Tender For Provn Of Two Ac Storage Sheds At Bharatpur
Tender Value
20 Crore
Estimated cost
Bid Submission
27 Oct 2026
23 days left
EMD
13.25 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Two Ac Storage Sheds At Bharatpur
BOQ
| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 2 | Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"AREA DRAINAGE \\" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"LIGHTENING PROTECTION\\" as listed in Schedule ‘A’ Part-VII\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 10 | Lump sum price worked out by the contractor for \\" SUMMER APPLIANCES \\" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 11 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 12 | Sch 'A' Part-XII MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 13 | INTERNAL ELECTRIFICATIONSupply and fixing flameproof LED light fixture/ fitting CIMFRM certified 50W Sunflower LED complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat Part No PEC/LED/2003 of Pluto Flame proof Controls or equivalent model of flexpro/Crompton Greaves/ Phillips as approved by GE complete all as specified and directed. |
| 14 | Supply and fixing LED flameproof tube light fitting CIMFRM certified 1x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat Part No PFC/LED/1036 of Pluto Flame proof Controls or equivalent model as approved by GE complete all as specified and directed. |
| 15 | Supply and fixing t of LED flameproof tube light fitting CMRI certified 2x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat Part No SSPL/FF/1271 of Pluto Flameproof Controls or equivalent model as approved by GE complete all as specified and directed. |
| 16 | Supply and fix flame proof and weather proof industrial type 4 way TPN DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB TPN 60 Amps, C type (incoming) (b) 08 Nos MCB SP 6-32 Amps C type (c) 1 Nos MCB SPN 40-63 Amps C type including necessary connection complete all as specified and directed by Engr-in-Charge. Cat Part No PFC/IB/1030 or equivalent model. |
| 17 | Supply and fix flame proof and weather proof industrial type 8 Way SPN DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB SPN 32 Amps, C type (incoming) (b) 06 Nos MCB SP 6-32 Amps C type including necessary connection complete all as specified and directed by Engg-in-Charge. Cat Part No PFC/IB/11 or equivalent model |
| 18 | Supply and fix flame proof and weather proof industrial type 3 way Junction Box 100mm dia Cat Part No PFC/SS/10 of Pluto Flameproof Controls or equivalent model of flexpro/Crompton Greaves/Phillips as approved by GE including necessary connection complete all as specified and directed by Engg-in-Charge. |
| 19 | Supply and fixing LED mirror light fitting with high out put with low energy consumption of capacity 6 watt,waterproof moisture anti-fog anti-corrosion anti-rust,curved LED off-white including connecting up with three core flexible copper conductor cable of suitable size complete |
| 20 | Supply and fixing sensor based 20 watt LED tubelight fitting batten type 4 X feet long with rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed. |
| 21 | S& F surface mounted LED luminiare, 20 watt, 4 Feet with all accessories having aluminum extruded channel with diffuser for glare free light, high lumen output, driver PF >0.90 having over voltage protection upto 400 volts and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. |
| 22 | S & F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for \\"B-22 type to fix on batten holder complete all as specified and directed. |
| 23 | SEWAGE DISPOSAL Supply and fixing of LLDPE septic tank with upflow filter including media for 10 users designed to carry sewage and sullage water , excavation in any type of soil, PCC 1 :4:8 below foundation,vent shaft, connection pipe for inlet and outlet of any dia etc as per manufacturer instruction completed all as per specified & directed. |
| 24 | Provn of Sokage well, excavation in ordinary soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-25 concrete, including intercepting chamber, screen chamber brick work in CM 1:6, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 meter dia and 3.00 meter effective depth, complete all as specified and directed |
| 25 | EXTERNAL WATER SUPPLY Boring/Drilling Trial bore holes of 200 diameter bore in all kinds of soils, unconsolidated & semi-consolidated formations and rocks by using suitable method (by DTH-cum-rotary or riverse rig method or auguring by hammering) or any other suitable drilling method upto 200 mtr depth below ground level in any type of soil rock/ hard rock / loose boulders with sand including collection of strata samples in transperent polybegs @2m or whenever there is any change in strata, selection of site for boring by standard method/ practice disposal of materials obtained ( soil, rock, boulders, etc) from boring to distance not exceeding 50 meter including complete in all respects with all labour, materials, tools and tackles, equipments, rig, etc. all as specified in IS 2800 and direction of the Engr in charge'.Note: If there is no water output after boring of trial bore, the contractor shall be carried out another boring at the place all as directed by Engr-in-charge. The additional boring shall be measured and paid in this item. |
| 26 | Devolopment of borewell by Reaming of borewell from 200mm to 300mm drilling by direct rotary fast rig method or any approved method at site below ground level in any kind of soil strata incl hard stone/boulder complete all as specified in IS 2800 and directed by the Engineer in Charge. |
| 27 | Development of bore wells indulding flushingout tree roots, silt, fine sand by air compressor of suitable capacity not less than 450 CFM at 150 PSI & over pumping (25% extra capacity pump) 12 hours continuously to make water free from trublidity till clear water is obtained from bore well complete all as specified and directed |
| 28 | Yield test of borewell after completion of development of bore well by V notch method or any method of compresser or by pumping as required complete all as per IS and as directed.Note: Necesssary equipment such as collection V notch water collection Tank, temporary motor pump set of capacity 1x 10 HP , temp HDPE column pipe,etc for testing for yield test are arrange by the contractor. The cost of the same is deemed to be included with unit rate of item. |
| 29 | Supplying and lowering in the bore hole, the plain assembly MS casing pipe Fe 410 and Fe 450 grade steel as per IS-4270 and nominal bore of pipe 200mm and wall thickness of 5.4 mm including welding of pipe at site with two coats of approved anti-corrosive paint on outer faces of the pipe and specials including supply of all labour, equipments and materials complete as per specifications and instructions of ENGR-IN-CHARGE. |
| 30 | Supplying and lowering in the bore hole 200 mm, 5.4mm thick MS casing slotted pipe with all necessary fittings and painting of pipe with two coats of anti corrosive approved paint on outside surface of pipe before lowering including supplying all labour, equipments and materials complete as per IS, specifications and instructions of ENGR-IN-CHARGE. |
| 31 | Supply fixing and lowering MS bail plug and well cap suitable for 200 mm bore plain pipe thickness 5.4 mm complete with welding and painting of pipes all as specified & directed |
| 32 | Supply and erection of housing clamp fabricated out of MS flat iron bent to shape 50 mm x 8 mm thick including nuts, bolts and washers as per IS-2800. |
| 33 | Supply of pea gravel size ranging from 12mm to 8 mm. All gravel shall consist of hard well rounded particles reasonably uniform with uniformity coefficient of less than 2 including packing in the annular space between casing pipe & drilled bore as per the direction of ENGR-IN-CHARGE.& as specified, complete. |
| 34 | Supply, erection, testing and commissioning of Submersible pump and motor as per IS-9283 (latest) for a pumping capacity 7.5 HP with180mtr head & discharge capacity of 180 LPM suitable for 50mm dia delivery column pipe complete all as specified and directed by Engineer-in-charge. |
| 35 | S&F submersible cable weather proof with multi-stranded copper conductor 3 core of size 6 sqmm 1100 volts grade heavy duty including all accessories for connection pump from panel board, testing and commissioning complete all as specified and as directed. |
| 36 | S&F of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia(multi wire stainless steel) for holding of submersible pump motor set all as directed by Engineer-in-Charge. |
| 37 | Supply installation testing and commissioning of LT panel board outdoor cubical type IP55 protection, vermin and dust proof factory made of CRCA sheet 3.15mm thick back door detachable type fixed with nuts and bolts and front door fixed with hinges and knobs, powder coated for 3 Phase 415 volts, 50 Hz, AC supply complete all as specified and directed by Engr in Charge and comprising of the following:-a)Aluminium Strip Bus bar fixed on epoxy insulators capacity 100 Amp and bakelite insulation sheet at the back with coloured tape - 01 Set(3 phases and one neutral)b) Incoming MCCB TPN 63 Amp16KA capacity - 01 No.c)Outgoing MCB TP 40 Amp16 KA capacity - 02 No.d) Electronic Digital type Ammeter flush type 0-100Amp with selector switch and CTs. - 01 No.e) Electronic Digital type Voltmeter flush type 0-500V with Selector Switch - 01No.f) Set of indicator lamp RYB - 01 Setg) FASD Motor Starter with MPCB and single phase prevention suitable for 7.5 HP pump - 01 No.h) Complete internal wiring with suitable size copper conductor including cable lugs,glands etc.j) Masonary and concrete work for foundation of panel including MS frame for mounting of panel well above the ground level - 1 jobNote: Drawing and make of LT panel and connected items to be approved by GE before placing the order. |
| 38 | Supply and laying of GI pipe heavy class 3 mtr large in flange joint after 3 mtr complete with rubber gasket, nuts, bolts, washer for column pipe to bore well of size 50 mm dia including necessary arrangements for coupling arrangement on top and bottom ofv GI pipe heavy class with pump and delivery pipe complete all as specified and directed. |
| 39 | Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,100 mm (4”) dia all as specified and directed |
| 40 | Supply and fixing of pressure guage, 100mm size fitted on delivery side of pump set(0 to 10.6 kg/sqcm) complete with needle valve etc all as speified and directed. |
| 41 | Carry out Resistivity test by the team of Central ground water board/State ground water dept. for define of water aquifier at 01 location in Depot area incluiding test report complete all as spicified and directed |
| 42 | M & L Pit masonary for valves and meters constructed complete with MS sheet cover and locking arrangement etc suitable up to 100 mm dia of size 900 x 900 X 900 mm |
| 43 | Supply, install and commissioning of direct online starter of capacity 01 HP motor provided with protection degreee IP 54 with FRLS internal wiring with 01 HP Motor for plant complete all as specified and directed. |
| 44 | Supply and fixing PVC 3 Layered tanks of capacity 10,000 Ltrs ISI marked on PCC (1: 3:6) using 20mm graded stone aggregate staging for make up water requirement inclduing brass float valves with polythene ball, overflow and drain arrangement complete all as specified and directed. |
| 45 | SUMMER APPLIANCESSupply and install testing & commissioning voltage stabilizer for automatic operation, single phase naturally air colled Indoor type copper wound & designed for input variation between 170V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and directed. |
| 46 | Supply, fixing and fabrication and testing desert cooler in PVC body sheet with and including cooler fan motor size/sweep 450mm (fan blade only) 230 Volts, Single phase 50 Hz, 1400 RPM, heavy duty single sheet, totally enclosed. The overall dimesnions of the desert cooler shall not be less than 690mmx690mm x 1020mm with and including following accessories each. |
| 47 | FLAME PROOF CRANE:Design, supply, Installation , testing and commissioning of Flameproof (FLP), electrically operated, overhead travelling (EOT) cranes of 5 Ton Capacity suitable for operation inside AC Shed containing explosives having UN Hazard classification as 1.1 and having slight quantum of generation of explosive vapours/ dust, as per gas group I, IIA & IIB as per IS: 2148-2004, Soft start and soft stop, conforming to IS : 3177 (latest revision), Suitable for operation on 415 Volts, 3 phase, 4 wires, 50 HZ supply, Double girder type, with necessary steel supporting structures, with hoisting, Cross Travel (CT), and Long Travel (LT) with separate variable voltage variable frequency (VVVF) drives of suitable capacities with separate flame proof enclosures for each drive, conforming to IP 65 and CIMFR duly certified for all motion. The soundness of makes as approved and should be certified by CIMFR (Central Institute of Mining and Fuel Research ) Dhanbad or Govt approved body, with control panel, power and controlling cables, confirming to relevant IS controlled by Pendant control which shall be movable type along the crane, with creep speed @10% (Ten percent) for main hoisting LT & CT motions, no auxillary hoist , and facility for mechanical lowering only at very slow speed, in case of power failure when a container is hanging on hook, with provision of cover lock with crane hook, provisions so that, in case of power failure the crane should lock in its current position, and also including the followings :- |
| 48 | Item 47.00 Contd/...(i) Girders : Fabricated using fresh tested steel plates to IS 2062 Gr 'A' obtained directly from Main Steel producers, cut to size using the latest CNC profile cutting machines and welded using modern welding practices. All welds shall be subjected to radiography to ensure defect free welds.(ii) Hoisting Mechanism : With specially designed crab unit for Double girder, engineered for smooth, jerk free, and soft start, lifting of loads, Hoist drive with variable voltage frequency drive (VVVF), selected according to the class of duty, driving the rope drum, througn helical gear box,. The rope drum shall be made out of seamless pipes fabricated from plates tested as per ASTM/IS standards. All electrical equipments shall be housed in Flame Proof (minimum ingress Protection IP 65) enclosure)(iii) Gear Boxes : With helical gears, oil lubricated, manufactured using the modern gear cutting machines, duly heat treated to withstand the tringent load conditions and selected according to class of duty commensurate with type of application.(iv) End carriages : : With standard wheel bases suitable for TE cranes fabricated using the modern welding and machining techniques to ensure jerk free and smooth travel motion. The wheels shall be double flanged, supported on self aligning anti-friction bearing, Buffers shall be provided at the ends of the carriage as per IS standards.(v) Brakes : For all drives shall be AC Electro-hydaraullic thruster crane duty brakes shall be crane duty. |
| 49 | Item 47.00 Contd/...(vi) Hooks : Shall be shank type supported on antifriction thrust bearing and the sleeve pulleys shall be made out of malleable cast iron or fabricated, conforming to IS: 3815vii)Controls : The Crane shall be controlled by pendant, the main electrical components shall be housed in Flameproof (Minimum ingress protection IP : 65) enclosures, conveniently located for easy maintenance. Standard protection shall be provided. (viii)Gantry Rails : As per contractors own desing shall be provided.(ix) Down shop leads (DSL) : DSL with flexible cable system with suitable cable tray shall be provided.(x) Buffers : Buffers on end carriage shall be rubber type(xi) Limit Switch : (a) Main Switch: Geared Rotary + Gravity. (b) LT & CT : Lever Type for the following (a) Five (5.0) tons capacity, Electric Operated Approximately 36 mtr longitudinal travel and 18 mtr Span, Approximately 4.5 mtr hook height to be installed in each of 02 x AC Shed at BharatpurNote :- (i) Cost of I Gantry Girder and it fixing on RCC Bracket shall be included in the cost of crane, However, fixing arrangement for girder in RCC Bracket as shown on drawing shall be included in the cost of building.(ii) This same shall be installed in each AC Shed Building (02 Nos). (iii) Dimensions, Spans length of travel to got verified with deuilding design drwaings/ at site before making crane drawings/placing order for EOT Crane. |
| 50 | Item 47.00 Contd/...(iv) The deisgn and drawing of EOT Cranes hall got approved by GE before manufacturing of EOT Crane. (v) The structural steel to be used for manufacturing shall be from prime producer of steel |
| 51 | AIR CONDITIONING PLANT:Design,supply, installation, testing and commissioning of high efficiency central Chilled water type air conditioning plant of water cooled chiller package type with minimum capacity of 150 TR and 75 TR standby (3 units of 75 TR each 2 Units running at a time and one as standby ) comprising of water cooled chillers with scroll compressor working on R-134A / R-410A / R- 407C refrigerant (Green gas), chiller, condenser,chilled water circulation system,condenser water circulation system, refrigerent piping, control valves, cooling tower, air handling units,supply and return air duct, electrical controls& protective systems,winter heating, dust control, humidity control equipments to operate wth 415V, 50Hz, 3phase AC supply. complete for new 02 X AC Storage Shed at FAD Bharatpur for maintaining inside condition air temperature 20 +/-5 degree Centigrade and RH 55 +/-5%, dust control 10 Micron,with air changes 2 per Hr.Design conditions required as per User Data sheet: Temperature : 20 +/- 5 degree CentigradeRelative Humidity: 55+/- 5%Equipment load : 10KWNo of air changes: Two per hour.Production of gas : NilAcceptance of noise level : NormalWorking hours of equipmet: 24 Hrs |
| 52 | Item 48.00 Contd/...(a). SPECIFICATIONS FOR SCROLL CHILLER PACKAGE UNITS:-Each chiller package shall be factory built and tested, It shall consists of scroll compressors – motor units of total 75 TR capacity capable of controlling capacity from 25 % to 100%. Water cooled condenser MS shell and copper tube type with openable end plates, Safety Relief valve & Purge Valve etc. chiller with MS shell removable end plates, chiller shall be insulated with 19mm nitrile rubber insulation, segmental baffles and copper tubes , expansion valves as per compressor capacity, copper refrigerant piping and fittings, refrigerant feeding devices, valves, strainer, liquid moisture indicator,integral oil seperator, suction line insulation , first charge of oil and gas, starter panel etc. all the components shall be mounted on a rigid welded steel base frame shall be protected with primary coating. The base frame shall incorporate suitable provisions for the rigging and handling of the machine during erection. Chillers shall be suitable for indoor installation. The panel shall contain motor starter and shall be suitable for single source power supply. It shall incorporate main disconnect MCCBs/MCBs for individual motors, contractors, over load relays, single phase preventers, under /over voltage trip, on / off push buttons, Unit should be BMS compatible facilitated for automatic operation and option for manual and facility for remote starting & stopping of chiller packages, auxiliary contractors, temperature and current sensors in each phase to protect motor, control cabling from panel to compressors, pumps,CT,AHU, etc. |
| 53 | Item 48.00 Contd/...The control panel shall incorporate an easy-to-use operator interface panel and Shall display all operating and safety codes.(b). SPECIFICATION FOR CHILLED AND CONDENSER WATER CIRCULATION SYSTEM:-(i). Chilled water pump 2 Nos (1W+1 S/B) of Energy efficient centrifugal backpullout electric driven pump sets of suitable capacity heavy duty high efficiency complete with bronze impeller antiviberation arrangements gland drain connections with base frame complete with all accessaries as per OEM for recirculation of chilled water 3 Phase, 415V,50 Hz AC supply as specified(ii). Condenser water pump 2 Nos (1W+1 S/B) of Energy efficient centrifugal backpullout electric driven pump sets of suitable capacity heavy duty high efficiency complete with bronze impeller antiviberation arrangements gland drain connections complete with all accessaries as per OEM for recirculation of cooling water 3 Phase, 415V,50 Hz AC supply as specified(iii). Heavy duty butter fly valves( flanged type) , non return valve, y stainer ,Balancing valves,Rubber expansion joints,Flow switch, pressure gauges, temperature gauges at both suction and discharge for each pump including rubber vibration isolation pads mounted on ISMC frame as per the manufacturer on PCC foundation including all connections all as specified.(iv). Condenser water piping of MS Class 'B', pipe, welding and fitting of suitable size as per recommendation of manufacturer with non chemical type online water scale preventor of suitable size for interconnecting the cooling tower with condensers and pump, |
| 54 | Item 48.00 Contd/...make up water tank PVC ISI marked not less than 2x 10000Ltr cap. drain pipe, complete with all necessary fittings(v). Chilled water piping with MS \\"C\\"class ERW pipe of suitable diameter including all weldable fittings, butterfly valve, NRV for interconnection between water chiller, chilled water pumps with AHUs., make up chilled water tank, Chilled water piping shall be insulated 50mm thickness and density not less trhan 20 kg/cum th layer of 120 gm/sqm polythene sheet (as vapour barrier) duly reinforced with 26 gauge chicken wire mesh with buffing of all joints and tied down with GI lacing wire and finally finished rigid with 26 guage aluminium foil cladding if laid inside the building, and with cement mortar of 1:3 of 12mm thick if laid in ground or air outside the building complete (vi). 02 Nos of FRP induced draft counter flow cooling tower circular type suitable for not less than 100TR each Cap .Structure should be honey comb (pvc) fill. Fan - Axial flow direct driven fan,Non corrosive. Motor -TEFC,IP-55 suitable for 3P / 50Hz / 415V (Technical Specifications as per the manufacturer) including necessary PCC foundation, along with mechanical structure for the base of cooling tower, PVC makeup water tank of minimum 2 x 10000Ltrs capacity ISI mark with brass float valve,overflow and drain arrangement with suitable PCC/Brick staging water connection to the tank and from tank to cooling tower incl suitable size of ladder, electric connection from panel to cooling tower, etc . Minimum two meter all around area of cooling tower and makeup water tank will be PCC with drain arrangement. |
| 55 | Item 48.00 Contd/...vii) Water softening plant of min 20,000 LPH :- Supply, install testing of water softening plant made of MS Sheet of suitable capacity for desinged hardness 500PPM, product hardness 50 PPM & capacity 20 m3/Hr comprising of the water softner, Feed Pump, Sump for treated, pumpset for water transfer complete all as specified and directed.(c) DE HUMIDIFIER: De humidifier shall be pan type fabricated out of 2mm thick galvanised MS sheet having connection of quick fill make up, over flow and drain including provision of sight glass, flood light to visibility of water and the top of the channber covered with openable perforated stainless steel cover, The body of humidifier shall be air-tight and leak proof duly insulated with fiber glass 32 KG/Sqcm, 50mm thick and then claded with 0.8mm thick aluminium sheet including one bank of heater of 0.5 Kw to maintain temperature of water 60 C -70 C and electrical control panel made of 16 gauge CRCA sheet powder coated provided with connectors, MCB,low level cut out heating thermostat, fault indiacting lamp high temperature cut out, float switch with copper ball heater and internally wired with humidistat complete-01 No(i) Electric Hot water generator comprising following :- |
| 56 | Item 48.00 Contd/...(ii) Electric Hot water generator vertical type of suitabal capacity conforiming to ASME boiler and pressure code complete with heater banks with mild steel body 10mm shell 12mm dish head top openable with thick MS flat and sufficient Nos of nut bolts, flange etc compolete with fiber glases 50mm thick insulation covered with aluminium foil of size 20 gauge all around with electrical control panel, wiring and control and safety devices temp and pressure gauges, thermo couple temp control and butter fly valve etc for reheat and winter heating.(iii) Hot water pump mono block type duly coupled wth SPDP squirrel cage induction motor complet with pressure gauge with suitbale needle valves, butter fly valves on suciton and delivery lines, suction guide with strainer , check valves on delivery lines etc and other accessories including foundation of suitbale capacity inclindg base frame as per maunfacturers instrutions wiht suitbale starter operation form main control panel-02 Nos (One as standby ) |
| 57 | Item 48.00 Contd/...(iv) Supply and fixing mild steel 'C' class hot water pipe line one lot for recirculation of hot water complete with necessary fittings such as butterfly valves, balancing valves, at inlet and outlet connections form hot water generator to pumps, pumps to AHU, AHU to hot water gernator along with insulation of fiber glass 50mm thick insulation covred with alumiuum foil of size 26 guage all arround including water pressure gauge, thermometer at hot water genrator inlet and outlet, AHU inlet and outlet conneciton complete with all accessoreies.(d) . SPECIFICATION FOR AIR HANDLING UNIT AND AIR DUCTS:(i) Two Nos Double skinned construction Air Handling Units (AHU) suitable for chilled water system of minimum capacity 30000 CFM each made out of GI sheets, frame viberation pads,chilled water in lets/out lets connctions, controls, horizandal axil flow bowers, chiled water cooling coil with associated controls, filter section with 10 micron HDPE woven meshfilter in aluminium frams etc all as per the site rquirement and all as per the design parameters and as specified, volume control damper, Energy Efficient Flameproof Motor (IE2 Series) (IP-55) with class F insulation of suitable capacity and specified makes,The fan section should be mounted on anti vibration pads and free from main structure and comprising of the following :-(i) 6 rows Cooling coil of copper tube with aluminium fins automatic controlled anti-freeze thermostat suitable for chilled water.(ii)Two rows humidity/hot water coil section. |
| 58 | Item 48.00 Contd/...(iii). GI Ducting with necessary insulation with collers, brackets, MS suports,for supply/ return air ducts fixed as per design for 02 X AC Pland & Sheds from AHU with necessary jet type(eye ball type) adjustable difussers, return air grills, fresh air grills,dampers, plinum etc as per the design. All duct work shall be independently supported from building construction.All supply and return air ducts at AHU room shall be provided with approved make motorised fire dampers of at least 2.0 hour fire rating.(iv) External thermal insulation on supply/return air ducts laid inside the conditioned room with aluminium foil faced Nitrile rubber of fire redardant class 'O' type 12mm thick for supply ducts and 9mm thick for return ducts.(v) Acoustic lining to the main supply air duct from AHU up to a minimum length of 6 mtrs with 25mm thick of Resin bonded glass wool of density 32 K/cum overlapped with RO tissue, sealing all joints and finally covered with 0.5mm perforated aluminium sheet.(vi) External thermal insulation to supply and retrun air duct laid outside the conditioned space/ room with 50mm thick expanded polystyrene slab (TF quality) of 24 Kg/cum density pasted with hot bitumen after one coat of black paint over duct surface, vapour barrier of 120 gm/sqm polystyrene sheet and finally finished with 26 guage aluminium tape complete to make it weather it weather proof all as specified in particular specification. |
| 59 | Item 48.00 Contd/...(vii) One Nos electronic digital temperature and RH display board fixed in AC Plant room and sensors installed inside the 02 x AC Sheds for measure air temperature and RH with necessary switching arrangement.(e) . SPECIFICATION FOR MAIN CONTROL LT PANELCubical type vermin proof, dust proof, IP-54 factory made by manufactures having type test report of CPRI floor mounted main LT eletric panel totally enclosed with separate chambers for bus bars, cable entry, exist and meters for housing voltmeter/ammeters/KWH meters selector switch/indicator lamp etc suitable for 3 phase, 415 volt, 50 Hz of 35 MVA rupturing capacity and having anodised copper bus bars (4 Nos of suitable rating) fabricated from 2mm thick CRCA sheet powder coated through seven tank process facility for pairinng and degreasing duly inter connected with all allied accessories as requried complete with following mountings.(i) Necessary electric control wiring for running the plant including inter connection and inter locking wiring as per specification by PVC multi core 1.5mm stranded copper control cable.(ii) Status indication (ON/OFF) of each compressors, pumps, AHU, cooling tower motor, hot water generator, humidifier, dampers and other essential electrical components.(iii) Main incoming MCCB of suitable capacity 4 pole if 35 KA (ICS-100% ICU) rupturing capacity with adjustable type microprocessor release type for short circuting,O/C and E/F. |
| 60 | Item 48.00 Contd/...(iv) Outing MCCB with rupturing capacity 25KA :- 04 Nos of suitable capacity (i.e. 03 Nos for scroll chilling unit and 01 No. spare), 02 Nos MCCB of suitable capacity i.e. 01 No for Hot water generator and 01 No spare and 02 Nos MCCB of suitable capacity for AHU motor, 03 Nos MCCB for chilled water pumps and 03 Nos MCCB for condenser pump and 01 MCCB for cooling tower, 02 Nos of MCCB for hot water pumps and one No MCCB of suitable capacity for APFC panel & 01 Nos of MCCB 63A for Building lighting. Note:- Connection of all the MCCB's are to be done with Multistrandred single core copper cable of size not less than 25 Sqmm with copper lugs.(v) One digital tamper proof energy meter (KWH) and one set of LED type indication lamps, digital voltmeter with inbuilt selector switches, individual digital ammeters with suitable CTs with inbuilt selector switches for all motors contactor of suitable capacity for starting/stopping motors, overload relays, single phase preventer for all motors with trip button and toggle switch wherever required.(vi) Fully automatic star delta starters for motor of capacity above 5 HP and DOL starters for motors of capacity 5 HP and below for condenser pumps, chiller pumps, AHU blower motor, and cooling tower fan with necessary interlocking for safe operation of AC plant.(vii) Space for starters e.g Chiller Water pumps- 02 Nos, Condersor Water pumps- 02 Nos, Hot Water pumps- 02 Nos, Chiller units- 02 Nos, Cooling tower- 01 No and AHU motors- 02 Nos |
| 61 | Item 48.00 Contd/...(viii) Two nos electronic digital thermometer one at plant room and another a Auditorium main hall to display their return air temperature with necessary switching arrangement.(ix) Power cabling of adequate size, rating and sufficient core from LT panel board to electric motors and other electrical equipment viz 02 Nos Scroll chilling Unit, 02 Nos condensor pumps, 02 Nos chilled water pumps, 01 No cooling tower motor, 01 No Hot water generator, 02 Nos Hot water pumps, 02 Nos AHU motor, 01 No APFC panel and other allied electrical equipment if any with multistranded copper conductor armoured cable laid neatly and in straight line in trenches/wall/ cable trays with necessary sadless and clamps including copper lugs of suitable size and cable glands etc all as specified and as per IE rules and electridcal codes. |
| 62 | Item 48.00 Contd/...(x) M&L earthing complete with Galvanized steel earth plate 600x600x6.0 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI strip of size 25x3 mm for motor of capacity more than 10 HP and GI wire 4mm dia for less than 10 HP motor/ LT panel as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel including excavation and earth work, GI pipe light grade 25mm/40mm bore for protection of GI wire/strip from earth electrode to and including the earth test point of galvanized iron/steel of size 75x75x25cm supplying and laying charcol dust, common salt,PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick 1:2:4 type B1 (using 20mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @ 75mm c/c both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part-I of 2009 and connected to earth test point incl testing complete all as specified and directed-19 Nos as follows. (Chillers- 4B, LT panel 2B, APFC - 2B, Hot WG - 2B, CWP- 2, Cooling Tower- 1, AHU-2) (Note:- Earthing to all equipments shall be provided as per IE Rules) |
| 63 | Item 48.00 Contd/...(f) Specifications for APFC PANEL : Supply, install, testing and commissioning of 100 KVAR capacity automatic power factor corrector capacitor panel (APFC) of ready to use design conforming to IS- 8623 and suitable for 415 volts, 3 phase, 50 Hz and housed in elegant and highly functional enclosures of modular design fabricated from 2mm thick CRCA sheet duly powder coated and comprises of following to maintain PF automatically of not less than 0.95 with necessary capacitive duty contactors, auxiliary contactors, ON/OFF indication lamps for each capacitor, start/stop switc for each capacitor, having manual start/ stop features in addition to automatic ON/OFF for each capacitor with anodised copper bus bar, internal wiring, relays etc :-(i) A set of heavy duty capacitor (5x10 KVAR + 10x5 KVAR) type MPP manufactured by using metalized poly propylene techonology having total losses < 0.5 W/KVAR high overload and frequent switching capacity conforming to IS: 283, IS: 13340 and IS 13341 fitted with special sequential pressure sensitive disconnector.(ii) A set of capacitive duty contactor and realy of suitable ratings of 3 phase, 415 V.(iii) Incoming MCCB suitable for 100KVAR to ensure positive isolation of capacitors from both sides when the unit is off including quick make and break type with replaceable contacts conforming to 1100 volt grade with cable entry from bottom.(iv) Ammeter with CT, Voltmeter, power factor meter RYB indication, selector switch. Please Enable Macros to View BoQ information |
| 64 | Item 48.00 Contd/...(f) Specifications for APFC PANEL : Supply, install, testing and commissioning of 100 KVAR capacity automatic power factor corrector capacitor panel (APFC) of ready to use design conforming to IS- 8623 and suitable for 415 volts, 3 phase, 50 Hz and housed in elegant and highly functional enclosures of modular design fabricated from 2mm thick CRCA sheet duly powder coated and comprises of following to maintain PF automatically of not less than 0.95 with necessary capacitive duty contactors, auxiliary contactors, ON/OFF indication lamps for each capacitor, start/stop switc for each capacitor, having manual start/ stop features in addition to automatic ON/OFF for each capacitor with anodised copper bus bar, internal wiring, relays etc :-(i) A set of heavy duty capacitor (5x10 KVAR + 10x5 KVAR) type MPP manufactured by using metalized poly propylene techonology having total losses < 0.5 W/KVAR high overload and frequent switching capacity conforming to IS: 283, IS: 13340 and IS 13341 fitted with special sequential pressure sensitive disconnector.(ii) A set of capacitive duty contactor and realy of suitable ratings of 3 phase, 415 V.(iii) Incoming MCCB suitable for 100KVAR to ensure positive isolation of capacitors from both sides when the unit is off including quick make and break type with replaceable contacts conforming to 1100 volt grade with cable entry from bottom.(iv) Ammeter with CT, Voltmeter, power factor meter RYB indication, selector switch. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender