Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57647127

Tender For Certain Sanctioned Works At Pooh Division Under Area Of Age B/R -I Pooh Of Ge 863 Ews

Issued by Statutory Bodies & Commissions/Committees · Kinnaur, Himachal Pradesh
Tender Value
29.96 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
10 days left
EMD
59920
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kinnaur → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Certain Sanctioned Works At Pooh Division Under Area Of Age B/R -I Pooh Of Ge 863 Ews

BOQ

Name of Work:- CERTAIN SANCTIONED WORKS AT POOH DIVISION UNDER AREA OF AGE B/R -I POOH OF GE 863 EWS
Sl. No. Item Description
1Dismanling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
2Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed
3Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
4Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil.
5M & L for Cement concrete type D2 1:4:8 using 40mm graded stone aggregate in foundations, filling and mass concrete.
6M & L for Pre-cast cement concrete type B1 1 : 3 : 6 block masonry with solid blocks, exc. 10 cm in width and setting in mortar (CM 1:6) complete all as specified and directed.
7M & L for 40 mm thick Cement Concrete M-15 Nominal Mix (using 12.5 mm graded stone aggregate) as in damp proof course (DPC) to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. NOTE: - water proofing compound will be measured and paid separately.
8Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
9Returning filling in including speading,leveling ,watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed by Engr-in-Charge.
10Removing of excavated Soil n exc 50m and depositing where directed at a level n.exc 1.50m above the starting point.
11S & F steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to I.S.1161- 1979 Fe 410-W (GdeE- 250) complete all as specified and as directed by Engineer-In-charge
12S&F Pre-painting galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed
13S&F Pre-painting galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed
14M & L for preparation of new steel surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed.
15Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets.
16Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work.
17-Ditto- all as per item above but in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section.
18M & L for second class hardwood clean sawn scantlings as in timber framed and fixed complete all as specified and directed.
19M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 3 & n.exc 6 sq.cm complete all as specified and directed.
20M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & n.exc 25 sq.cm complete all as specified and directed.
21M & L for 6mm thick (No of ply 5) plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed.
22M & L for 9mm thick Particle board one side, medium density flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screw to timber frame work complete all as specified and directed.
23M & L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
24Taking down chowkats or frames not exc 1.5 sq.m each but with shutters (without taking off shutters from the frames).
25Taking down chowkats or frames exc 1.5 sq.m but n.exc 4 sq.m each but with shutters (without taking off shutters from the frames).
26S & F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
27S & F of 35 mm thick (Batten thickness) 2nd class hardwood plain, framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or od veneered particle board of medium density , wood particle board with commercial face veneers and fitted to chaukhats complete all as specified and directed.
28S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed.
29S & F of 30 mm thick (Batten thickness) 2nd class hardwood plain, framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or od veneered particle board of medium density , wood particle board with commercial face veneers and fitted to chaukhats complete all as specified and directed.
30S & F of 30 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed.
31M & L sheet glass, 4mm thick ordinary quality and glazing with oil putty or beadings in square not exc 0.5 sqm in each pane.
32S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and directed.
33S & F clamps, hold fast,hook washer & similar small articles conforming to Fe-290 Gde-E-165.
34M & L for providing cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in hold fast blocks.
35S & F 125mm butt hinges, medium weight, cold rolled mild steel and fixed.
36S&F butt hinges, medium weight, cold rolled mild steel, size 100mm.
37-Ditto- all as per item above but 75mm long.
38S & F 300mm length aluminium alloy, anodised, sliding door bolt hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
39S & F 150mm Aluminium handles, cast type, anodised
40S & F 125mm Aluminium handles, cast type, anodised
41S & F 150mm aluminium, anodised, barrel tower bolts of extruded section and fixed.
42S & F 125mm aluminium, anodised, barrel tower bolts of extruded section and fixed.
43S & F in repair hydraulically regulated door closer, (die cast) body designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and weight b/w 61 to 80kg complete.
44S & F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate complete.
45Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed.
46M &L 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate finishing surface even and smooth wuthout using extra cement a in plinth protection all as specified and directed.
47M &L 75mm thick cement concrete type D2 1:4:8 in sub base floor complete all as specified and directed.
48M & L for 25 mm thick PCC 1:2:4 type B1, 20 mm graded stone aggregate as in flooring including finishing cement concrete rough surface with out using extra cement.
49M &L chequered cement concrete tile 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry over 20mm thick scrred bed in cement mortar 1 :4 as in floors with grey cement and pigment complete all as specified and directed.
50Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
51M & L for vitrified ceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge.
52M & L for vitrified ceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in dado/ skirting in verticle surfaces etc floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge.
53M & L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
54M & L for Granite tiles 20mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture and pigment to match the shade of Granite stone incl grinding and polishing complete all as specified.
55M&L for machine cut kota stone slab flooring of size 50cmx50cmx 18 to 20 mm thick over cement screed bed 20 mm thick cement plaster 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
56M & L for non skid coloured ceramic tiles 7 to 8mm thick square / rectangular area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor laid over 15 mm thick screed bed in CM 1:6 as in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile complete all as specified and directed by Engr-in-charge.
57M & L for Glazed ceramic coloured tiles of size 300 mm X 200 mm X 7 mm thick as on vertical surfaces such as skirting, dados and rises to steps etc. over 10mm thick screed bed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
58M & L for precast cement concrete M-15 Nominal Mix (1:2:4) (using 20 mm graded stone aggregate), as in lintels upto 1.5 m clear span, cills, steps,seismic and other similar bands, plinth course, string courses, lacinng courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
59M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
60M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
61M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed.
62Demolition of brick work or stone / boulder massonary, build in cement mortar incl all quoins , pillers etc.
63M & L for Precast cement concrete block massonary 1:3:6 type C1 with solid block exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by E-in Charge.
64Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc.
65M & L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed.
66M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement).
67M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4and finished even and smooth (without using extra cement).
68Supply only Integral water proofing compound (WPC)
69M & L complete removal of existing treatment and applying 3mm thick Birla wall care putty and applying two coats of distemper oil emulsion over a coat of primer on wall complete all as specified and directed.
70M & L for preparation of new plastered surface or previously untreated walls surfaces and applying two coats of cement base paint over coat of primer on wall complete all as specified and directed.
71M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
72Taking up or down 15mm bore steel water tubing & connections, incl cleaning for existing or offrening credit as per sch of credit all as directed.
73S&F 15 mm dia of pipe Gun-metal, globe or gate valvees with iron wheel head, screwed both ends for iron pipe and fixed.complete all as specified and directed by Engr In Charge.
74S&F 15mm bore galvanised steel tubes, 'medium grade' with all fitting and fixed complete to walls and ceiling or laid in floors completed all as specified and directed by E-in-Charge
75S&F 20mm bore Galvanised steel tubes, 'medium grade' with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr In Charge..
76S&F in repair bib taps 15mm dia fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge.
77S&F in repair 15mm dia stop valve chromium plated, fancy type screwed down, high pressure with crutch or butterfly handle screwed both end for iron pipe complete all as specified and directed by Engr In Charge.
78S&F in repair PVC connections 45cm long and 15mm dia chromium plated brass nuts and PVC washers on both ends, complete all as specified and directed by Engr In Charge.
79S & F in repairs for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed.
80Supply & fixing in repair 15mm pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down , high pressure, with or without lettered 'Hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge..
81S&Fin repairs PVC Valveless, syphonic action type, flushing cistern of 10ltr capacity, high or low level, white with inlet, ball valve, float and and handle incl brackets, and connections to flush pipes of polythelene of low or high density or PVC 32mm dia for low level cistern complete all as specified and directed by Engr-in-charge.
82S&Fin repair Vitreous China wash down water closet pan ( pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) incl Plastic water closet seat, black, closed patern with flat bottom and cover and mild steel chromium plated or alumined hinging device vitrious Chaina pedestal pattern WC incl PVC seat cover and flush pipe etc complete all as specified and directed by engr-in-charge.
83S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass , mounted on 6mm thick AC building board or commerical plywood and fixed to wodden plugs with chromium plated brass screws and cup washers etc complete all as specified and directed by engr-in-charge.
84S&F in repair Soap dish, any type, fixed to plug with chromium plated brass screws embedded in the wall all as specified and directed by Engr-in-charge.
85S&F in repair 20mm dia brass chromium plated tubular towel rail, D type, 60cm long b/w flanged and directed by Engr-in-charge.
86S&F cast iron floor trap 75mm out let dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)..
87S&F in Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guards and railing 60cm long complete all as specified and directed by Engr In Charge.
88S&F in repair , brass chromium plated , toilet paper holder fixed with chromium plated brass screw, completed all as specified and directed by Engr-in-Charge.
89Supply & fixing in repair 15mm CP mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr In Charge..
90S&F in repair 32mm dia PVC waste pipe for WHB complete all as specified.
91S&F Angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (15mm minimum weight 90 Gms) 15mm dia fixed to iron pipe.
92Supply & fixing Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all as specified and directed by Engr In Charge.
93M & L for Gully traps salt glazed stoneware (SGSW) square or round mouthed type 'P' of size 180x100mm for drain pipes complete all as specified and directed.
94S & F 75 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors
95S & F 110 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors
96S & F 75 mm dia bore PVC (SWR) bends any radius
97S & F 110 mm dia bore PVC (SWR) bends any radius
98S & F 110 mm dia bore PVC (SWR) junction single 'T' equal or unequal
99S & F PVC (SWR) 110 mm bore vent cowl
100M& L for 150mm bore SGSW Pipe including PCC 1:4:8 type D-2, (using 40mm graded stone aggregate) as in bed of drain for 150mm bore pipe incl packing under , and haunching against the sides of the pipes after they are laid in and tested all as directed.
101S&F in 20 mm dia ,Al alloy curtain rails with brackets fixed in repair.
102Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed by Engr-in-Charge
103Taking down unserviceable submain wiring and service cable alongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site.
104Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge
105Matrial & Labour for point wiring using approved colour coding as per IS with using approved coper coding as per IS 1.5 Sqmm multistranded , 1100 volt grade copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceiling including provision PCV Box on top for fixing switches sockets etc. all as specified for one light point / fan / Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
106All as per Srl item No 105 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge.
107All as per Srl item No 105 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the independent board with cable 1.5sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge.
108All as per Srl item No 105 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge.
109Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
110Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one 230 Volt flush type complete all as specified and directed by Engineer -in-Charge.
111Supply and fixing of switch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
112Supply and fixing of Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type single pole one way complete all as specified and directed by Engineer -in-Charge,
113Point wiring complete with 1.5 sqmm single core PVC insulated with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC conduit with all conduit accessories (concealed/surface) casing and capping and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in walls with 3 mm thick bakelite sheet ISI marked top cover with brass screws and cup washers for housing the switches, socket outlets, fan regulators etc for One light / Exhaust Fan point controlled by one switch, all as specified and as directed.
114All as per Item No 113 here-in-before but controlled with one 3 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge.
115All as per Sri Item No 113 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor complete all as per specified and directed by Engineer-in-Charge
116Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete.
117Supply and fix Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
118Supply and fix Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed
119Supply and fix Modular switch 1 way, 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed.
120Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 3 module ISI marked complete all as specified and as directed
121Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 6 module ISI marked complete all as specified and as directed
122Supply and fix MODULAR METAL FLUSH BOX Metal flush box 3 module ISI marked complete all as specified and as directed
123Supply and fix MODULAR METAL FLUSH BOX Metal flush box 6 module ISI marked complete all as specified and as directed
124Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed.
125Supply & Fixing LED light fitting 1 x 9 W / 1 x 10 W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make havells/Bajaj
126M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge.
127Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/leader/havells
128Supply and fix LED 10W Batten white 2 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make- Havells / Philips / Crompton
129Supply and fix in replacement LED Batten 20W , 4 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make- Havells / Philips / Crompton
130Supply and fixing 9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engg-in-Charge. Make: Havells
131Supply and fixing recessed mounting 36 W 3000K 2x2 panel luminaire with high performance LEDs suitable for mounting with Grid ceiling Slim square incl driver complete fitting , all as specified and directed by Engr-in-Charge. Make: Crompton / Havells / Wipro
132Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 8 way 240 volt complete all as specified and directed by Engineer-in-Charge
133Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge
134Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (i) SP 5 to 32 Amp
135Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (ii) SPN 63 to 40 AMP
136S&F exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V,50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as per specified and directed by Engineer-in-Charge.
137Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep heavy duty with, blades, and frame and louvers all as specified and directed by Engr-in-Charge
138Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and directed.
139Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 10 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire ,two single core cable flat or circular ,complete all as specified and directed by Engineer-In-Charge.
140Supply and fixing House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. Grade), with two nos of suitable size of clamp,nuts, bolts and wahers etc fixed to GI sheet roof complete all as specified and directed.
141M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions.
142Excavation in trenches in soft loose soil not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for laying of pipes in trenches and getting out including leveling of bottom surface and trimming of sides after removal of existing pipe of any type and off sizes incl fittings complete all as specified and directed. Note:- Rate for Removal of existing pipe of any type and off sizes incl fittings shall be included in this items.
143Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each excavated soft/hard soil in trenches after the pipes have been laid and tested completed all as specified and directed.
144Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
145Supply, Laying and testing in replacement old UNSV pipe of any type with new 3 layer PP-R,polypropylene random copolymer concealed pipes 25mm outer dia SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fitting laid in trenches, wall, ceilings or in floors etc all as specified and directed.
146Note:- Earth wrck (Excavation, Returning filling and Removal) shall be measured and paid separately.
147Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 25mm dia complete all as specified and directed.
148Material & Labour in replacement of any type and providing aluminium cladding over insulation of PPR pipe of size 25mm dia with aluminium sheet having thickness 0.2mm all as specified and directed.
149Supply and Fix in replacement unsv Gate valves of any type and providing PP-R Gate Valve (brass insert) as per requirement of the site of size 25mm dia bore (outer dia in mm) complete all as specified and directed.
150M & L for Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc. (16 to 40 mm outer dia)
151Schedule of Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57647127
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.96 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Certain Sanctioned Works At Pooh Division Under Area Of Age B/R -I Pooh Of Ge 863 Ews
Basic Detail
Tender No GE/863/EWS-T-82 OF 2026-27
Bidding Type Tender
Location
City Kinnaur
State Himachal Pradesh
Key Dates
Publish Date 22 Sep 2026
Submission Date 12 Oct 2026
Open Date 19 Oct 2026
Finance
Tender Value 29.96 Lakhs
Tender Fee 500
EMD 59920
Exemption Available
Document List
13c2bd68-e839-4e82-9619-9648fcd386b8.html
BOQ_886348.xls
TD82.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Oct 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

13c2bd68-e839-4e82-9619-9648fcd386b8.html

xls

BOQ_886348.xls

pdf

TD82.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender