Tender For Supply Installation Testing and Commissioning of Variable Air Volume (Vav) Boxes With Digital Thermostats And Digital Duct Pressure Sensors/Transducers, Including All Associated Works, For Temperature Control In 12000 Cfm Ahu System At Ace
Tender Overview
Project Description
Tender for Supply Installation Testing and Commissioning of Variable Air Volume (Vav) Boxes With Digital Thermostats And Digital Duct Pressure Sensors/Transducers, Including All Associated Works, For Temperature Control In 12000 Cfm Ahu System At Aces 101 To 107.
BOQ
| Sl. No. | Item Description |
| 1 | Elliptical Variable Air volume (VAV) with digital Thermostat |
| 2 | SITC of Pressure Independent Elliptical Variable Air volume (VAV) Boxes. The VAV shall be complete with single / multileaf dampers, The casing shall be made of GSS sheet internally acoustic. VAV Terminal Box Elliptical with/wo flanges, suitable for installation in horizontal ducts Branch/Collars. It shall include all accessories such as Diff. pressure transmitter actuators, aero cross sensor airflow measurement and Solid state electronic actuator with inbuilt DDC/ universal Controller i/c digital thermostat with LCD display which measure/sense air flow and modulate dampers to achieve set temperature via modulate air flow automatically. transformer (220v/24v), Controller/Actuator and factory tested/calibrated values of V-min, V-max, V-nom, feed back control cabling and any other ancillary requirement for the functioning of the units. All controllers used for the control of VAV boxes shall be compliant freely communicable to third party BACnet/ MODBUS IP controllers i/c commissioning complete as required. |
| 3 | 80 -800 cfm VAV Box with Digital Thermostat |
| 4 | DPT /PID multifunctional controller/Transmitter |
| 5 | SITC industrial DPT (Differential Presure Transmitter)/PID multifunctional controller/Transmitter for Air Flow Transmitter to measure and monitor of air flow in Duct or across centrifugal fans with digital display and autozero function having multiple field selecteble measurement units .i.e Volume, Velocity, Pressure (0-2000/2500 Pa) and unique propotional output in voltage (0-10 volt) or current (4-20 mA), communicable to third party BACnet/ MODBUS IP controllers and any other ancillary requirement for the functioning of the units i/c commissioning complete as required. |
| 6 | DPT/PID controller/Transmitter with 0-2000/2500 Pa |
| 7 | GI Ducting |
| 8 | Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required |
| 9 | 0.63 mm (24 g) |
| 10 | 0.80 mm (22 g) |
| 11 | GI duct damper |
| 12 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications complete as required. |
| 13 | GI volume control duct damper |
| 14 | Return Air Grill |
| 15 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 16 | Dismantling old GI Duct |
| 17 | Dismantling and removing of existing old ducts of any size, i/c removing of hangers , flanges , damper, diffuser, grill and depositing in the sectional store complete as reqd. |
| 18 | Dismantling & re-fixing (Modified) ducts |
| 19 | Dismantling & re-fixing of same (Modified) existing old ducts of any size i/c removing of hangers , flanges , damper, diffuser, grill complete as reqd.. |
| 20 | Thermal (XLPE) Insulation with Al. faced on Duct |
| 21 | Providing & fixing of thermal insulation with aluminium foil faced XLPE Class 'O' insulation sheet of following thickness on existing surface of pipe/duct with dendrite/adhesive etc. The joints shall be sealed with 50 mm wide and self adhesive PVC/Aluminium tape complete as required. |
| 22 | 13 mm |
| 23 | Dismantling & re-fixing old grill and diffuser, |
| 24 | Dismantling and refixng of old grill and diffuser, VCD after cleaning as reqd. |
| 25 | Single Phase Plug top |
| 26 | Providing and fixing of Single Phase Plug top ISI Marked for AC (FCU) unit etc i/c dismantling old plug top if any complete as required. (Make:- Anchor or Equivalent) |
| 27 | 3 pin- 6 Amp. |
| 28 | Making wall opening and re-closing for pipe/duct/VAV |
| 29 | Making wall opening up to 750 mm dia/Suitable in any type / thick of wall for pipe/duct etc and re-closing the opening with brick, sand, cement and plaster up to 20 mm i/c re-painting as per existing design/shape complete as required. |
| 30 | Un-armoured Copper power/control cable |
| 31 | Providing, laying, testing, and commissioning of following size Un-armoured XLPE insulated Copper conductor power/control cable of following size on surface/recessed complete as required. |
| 32 | 3 Core x 1.5 Sq mm |
| 33 | PVC conduit along with accessories |
| 34 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 35 | 20 mm |
| 36 | Casing-capping & flexible conduit |
| 37 | Supply and installation UPVC mini trunking (casing-capping) & flexible conduit of following size white-system with independent cover- without central part etc as reqd |
| 38 | Flexi Conduit 20 mm |
| 39 | UPVC trunking 20mm x 12mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender