| Sl. No. | Item Description |
| 1 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by engr-in-charge. Note : Removing Rubbish material and throwing it outside the empty area. |
| 3 | M&L Vitrified ceramic tiles premium quality light shade 8 to 9 mm thick square /rectangular polished area of each tiles Exc 0.42 Sqm but not exc 1.00 sqm in floors etc .set and pasted tile adhesive and epoxy grouted with same make as of tiles water absorption of the tile should be between 3% to 6% including 15 mm th screed bed CM (1:6) and poined in white or colour cement to match complete all as specified & directed by Engr-In-Charge.Note : adhesive and epoxy measured and paid separately |
| 4 | M&L for applying tile adhesive and epoxy grout for vitrified ceramic tiles complete all as specified and directed. |
| 5 | S&F Premium quality glazed ceramic tile of size 600mm x 300mm thickness 7mm, water absorption between 10% to 20% pasted with spacer, tile adhesive and epoxy grouted with same make as of tile including 15 mm thick rendereing CM (1:4) and poined in white or colour cement to match complete all as specified and directed. |
| 6 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm th screed bed CM (1:6) and poined in white or colour cement to match complete all as specified & directed by Engr-In-Charge. |
| 7 | M&L Granite of any type machine cut 20mm thick, set and jointed in cement slurry over & including screed of 15 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing & with adhesive complete all as specified & directed by Engr-In-Charge. |
| 8 | Taking down cement plaster from ceilings & brick walls including wall tiles / terrazzo / kota stone etc. any type of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engr-In-Charge. |
| 9 | M&L rendering 10mm to 15mm thick in ready mix plaster on any face of brick walls or concrete surfaces, finished even and smooth complete including preparation of newly plastered surfaces of walls etc., complete all as specified & directed by Engr-In-Charge. |
| 10 | M&L preparation newly plastered surface and applying two coat of acrylic exterior emulsion paint over a coatof primer including 1mm thickwall care putty complete all as specified and directed |
| 11 | M&L rendering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement including preparation of new plastered surfaces of walls & applying two coat of oil bound distemper over 1 coat of putty complete all as specified & directed by Engr-In-Charge. |
| 12 | M&L for 10 mm thick plaster on ceiling in cement mortar (1:3) finished even and smooth without using extra cement including applying two coats of OBD on ceiling complete all as specified and directed by Engr-In-Charge. |
| 13 | Taking down of chowkats or frames exc 1.5 Sqm but n exc 4 sqm each with shutters (without taking of shutters from the frames) complete all as specified |
| 14 | Taking down of chowkats or frames n exc 1.5 Sqm each with shutters (without taking of shutters from the frames) complete all as specified |
| 15 | S&F 150mm floor door stopper of aluminium alloy and tongue anodised with hard drawn steel spring fixed in floor complete all specifed and directed |
| 16 | S&F Harrison rails anodised aluminium alloy chromium plated with fixing brackets, stops , roller etc.complete all specified and directed |
| 17 | S&F Powder Coating Anodised aluminium(minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed |
| 18 | S&F Aluminium shutters for door/window / ventilator (glazed and gauzed both),side hung type without sash bars, aluminum section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing, clips, rubber packing, anodised aluminium snap beading screws,aluminium fitting such as peg stays 150mm long (01 nos), hinges type B-21 100mm long (02 Nos) suitable handle (01 No), tower bolt 150 mm long (02 Nos) in each shutter if req with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed.Note: Only Glass and wiremesh will be measured and paid seperately. |
| 19 | M&L 5.5 mm thick, plain sheet glass ordinary quality and glazing with oil putty or with wooden beads in squares exc 0.5 Sqm in each pane complete all as specified by Engineer in Charge. |
| 20 | S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-inCharge. |
| 21 | Complete removal of existing treatment on old wall surfaces of any desciption, preperation of surface by Mechanised sander having suction vaccum bag using smart periodical methodology complete all as specified and directed. |
| 22 | M&L for applying 1mm thick wall care putty on prepared surfaces of walls / Chajja's / facia/ ceiling / Ext surfaces (thickness vary from 1.0 to 1.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 23 | Preparation of surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/10 sqm)and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, |
| 24 | M&L for preparation and two coat of Distempering with 1st quality acrylic distemper (ready mixed) surface by using Roller over complete all as specified and directed. Note : (i) Smooth finished surfaces are considered under Sl item No above.32 (ii) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 25 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed by Engr-in-Charge. |
| 26 | Taking down MCB/ MCCB of any make and making good to disturbed area all as specified and directed by Engr-in-Charge. |
| 27 | Taking down submain wiring 6 sqmm/ 10 sqmm with earthing cable and making good to disturbed area. |
| 28 | Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through existing PVC rigid concealed conduit terminated in & including galvanised steel pressed modular boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with modular cover plate of required size including 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified and as directed:-(a) One light point/Fan point/Exhaust point controlled by one way switch |
| 29 | (b) One light point controlled by one two way switch |
| 30 | (c) One three pin socket out let 5 amps on the same board with other switches |
| 31 | (d) One 3 pin, 5A switch socket outlet point on independent board |
| 32 | All as per item no. 04 here-in-before but with 2.5 sqmm cable for 1 No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor. |
| 33 | Supply and fixing PVC Lamp holder suitable for LED Bulb complete all as specified and directed. |
| 34 | Supply and fixing LED bulb power rating 1x10 Watt having luminous efficancy not less than 100 lumens /watt all as per specification & directed by Engr-in-chrg. |
| 35 | Supply and fixing of LED tube light fiting 20W, (4 feet long) 230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-chrg. |
| 36 | Supply and fixing of LED tube light fiting 10W, (2 feet long) 230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size all as per specification and directed by Engineer-in-chrg. |
| 37 | M&L ceiling rose 3 terminal / PVC / polycarbonate isolated body all as per specification and directed by Engineer-in-chrg. |
| 38 | M&L submain wiring with two single core PVC FRLS insulated copper conductor 2x6 sqmm and same 1x 6 sqmm for continuous earth wire drawn in to existing concealed PVC conduit complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply & fixing ceiling fans BLDC type complete with blades, down rods, Regulator operated and accessories, 230 V, 1200 mm sweep, five star rated with brushless direct current motor (BLDC) complete all as directed.( Old ceiling fan deposit in MES store yard) |
| 40 | Writing MES Nos (Black, Roma, Italic or Indian) n. exc 30 Cm height complete all as specified and directed. |
| 41 | Supply and fixing Modular switch 1 way 6 amps one module switch all as specified and directed by Engr-in-Charge. |
| 42 | Supply and fixing Modular socket 6A 2/3 pin, 2 module socket all as specified and directed by Engr-in-Charge. |
| 43 | Supply and fixing Modular switch 1 way 16 amps 1 module switch all as specified and directed by Engr-in-Charge. |
| 44 | Supply and fixing Modular socket 6A / 16A - 2/3 pin, 2 module all as specified and directed by Engr-in-Charge. |
| 45 | S&Fmodular fan regulator step type AC 230V single pole one module complete all as specified and directed . |
| 46 | Supply and fixing Modular switch 2 way 6 amps one module all as specified and directed. |
| 47 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCCB/MCB shall be measured and paid separately under appropriate item of BOQ. |
| 48 | S&F of MCB DB confirming to IP 43 - IK 09 with double door, SPN 12 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. |
| 49 | S&F sheet metal enclosure for DB's SPN 230 volts 8 way double door complete all as specified and directed. |
| 50 | S&F MCCB 4 pole, 415 V. adjustable type, 100 Amp to 125 Amp with breaking capacity 16 KA complete all as specified and directed. |
| 51 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN current carrying capacity 40 to 63 Amp, in the MCB DB Complete with connection all as specified and directed by Engr-in-Charge. |
| 52 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection all as specified and directed by Engr-in-Charge. |
| 53 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth not less than 1.5 Mtr below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles upto equipment and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 15mm dia upto earthing test point / equipment fixed with 2 Nos. of mold steel clamps made out of 25mm x 3mm flat iron and preforated water pipe 20mm dia galvanized iron pipe heavy grade 2.25 Mtr long and top with socket and plug and bottom connected to earth plate by silt and two bolts / nuts / washers complete with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and cast iron cover with frame all as shown on electrical plate No. 3 of MES Schedule Part - I of SSR-2009 including taking down old Unserviceable earthing any type complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply and fixing in replacement energy efficient LED Security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, all accessories and , including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- |
| 55 | Supplying and fixing and commissioning of electric water heater (Geyser) storage type ABS body of capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for HOt and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable including 15 Amp plug suitable for existing socket and fixing material, 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed .( Old geyser deposit in MES store yard) |
| 56 | Supply and fixing exhaust fan steel body, AC single Phase 230V, 50 Cycle per second, size 300 mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long including hole in wall and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.( Old exhast fan deposit in MES store yard) |
| 57 | Supply and fixing in repair of Modular AC Socket with 25 Amps SP mini MCB, 230 Volts, 50Hz. In 4 module sheet metal enclosure complete all as specified and as directed. |
| 58 | Supply and laying Rigid non-metallic PVC conduit size 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. with all fitting including taking down old Unserviceable pipe any type complete all as specified. |
| 59 | Supply and fixing in replacement of street light fitting bracket, 1.0 mtr long bend to shape made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed. |
| 60 | M&L for cutting chases in brick walls/ PCC for inserting PVC conduit any size and making good with CM 1:3 to finish the surface complete all as specified and directed |
| 61 | Supply and fixing in repair of wall light fitting decorative type suitable for LED lamp complete all as directed. |
| 62 | Supply and fixing in wall mounting fan 400 mm sweep corf operated type complete all as specified and directed. ( Old fan deposit in MES store yard) |
| 63 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core |
| 64 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 160/mm, minimum inside dia 136 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 65 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth mannual excavation for laying of cables, DWCP pipes etc. and getting out soft/loose soil including making good disturbed surfaces of interlocking tiles, road etc complete all as specified and directed |
| 66 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified and directed. |
| 67 | Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed. |
| 68 | S&F GI Pipe 50mm bore light grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed . |
| 69 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying pipes and getting out in soft/loosse soil all as specified and directed. |
| 70 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified and directed. |
| 71 | Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed. |
| 72 | Cutting existing CI/DI pipe 80MM bore branch GI pipe line 50 mm bore and inserting tee including all accessories complete all as specified and directed. |
| 73 | S&F GI Pipe 50mm bore Medium grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed . |
| 74 | S&F GI Pipe 20mm bore Medium grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed . |
| 75 | S&F GI Pipe 25mm bore Medium grade and including GI Fitting in Trenches/on Wall or Laying in floors complete all as specified and directed . |
| 76 | S&F Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 25 mm bore of pipe complete all as specified and directed. |
| 77 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 6000 CuM per hour (or nearest size).(*Steel body) Old desert cooler deposit in MES store yard. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender