Tender For Provision Of 3-Phase Power Supply For Lords-N System At Demolition Area Of Nad, Karwar
Tender Value
34.20 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
9 days left
EMD
68400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of 3-Phase Power Supply For Lords-N System At Demolition Area Of Nad, Karwar
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, 3.5 core 240 sq.mm conforming to IS-7098 (Part-I) of 1988 laid in trenches ducts etc complete. |
| 2 | Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft/loose soil all as specified and as directed. |
| 3 | Returning, filling in including levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and as directed. |
| 4 | Disposal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. |
| 5 | Supply of flexible DWC-HDPE pipe (suitable for laying XLPE cables) nominal dia 125 mm, conforming to IS 16205 Part IV under ground and drawing XLPE cable through the pipe including joints, bends etc complete. |
| 6 | M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 240 sq.mm. |
| 7 | M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 240 sq.mm. |
| 8 | Demolition of un-reinforced cement concrete in road and paving's not exc 15 cm thickness (below or above ground level). |
| 9 | M&L for PCC 1:2:4 type B1 (using 40mm graded crushed stone aggregate) as in road filling as specified and directed. |
| 10 | M&L for steel tube, 50mm 'light grade', galvanised, with all fitting, laid under road all as specified and directed. |
| 11 | M&L for LT cable route marker made of heavy duty Cast Iron (CI), 100 mm dia, suitable for underground LT cable identification, including engraving/painting of “LT CABLE”, fixing in position with PCC foundation of nominal mix 1:3:6 (cement:sand:40 mm aggregate), excavation, refilling, curing, complete as required. |
| 12 | Supply, fabricate, install, test and commission floor mounted bus bar junction box made out of CRCA sheet steel of 3.15 mm thick, dust and vermin proof, outdoor type, mounted on PCC plinth with necessary foundation bolts/channel supports, complete with suitable size aluminium bus bars suitable for termination of incoming and outgoing 3.5 core 240 sq.mm XLPE aluminium armoured cables, insulated with heat shrink sleeves and mounted on non-hygroscopic SMC/DMC insulators, including suitable cable alley, detachable gland plate, heavy duty double compression cable glands, aluminium cable lugs, neutral link, earth bar, interconnections, danger notice plate, internal wiring, painting with zinc rich primer and two coats of synthetic enamel paint of approved shade, complete with PCC foundation/plinth, all fixing accessories, terminations, testing and commissioning all as specified and directed by Engineer-in-Charge. |
| 13 | Supply, fabricate, install, testing and commissioning of outdoor LT feeder panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system, out of CRCA sheet of minimum 3.15mm thickness with front and back door access, totally enclosed dust and vermin proof cubicle type to be mounted on PCC plinth, incorporating angle iron frame work of suitable size and providing 150 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate finished even and smooth without using extra cement including complete two coats of zinc rich epoxy primer and two coats of synthetic enamel paint of approved shade over a coat of red oxide primer including complete internal bus bar of aluminium strip 200AMps suitable for load carried and connected load all complete as directed.The panel shall consist of following accessories:-(a) Incoming :-(i) MCCB high breaking capacity 100 Amps 4 pole 415 volt, 36 KA breaking cap adjustable thermal release and magnetic trip – 01 No(ii) Digital multi function meter with suitable capacity of CTs, LED indicator lamp and other connecting accessories(b) Outgoing :-(i) MCCB high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of – 3 Nos(ii) MCB SPN 40 Amps – 3 Nos all as directed by the Engr In Charge.(iii) Internal wiring of panel with stranded copper cable of suitable size(iv) Stencilling of panel board including marking of distributions |
| 14 | M&L for earthing using GI earthing strip 32x6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm medium grade with bends, elbow etc. from earth plate to test point, excavation and earth work in any type of soil, returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick and testing on completion including making test point on wall as per SSR specification all as specified and directed. |
| 15 | M&L for MCCB 4 pole, 415 V of 125 Amps current rating with breaking capacity 36 KA complete with connection testing and commissioning complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysOct 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender