Drinking Water Supply and Sanitation Local Bodies Closing in 9 days TDR #57659518

Tender For Maintenance And Repair Work And Re Construction Of Storm Water Drain Gandhiji Road Urban Primary Health Center In Ward No - 44

Issued by Local Bodies · Erode, Tamil Nadu
Tender Value
8.30 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
9 days left
EMD
8300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Erode → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance And Repair Work And Re Construction Of Storm Water Drain Gandhiji Road Urban Primary Health Center In Ward No - 44

BOQ

Name of Work:- Maintenance and repair work and Re construction of storm water drain Gandhiji road urban primary health center in ward no - 44
Sl. No. Item Description
1Removing of Existing damaged Doors and Windows including removal of frames, hinges and fastenings and carefully stacking materials useful for re-use etc complete as per standard specification
2Dismantling the existing damaged flooring ceramic tiles including clearing away from the site and all labour charges etc complete .
3Clean removal of cement plaster from the wall surface including clearing materials away from the site and all labour charges etc complete.
4Dismantling the existing damaged Plain cement concrete surface Up to 3M height including clearing away from the site and all labour charges etc complete
5Removing of existing 63mm paver block including cost of all labour charges for disposal from site etc complete.
6Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
7Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers
8Relaying Rubberised interlocking Paver block M40 grade Providing and laying of 63mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, sand cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
9Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 63mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, sand cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
10centering for sides and soffits of R.C.C.works such as lintels, slab that beams plain surface etc., complete excluding strutting upto 3.30 M height using mild steel sheet of size 90 c.m x 60 c.m and 10 gauge stifer with M.S. angles of size 25 mm x 25 mm x 3mm laid over silver w.c.wood joints of size 10 c.m. x 6 c.m. spaced at about 90 c.m. c/c and supported by casurins props of 10 c.m. to 13 c.m. dia spaced 75 c.m. centre to centre complying with as per standard specification
11Plain cement concrete 1:2:4 mix (One cement two M.sand and four aggregate) using 20mm ISS metal including mixing, laying, consolidating, curing cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification - 10m3
12Plastering the surface of walls with Cement Mortar 1:4 (One cement and Four plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers.
13Manufacturing, supplying and fixing of 75mm Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
14Supplying and fabrication placing in position of M.S. (or) RTS rods for required size and length as directed by the departmental officers approved design including bending cutting tying and cost of binding wire cost and conveyance of all materials to site etc., complete as per standard specification - 1 Qtl
15Brick work in Cement Mortar 1:5 mix using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
16Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
17Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
18Dadooing walls with Glazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
19Flooring with ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
20Supply and delivery of PVC Pipe and G.I Pipes Specials approuved quality of departmental officers loading, unloading Cost and conveyance of all materials to Site etc., Complete.
214\\" PVC pipe
224\\" PVC Door Elbow
234\\" PVC Tee
244\\" PVC Aircowl
251\\" PVC pipe
261\\" PVC coupling
271\\" PVC Elbow
281\\" PVC Tee
291\\"X3/4\\" PVC Reducer elbow
3020mm dia pvc Tap
31Laying and Jointing the following PVC Pipes and GI pipes and Specials with proper gradient and test for all labour charges etc., Complete.
324\\" PVC pipe
331\\" PVC pipe
34Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting
35Supplying and fixing PVC low level flushing tank with all internal fittings (wall mounting type) in European Water Closet etc., complete complying with standard specification.
36Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
37Providing UPVC (Un-Plasticized Polyvinyl Chloride)Door: Providing and fixing casement doors fabricatedfrom un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber systemwhich provides high insulation properties with outer frame60mm x 55mm with an outer wall thickness of 2.4mm.The window unit should be designed with all corner jointsmitred and fusion welded. Windows should be steelreinforced with 25 x 24 x 25mm steel reinforcement witha thickness of 1mm to have dimensional stability. Thesash should be of 60 x 102mm. The mullion should be of60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays,handles should be screwed with self tappingscrews. The handles, locks should be designedso that they cannot be released from outside.Glazing: The window system should be glazedwith 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded45 degrees. The window should be designed such that the water drainage does not pass through the reinforcementchamber. The window system should be fixed directly tothe plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
38Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification
39Supply & Installation Of Air-Conditioner With Copper Coil with capacity of 2.0 TR Split Type AC Unit - 5 Star Rated including cost and conveyance of all materials to site and all labour charges etc complete.
40Supply and installation of 4 KVA capacity Automatic Voltage Stabilizer with time delay relay including cost and conveyance of all materials to site and all labour charges etc complete.
41Supply and fixing of MS stand for fixing outdoor unit including standard specification etc complete.
42Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit) including standard specification etc complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57659518
AUTHORITY Local Bodies
TENDER VALUE 8.30 Lakhs
LAST DATE 13-10-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Maintenance And Repair Work And Re Construction Of Storm Water Drain Gandhiji Road Urban Primary Health Center In Ward No - 44
Basic Detail
Tender No E1-3135-2026-ERODE CITY MUNICIPAL CORPORATION
Bidding Type Tender
Location
City Erode
State Tamil Nadu
Key Dates
Publish Date 23 Sep 2026
Submission Date 13 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 8.30 Lakhs
Tender Fee Ref. Documents
EMD 8300
Exemption Not Available
Document List
31a488f8-0d7e-484d-a004-ef08732af4f7.html
BOQ_849872.xls
CONDITION4.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

31a488f8-0d7e-484d-a004-ef08732af4f7.html

xls

BOQ_849872.xls

pdf

CONDITION4.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders