Tender For Repair/ Replacement Of Underground Pipe Lines, Sluice Valves, Nrvs, Arv, Valve Pit Chambers, Joints, Laggings And Other Connected Works Under Ge (Af) Srinagar.
Tender Value
26 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
16 days left
EMD
52000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Underground Pipe Lines, Sluice Valves, Nrvs, Arv, Valve Pit Chambers, Joints, Laggings And Other Connected Works Under Ge (Af) Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of hard/ dense soil. Complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested complete, all as specified and directed by Engineer-in-Charge |
| 3 | Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engineer-in-Charge |
| 4 | Taking up or down old unseviceable GI pipe of size 150 mm dia including all fittings complete all as specified and directed by Engineer-in-Charge. |
| 5 | All as per ser item 04 here-in-before but of 100 mm dia |
| 6 | All as per ser item 04 here-in-before but of 80 mm dia |
| 7 | All as per ser item 04 here-in-before but of 50 mm dia |
| 8 | All as per ser item 04 here-in-before but of 40 mm dia |
| 9 | All as per ser item 04 here-in-before but of 25 mm dia |
| 10 | All as per ser item 04 here-in-before but of 20 mm dia |
| 11 | All as per ser item 04 here-in-before but of 15 mm dia |
| 12 | S&F and testing of GI pipes of size 150 mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified and directed by Engr-in-Charge. |
| 13 | All as per ser item 12 here-in-before but of 100 mm dia |
| 14 | All as per ser item 12 here-in-before but of 80 mm dia |
| 15 | All as per ser item 12 here-in-before but of 50 mm dia |
| 16 | All as per ser item 12 here-in-before but of 40 mm dia |
| 17 | All as per ser item 12 here-in-before but of 25 mm dia |
| 18 | All as per ser item 12 here-in-before but of 20 mm dia |
| 19 | All as per ser item 12 here-in-before but of 15 mm dia |
| 20 | Refixing GI serviceable pipe obtained from taking down and connect in new or old position (walls, trenches, ceiling and floors etc) of size 150 mm dia complete including main branch connections including new fittings all as specified and directed by Engr-in-Charge. |
| 21 | All as per ser item 20 here-in-before but size 100 mm dia. |
| 22 | All as per ser item 20 here-in-before but size 80 mm dia. |
| 23 | All as per ser item 20 here-in-before but size 50 mm dia. |
| 24 | All as per ser item 20 here-in-before but size 40 mm dia. |
| 25 | All as per ser item 20 here-in-before but size 25 mm dia. |
| 26 | All as per ser item 20 here-in-before but size 20 mm dia. |
| 27 | All as per ser item 20 here-in-before but size 15 mm dia. |
| 28 | Taking up or down old unseviceable CI water mains of 150 mm diameter (including all fittings), with Spigot and Socket ends and lead joints including burning out joints, all as specified and directed. |
| 29 | All as per item no 28 here in above but size 100 mm bore dia. |
| 30 | Relaying cast iron CI pipes of 150 mm bore diameter with Spigot and Socket ends after cleaning internal surface of serviceable pipes retrieved from taking down, by using of wire brush and cleaning thoroughly with fresh water and taking out mud/soft deposited inside the pipes. |
| 31 | All as per item no 30 here in above but size 100 mm bore diameter |
| 32 | Supply, laying and testing of CI pipes 150 mm bore diameter with Spigot and Socket ends centrifugally cast, Class LA, in any length laid in trenches all as specified and directed by Engr-In-Charge |
| 33 | All as per item no 32 here in before but 100 mm bore diameter |
| 34 | M&L for CI bends, Tees, collar, Tail piece etc (any type & shape and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for CI pipe upto 150 mm dia. ( Excavation and earthwork measured and paid separately) |
| 35 | M&L for Lagging upto 25mm bore pipes used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh including applying with brushing neat cement slurry with 3 kg of cement per Sqm including taking down of old lagging if required, complete all as specified and directed. |
| 36 | S&F in replacement cast iron sluice valve suitable of size 150 mm (PN 1.6) ISI Marked with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed by Engr-in-Charge.. |
| 37 | All as per ser item 36 here-in-before but size 100 mm dia |
| 38 | All as per ser item 36 here-in-before but size 80 mm dia |
| 39 | S&F in replacement of cast iron non return valve suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,Complete all as specified and directed by Engr-in-Charge. |
| 40 | All as per ser item 39 here-in-before but size 100 mm dia. |
| 41 | S&F in replacement Cast iron Foot valve Flanged with strainer of 100 mm dia including all types of fittings conforming to IS specification complete all as specified and as directed. |
| 42 | S&F in replacement cast iron air release valve with two air outlets of size 100 mm dia including all jointing materials like high pressure rubber gasket nuts, bolts, washers with arrangement for fixing, including taking down complete,complete all as specified and directed by Engr-in-Charge. |
| 43 | All as per ser item 42 here-in-before but size 80 mm dia. |
| 44 | Repair to old sluice valve of size 150 mm dia for check nut, spindle, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing complete all as directed . |
| 45 | All as per ser item 44 here-in-before but size 100 mm dia |
| 46 | All as per ser item 44 here-in-before but size 80 mm dia Please Enable Macros to View BoQ information |
| 47 | All as per ser item 44 here-in-before but size 80 mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender