Tender for Repair/ Maintenance Street Lights, High Mast Lights Junction Boxes & Connected Works Of Md Accn At Faridkot Mil Station
BOQ
| Sl. No. | Item Description |
| 1 | Attending the complaints of unserviceable LED street light/high mast light fitting comprising of 45W/ 60W/ 80W/160 Watt of any make any model fitted on the pole at any height with any type of fixing arrangement by taking down and checking loose connection in FRP box/ ACSR conductor or street light and making it serviceable and refixing it to the proper height and removing hanging grasses etc and tightening of all nuts,bolts,clamps and fixing of the street light at proper direction all as directed by Engineer- in- charge. |
| 2 | Attending the complaints of unserviceable high mast light fitting comprising of 80W/160 Watt flood lights of any make any model fitted on the pole at any height with any type of fixing arrangement by taking down and checking loose connection making it serviceable and refixing it to the proper height and tightening of all nuts,bolts,clamps and fixing of the street light at proper direction all as directed by Engineer- in- charge. |
| 3 | M&L in repair of driver suitable for 45 to 60 watt LED street light complete all as per directed |
| 4 | M&L in repair of driver suitable for 80 watt LED flood light complete all as per directed. |
| 5 | M&L in repair of Driver Suitable for 160 watt LED street light complete all as per directed |
| 6 | Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and Fix in replacement power contactor 32 to 40 Amps, for three phase for automatic street light timer complete all as per directed. |
| 8 | M&L in repair Hot moulded (FRP) junction box of size 250mm x 200mm for street light pole with locking arrangement with 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete incl mild steel clamps to fix on pole complete all as specified and directed by Engineer-in-Charge. |
| 9 | S&F in replcement of copper conductor multistranded 1.5 Sqmm 2 core 1100 volts grade complete all as specified and directed. |
| 10 | S&F in replacement PVC insulated multi stranded aluminum conductor cable sheathed 4 sqmm two core and making connections of street light , flood light etc. complete all as directed. |
| 11 | M&L in replacemet twin core 6 sqmm nominal cross sectional area multistranded aluminium conductor cable over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated complete all as specified and directed. |
| 12 | Supply and Fixing or laying XLPE insulated armoured electric power UG cable with aluminium conductor, 1100 volt grade, nominal cross-sectional area 10 sqmm 4 core including terminal lugs and taking down/out unserviceable cable complete all specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks and pipe shall be measured and paid separately under appropriate items. |
| 13 | All as per item No- 12 but of size 16 Sqmm 4 core |
| 14 | All as per item No- 12 but of size 10 Sqmm 2core |
| 15 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out soft/loose soil including returning filing and removal of soil and making good disturbed surfaces complete all as specified and directed |
| 16 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified and directed. |
| 17 | Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed. |
| 18 | Boring/Drilling (horizontally) manually under existing road, pavement, hard standing suitable for passing GI tubing of 40 mm bore complete all as specified. |
| 19 | Supplying and fixing galvanised mild steel pipe /tubing of size 40 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with clamps , bolts , nuts and washers complete all as specified and directed. |
| 20 | Supply and laying double wall corrugated pipe (DWCP) of inner/outer dia 77/63 for underground XLPE LT cable upto size 16 Sqmm, Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified and directed by Engr - in charge |
| 21 | Supply and fix in replacement three phase of 5 KW automatic street light switch using Street light timer switch multi functional digital for automatic switching on & off of street lights at a preset time along with suitable three phase power contactor of 32 to 40 amps current rating, incomming MCB TPN and outgoing TPN MCBs of 32 to 40 Amps and, size of circuit should be multistranded FRLS min size of 6 Sqmm, selection operation should be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof termite proof and FR grade special mounting compound conforming to IP 54 complete all as specified and directed. |
| 22 | M&L for servicing the raising and lowering mechanism of high mast light with opening the gear box and greasing of all moving parts for smooth functioning of raising and lowering of the lantern carriage for maintenance purposes complete all as specified and directed. |
| 23 | Cutting, Trimming of tree branches around 3 meter from over head conductor with necessary tools and ladders completed all as specified and directed |
| 24 | Restreching existing over head lines consisting following lines of ACSR and GI wire any size of 4/5 lines of ACSR conductor and tightening with aluminium binding wire of suitable size complete all as specified and directed. |
| 25 | S&F in replacement aluminium conductor, steel reinforced (ACSR) of any size, any type as per existing one and stringing properly on the insulators and binding with aluminium wire, connectors, jumpers etc complete all as specified and directed. |
| 26 | M&L in replacement of shackle type porcelain, vitreous brown insulator in repair including one galvanised MS strap of size 31x3 mm, 12mm dia insulator bolts washers and nut for 1100 Volts grade 75mm in height and 90mm dia including dismantling of unserviceable LT insulators pin/ shackle/ disc & loop type from existing OH lines complete all as specified and directed. |
| 27 | Detection/finding out the exact LT fault location from both end terminations of underground cable by necessary excavation/earth work or by fault locator machine and making it serveceable and making good the surface as per existing at site complete all as specified and directed. |
| 28 | M&L for heat srinkable type straight through joint outdoor type for LT UG cable 10 to 16 sqmm 4 core including excavation and earth work in any type of soil/ hard standing floor complete all as specified and directed. |
| 29 | Supply, fixing and testing in replacement LED street light luminiareis of 45 Watts system wattage having IP 65 degree of protection, made of pressure die casting aluminum housing power coated in graphite grey and heat resistant toughened glass, voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old u/s street light fittings any type complete all as specified and directed. |
| 30 | Supply, fixing and testing in replacement LED street light luminiareis of 60 Watts system wattage having IP 65 degree of protection, made of pressure die casting aluminum housing power coated in graphite grey and heat resistant toughened glass, voltage range of 150-270 VAC,THD<20%,P.F>.95 and fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including taking down of old u/s street light fittings any type complete all as specified and directed. |
| 31 | Supply, fixing and testing LED flood light in replacement luminiareis of 80 Watts system wattage having IP 65/66 degree of protection,with minimum system efficiency as>85%,made of pressure die casting aluminum housing power coated in graphite grey, operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and builtin surge protector of 5 KV, CCT 5700 K including taking down of old u/s flood light fittings any type complete all as specified and directed. |
| 32 | Supply, fixing and testing LED flood light in replacement luminiareis of 150/160 Watts system wattage having IP 65/66 degree of protection,with minimum system efficiency as>85%,made of pressure die casting aluminum housing power coated in graphite grey, operating voltage range of 150-270 VAC,THD<20%,P.F>.95 and builtin surge protector of 5 KV, CCT 5700 K including taking down of old u/s flood light fittings any type complete all as specified and directed. |
| 33 | Supply, install, testing & commissioning of CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 HZ , AC supply system. The panel shall be factory made, double door outdoor type made out of 2.0 mm thick MS sheet totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 40X40X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc including taking down old unserviceable panel all as directed at site and comprising of the following:-(i) TPN 40 Amp - 01 No (ii) Timer switch for flood lights with contactors- 01 No (iii) Raising and lowering gear control panel with switch for High mast light, min height 16 m - 01 No. |
| 34 | Surface dressing not exceeding 15 cm deep in soft/loose soil including cleaning of E&M installation premises, uprooting of tiny trees, tree cutting , cleaning , leveling , spreading bushes, beeds, grass and removing poly bags, brick bats, stone pebels debris , Cleaning of sub station bldg , two pole / four pole structuire area , HT line etc complete all as specified and directed by Engineer in Charge. |
| 35 | M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 excavation, earth work complete all as specified and directed. |
| 36 | Supply only LT self adhesive PVC electrical insulation tape of size width 25 mm and 25 mtr long complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender