Tender For Repair / Replacement Of Water Distribution System Incl Connected Items Such As Fittings And Control Valve, Repair / Replacement Of Lt Distribution System And Connected Allied Works At Fmme, Toc / Poc, Assaye Line, Meg Offrs Mess & New Tb-I
Tender Overview
Project Description
Tender for Repair / Replacement Of Water Distribution System Incl Connected Items Such As Fittings And Control Valve, Repair / Replacement Of Lt Distribution System And Connected Allied Works At Fmme, Toc / Poc, Assaye Line, Meg Offrs Mess & New Tb-Iii, Cleaning Of Ug Sumps / Oh Reservoir Including Connected Items In The Aor Of Army Units And Repair / Maintenance Of Sewage Treatment Plant At Tb-I Meg & Centre Under Ge (North) Bangalore
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Sep-2026 | 8379Corrigendum | BOQ | 14-Oct-2026 |
| 2 | 14-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in soil for laying of pipe lines. |
| 2 | Returning, refilling incl spreading, levelling watering and well ramming in layers not exceeding 25 cm thick with any type of soil all as directed |
| 3 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed. |
| 4 | M & L excavation in trenches in soft/loos soil not less than 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed. |
| 5 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 6 | Taking up CI/DI water mains (including all fittings), with spigot and socket ends and lead joints/Titan Joints for the following size :- 150 mm bore |
| 7 | All as per item No. 6 above but for100 mm bore |
| 8 | S&F DI pipe (flanged / spigot type) laid in trenches of the following sizes :-150 mm dia |
| 9 | All as per item No. 8 above but for100 mm dia Note :- (i) Cost of CI specials shall be measured and paid separetely. |
| 10 | Cutting of DI/CI pipe in position for insertion of CI/DI specials of following sizes;-150 mm bore |
| 11 | All as per item No. 10 above but for100 mm bore |
| 12 | M&L for CI/DI Specials like bends, tappers, tee pieces all sockets, all spitgot, collars, caps & plugs any size & shape as ordered by Engineer- in- charge incl testing complete as specified & directed for the following sizes:- Up to 150 mm bore |
| 13 | M&L Run lead joint for water mains of the following size of CI pipes :-150mm |
| 14 | All as per item No. 13 above but for100mmNote:- Excavation and earth work shall be measured and paid separately |
| 15 | Dismantaling the sluice valves in various location and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts, gland packing etc and refixing after properly repairs of the following sizes:-200 mm dia bore |
| 16 | All as per item No. 15 above but for150 mm dia bore |
| 17 | All as per item No. 15 above but for100 mm dia bore |
| 18 | M&L for repacking stuffing box of sluice valve spindle including taking a part and reassembling of following sizes:-150 mm bore |
| 19 | All as per item No. 18 above but for100 mm bore |
| 20 | Taking up the old/rusted/unsv GI/CI/HDPE/PPR pipes with fittings and connected control gate valves/ Sluice valve/non return valve/foot valve etc. from sump/ trenches/ floors/roof for the following size:- 20mm dia |
| 21 | All as per item No. 20 above but for25mm dia |
| 22 | All as per item No. 20 above but for40mm dia |
| 23 | All as per item No. 20 above but for50mm dia |
| 24 | All as per item No. 20 above but for80mm dia |
| 25 | All as per item No. 20 above but for100mm dia |
| 26 | S&F GI water tubing medium grade with all fitting (flanged / socket / union / tee etc) laid in trenches / walls / floors / roof of following sizes :-20mm dia |
| 27 | All as per item No. 26 above but for25mm dia |
| 28 | All as per item No. 26 above but for40mm dia |
| 29 | All as per item No. 26 above but for50mm dia |
| 30 | All as per item No. 26 above but for80mm dia |
| 31 | All as per item No. 26 above but for100mm dia |
| 32 | S&F in repair brass non return valve of the following size dia internal threded type complete including taking down the existing all as specified and as directed.63/65/80 mm dia |
| 33 | All as per item No. 32 above but for100 mm dia |
| 34 | Supply & fixing in replacement of the following size gun metal Gate valve with iron wheel.20 mm dia |
| 35 | All as per item No. 34 above but for25 mm dia |
| 36 | All as per item No. 34 above but for40 mm dia |
| 37 | All as per item No. 34 above but for50 mm dia |
| 38 | Dismantling Old valve pit complete with deteriorated MS cover and Construction of brick massonry valve pit chamber of inner dimension 150x150x100 cms suitable for sluice valves upto 150mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement . |
| 39 | S&F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insortion packing 6mm thick etc of following sizes:-200 mm dia bore |
| 40 | All as per item No. 39 above but for150 mm dia bore |
| 41 | All as per item No. 39 above but for100 mm dia bore |
| 42 | Removing of unserviceable foot valve from tank and replacement with new CI foot valve ball type of following sizes:-150/100 mm dia bore |
| 43 | All as per item No. 42 above but for100/80 mm dia bore |
| 44 | All as per item No. 42 above but for50/63 mm dia bore |
| 45 | Removing old unserviceable float valve from service tank supply and fix float valve with PVC body aluminium float rod, nylon float high pressure type (Make:- Prayag) for the following size:-20 mm bore |
| 46 | All as per item No. 45 above but for25 mm bore |
| 47 | Taking out old unserviceable foot valve from UG sump and removing unserviceable leather from suction line and replacement the same with high quality leather including nuts, bolts, washer etc and servicing for the following sizes. 150 mm bore |
| 48 | All as per item No. 47 above but for100 mm bore |
| 49 | All as per item No. 47 above but for80 mm bore |
| 50 | Supply and installation with testing complete of digital water level indication device operating on single phase supply direct display in 19 mm size (letter display) digit system in meter/CM of water of overhead tank ensuring alarm while water fall or rise over predetermined limits with the following description complete all as specified and as directed by Engineer-in-charge including dismantling old unserviceable water level indicator.(a) The entire unit must operate through a compact electronic circuit which must ensure reliable operation at 230V +10% at 50 Hz +5%, with reliable in display and alarm at low and high level head tank.(b) One circuit must be housed in high impact polystyrne molded box nylon mlded connection strips. The level system must resistance transducer, while unattested by corrosion and other contents avilable in water the product must be controlled by Micro switch.(c) The whole unit must electronically contolled and the upper level and lower level indications must be in two parts. Each complete part must be fitted in MS CRS sheet box separetaly. One must be installed at over head tank and second at pump house with proper powder coating paint with locking arrangements. |
| 51 | M&L for testing 03/04 core copper conductor PVC insulated heavy duty unsheathed cable 1100 volts grade 0.5 Sqmm from control box to display meter in ducts/on ground/through existing pipes etc including taking out unserviceable flexible cable all as specified and as directed. |
| 52 | M&L in replacement of Mechnical joints with rubber washer, nuts and bolts as existing at site of the following sizes of CI/DI pipes :-150 mm bore |
| 53 | All as per item No. 52 above but for100 mm bore |
| 54 | S&F in replacment of Air release valve of existing size suitable for centrifugal pump set complete all as specified and as directed. |
| 55 | Supply and installed avaiation lights of LED Based all as specified and directed by Engr-in-Charge. |
| 56 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 32x6mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2020 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. |
| 57 | M&L for Air termination single pointed aluminium rod 12mm dia and 300mm long |
| 58 | M& L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex, head screw. |
| 59 | M&L for Aluminium Strip 25x3.15mm with saddles and fixing screws etc, for roof conductors and down conductors above ground. |
| 60 | Supply and filling Calcium hypochlorite granular (65-80% chorine contect)disinfectant in Sumps complete as specified and directed by Engineer-in-charge |
| 61 | M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the sump suitable to store potable drinking water incl one coat white washing inside and marking outside sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:-Capacity of 10000 ltrs |
| 62 | All as per item No. 61 above but forCapacity of 5000 gallon |
| 63 | All as per item No. 61 above but forCapacity of 7500 gallons |
| 64 | All as per item No. 61 above but forCapacity of 10000 gallons |
| 65 | All as per item No. 61 above but forCapacity of 15000 gallons |
| 66 | All as per item No. 61 above but forCapacity of 25000 gallon |
| 67 | All as per item No. 61 above but forCapacity of 35000 gallons |
| 68 | All as per item No. 61 above but forCapacity of 38000 gallons |
| 69 | All as per item No. 61 above but forCapacity of 50000 gallons |
| 70 | All as per item No. 61 above but forCapacity of 60000 gallons |
| 71 | All as per item No. 61 above but forCapacity of 80000 gallons |
| 72 | All as per item No. 61 above but forCapacity of 96000 gallons |
| 73 | All as per item No. 61 above but forrCapacity of 100000 gallons |
| 74 | All as per item No. 61 above but forCapacity of 350000 ltrs |
| 75 | All as per item No. 61 above but forCapacity of 150000 gallons |
| 76 | All as per item No. 61 above but forCapacity of 300000 gallons |
| 77 | M & L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the OH reservoir of any staging suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of Tank, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following overhead reservoirs including staging:-Capacity of 10000 gallons |
| 78 | All as per item No. 77 above but forCapacity of 15000 gallons |
| 79 | All as per item No. 77 above but forCapacity of 21000 gallons |
| 80 | All as per item No. 77 above but forCapacity of 25000 gallons |
| 81 | All as per item No. 77 above but forCapacity of 35000 gallons |
| 82 | All as per item No. 77 above but forCapacity of 50000 gallons |
| 83 | All as per item No. 77 above but forCapacity of 60000 gallons |
| 84 | All as per item No. 77 above but forCapacity of 80000 gallons |
| 85 | All as per item No. 77 above but forCapacity of 100000 gallons |
| 86 | All as per item No. 77 above but forCapacity of 150000 gallons |
| 87 | S & F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt,washers and rubber insortion packing 6mm thick etc of following sizes:- 200 mm dia bore |
| 88 | All as per item No. 87 above but for150 mm dia bore |
| 89 | All as per item No. 87 above but for100 mm dia bore |
| 90 | All as per item No. 87 above but for80 mm dia bore |
| 91 | M & L for sand cushioning with a layer of dry sand 23 cm thick under and above the cable complete all as specified and as directed |
| 92 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 93 | Taking down old unsv/burnt XLPE cable from trench/wall/pole of following size :- 2 C x 10 Sqmm |
| 94 | All as per item No. 93 above but for4 C x 10 Sqmm |
| 95 | All as per item No. 93 above but for4 C x 16 Sqmm |
| 96 | All as per item No. 93 above but for3.5 C x 25 Sqmm |
| 97 | All as per item No. 93 above but for3.5 C x 35 Sqmm |
| 98 | All as per item No. 93 above but for3.5 C x 50 Sqmm |
| 99 | All as per item No. 93 above but for3.5 C x 70 Sqmm |
| 100 | All as per item No. 93 above but for3.5 C x 95 Sqmm |
| 101 | All as per item No. 93 above but for3.5 C x 120 Sqmm |
| 102 | All as per item No. 93 above but for3.5 C x 150 Sqmm |
| 103 | All as per item No. 93 above but for3.5 C x 185 Sqmm |
| 104 | Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable for following size :-2 C x 10 Sqmm |
| 105 | All as per item No. 104 above but for4 C x 10 Sqmm |
| 106 | All as per item No. 104 above but for4 C x 16 Sqmm |
| 107 | All as per item No. 104 above but for3.5 C x 25 Sqmm |
| 108 | All as per item No. 104 above but for3.5 C x 35 Sqmm |
| 109 | All as per item No. 104 above but for3.5 C x 50 Sqmm |
| 110 | All as per item No. 104 above but for3.5 C x 70 Sqmm |
| 111 | All as per item No. 104 above but for3.5 C x 95 Sqmm |
| 112 | All as per item No. 104 above but for3.5 C x 120 Sqmm |
| 113 | All as per item No. 104 above but for3.5 C x 150 Sqmm |
| 114 | All as per item No. 104 above but for3.5 C x 185 Sqmm |
| 115 | M&L for replacement of iron work of any type incl cross arms, supports, bracing MS clamps etc made out of MS channel/angle iron/flat iron/ round section of any size and bolt nuts and washer incl painting with two costs of aluminium paint over a coat of red oxide all as specified and as directed |
| 116 | M&L in replacement of pin type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 100 mm height and 65mm dia for 1100 volts grade complete all as specified and as directed |
| 117 | M & L in replacement of shackle type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 75 mm height and 90mm dia for 1100 volts grade complete all as specified and as directed |
| 118 | M & L in repair for GI tubing light grade 40mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 119 | M & L in repair for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 120 | M & L in repair for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 121 | M & L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed incl dismantling and taking out old U/S. |
| 122 | M & L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.incl dismantling and taking out old U/S. |
| 123 | M & L for tightening of ACSR (Aluminium conductor steel reinforced) conductor of any size between two poles 04/06 runs of conductor incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed |
| 124 | S & F in replacemet of UNSV existing /suitable size MCCBs 4 pole 415 Volts 50HZ incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as underMCCB 100 Amps ,16 KA with adjustable Thermal setting |
| 125 | All as per item No. 124 above but forMCCB 200 Amps 36 KA with adjustable Thermal setting . |
| 126 | All as per item No. 124 above but forMCCB 250 Amps 36 KA with adjustable Thermal setting . |
| 127 | All as per item No. 124 above but forMCCB 315 Amps 36 KA with adjustable Thermal setting. |
| 128 | All as per item No. 124 above but forMCCB 63 Amps, 25 KA with adjustable Thermal setting |
| 129 | M & L for replacement of LT 2 line separator 230 volts 50 Hz all as specified as directed |
| 130 | M & L for replacement of LT 4 line separator 415 volts 50 Hz all as specified as directed |
| 131 | M&L in repair for cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core/4core XLPE armoured aluminium conductor cable for following sizes:-3.5 C x 25 to 35 Sqmm |
| 132 | All as per item No. 131 above but for3.5 C x 50 to 120 Sqmm |
| 133 | M&L for painting of steel tubular/PCC poles of any height and type ,incl security light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed. |
| 134 | Dismantling of ACSR (Aluminium conductor steel reinforced) conductors |
| 135 | M&L of ACSR (Aluminium conductor steel reinforced) conductor of any size on poles incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed |
| 136 | Refixing of ACSR conductor connected with new existing wire tightening to insulator incl line clearance by pruning of tree branch approx 1 m apart from conductor tightening side. |
| 137 | Stay assembley complete with all accessories as shown in elect plate No 1 of SSR Part-I consisting of stay rod 20mm dia 1.8 mtr long,size of stay plate 230 x 230 x 6 mm with nuts,bolts,insulator stay clamps etc. complete all as shown on drawing and as directed Note:- Excavation and stay wire shall be measured and paid separately |
| 138 | M&L for galvanized stay wire stranded 7/4 mm complete all as specified and as directed |
| 139 | Dismantling the damaged unservicable pole of any type. |
| 140 | Supply and errect steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410SP-31, 9 mtr long . |
| 141 | M&L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole,filling and mass concrete of pole, make good to road surface , hard standing etc incl necessary form work all as specified and as directed |
| 142 | M&L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed |
| 143 | M&L for in repair outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 400 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 250 Amps 36 KA .including removing old unserviceable junction box complete all as specified and as directed |
| 144 | Supply and fix in replacement of Timeline distribution board 32 A 3 pole /230V analog time switch including complete accessories relay contactor, timer etc, all as specified and as directed. Make:- Indoasian Cat No. TL032AB0 |
| 145 | Supply and fixing,replacement of moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as directed |
| 146 | Supply and fixing 60 W LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. |
| 147 | Supply and fixing 90 W LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07. 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. |
| 148 | S&F in replacement of 2 runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length. |
| 149 | Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 100 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks INDOASIAN or Havells/L&T/Standard. |
| 150 | Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 400 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks |
| 151 | Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 60W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 152 | Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 90 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 153 | Dismanling and taking out the flood light from high mast pole and removing the burned out/unserviceable LED driver 200 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 154 | S&F in repair 200W LED flood light luminaries with innovative die-cast aluminium flood light with highly efficient LEDs as light source, suitable for highmast lighting with complete accessories including taking down old unserviceable flood lights from high mast pole all as specified and as directed. |
| 155 | S&F in replacement of new generation 25 Watt post top energy saving IP-65 enviornmental, friendly long life with symmetrically light distribution, spun aluminium with high power |
| 156 | M&L for painting of outdoor type Feeder piller panel upto the size of 1100 x 450 x 1200 mm (approx), incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed. |
| 157 | M&L for painting of outdoor type Lt panel upto the size of 2500 x 600 x 3000 mm (approx), incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed. |
| 158 | Boring of holes under road, pavement, hard standing by trenchless techless using ultra sounding technique and necessary machine including HDPE pipe of 63 mm dia bore suitable for 0.4 mpa working pressure. |
| 159 | M&L in for repair of LT panel upto the size of 2500 x 3000 mm (approx), incl replacement of door hinges with new one and duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of smoke grey colour as directed by Engineer-in-charge complete all specified and as directed. |
| 160 | Supply, installtion,testing commisioning of LT panel, out door type of size not less than 1900x1300x500mm, , platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 75x75x6mm angle iron frame work, having front & rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts and washers. The cabinet & all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection of MCCB should be provided with Al strip of suitable size and necessary grouting/ foundation all as required at site and comprising following: including dismantling and taking down of old unsv panel complete including replacement of lugs for incoming / outgoing cables as per existing all as specified.BUS BAR - Aluminium bus bar system of capacity 600 amp four pole duly colour coded.INCOMER - MCCB, 4 pole of capacity 400 amps with breaking capacity of 36 KA . - 01 No.Outgoing - (a) MCCB, 4 pole of capacity 250 amps with breaking capacity of 25 KA . - 01 No.(b) MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 02 No.(c) MCCB, 4 pole of capacity 100 amps with breaking capacity of 25 KA . - 01 No.(d) MCCB, 4 pole of capacity 63 amps with breaking capacity of 25 KA . - 01 No.(e) MCB, 4 pole of capacity 32 amps with breaking capacity of 10 KA . - 02 No.(f) MCB, 4 pole of capacity 63 amps with breaking capacity of 10 KA . - 01 No.(g) MCB, 4 pole of capacity 6 amps with breaking capacity of 10 KA . - 01 No. (h) Timer switch and contactor for switching ON/ OFF Street light daily astronomical calculation of sunrise/sunset timesbased on intered loc or loc coordinates. Nos-01Digital multimeter - 01 NoPhase Indicator Lamp RYB with sheds LED Type - 01 Set of three |
| 161 | Dewatering and pumping out of existing CCT / treated water tank at STP by using external sewage disposal pump set to near by sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. |
| 162 | Dewatering and pumping out of existing accumulated sludge from SBR tank at STP by using external sewage disposal pump set to near by sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10 Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. Please Enable Macros to View BoQ information |
| 163 | Dewatering and pumping out of existing accumulated sludge from SBR tank at STP by using external sewage disposal pump set to near by sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10 Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender