Public Administrative Department Local Bodies Closing in 0 days TDR #57648364

Tender For Provision Of 03 Nos. New Outer Units Of Pnc Ac Plant Of Diakin Make At Hindu Rao Hospital

Issued by Local Bodies · Delhi, Delhi
Tender Value
15.66 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
0 days left
EMD
33000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of 03 Nos. New Outer Units Of Pnc Ac Plant Of Diakin Make At Hindu Rao Hospital

BOQ

Name of Work:- Provision of 03 nos. new outer units of PNC AC plant of Diakin make at Hindu Rao Hospital
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliverthe rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. Theunit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) For Cooling or Heating or Both
210 HP to 12 HP (10 HP)
310 HP to 12 HP (12 HP)
414 HP to 22 HP (20 Hp)
5Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copperrefrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulationas given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
628.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
722.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
819 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
915.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
1012.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
119.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
126.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
13Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs.
14Outdoor Multi Joint
15Indoor units
16Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 X 1.5 sq. mm
17Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
18Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*120 sqmm
19Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size on wall surface asrequired. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
20Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45mm)
21Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
22Supply,Installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed Al bus bar 400A to 630A with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators ) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623)
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 400 A,50KA,FPMCCB
24Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 125 A,36KA, FPMCCB
25Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. 200 A,36KA,FPMCCB
26Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*50 sqmm
27Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
28Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm)
29Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
30Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57648364
AUTHORITY Local Bodies
TENDER VALUE 15.66 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of 03 Nos. New Outer Units Of Pnc Ac Plant Of Diakin Make At Hindu Rao Hospital
Basic Detail
Tender No 35/MWEEE-I/2026-27/TC
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 23 Sep 2026
Submission Date 30 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 15.66 Lakhs
Tender Fee 590
EMD 33000
Exemption Not Available
Document List
2e6f37ff-07ff-41a0-8d7e-9b18c188da21.html
BOQ_340288.xls
DNIT01.pdf
Tendernotice_1.pdf
Tendernotice_2 (2).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
html

2e6f37ff-07ff-41a0-8d7e-9b18c188da21.html

xls

BOQ_340288.xls

pdf

DNIT01.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders