window sleeve type cover arrangement at a height of 0.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 225 mm x 225 mm x 12 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination.
2Supply & fixing 6 mm thick laminated mounted sheet inside the window i/c providing mounting arrangement etc complete as reqd.
3Supply and fixing 63 amps. terminal block suitable for 16 sq. mm conductor- 4 Nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length on the existing laminated sheet.
4Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 2 Nos, earth stud -1 Nos, welded at suitable height one nos washers, springs washers & nuts.
5Provision on 4.5 mtrs. height for fixing of additional bracket
6Cable supports clamps sutiable for 4 x 16 sq. mm cable.
7Providing and laying in position (1:2:4) reinforced cement Concrete foundation of size 400 mm (L) X 400mm wide and 1200mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement ring of cold twisted bars of 12 mm dia 1350 mm long (approx) 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia -1800mm (approx) 8 nos. (with 150 mm spacing) as requried with positioning of foundation bolts and providing 63 mm dia (O.D.) DWC, HDPE pipe of 0.3 mtrs. length for cable entry & exit as reqd.
8Supplying and Fixing 4 Nos. 20 mm dia. X 600mm long GI foundation bolt(EN8 grade) with nuts,washer including 2 Nos. template of 3 mm thick size 200mmX200mm with 4 Nos. 24mm dia holes to match with PCD of Pole base plate as reqd.
9Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
10120 watt
11Fabrication, supplying & fixing of Designer single/double/tripple over hang PU Painted bracket made out of Suitable dia etc. complete as required.(Design as per approved sample).
12Supplying and Laying of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following size In HUME/ DWC Pipe/ Metal Pipe/ RCC Pipe etc. as required.
134 X 16 Sq. mm.
14Supplying & laying of one number 4 x 25 sq.mm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in the follwing manner etc as complete reqd..a. On wall surface as required.
15Supplying & laying of one number 3.50 x 50 sq.mm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in the follwing manner etc as complete reqd..a. On wall surface as required.
16Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
1763 mm dia (OD-63 mm & ID-51 mm nominal)
18Supplying and drawing following size of PVC insulated Aluminium conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.
193 core 2.5 sq.mm Al cable
20Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
21Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
22Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
23Removal of RCC Crash barrier upto 6 mtr length & 1.5mtr high with Hydra from central verge of road to side way and after formation of foundation staking the same way in central verge etc as reqd.
24Fabrication, Installation, Testing and Commissioning of floor mounting double door minimum 300 mm depth with locking arrangement front and rear openable, totally enclosed, compartmentalized, dust, vermin proof and outdoor type Feeder Pillar (IP54) fabricated out of 2mm thick cold rolled carbon annealed sheet steel, (minimum) surface area 1.50 Sq.Mtr, with 300 Amp 4 strip AL. bus bar, cable alley on both sides, powder coated paint of approved shade after 7 tank cleaning process and 1 no 20x3mm GI strips throughout the width of feeder pillar consisting two earth studs on each strip complete with provision for incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing 50mm X 50mm X 6 mm thick (NS) 90 cm long legs out of which 45 cm duly grouted in existing cement concrete 1:2:4 etc complete as reqd.
25(Drawing shall be got approved from Engineer-incharge before fabrication)
26Incomer:-
27200A TP 25KA MCCB WITH SPREADER LINK (Ics=100%Icu) : 01 No.
28Metering:-
29DIGITAL AMMETER (0-200) WITH SELECTOR SWITCH: 01 No.
30DIGITAL VOLT METER (0-500) WITH SELECTOR SWITCH : 01 No.
31INDICATION LED LAMP RYB : 03 No.
322A SP MCB : 03 No.
33200/5A CT CLASS-1: 03 No.
34Out going :-
35100A TP 16KA MCCB WITH SPREADER LINK (Ics=100%Icu) : 03 Nos
36110A TP POWER CONTACTOR 220V: 01 No.
37DIGITAL TIMERS: 01 No.
38Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required: 01 Set
39Fabricating supplying and fixing wiremesh frame work made out of 40x40x6mm thick angle iron having 40x6mm flat strip & wiremesh 6 swg dia m.s wire with 25mmx75mm space in between mesh & top covered for rain protection by 16 SWG MS Sheet and making main door gate having suitable locking arrangement with godown lock (Frame size shall not be more than 60 cm x 90 cm) i/c grouting with cement concrete & primer and spray painting with super synthetic enamel paint of approved colour quality etc as reqd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57663232
AUTHORITY Government Departments
TENDER VALUE 32.50 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Maintenance Of Street Lights, High Masts On Delhi Pwd Roads Under Pwd M-South Division During 2026-27 (Sh : Supplying, Installation, Testing & Commissioning Of Decorative Poles With All Accessories At Chirag Delhi Flyover Under M-South Electrical Division)
Basic Detail
Tender No 73/EE(E)/EMD South Elect. Divn./PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 23 Sep 2026
Submission Date 29 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 32.50 Lakhs
Tender Fee Ref. Documents
EMD 65007
Exemption Not Available
Document List
186b0a12-0c21-4029-9ada-cc7ea1bce20e.html
BOQ_398648.xls
NIT.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

186b0a12-0c21-4029-9ada-cc7ea1bce20e.html

xls

BOQ_398648.xls

pdf

NIT.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders