Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57655501

Tender For Repair/Replacement Of Apfc Panels, Perimeter Lights, Steel Tubular Poles Alongwith Allied Cable Works At Clement Town.

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
30 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
19 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Apfc Panels, Perimeter Lights, Steel Tubular Poles Alongwith Allied Cable Works At Clement Town.

BOQ

Name of Work:- REPAIR/REPLACEMENT OF APFC PANELS, PERIMETER LIGHTS, STEEL TUBULAR POLES ALONGWITH ALLIED CABLE WORKS AT CLEMENT TOWN.
Sl. No. Item Description
1Supply , fixing , connecting and commissioning and testing in replacement of power factor improvement panel (APFC) of capacity 50 KVAr, automatic and manual operation for distribution trasformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor). The outdoor panel having suitable/appropriate size as approved in the drg for accomodating capacitor and connected items, Panel should be factory made, weather proof , dust and vermin proof ,IP54 suitable for 440 V grade 3 phase 50 HZ AC supply, PCC plinth mounted , fabricated out of 3.00 mm outer sheet and 2 mm thick inner CRCA sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm, 60 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with light grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles, all as per specified and directed by Engr-in-Charge The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only and comprising of the following :-MCCB 100 A 25 KA 3 pole thermal magnetic – 1 Nos Capacitor 25 KVAR – 01 Nos & duty contactor for 25 KVAR – 01 Nos Capacitor 15 KVAR – 01 Nos & duty contactor for 15 KVAR – 01 Nos Capacitor 4 KVAR – 01 Nos & duty contactor for 4 KVAR – 01 Nos Capacitor 3 KVAR – 01 Nos & duty contactor for 3 KVAR – 01 Nos Capacitor 2 KVAR – 01 Nos & duty contactor for 2 KVAR – 01 Nos Capacitor 1 KVAR – 01 Nos & duty contactor for 1 KVAR – 01 Nos MCB 63 A 10 KA TP for 25 KVAR – 1 Nos MCB 32 A 10 KA TP for 15 KVAR – 1 Nos MCB 16 A 10 KA TP for 4 KVAR and below– 04 Nos APFC Relay 08 stage – 1 No, Indicating light red – 01 No, Auto manual selector switch – as suitable numbers, Indicator light R Y B – 3 Nos, Digital MF meter (0–500 V) – 1 Nos, CT 100/5 A – 3 Nos Bus bar 150 A 3 strip & N/L 100 Amp ALU – 01 strip complete.
2Supply , fixing , connecting and commissioning and testing in replacement of power factor improvement panel (APFC) of capacity 125 KVAr, automatic and manual operation for distribution trasformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor). The outdoor panel having suitable/appropriate size as approved in the drg for accomodating capacitor and connected items, Panel should be factory made, weather proof , dust and vermin proof ,IP54 suitable for 440 V grade 3 phase 50 HZ AC supply, PCC plinth mounted , fabricated out of 3.00 mm outer sheet and 2 mm thick inner CRCA sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm, 60 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with light grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles, all as per specified and directed by Engr-in-Charge The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only and comprising of the following :-MCCB 250 A 36 KA 3 pole thermal magnetic – 1 Nos Capacitor 25 KVAR – 04 Nos & duty contactor for 25 KVAR – 04 Nos Capacitor 15 KVAR – 01 Nos & duty contactor for 15 KVAR – 01 Nos Capacitor 4 KVAR – 01 Nos & duty contactor for 4 KVAR – 01 Nos Capacitor 3 KVAR – 01 Nos & duty contactor for 3 KVAR – 01 Nos Capacitor 2 KVAR – 01 Nos & duty contactor for 2 KVAR – 01 Nos Capacitor 1 KVAR – 01 Nos & duty contactor for 1 KVAR – 01 Nos MCB 63 A 10 KA TP for 25 KVAR – 4 Nos MCB 32 A 10 KA TP for 15 KVAR – 1 Nos,MCB 16 A 10 KA TP for 4 KVAR and below– 04 Nos APFC Relay 08 stage – 1 No, Indicating light red – 01 No, Auto manual selector switch – as suitable numbers, Indicator light R Y B – 3 Nos, Digital MF meter (0–500 V) – 1 Nos, CT 100/5 A – 3 Nos , Bus bar 315 A 3 strip & N/L 315 Amp ALU – 01 strip complete.
3Supply , fixing , connecting and commissioning and testing in replacement of power factor improvement panel (APFC) of capacity 125 KVAr, automatic and manual operation for distribution trasformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor). The outdoor panel having suitable/appropriate size as approved in the drg for accomodating capacitor and connected items, Panel should be factory made, weather proof , dust and vermin proof ,IP54 suitable for 440 V grade 3 phase 50 HZ AC supply, PCC plinth mounted , fabricated out of 3.00 mm outer sheet and 2 mm thick inner CRCA sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm, 60 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with light grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles, all as per specified and directed by Engr-in-Charge The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only and comprising of the following :-MCCB 250 A 36 KA 3 pole thermal magnetic – 1 Nos Capacitor 25 KVAR – 04 Nos & duty contactor for 25 KVAR – 04 Nos Capacitor 15 KVAR – 01 Nos & duty contactor for 15 KVAR – 01 Nos Capacitor 4 KVAR – 01 Nos & duty contactor for 4 KVAR – 01 Nos Capacitor 3 KVAR – 01 Nos & duty contactor for 3 KVAR – 01 Nos Capacitor 2 KVAR – 01 Nos & duty contactor for 2 KVAR – 01 Nos Capacitor 1 KVAR – 01 Nos & duty contactor for 1 KVAR – 01 Nos MCB 63 A 10 KA TP for 25 KVAR – 4 Nos MCB 32 A 10 KA TP for 15 KVAR – 1 Nos,MCB 16 A 10 KA TP for 4 KVAR and below– 04 Nos APFC Relay 08 stage – 1 No, Indicating light red – 01 No, Auto manual selector switch – as suitable numbers, Indicator light R Y B – 3 Nos, Digital MF meter (0–500 V) – 1 Nos, CT 100/5 A – 3 Nos Bus bar 315 A 3 strip & N/L 315 Amp ALU – 01 strip complete.Note : Item No 01 to 03 :- Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage, current,Active power ,apparent Power display of COS Ø ,THD voltage, THD current,alarm indication for defective step,low power factor and access temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement, manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,commissioning without additional setting and programming complete.
4Dismantling and removing and setting aside PCC pole any type by breaking PCC foundation after disconnecting electrical connection incl site clearance complete all as specified and directed by Engr-in- Charge.
5M&L for steel swaged poles complete poles 9 mtr long complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 with one coat of red oxide primer and two coats of aluminium paint and including marking alternate 5 nos black & white strip 30 cm height with two coats of synthetic paint over a coat of primer including preparation of new surfaces complete all as specified and directed.
6Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable complete all as specified and directed.
7Description all as per srl item No-6 above but depth exceeding 1.5 m and not exc 3.0 m complete all as specified and directed.
8Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms. complete all as specified and directed.
9Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point. complete all as specified and directed.
10Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and directed.
11Supply and laying dry river sand laid in trenches as cable cushioning and covering all as directed.Sand cushioning to under ground electric cable 8cm before laying and 15cm after laying the cable intrenches all as specified and directed
12M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
13M&L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in pole foundation, stay pits etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed.
14M&L for PCC 1:2:4 type C-2 using 20 mm graded crushed stone aggregate as in pole foundation, coping etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed.
15Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and directed.
16M&L for LT underground Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 16 Sq mm, 2 core complete all as specified and directed.
17M&L for LT underground Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 10 Sq mm, 4 core complete all as specified and directed.
18M&L for LT underground Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 16 Sq mm, 4 core complete all as specified and directed.
19M&L for LT underground Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 25 Sq mm, 4 core complete all as specified and directed.
20Supply and fix in repair indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as directed by Engr-in charge. complete all as specified and directed.
21M&L in replacement of PVC insulated and sheathed cable of size 1.5 sqmm 3 core copper conductor multistranded 1100 volt grade 230 volts running through PVC conduit of dia 20 mm with strip clamping on poles at 3 places complete all as directed by Engr-in-Charge complete all as specified and directed.
22Material and labour for fixing in replacement GI tubing 50 mm bore light grade, on poles,on walls, under floors, road crossing, as reqd at site complete all as directed by Engr-in Charge. Note: Clamps, Nut bolts, saddle etc will be measured and paid separately. complete all as specified and directed.
23Material and labour for fixing in replacement GI tubing 40 mm bore light grade, on poles,on walls, under floors, road crossing, as reqd at site complete all as directed by Engr-in Charge. Note: Clamps, Nut bolts, saddle etc will be measured and paid separately. complete all as specified and directed.
24S & F and fabrication Street light bracket made out of GI tubing 25 mm to 40 mm dia suitable for 45/60/90 watt LED light light grade upto 1.2 mtr length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
25Labour for repair/maint to Old/Unserviceable LED security/Street/flood light of any capacity incl taking down existing fitting from pole/Bldg for repair of driver ,cable terminal block and connection wire and refixing the same in position after repair incl testing all as specified and directed by Engr-in-Charge. complete all as specified and directed.
26Taking down unserviceable Street/Security light fitting of any type from the pole/bldg after disconnecting electric connection carefully for repl of drivers complete all as specified and directed(Note: Repair/replacement of spares shall be measured seperately)
27Supply and fixing in replacement of electronic driver of cap 45-50 watt of existing make for LED street light fitting complete all as directed by Engr-in-Charge. complete all as specified and directed.
28Supply and fixing in replacement of electronic driver of cap 60-70 watt of existing make for LED street light fitting complete all as directed by Engr-in-Charge. complete all as specified and directed.
29Supply and fixing in replacement of electronic driver of cap 90-100 watt of existing make for LED street light fitting complete all as directed by Engr-in-Charge. complete all as specified and directed.
30Supply and fixing in replacement of electronic driver of cap 120-150 watt of existing make for LED street light fitting complete all as directed by Engr-in-Charge. complete all as specified and directed.
31Supply and fixing in replacement of electronic driver of cap 200 watt of existing make for LED Flood light fitting complete all as directed by Engr-in-Charge. complete all as specified and directed.
32Dismantling and taking down old unsv street/security lights and Material and labour for new LED street light fittings of 60 watt, suitable for upto 50 mm OD holder fixed on existing pole, system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66,TOP opening separate driver compartment with frame, suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole. complete all as specified and directed.
33Dismantling and taking down old unsv street/security lights and Material and labour for new LED street light fittings of 90 watt, suitable for upto 50 mm OD holder fixed on existing pole, system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66,TOP opening separate driver compartment with frame, suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole. complete all as specified and directed.
34Dismantling and taking down old unsv Flood lights and Material and labour for new LED flood light fittings of 100 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole. complete all as specified and directed.
35Dismantling and taking down old unsv Flood lights and Material and labour for new LED flood light fittings of 200 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole. complete all as specified and directed.
36S&F SMC Pole mounted box of size 10\\"x 8\\"x 4\\" with hinged door incl Clamp, nuts, bolts and washers, complete with all as specified and directed and including taking down of old unsv junction boxes. The Box includes :- (a) MCB SP 10 Amp, 10 kA 'C' Series mounted on din rail-1 No. (b) Connector block suitable for 3ph, 4 wire min 16 sqmm cable-1 No complete all as specified and directed.
37Dismantling and taking down Unserviceable earthing and Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. complete all as specified and directed.
38M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed..
39NOTES :-1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57655501
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Apfc Panels, Perimeter Lights, Steel Tubular Poles Alongwith Allied Cable Works At Clement Town.
Basic Detail
Tender No 8131/CLT/E8
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 23 Sep 2026
Submission Date 14 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
98d97abf-6e5c-4431-a518-e006991ac83b.html
BOQ_886474.xls
Tenderdocs8131.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

98d97abf-6e5c-4431-a518-e006991ac83b.html

xls

BOQ_886474.xls

pdf

Tenderdocs8131.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders