Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57660587

Tender For Provn Of Dg Set For Mil Dental Centre Fatehgarh Cantt

Issued by Statutory Bodies & Commissions/Committees · Farrukhabad, Uttar Pradesh
Tender Value
11.04 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
11 days left
EMD
22080
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Farrukhabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provn Of Dg Set For Mil Dental Centre Fatehgarh Cantt

BOQ

Name of Work:- PROVN OF DG SET FOR MIL DENTAL CENTRE FATEHGARH CANTT
Sl. No. Item Description
1Supply, installation, testing and commissioning of Diesel Generating Set of capacity not less than 58.5 KVA / 46.8 KW, complete with in-built AMF panel, suitable for prime power operation at NTP conditions, 3-phase, 4-wire, 415 volts, 50 Hz, 1500 RPM, with a power factor of 0.8 lagging, specially designed to comply with the latest applicable MoEF&CC/CPCB emission and noise pollution norms, including acoustic enclosure in CRCA sheet, powder coating to ensure long life in all weather conditions, achieving a maximum noise level of 75 dBA at 1 metre at 75% load under free-field conditions. The acoustic enclosure shall be of a type approved by the National Physical Laboratory (NPL), as applicable, and shall conform to the latest applicable CPCB Stage-IV+ norms, complete all as specified and directed including all the following specifications :-(a) Diesel Engine: Recommended model of manufacturer as per makes mentioned in PS. Electric-start, four-stroke, multi-cylinder, water-cooled diesel engine, developing the required BHP for continuous rating at 1500 RPM, conforming to the latest relevant and prevailing IS/BS/ISO standards and suitable for operation with 10% overload capacity for 1 hour in any 12-hour duration. The engine shall be complete with standard accessories, including flywheel, close-coupling arrangement, radiator, cooling fan, coolant expansion tank, air cleaner, fuel pump, hand priming pump, suitable class governor, lubricating oil filter, residential silencer, starter motor, battery charging alternator, lubricating oil pump, fuel filter, overspeed trip/shut-down device, microprocessor-based engine instrument panel with built-in safety and protection features, suitable for indicating/monitoring parameters such as lubricating oil pressure, coolant temperature, voltage, RPM, running hours, etc., battery charging ammeter and self-starting switch with key, complete all as per applicable standards, manufacturer's recommendations and as specififedDescription of item contd....
2Item No.1 (Contd…)(b) Alternator : Recommended model of manufacturer as per makes mentioned in PS, of continuous rating as specified, brushless type, complete with automatic voltage regulator (AVR), SPDP, suitable for 415 V, 3-phase, 4-wire, 50 Hz supply at 0.8 power factor lagging and 1500 RPM. The alternator shall be self-excited and self-regulated, foot-mounted, suitable for operation under tropical climatic conditions and conforming to the latest relevant and prevailing IS/BS/ISO standards. The alternator shall have voltage regulation within ±1% from no-load to full-load.(c) Base Frame : Sturdy, fabricated mild steel (MS) base frame, suitably designed and adequately reinforced for mounting the complete DG set, including engine and alternator, with suitable anti-vibration mounting arrangements, complete all as specified and directed.(d) Fuel Tank : Daily service fuel tank complete with Diesel Exhaust Fluid (DEF) system, suitably sized for a minimum of 8 hours of operation at the rated load. The fuel tank shall be fabricated from mild steel (MS) sheet of suitable thickness and shall be complete with air vent, fuel inlet and outlet connections, low-level and full-level float valves, fuel level indicator with graduated scale clearly visible from outside and drain arrangement, (e) Battery Set: 1 or 2 Nos. of 12 V batteries, as required by the DG set manufacturer, heavy-duty, duly charged and suitable for reliable engine starting, complete with battery leads, terminals, termination lugs.(f) Miscellaneous: Complete set of anti-vibration mounting (AVM) pads, first filling of engine lubricating oil, fuel piping with necessary fittings, valves and flanges, exhaust piping with suitable flexible bellows, coupling, necessary hardware, fasteners and other accessories and fittings required for installation and satisfactory operation of the DG set.Description of item contd....
3Item No.1 (Contd…)(g) Acoustic Enclosure: Acoustic enclosure fabricated from high-quality CRCA steel sheets of suitable thickness, duly treated against corrosion and finished with suitable protective coating, and internally lined with high-quality sound-absorbing and fire-retardant acoustic material. The enclosure shall be designed and fabricated in accordance with the manufacturer's recommendations and shall comply strictly with the latest applicable CPCB Stage-IV+ emission and noise-control requirements and relevant IS standards.(h) Panel: Standard control panel complete with suitably rated ACB/MCCB/MCB and all necessary protective devices for alternator protection, along with microprocessor-based AMF-ready controller, having digital display and monitoring of all required parameters, including AC/DC voltage, current, kW, kWh, RPM, frequency (Hz), power factor and other essential engine/alternator parameters, complete with necessary indications, alarms, controls, metering, wiring and accessories, as recommended by the manufacturer and complete as specified.((j) Site Testing: Load testing of the DG set at site using an artificial resistive load/water load bank shall be carried out for a total period of 12 hours. The load shall be applied gradually as follows: 25%, 50%, 75% and 100% load for one hour each, followed by 110% load for one hour, thereafter 100% load for four hours, and subsequently the load shall be reduced gradually to 75%, 50% and 25%, maintaining each stage for one hour, complete as specified and directed..(k) Certificates: Original test certificates for the engine, alternator and battery, along with the site load-test certificate/report, shall be submitted. A copy of the valid CPCB-IV+ certification/compliance certificate shall also be submitted along with the DG set.Description of item Contd..
4Item No.1 (Contd…)(l) Drawings: Foundation drawing, general arrangement (GA) drawing of the DG set and control panel drawings, including necessary dimensions, clearances and installation details, shall be submitted to AGE(I) for approval before commencement of installation.(m) Foundation: PCC foundation of suitable size and strength for the DG set, including necessary embedded plates, anchor bolts, supports and other associated works, as recommended by the manufacturer and approved by AGE(I), complete as specified and directed.(n) AMF Panel : As per recommendation of manufacture. (Indoor / Outdoor installation can be specified as per site requirement)1. AMF CONTROL PANEL: Design, supply, fabrication, installation, testing and commissioning of weatherproof AMF control panel, fabricated from minimum 2 mm thick CRCA sheet steel, suitably treated for corrosion protection and finished with powder coating. The panel shall be complete with suitably rated TPN aluminium busbars of adequate current-carrying capacity and short-circuit fault withstand capacity, insulated with heat-shrinkable, colour-coded sleeves and supported on suitable DMC/SMC-type busbar supports. Alternatively, suitable high-conductivity copper busbars may be provided. The panel shall be designed and manufactured in accordance with the applicable standards including all accessories listed below, control wiring etc complete all as specified(i) 100 A, 4-pole, suitably rated MCB/MCCB – 02 Nos.(ii) Microprocessor-based Auto Generator Controller (GCU/AMF controller), suitable for automatic mains failure detection, DG start/stop, mains/DG changeover and associated control functions – 01 No.Description item Contd.... Please Enable Macros to View BoQ information
5Item No.1 (Contd…)(l) Drawings: Foundation drawing, general arrangement (GA) drawing of the DG set and control panel drawings, including necessary dimensions, clearances and installation details, shall be submitted to AGE(I) for approval before commencement of installation.(m) Foundation: PCC foundation of suitable size and strength for the DG set, including necessary embedded plates, anchor bolts, supports and other associated works, as recommended by the manufacturer and approved by AGE(I), complete as specified and directed.(n) AMF Panel : As per recommendation of manufacture. (Indoor / Outdoor installation can be specified as per site requirement)1. AMF CONTROL PANEL: Design, supply, fabrication, installation, testing and commissioning of weatherproof AMF control panel, fabricated from minimum 2 mm thick CRCA sheet steel, suitably treated for corrosion protection and finished with powder coating. The panel shall be complete with suitably rated TPN aluminium busbars of adequate current-carrying capacity and short-circuit fault withstand capacity, insulated with heat-shrinkable, colour-coded sleeves and supported on suitable DMC/SMC-type busbar supports. Alternatively, suitable high-conductivity copper busbars may be provided. The panel shall be designed and manufactured in accordance with the applicable standards including all accessories listed below, control wiring etc complete all as specified(i) 100 A, 4-pole, suitably rated MCB/MCCB – 02 Nos.(ii) Microprocessor-based Auto Generator Controller (GCU/AMF controller), suitable for automatic mains failure detection, DG start/stop, mains/DG changeover and associated control functions – 01 No.Description item Contd.... Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57660587
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 11.04 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Dg Set For Mil Dental Centre Fatehgarh Cantt
Basic Detail
Tender No 86339/E8
Bidding Type Tender
Location
City Farrukhabad
State Uttar Pradesh
Key Dates
Publish Date 23 Sep 2026
Submission Date 14 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 11.04 Lakhs
Tender Fee 500
EMD 22080
Exemption Not Available
Document List
AppxG.pdf
BOQ_886544.xls
c76cec6e-0297-4426-b5e2-e0427b21d5ba.html
Tenderdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

AppxG.pdf

xls

BOQ_886544.xls

html

c76cec6e-0297-4426-b5e2-e0427b21d5ba.html

pdf

Tenderdocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders