Power Government Departments Closing in 11 days TDR #57655457

Tender For Construction Of 132Kv Gss Rvpn Moolana (Jaisalmer)

Issued by Government Departments · Jaisalmer, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2026
11 days left
EMD
49187
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 132Kv Gss Rvpn Moolana (Jaisalmer)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Sep-2026 Important Dates for sale bid Date 06-Oct-2026

BOQ

Name of Work:- Construction of 132KV GSS RVPN Moolana (Jaisalmer)
Sl. No. Item Description
1Construction of 132 KV GSS Moolana (Jaisalmer)
2EARTH MESH WORK Laying of earth mesh with 25/28 mm dia, M.S. Rod at a depth of 0.80 meter from top level of foundation including, excavation of trench of required depth and back filling of the same transportation of M.s Rod from site store to location, welding of M.S Rod to M.S.Rod along the length at crossing and with earth electrode as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80metre below top level of foundation( M.S Rod of above sizes & M.S Flat required shall be made available by RVPN. a)In case electricity is made available by RVPN without charges iii)Soft Rock
3Laying of eathing risers of 50x6mm/50x10mm/50x12mm size M.S Flat at a depth of 0.80 meter from top level of foundation ,including excavation of trench of required depth and black filling of the same ,transportation of M.S Flat from site store to location preparation of risers ,bending as per requirement (after heating if necessary), fixing on and welding /bolting to equipment /structure and peaks of structures, laying in the trench, welding to the earth mesh of M.S. Road as per drawing including welding of extra length, if required ,application of bitumen compound and covering with bitumen impregnated tape on all welded joints ,painting of all surface of risers above ground level with red oxide and green paint for the type of soil prevalent at 0.80 & meter below top level of foundation (M.S pod of above sizes &M.S flat as required shall be made available by RVPN. a)In case electricity is made available by RVPN without charges. iii)Soft Rock
4placing drawing of earth electrode of 25/28mm dia M.S. Rod of length 3.30 metre(app.) to a depth of 3.80 from top level of foundation including, excavation of pit of required depth and back filling of the same transportation of M.s Rod from site store to location,cutting of M.S Rod to desired length preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M.S.Rod as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80metre below top level foundation( M.S Rod of above sizes & M.S Flat required shall be made available by RVPN. a)In case electricity is made available by RVPN without charges. iii)Soft Rock
5placing of earth electrode of 25/28mm dia M.S. Rod of length 7.50metre(app.) to a depth of 8.00meter from top level of foundation including of 200mm dia earth pit having throughout bore of 200mm dia a depth of 8.00meter from top level of foundation in all types of rocks by DTH system and over burden ,including back filling of pit with bentonites slurry (with cost of bentonites slurry ), including its preparation ,transportation of M.S rod and bentonites from site store to location ,cutting of M.S rod desired length welding of earth electrode to earth mesh of M.S.Road as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints,( M.S Rod of above sizes & M.S Flat required shall be made available by RVPN.) a)In case electricity is made available by RVPN without charges.
6ERECTION OF SUB-STATION STRUCTURES columns, beams ,lighting mast and equipment structure(excluding circuit breaker and Capacitor bank) of all types including transportation of structure members, nuts &bolts, washers etc from site store to location their assembly, placing on foundation, fixing of template, with foundation bolts as required leveling and preparing for grouting as required but excluding grouting erection after grouting and tightening & punching of nuts &bolts (maximum length of structures up to 20 Mtrs.)
7BUS- BAR WORK ;-STRINGING OF 220KV,132KV,33KV&11KVbus bar of ACSR conductor , including transportation of conductor ,disc insulator and tension hardware from site store to location laying and cutting required length of conductor, cleaning and assembly of disc insulator as required along with fitting of bolted type or compression type tension hardware as made available (compression machine shall be provided by RVPN on rent free basis )making up at one end, stringing of conductors between the beams with specified sag and tension ,also equalizing sag and fitting spacer T-clamps for twin conductor for three phases of conductors in each bus-section , ii) Single ACSR Zebra
8BUS- BAR WORK:- STRINGING OF 220KV,132KV,33KV&11KVbus bar of ACSR conductor , including transportation of conductor ,disc insulator and tension hardware from site store to location laying and cutting required length of conductor, cleaning and assembly of disc insulator as required along with fitting of bolted type or compression type tension hardware as made available (compression machine shall be provided by RVPN on rent free basis )making up at one end, stringing of conductors between the beams with specified sag and tension ,also equalizing sag and fitting spacer T-clamps for twin conductor for three phases of conductors in each bus-section iii) Double ACSR Zebra
9JUMPERS OF ACSR CONDUCTOR (3NOS Y- type )between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor ,disc insulators and hardware from site store to location ,cleaning and assembly of disc insulator as required, along with fitting of suspension hardware and erection as required cutting required length of conductor making connection ,fixing of spacers & spacer T- Clamps as required ,tightening of clamps/ conductors, dressing etc, for three phases. i) Single ACSR Zebra/Panther Conductor
10STRINGING of earth wire (size 7/3.15mm or 7/4.00mm) including transportation of earth wire, tension hardware’s Etc, from site store to location laying and cutting required length of earth wire flitting of bolted type or compression type hardware as made available (compression machine shall be provided by RVPN rent free basis) making up at one end stringing of earth wire between structure peaks with specified sag and tension ,jumpering and connecting earth bonds single earth wire
11ERECTION OF SUB-STATION EQUIPMENT :i)Erection of 33/0.4kv or 11/0.4kv station transformer up to 500 KVA on existing masonry platform including transportation of transformer & accessories from site store to location eerection of Horn Gap fuse set, jump ring from isolator to Horn Gap to transformer.
12ii)Filtration of the transformer, if required (Additional cost)
13Erection of current transformer/potential transformer/capacitive voltage transformer/ series reactor/residual voltage transformer/neutral current transformer with clamp & connectors, on already erected steel structure including transportationfrom site store to location fabrication of base fram ,fixing of terminal connectors ,tightening of nuts & bolts etc , complete in all respect ii) 132KV CT/PT/CVT
14Erection of current transformer/potential transformer/capacitive voltage transformer/ series reactor/residual voltage transformer/neutral current transformer with clamp & connectors, on already erected steel structure including transportationfrom site store to location fabrication of base fram ,fixing of terminal connectors ,tightening of nuts & bolts etc , complete in all respect iii) 33KV or 11KV CT/PT
15Erection of lightening Arrestor on already erected steel structure including transportation of lightening arrestor ,clamps & connectors surge counter etc. from site store to location fabrication of base frame fixing of terminal connectors ,surge counter, tightening of nuts and bolts etc. complete in all respect. ii) 132KV
16Erection of lightening Arrestor on already erected steel structure including transportation of lightening arrestor ,clamps & connectors surge counter etc. from site store to location fabrication of base frame fixing of terminal connectors ,surge counter, tightening of nuts and bolts etc. complete in all respect. iii) 33KV&11KV
17Erection of isolators on already erected steel structure including transportation of base frame ,PIs contacts mechanism box clamps & connectors etc, from site store to location ,minor fabrication as required ,and fixing of terminal connectors, etc Adjustment /alignment of isolator and its earth blade ,if provided for their smooth operation and final adjustment if required after jumpering. ii) )132KV a)Without Earth blade
18Erection of isolators on already erected steel structure including transportation of base frame ,PIs contacts mechanism box clamps & connectors etc, from site store to location ,minor fabrication as required ,and fixing of terminal connectors, etc Adjustment /alignment of isolator and its earth blade ,if provided for their smooth operation and final adjustment if required after jumpering. ii) )132KV b)With Single Earth Blade
19Erection of isolators on already erected steel structure including transportation of base frame ,PIs contacts mechanism box clamps & connectors etc, from site store to location ,minor fabrication as required ,and fixing of terminal connectors, etc Adjustment /alignment of isolator and its earth blade ,if provided for their smooth operation and final adjustment if required after jumpering iii)33KV&11KV a)Without Earth blade
20Erection of isolators on already erected steel structure including transportation of base frame ,PIs contacts mechanism box clamps & connectors etc, from site store to location ,minor fabrication as required ,and fixing of terminal connectors, etc Adjustment /alignment of isolator and its earth blade ,if provided for their smooth operation and final adjustment if required after jumpering iii)33KV&11KV b)With Single Earth Blade
21Erection of Wave trap on already erected structure beam, including transportation of wave trap ,disc insulators, hardware, clamps and connectors ,etc. from site store to location ,cleaning & assembly of disc insulators along with fitting of suspension arrangement and erection, fixing of terminal connectors etc. ii)132KV
22Erection of 2x33KV or 2x11KV capacitor Bank ,with series reactor &residual voltage transformer /neutral current transformer ,including transportation of equipment ,structure member ,nuts & bolts washers, clamps & connectors etc from site store to location, assembly of structure, their placing on foundation leveling and preparing for grouting as required, but excluding grouting, assembly of capacitor bank cell on frame as required & their connection as per manufacturer’s drawings fixing of terminal connectors etc.
23Erection of 220 KV or 132KV or 33 KV circuit breaker , including transportation of equipment, structures member ,nuts& bolts ,clamps & connectors accessories etc. from site store to location ,assembly of support structure, their placing on foundation ,leveling and preparing for grouting as required ,but excluding grouting .Assembly /placing of support columns /poles mechanism box/control cubicle ,and other accessories as per manufacturers drawing. Fitting of SF 6 gas pipe line , fabrication of air.oil pipe line as required, Electrical wiring from pole to control cubicle, fixing of terminal connectors as required ,but excluding commissioning of CB ,all type of operating mechanism, as required. ii)132KV
24Erection of 220 KV or 132KV or 33 KV circuit breaker , including transportation of equipment, structures member ,nuts& bolts ,clamps & connectors accessories etc. from site store to location ,assembly of support structure, their placing on foundation ,leveling and preparing for grouting as required ,but excluding grouting .Assembly /placing of support columns /poles mechanism box/control cubicle ,and other accessories as per manufacturers drawing. Fitting of SF 6 gas pipe line , fabrication of air.oil pipe line as required, Electrical wiring from pole to control cubicle, fixing of terminal connectors as required ,but excluding commissioning of CB ,all type of operating mechanism, as required iii) 33 KV
25Erection of Post Insulators on already erected structure including transportation of P.I’s nuts &Bolts ,clamps & Connectors etc. from site store to location ,fabrication of base frame & assembly if required, fixing of clamps ,etc. ii)132KV
26Erection of Post Insulators on already erected structure including transportation of P.I’s nuts &Bolts ,clamps & Connectors etc. from site store to location ,fabrication of base frame & assembly if required, fixing of clamps ,etc. iii)33KV or 11KV
27Erection of 132KV Class EHV Transformer (tank already placed on foundation with wheels), including transportation of accessories from site store to location ,erection of HV,IV,LV & Neutral bushing main & OLTC conservators, radiators, equalizing pipe line marshaling kiosk, etc. as per manufacturer’s drawing ,preparation of oil, oil filling dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e. g, Buchholz relay ,MOLG, OSR, etc to marshalling kiosk ,etc. but excluding testing & commissioning of transformer. a) If electricity is available & arranged by RVPN without charges. i) Transformer received oil filled.
28Erection of Control & Relay panel complete in all respect, including transportation from site store to control room , placing on foundation /cable trench as per layout, interconnection between control & relay panel and with existing panel fixing of site /top covers and doors earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. ii)Duplex panel
29Erection of Control & Relay panel complete in all respect, including transportation from site store to control room , placing on foundation /cable trench as per layout, interconnection between control & relay panel and with existing panel fixing of site /top covers and doors earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required iii)Simplex panel, Dc panel, RTCC panel, PLCC panel, etc
30Erection of Control & Relay panel complete in all respect, including transportation from site store to control room , placing on foundation /cable trench as per layout, interconnection between control & relay panel and with existing panel fixing of site /top covers and doors earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required iv) L.T Panel
31Erection of Marshalling Kiosk/Line Matching Unit (LMU)/Line matching& distribution Unit (LMDU) complete in all respect including transportation from site store to location , placing on foundation/ cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. i)220KV/132KVMarshalling Kiosk
32Erection of Marshalling Kiosk/Line Matching Unit (LMU)/Line matching& distribution Unit (LMDU) complete in all respect including transportation from site store to location , placing on foundation/ cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. ii)33KV /11KV Marshalling Kiosk
33Erection of Battery chargers complete in all respect including transportation from site store to location placing on foundation/ cable trench as per layout, etc. ii)110Volt DC,200AH
34BATTERY SET Assembly, erection and commissioning of Maintenance Free VRLA type Battery set including transportation of cells, battery stand electrolyte ,nuts & bolts and accessories from site store to battery room , assembly of wooden stand ,placing the cells on stand ,making their interconnection initial charging and Discharging and final charging as per procedure recommended by Battery manufacturer. a)If electricity is available & arranged by RVPN without charges. ii)110Volt DC,200AH
35LAYING AND TERMINATION OF CABLES: Control Cable: i)Laying of P.V.C insulated unarmoured / armoured control cable of 1.1KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations ,laying in cable trenches, cutting to required length, placing them on cable racks/cable trays /cable batten & dressing ,including removing and re-fixing trench covers as required making necessary connections, testing, cable marking on both the terminating ends, etc. as required for all sizes from 2cx2.5 sq.mm to 20cx2.5sq.mm and 4cx4sq.mm.and 4cx6sq mm. a)Unarmoured control cable
36ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS :12943 &having three matel washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required,& including cost of cable glands, for each cable gland of size. a)19mm unarmoured control cable
37ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS :12943 &having three matel washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required,& including cost of cable glands, for each cable gland of size. c)25mm unarmoured control cable
38ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS :12943 &having three matel washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required,& including cost of cable glands, for each cable gland of size. e)32mm unarmoured control cable
39iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type) as required of Dowell’s or equivalent make as approved by the Engineer –in- charge duly crimped with crimping tool, including making wire ends ready for crimping , ferruling & dressing of wires etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes. a)2x2.5mm
40iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type) as required of Dowell’s or equivalent make as approved by the Engineer –in- charge duly crimped with crimping tool, including making wire ends ready for crimping , ferruling & dressing of wires etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes b)3x2.5mm
41iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type) as required of Dowell’s or equivalent make as approved by the Engineer –in- charge duly crimped with crimping tool, including making wire ends ready for crimping , ferruling & dressing of wires etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes f)12x2.5mm
42iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type) as required of Dowell’s or equivalent make as approved by the Engineer –in- charge duly crimped with crimping tool, including making wire ends ready for crimping , ferruling & dressing of wires etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes h)18x2.5mm
43In case all the wires of any cable are not got terminated, then a deduction at the rate Rs 6.00 shall be made for each end of wires not terminated. i)4x4mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57655457
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 06-10-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Construction Of 132Kv Gss Rvpn Moolana (Jaisalmer)
Basic Detail
Tender No RVPN/SE/TNC/JSM/TN 19/BN 2410002616
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 23 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 2950
EMD 49187
Exemption Available
Document List
68a5aaca-2e49-4095-a746-a2a28e836db6.html
BOQ_1062984.xls
completebiddocument.pdf
Tendernotice_1 (76).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

68a5aaca-2e49-4095-a746-a2a28e836db6.html

xls

BOQ_1062984.xls

pdf

completebiddocument.pdf

pdf

Tendernotice_1 (76).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders