Tender For Special Repairs (B/R) To Qtr No P-40/2 And P-40/4 Of Officers Residential Area At Little Binaga Naval Base Area Karwar.
Tender Value
39.70 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
15 days left
EMD
79400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs (B/R) To Qtr No P-40/2 And P-40/4 Of Officers Residential Area At Little Binaga Naval Base Area Karwar.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of single layer Mangalore pattern roofing tiles, complete all as specified and directed. |
| 2 | S&F rolled mild steel roof trusses (framed), trussed, purlins, rails and fastenings, and heavy brackets framing (beam, tee, angle, channels or flat sections) including distance pieces, cleats, etc., conforming to Fe-290 (Grade E 165). |
| 3 | S&F pre-painted Galvalume aluminium-zinc coating GI based corrugated steel sheet, 0.50 mm thick, of any colour, having tensile strength of 550 MPa, as in roof covering/cladding/ridge to wall, fixed with self-tapping screws, all as specified and directed. |
| 4 | S&F plain galvanised mild steel sheeting, 0.63 mm thick, in ridges, hips, valley gutters, drips and straight flashings (length and girth as fixed) with zinc coating grade 275, complete all as specified and directed. |
| 5 | Dismantling/taking out existing textile coverings including frames (if any) or hessian-based felt or any other existing waterproofing treatment from roof, including cement plaster and exposing the top surface of RCC slab, including removal of dismantled material, complete all as specified and directed. |
| 6 | M&L for applying two coats of SmartCare Damp Proof by roller/brush over a coat of primer, with SmartCare Damp Proof diluted to 33% as per manufacturer’s specification, including preparation of existing surface by complete removal of existing treatment by chipping to remove loose particles and mortar, cleaning with wire brush and water, including filling and coving with SmartCare Repair Mortar (wherever required), filling cracks with SmartCare Crack Filler (wherever required), complete all as per manufacturer’s instructions and as directed by Engineer-in-Charge. |
| 7 | M&L for surface preparation: Preparing the concrete surface by removing dust, dirt, laitance, etc., using mechanical means and treating minor defects with polymer modified mortar using SmartCare Repair Polymer (SBR) all as specified and directed by Engr-in-charge. |
| 8 | Providing and installing SmartCare TPO membrane (reinforced membrane), a high-performance, heat-weldable, scrim-reinforced thermoplastic polyolefin (TPO) sheet, manufactured and supplied in thickness of 1.5 mm as per UNI EN 1849-2, designed for waterproofing and heat shielding of roofs of new and existing buildings. |
| 9 | Notes for Item No.8.00: The membrane shall have:Elongation at break >15% as per UNI EN 12311-2Hydrostatic pressure resistance (6 hrs @ 5 bar) as per UNI EN 1928 Method BTearing strength >300 N as per UNI EN 12310-2Puncture resistance >700 mm as per DIN 16726-5.12Tensile strength >1100 N/5 cm as per UNI EN 12311-2Joints of the membrane shall be welded using a double seam welding machine, and detailing carried out with hand welding tools. The membrane shall be terminated at a minimum height of 300 mm above FFL in vertical areas using termination bars, mechanical fasteners, and PU sealant, complete as per manufacturer’s specifications and product data sheets. |
| 10 | Taking down cement plaster from wall surfaces of any description, including raking out joints, hacking for key, scrubbing with water, etc., complete all as specified and directed. |
| 11 | M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of block masonry or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 12 | M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of concrete surfaces, finished even and smooth without using extra cement and mixed with waterproofing compound as per manufacturer's instructions, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately. |
| 13 | M&L for rendering 5 mm thick in cement mortar (1:3) on ceiling surfaces, complete all as specified and directed. |
| 14 | Supply only integral waterproofing compound. |
| 15 | M&L for two or more coats of distempering on new walls by using mechanical spray (with maximum working pressure of 3300 PSI) with first quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour, complete as per manufacturer’s specifications. |
| 16 | M&L for applying two or more coats of 100% premium acrylic emulsion paint on wall/ceiling using mechanical spray (with maximum working pressure of 3300 PSI) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, with alkali, fungal and dirt resistance (exterior paint) of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm on new surfaces, complete all as specified and directed. |
| 17 | Providing and applying 3mm thick wall care putty over plastered surface on wall to prepare the surface even and smooth, complete all as specified and directed. |
| 18 | Providing and applying 3mm thick wall care putty over plastered surface on ceiling surface to prepare the surface even and smooth, complete all as specified and directed. |
| 19 | M&L for preparation of old painted plastered surfaces of walls/ceiling/chajja of any description, including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts, treating oil and greasy spots, and applying one coat of acrylic emulsion exterior grade weatherproof paint by mechanical spray (with maximum working pressure of 3300 PSI), including necessary scaffolding and safety measures, complete all as specified and directed. |
| 20 | M&L for preparation of old plastered/decorated wall surfaces by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, etc., and applying one coat of oil emulsion distemper by mechanical spray (with maximum working pressure of 3300 PSI), including necessary scaffolding and safety measures, complete all as specified and directed. |
| 21 | M&L for preparation of old plastered/decorated ceiling surfaces by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts, treating oil and greasy spots, etc., and applying one coat of oil emulsion distemper by mechanical spray (with maximum working pressure of 3300 PSI), including necessary scaffolding and safety measures, complete all as specified and directed. |
| 22 | M&L for preparation of old painted wooden surfaces of any description not otherwise described, over 10 cm width or girth, and applying one coat of synthetic enamel paint by mechanical spray (with maximum working pressure of 3300 PSI), complete all as specified and directed. |
| 23 | M&L for preparation of old painted steel surfaces of any description not otherwise described, over 10 cm width or girth, and applying one coat of synthetic enamel paint by mechanical spray (with maximum working pressure of 3300 PSI), complete all as specified and directed. |
| 24 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame), exceeding 1.5 sqm but not exceeding 4 sqm each, including making good disturbed portions to match adjoining surfaces and offering credit as per Schedule of Credit, complete all as specified and directed. |
| 25 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame), not exceeding 1.5 sqm each, including making good disturbed portions to match adjoining surfaces and offering credit as per Schedule of Credit, complete all as specified and directed. |
| 26 | Dismantling boarding of any description, fixed in any position, fixed with screws, complete all as specified and directed. |
| 27 | M&L for 18 mm thick PVC ply, both side plain as in cupboards including solvent cement, stainless steel hinges, handles, SS screws, etc., as per manufacturer’s instructions, complete all as specified and directed. |
| 28 | S&F stainless steel channels, 50 cm to 60 cm long, suitable for sliding drawers complete in repair all as specified and directed. |
| 29 | S&F stainless steel handles, 100mm size for kitchen cabinet/ cupboard shutters complete in repair all as specified and directed. |
| 30 | S&F auto closing hinges 35mm of 0 crank or 8 crank openable at 110 degree for kitchen cabinet shutters. |
| 31 | M&L for solid PVC door frame of size 50 mm × 47 mm made out of 5 mm thick plain colour PVC sheet, reinforced with MS square tube, as per specifications and drawings, complete all as specified and directed. |
| 32 | S&F factory-made solid PVC door shutter, 30 mm thick (stile type), consisting of frame made out of MS tubes for top and bottom rails. The MS frame shall be covered with heat-moulded plain colour PVC “C” channel, having PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top, lock and bottom rails on either side, and as gap insert for top rail ad bottom rail, including paneling of plain colour of PVC sheet fitted in MS frame, welded/sealed to stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as per specifications and drawings. |
| 33 | M&L for second class hardwood plain solid, straight chowkhats and frames, wrought, framed and rebated, rounded or chamfered, put together with glue and pinned at joints, complete all as specified and directed. |
| 34 | M&L for second class hardwood glazed and skeleton shutters, 30 mm thick, open rebated and prepared to receive glass gauge (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, complete all as specified and directed. |
| 35 | M&L for flush shutters, 30 mm thick, solid core construction with particle board core and plywood face panels, both sides laminated with decorative face veneers, including lipping/frame to match, complete all as specified and directed. |
| 36 | M&L for mild steel flat iron holdfasts for securing new wooden frames and similar articles, conforming to Fe-290 Grade E-165, complete all as specified and directed. |
| 37 | M&L for cement concrete block (1:2:4) Type B1 using 20 mm graded stone aggregate in holdfast blocks, including necessary formwork, complete all as specified and directed. |
| 38 | S&F factory-made uPVC white colour three-track, three-panel sliding window with fly-proof stainless steel wire mesh (two glazed panels and one wire mesh panel), up to 1.50 m height, made of big series frame (116 × 45 mm) and sash (46 × 62 mm), both having wall thickness of 2.3 ± 0.2 mm, with single/double glazing bead of appropriate dimension (area of window above 1.75 sqm).Comprising uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanised mild steel section made by roll forming process (shape and size as per uPVC profile), including uPVC glazing beads, interlocks, EPDM gaskets, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (load capacity 40 kg), GI fasteners 100 × 8 mm for fixing frame to finished wall, stainless steel screws, etc.Frame and sash profiles shall be mitre cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage. After fixing, the gap between frame and wall shall be filled with weatherproof silicone sealant over backer rod of required size and approved quality, complete all as specified and directed by Engineer-in-Charge.(Glass and wire mesh shall be measured and paid separately.)Note: For uPVC frame and sash exxtruded profiles, minus 5% tolerance in dimensions (depth & width) is acceptable. Variation in profile deimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 39 | S&F aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples. |
| 40 | M&L for 4 mm thick sheet glass, ordinary quality, and glazing with necessary beading, not exceeding 0.5 sqm in each pane, complete all as specified and directed. |
| 41 | M&L for 4 mm thick figured glass (pin head type) and glazing with necessary fixing arrangements, not exceeding 0.5 sqm in each pane, complete all as specified and directed. |
| 42 | S&F anodised aluminium grill (anodised transparent or dyed to required shade as per IS: 1868 with minimum anodic coating of Grade AC 15) of approved design/pattern, made from approved standard sections, fixed to existing window frame with CP brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to suit opening size for operation of handles and fixing approved anodised aluminium sections around the opening, complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F 100mm medium weight mild steel butt hinges to the frame etc complete all as specified and directed by Engr-In-Charge. |
| 44 | S&F CP mortice lock, 4-lever, vertical type, size 100 mm, with keys in duplicate, complete in repairs all as specified and directed |
| 45 | S&F 200mm long aluminium anodized barrel tower bolts of extruded sections complete all as specified and directed. |
| 46 | S&F 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed by Engr-in-charge. |
| 47 | S&F 150mm extruded aluminium alloy handles, cast type as fixed complete all as specified and directed by Engr-In-charge. |
| 48 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning, refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 49 | M&L for 110 mm dia PVC (SWR) pipe, single socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and directed. |
| 50 | M&L for 75 mm dia PVC (SWR) pipe, single socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and directed. |
| 51 | S&F 75 mm dia PVC (SWR) bend, complete all as specified and directed. |
| 52 | M&L for 75 mm dia PVC (SWR) floor trap, plain with grating, including jointing with solvent cement, complete all as specified and directed. |
| 53 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removing all the rubbish as directed by Engineer-in-Charge complete all as specified and directed. |
| 54 | M&L for providing and injecting chemical emulsion for post-construction anti-termite treatment along external walls below concrete or masonry apron at the rate of 2.25 litres per linear metre, including drilling holes, injecting emulsion and plugging holes with cement mortar to match existing surfaces, complete all as specified and directed. |
| 55 | M&L for providing and injecting chemical emulsion for post-construction anti-termite treatment for soil under existing floors at the rate of 1 litre per hole, at 300 mm centres, including drilling 12 mm dia holes and plugging the holes with cement mortar (1:2) to match existing floors, complete all as specified and directed. |
| 56 | M&L for non-skid ceramic coloured tiles, 7–8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, laid over and including 15 mm thick screed bed in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed. |
| 57 | M&L for glazed ceramic coloured tiles, 300 × 450 × 7 mm thick, in vertical surfaces, laid over and including 10 mm thick cement plaster in cement mortar (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed. |
| 58 | M&L for vitrified ceramic tiles of premium quality, dark shade/double charged, 10 mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 Sq.m (size 600 x 600 mm), laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified. |
| 59 | Material and labour for vitrified coloured tiles of 600x 600 x 10-12 mm thick as in skirting set and jointed in neat cement slurry and pointed in colour cement over 10 mm thick rendering in cement mortar 1:3 including taking down old wall dado/finishes of any description, complete all as specified and directed. |
| 60 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete in repairs all as specified and directed. |
| 61 | S&F stainless steel plate rack of size 0.9 x 0.99 m and thickness 20 guage complete in repairs, all as specified and directed. |
| 62 | S&F counter top wash hand basin coloured oval type 550x445mm of make Parryware model No C0431 popular or equivalent in Cera or Hindware counter type fixed over coloured granite of size 900x600x18mm including rounding of edges, brackets, PVC connection, PVC waste pipe of suitable length, waste coupling (but excl. pillar taps) cutting for and pinning in ends of brackets or erecting slab and fixing of waste pipe etc complete in repair all as specified and directed. |
| 63 | S&F wash hand basin, coloured oval type, size 550 × 400 mm of make Prayag Model No. 4645, including brackets, PVC connections, PVC waste pipe of suitable length, waste coupling (excluding pillar taps), cutting for and pinning in ends of brackets of erecting slab and fixing of waste pipe etc, complete in repair all as specified and directed. |
| 64 | S&F European bristol coupled closet cascade white/ivory colour of size 850x360x720mm with dual flushing cistern of make Jaquar model No OPS-WHT-0205BS with soft close seat cover model No ZPS-WHT-1021UF or equivalent in Parryware or Hindware and connection to drain pipe etc complete in repair all as specified and directed. |
| 65 | S&F wash hand basin mixer, single lever basin mixer with pop-up waste system and 450 mm long braided hoses of make Jaquar Model No. ORM10051B or equivalent in Parryware/Hindware and connected to water connections, complete in repair all as specified and directed. |
| 66 | S&F 900 × 600 mm bevelled edge mirror of selected quality glass, 5.5 mm thick, mounted on wall and fixed with PVC/plastic plugs, chromium plated brass screws and cup washers, including 1st class hard wood decorative beading 70 × 70 mm, complete in repair all as specified and directed. |
| 67 | S&F bib tap, 15 mm bore, cast copper alloy, chromium plated, fancy type, screwed for iron pipe or ferrule with wall flange, complete in repair (Jaquar Cat. No. ORM10037 or equivalent in Prayag/Hindware), all as specified and directed. |
| 68 | S&F bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe, 15 mm bore, complete in repairs all as specified and directed. |
| 69 | S&F angle stop cock, 15 mm bore, cast copper alloy, chromium plated, screwed for iron pipe or ferrule with wall flange, complete in repair of make (Jaquar Cat. No. ORM 10053 or equivalent in Prayag/Hindware), all as specified and directed. |
| 70 | S&F overhead shower rose, brass chromium plated, size 300 × 300 mm, square shape, single flow, with face plate and rubber cleaning system, fixed to 15 mm dia pipe, complete in repair all as specified and directed. |
| 71 | S&F sheet glass shelf assembly (corner type) consisting of 5.5 mm thick sheet glass shelf, 120 mm wide, with CP brass brackets, guard and railing 600 mm long of make (Jaquar Cat. No. ACN 1173 or equivalent), fixed to wall with suitable brass screws, complete all as specified and directed. |
| 72 | S&F stainless steel drapery rod, 20 mm dia, including side caps and brackets, fixed to wall with suitable brass screws, complete in repair all as specified and directed. |
| 73 | S&F towel rack, chromium plated brass, 600 mm long with three lower hooks of make (Jaquar Cat. No. ACN 1181 FN or equivalent), fixed to wall with suitable brass screws, complete in repair all as specified and directed. |
| 74 | S&F chromium plated brass wall mixer, single lever, high flow bath and shower mixer (concealed body), wall mounted with button spout of make (Jaquar Cat. No. ORM 10137 – Ornamix collection, fixed to 15 mm dia pipe, complete in repair all as specified and directed. |
| 75 | S&F chromium plated brass soap dish of make (Jaquar Cat. No. ACN 1131N or equivalent), fixed to wall with suitable brass screws, complete in repair all as specified and directed. |
| 76 | S&F soap dispenser with metallic bottle of make (Jaquar Cat. No. ACN 1137N or equivalent), complete in repair all as specified and directed. |
| 77 | S&F towel rail, 300 mm long for WHB area (Jaquar Cat. No. ACN 1101N or equivalent), complete in repair all as specified and directed. |
| 78 | S&F single lever sink mixer with swinging spout (wall mounted model) with connecting legs and wall flanges (Jaquar Cat. No. ORM 10163 or equivalent), complete in repair all as specified and directed. |
| 79 | S&F health faucet of make (Jaquar Cat. No. ALD CHR 565 or equivalent in Prayag/Hindware), including CP flexible hose 1 m long and wall hook, fixed to 15 mm dia pipe, complete in repair all as specified and directed. |
| 80 | Demolition of cement concrete in ground floors and pavings, not exceeding 15 cm thickness (below or above ground level), for cement concrete un-reinforced complete all as specified and directed. |
| 81 | M&L for cement concrete (1:3:6) Type C2 using 20 mm graded stone aggregate, 75 mm thick, for plinth protection, finished even and fair, complete all as specified and directed. |
| 82 | Demolition of brick/stone masonry built in cement mortar, including quoins, pillars, etc., and removing the debris from the premises complete all as specified and directed. |
| 83 | M&L for precast cement concrete block masonry with solid blocks exceeding 10 cm width, using 20 mm graded aggregate, set in cement mortar (1:6), complete all as specified and directed. |
| 84 | Taking up or down steel tubing and connections, 25 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 85 | Taking up or down GI tubing and connections, 20 mm bore, including cleaning or removal to store, complete all as specified and directed. |
| 86 | S&F 25 mm dia uPVC pipes of pressure rating 10 kgf/cm², fixed complete to walls, ceilings or floors, complete all as specified and directed. |
| 87 | S&F 20 mm dia uPVC pipes of pressure rating 10 kgf/cm², fixed complete to walls, ceilings or floors, complete all as specified and directed. |
| 88 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons, etc., laid and bedded and pointed in any mortar, including removal of rubbish off the site, complete all as specified and directed. |
| 89 | M&L for 20 mm thick granite (any type), black colour (table rubbed and polished), in steps, cooking platforms, etc., set in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite, over and including 20 mm thick cement mortar (1:4), complete all as specified and directed. |
| 90 | M&L for granite work (any type), 12 mm thick (table rubbed and polished), for wall lining (veneering to wall), set in cement mortar (1:3) and pointed with white cement (1:2) using marble dust with admixture of pigment to match shade of granite, including 10 mm thick rendering in cement mortar (1:4) as in backing, complete all as specified and directed. |
| 91 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc., removing materials to store for safe custody or for taking credit (credit for the above items should be made as per conditions separately), and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed by the Engineer-in-Charge. |
| 92 | M&L for point wiring with 1.5 sq mm PVC (FRLS) insulated, unsheathed, multistranded copper conductor cable of 1100 volts grade, single core, conforming to IS 694:1990, including one run of continuous earth wire to common earth and connected to earth with 1.5 sq mm PVC (FRLS) insulated, unsheathed, multistranded copper conductor cable for light point controlled by two-way switch, drawn in PVC conduit, including GI modular sunk boxes for mounting of modular switches, sockets, regulators etc with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 93 | M&L for point wiring with 1.5 sq mm PVC (FRLS) insulated, unsheathed, multistranded copper conductor cable of 1100 volts grade, single core, conforming to IS 694:1990, including one run of continuous earth wire to common earth and connected to earth with 1.5 sq mm PVC (FRLS) insulated, unsheathed, multistranded copper conductor cable for light/fan/bell, drawn in PVC conduit, including GI modular sunk boxes for mounting of modular switches, sockets, regulators etc with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 94 | All as per Item No. 92 above, but for 3-pin switch socket outlet, 5 Amps, on the same board with other switches, complete all as specified and directed by the Engineer-in-Charge. |
| 95 | All as per Item No. 92 above, but for 3-pin switch socket outlet, 5 Amps, on an independent board with other switches, complete all as specified and directed by the Engineer-in-Charge. |
| 96 | All as per Item No. 92 above, but for bell/buzzer point controlled by one push button, on the same board with other switches or on an independent board with cables with other switches, complete all as specified and directed by the Engineer-in-Charge. |
| 97 | M&L for point wiring with 2.5 sq mm PVC (FRLS) insulated, unsheathed, multistranded copper conductor cable of 1100 volts grade, single core, conforming to IS 694:1990, including one run of continuous earth wire to common earth and connected to earth with 2.5 sq mm PVC (FRLS) insulated, unsheathed, multistranded copper conductor cable, drawn in PVC conduit, including GI modular sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 98 | M&L for point wiring with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC conduit including GI modular sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 99 | S&F modular switch, 1-way, 6 Amps, 1 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 100 | S&F modular switch, 2-way, 6 Amps, 1 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 101 | S&F modular socket outlet, 6 Amps, 2/3-pin combined, 2 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 102 | S&F modular switch, 1-way, 16 Amps, 1 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 103 | S&F modular socket outlet, 6/16 Amps, 2/3-pin combined, 2 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 104 | S&F modular bell push, 6 Amps, 1 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 105 | S&F bell, multi-music type, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 106 | S&F modular angle lamp holder, insulated body, with back plate for batten fitting, complete with LED lamp 9 W, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 107 | S&F LED tube light fitting, 1 × 18/20 W, 6500 K, including provision of flexible cable, 3-core, 23/.0076, from ceiling rose to connector, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 108 | S&F LED box type light fittings, 5 W, 1 ft, including making necessary connections, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 109 | S&F LED bulkhead, 10 W, with pressure plastic housing with clear prismatic diffuser, high efficiency LEDs, IP54, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 110 | S&F decorative wall mounting, brushed nickel finish fixture with opal glass diffuser suitable with 9 W LED lamp b22 base complete all as specified and directed by the Engineer-in-Charge. |
| 111 | S&F modular fan step regulator, 120 W, 2 module, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 112 | S&F ceiling rose, surface type, bakelite, 50 × 65 mm, two to three terminals, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 113 | M&L for taking down ceiling fan, removing the old burnt motor and replacing the conventional motor with a BLDC motor suitable for operation with regulator/remote, including electronic circuit, blades, downrod, canopy and all necessary connecting items, complete all as specified and directed by the Engineer-in-Charge. |
| 114 | M&L for taking down and repairing exhaust fans of any make and any sweep, dismantling all parts, cleaning thoroughly, rewinding with super enamelled copper wire of suitable gauge, varnishing, oiling and greasing, replacing petty items such as split pins, assembling and testing after fixing fan blades, refixing at site with required plywood and connecting (steel body) including worn-out/damaged parts such as canopy, rubber bushes, capacitors, gun metal bushes, ball bearings, complete all as specified and directed by the Engineer-in-Charge. |
| 115 | M&L for taking down, repairing, servicing, testing and re-fixing storage type electric water heater (geyser) of any make and capacity 25 litres, including disconnecting electrical connections and inlet/outlet water connections, carefully taking down the unit from it's mounting location, carrying out necessary repairs such as replacement of defective thermostat, heating element, indicator lamp, wiring, terminal block, safety valve, gaskets or other minor components (excluding cost of major replacement parts unless separately measured), cleaning internal scale deposits, reassembling, refixing in original position, reconnecting all electrical and plumbing connections, testing for proper operation, leakage and safety in all respects, complete all as specified and directed by the Engineer-in-Charge. |
| 116 | S&F ventilator fan, AC single phase, 230 V, size 150 mm (PVC body) with louver shutter (white/ivory), connected with flexible cord of size 23/0/0076, stranded copper conductor, PVC insulated, of length not less than 0.7 m, complete all as specified and directed by the Engineer-in-Charge. |
| 117 | M&L for taking down sub-main wiring of size 2.5 sq mm to 6 sq mm of 3 runs, removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made separately as per conditions), and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed by the Engineer-in-Charge. |
| 118 | M&L for sub-main wiring with two single-core PVC insulated, FRLS, unsheathed, multistranded copper conductor cables of size 6 sq mm (nominal area) conforming to IS 694:1990 in existing conduit, and continuous PVC insulated single-core copper conductor stranded unsheathed 6 sq mm, as earth wire, complete all as specified and directed by the Engineer-in-Charge.(Note: Two single-core cables and one earth wire shall be measured together as one length.) including making good disturbed surfaces. |
| 119 | M&L for sub-main wiring with two single-core PVC insulated, FRLS, unsheathed, multistranded copper conductor cables of size 2.5 sq mm (nominal area) conforming to IS 694:1990 in existing conduit,and continuous PVC insulated single-core copper conductor, 2.5 sq mm, as earth wire, complete all as specified and directed by the Engineer-in-Charge.(Note: Two single-core cables and one No earth wire shall be measured together as one length.) including making good disturbed surfaces. |
| 120 | S&F MCB protected socket outlet, PVC plastic base model (white), complete with one single-pole MCB, 20 Amps, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 121 | S&F sheet metal enclosure, powder-coated DB, for fixing of MCBs, TPN, 6-way, double door, IP-42 protection, with 200 Amps rated busbar, 415 Volts, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 122 | S&F MCB, SPN, 40 Amps, 240 Volts, 10 kA, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 123 | S&F MCB, SP, 6–32 Amps, 240 Volts, 10 kA, complete in repairs all as specified and directed by the Engineer-in-Charge. |
| 124 | S&F decorative modular DP switch, 32 Amps, 2 module, one-way, flush type, complete in repairs all as specified and directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender