Tender For Provn Of Solid Waste Management (Swm) Plant For Bd Bari Mil Stn Under Ge Kaluchak
Tender Overview
Project Description
Tender for Provn Of Solid Waste Management (Swm) Plant For Bd Bari Mil Stn Under Ge Kaluchak
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Oct-2026 | Corrigendum No-1 | Date | 05-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part I to X under Ser No. 1.01 to 1.10 are Prepriced by MES. |
| 2 | Lump sum price worked out by the Contractor for “BUILDING WORK” as listed in Schedule ‘A’ Part-I |
| 3 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part-II |
| 4 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Part-III |
| 5 | Lump sum price worked out by the Contractor for “EARTHWORK FOR SCH ‘A’ PART- II TO III and PART-V to Part XI ” as listed in Schedule ‘A’ Part-IV |
| 6 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY WORKS” as listed in Schedule ‘A’ Part-V |
| 7 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part-VI |
| 8 | Lump sum price worked out by the Contractor for “ROADS/PATH WORKS” as listed in Schedule ‘A’ Part-VII |
| 9 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part-VIII |
| 10 | Lump sum price worked out by the Contractor for “AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Part-IX |
| 11 | Lump sum price worked out by the Contractor for “SECURITY FENCING AND STEEL GATE WORKS” as listed in Schedule ‘A’ Part-X |
| 12 | SCHEDULE `A' PART - XI MISC B/R & E/M ITEMS is not prepriced by MES |
| 13 | EXTERNAL ELECTRIFICATION WORKS |
| 14 | Platform for installation of transformer of size 3x2.5x1.25 including fencing and gate all as shown in Drawing No CEPZ/TD-350/08 Sheet 1/2 dated 14 Nov 2008 and CEPZ/TD-350/08 Sheet 2/2 dated 14 Nov 2008 and as specified & directed. |
| 15 | Supply and installation of silent Diesel Engine driven generating set of make 100 kVA Liquid Cooled Standard Diesel Generating Set Comprising of make Liquid Cooled CRDi 4K1080ETA 4G1 (CPCB IV+ Norms compliance) developing 156 BHP @ 1500 RPM Directly coupled with 100 kVA Green Alternator rated at 3 Phase 415Volts ,50 Hz and 0.8 p.f. both mounted and Aligned on Common Base Frame complete with inbuilt MS Fuel Tank, Residential Exhaust Silencer, AVM pads fitted on Base Frame 1 No's Kirloskar Battery of suitable capacity for 12 Volts Operating System, KRM (Kirloskar Remote Monitoring) and Integrated Manual Panel with feature of Auto Start and Auto Stop subject to (Auto-Changeover in Customer's Scope) all housed in Acoustic Enclosure complete with foundation (as per OEM design), complete all as specified and directed by Eng in charge. |
| 16 | M&L outdoor type street light junction boxes with PVC water tight encloser, ready made type, with provision of suitable size 25/35 sqmm 3.5core cable including aluminium bus bars for three phases and one neutral mounted on insulators and bus bar having provision of 10-32 A SP MCB terminal connection and inter connection of street light from pole to pole and pole to light fittings including necessary PVC insulated waather proof twin core 2.5 Sqmm (nominal area) aluminium conductor cable, 1100 volts grade drawn and including PVC conduit of suitable size with clamps (3 Nos) , nuts, bolts etc from Junction box to street light connection, including taking down of existing unserviceable of junction box complete all as specified and as directed by Engr-in-Charge. |
| 17 | S&F Street light Bracket complete made of GI pipe of suitable 40 mm size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , all as specified and directed by Engg- in Charge. |
| 18 | Supply and fixing in replacement of automatic street light timer switch suitable for 3 phase switch using nature switch for automatic switching of street light based on LUX level of nature light. The sensor (Nature switch) and mannual on/off alongwith suitable power contractor, MCB and support terminal should be enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Sintex make) conforming to IP-54 including contractors (3 Nos each) and incoming-outgoing MCBs (3 Nos each) rating 20-30 Amp and circuit wiring of minimum 10 Sqmm.complete all as specified and directed. |
| 19 | Supply & fix Supply & fix Microprocessor based three phase four wire electronic tamper proof energy meter of rating 10 to 60 Amp with optical communication port conforming to IS: 13779. complete all as specified and direceted by Engr-in-charge. |
| 20 | Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type indoor Confirming to IS 8623 Part 1 1993, free floor standing / wall mounting factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, Outgoing MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer Outgoing MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing Outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size as designed by the manufacturer . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories: |
| 21 | 1) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps. |
| 22 | 2) Main incoming MCCB four pole 415 V AC, current rating 200 amps, breaking cap 36 KA at 415 volts |
| 23 | 3) Outgoing MCCB four pole 415 V AC, current rating 160 amps,breaking cap 36 KA at 415 V AC = 02 Nos |
| 24 | 4)Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking capacity 25 KA at 415 volt = 01Nos |
| 25 | 5) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,neutral currant, |
| 26 | 6)LED indicator (R,Y,B) of suitable capacity |
| 27 | 7) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. |
| 28 | 8) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 1 |
| 29 | 9) Installing,commissioning ,testing,earth work PCC etc. |
| 30 | Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type outdoor Confirming to IS 8623 Part 1 1993, free floor standing / wall mounting factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing Outgoing MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer Outgoing MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing Outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size as designed by the manufacturer . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories: |
| 31 | Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 250 amps. |
| 32 | Main Incoming MCCB four pole 415 V AC, current rating 160 amps, breaking cap 36 KA at 415 V = 01 Nos |
| 33 | Outgoing MCCB four pole 415 V AC, current rating 125 amps,breaking cap 36 KA at 415 V AC = 02 Nos |
| 34 | Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking capacity 16 KA at 415 volt = 01 Nos |
| 35 | LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KVA,neutral currant, |
| 36 | LED indicator (R,Y,B) of suitable capacity |
| 37 | Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. |
| 38 | Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 1 |
| 39 | Installing,commissioning ,testing,earth work PCC etc. |
| 40 | Supply and fix Cable path indicator with cast iron plate 100mm dia, 5mm thick engraved with HT Cable of size as provided fixed on angle iron frame of size 40 X40 X6 mm, 40 cm long by means of bolts, nuts, washer ,or welding and embedded in PCC 1:3:6, Type C2 block of size 15 X15 X20 CM including excavation as directed. |
| 41 | EXTERNAL WATER SUPPLY WORKS |
| 42 | Cutting existing 80/100/150 mm GI pipe and inserting GI Tee of size 100x100x50 mm for tapping including necessary earth work and making flange for connection of new 50 mm of GI pipe including all as specified and directed by Engr-in-Charge. |
| 43 | SEWAGE DISPOSAL WORKS |
| 44 | S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete for 10 user conventional type all as specified. |
| 45 | Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 m x 3.00 m effective depth complete all as specified and directed |
| 46 | S&F 150mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer's instructions and as directed. (Bedding/Haunching and earthwork paid separately under respective items of schedule) complete all as specified and directed |
| 47 | REFUSE DISPOSAL WORKS |
| 48 | Supply, fixing, Testing and Commisioning Organic Waste Shredder ( Capacity to shred all types dry & semi wet agricultural/kitchen produce bio mass, wood sticks, coconut leaves etc in to small pieces for compost) , with motor capacity upto 15 HP (7.5 HP x 2) dual shaft type , Three phase Supply, 440 Volt,50 Hz, working/shredding capacity -500 Kg /Hr, complete all as specified and as directed.Note: Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor. |
| 49 | Supply, fixing, Testing and Commisioning Kill Waste Machine 250 Kg/Hour Fuel-Free Solid Waste Disposal System with pollution control device, complete all as specified and as directed(i) Material- Non-Corrosive mild carbon steel of IS2062-GRADE B category Cylindrical Chamber as specified by BIS.(ii) Pollution Control Device: Multi-Level Wet Scrubber, with activated charcoal filter, baffle filter, emission testing port.(iii) Chimney made up of Stainless Steel (iv) Additional Neck Reinforcement for storm proof(v) Necessary Thermal Insulation of (Cement concrete,Fire brick,Glass wool, Aluminium sheet)(vi) Body Parts as following: (1) Upper cone (2) Cylindrical Chamber (3) Lower cone (4) Loading door (5) Inspection door (6) Ash door.Note: OEM should produce certificate and test report of emissions as per SWM rule 2016 after installation & Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor.complete all as specified and directed |
| 50 | Supply, fixing, Testing and Commisioning Dry Waste Shreeder (capacity to shred Organic waste, Wet waste ,Kitchen waste etc) dual shaft with motor capacity of 15 HP (7.5 HP x 2) , 3 Phase supply, (440 Volt/ 50 Hz) shredding capacity -500 Kg/Hr, Harden Blade material of high quality, complete all as specified and as directed.Note: Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor. |
| 51 | Supply, fixing, Testing and Commisioning Industrial Grade Fly Catcher/Insect Killer Machine , comprises of fitting on Wall/Ceiling, UV Tubes ( 4 x 20 W), Power Consumption Upto 100 W, Effective area Open approx 900 sq ft , Design for high Roof Area, Heavy and strudy, Big size bottom tray to collect dead insects, MS Epoxy powder coated body, complete all as specified and as directed.Note: Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor. |
| 52 | Supply, installation and commissioning of Hydraulic Baling Machine of 50 kg bale capacity suitable for compressing recyclable dry waste such as plastic, paper, cardboard, packaging waste, etc., for forming compact pallet/bale shape to facilitate easy handling, storage and transportation (TPT). Machine complete with heavy duty compression chamber, hydraulic power pack, electric motor, control panel, safety interlock door and bale tying arrangement. Technical Specifications:Capacity : 30TonWeight of bale : 50-60 kgBale size : 700mm X 500mm X 650mmFeed opening : 700mm X 500mm X 1400mmPlateform size : 700mm X 500mm X 30mmMaximum table travel : 950mmThickness of the body Plate : 8-10 mmDay light gap : 1200mmEjection of bale : By Metal WireElectric motor : 7.5 HP 3Phase 1440 RPMNo of cylinder : 1Body MS Body : FabricatedNo of belts : 2-3Cycle time : 70 secHydraulic pressure : 1800-2000 PsiOil drive : Gear pump systemOperation : Manually by Hand leverWorking fluid : Hydro Enclo 68Oil tank capacity : 80-90 LitersMaterial to be baled cardboard waste/ paper/ Pet Bottle etcNote: Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor complete all as specified and as directed. |
| 53 | Supply,installation,testing & commissioning of Fully Automatic Organic Waste Composter Machine Capacity with Inbuilt Shredder Composting in 24 to 48 hrs 1000 Kg Per Day Organic Manure 80-90% Depends on Material Fully Automatic 440 volts three phase 5 K.W. 3Phase, 1Neutral electrical supply with 63amp MCB Preparation/ Foundation for machine &Covering/shed complete all as specified and as directedNote: Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor. |
| 54 | Supply,installation,testing & commissioning of Smokeless Solid Waste Incinerator having capacity 80 pads per cycle/ 1200 pads per day for burning of hazardous and medical waste made up of SS 304 1 mm with external dimensions 750x480x390 mm operated on Voltage 220V, Wattage 2600W peak. Incorporated with Quick Burn Induction Heater of 2000W, Flue gas pipe of 1 mtr SS pipe with 3 inch dia, Safety MCB i.e 25 Amp RCCB + 16 Amp MCB, Ash collection tray shall be easily openable and disposable; complete all as specified and directed. Note: Comprehensive Coverage with AMC for 02 years to covers all preventive maintenance, breakdown repairs, calibration, and replacement of defective parts without extra charge will be borne by Contractor. |
| 55 | S&F in repair fully retro reflective sign board 1.5 Mtr x 1.2 Mtr board made out of 3 mm thick ACP (aluminum composite panel) sheet framed with 40 mm dia and wall thickness 3.0 mm stainless steel pipe having all sides and entire surface fully bonded with retro reflective sheeting of HIP (High Intesity Prismatc) grade having pressure sensitive adhesive. Borders and messages as indicated cut out. Background in blue and matter in white colour tape having two posts of 50mm dia wall thickness 3.0 mm stainless, steel pipe 4.50 mtr long any shape, size, design as a vertical supports and embedded in ground with PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) of size 450 x 450 x 600 mm incl necessary excavation and earth work complete all as specified and as directed. (One side with slogan and other side with indication as specified/directed). |
| 56 | Shed (02 Nos) and PIT (10 Nos) works |
| 57 | M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete |
| 58 | M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, all as specified and as directed. |
| 59 | M&L Rendering 15 mm thick on fair faces of brick/concrete surfaces in cement plaster 1:4, by using liquid water proofing compound finished even and smooth without using extra cement, complete, all as specified and as directed. (WPC measured and paid separately) |
| 60 | M&L Rendering 10 mm thick on internal surfaces of in cm 1:6, finished even and smooth without using extra cement. |
| 61 | Supply only Liquid water proofing compound. |
| 62 | S&F steel work in tubular post and rectangular/sqaure hollow section incl special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade-240 complete all as specified and directed. |
| 63 | S&F Roof Truss (Framed), trussed, purlins, crane gantries, rails And fastening and heavy bracket framming (Beam,Tee,angle and other section) incl distance pieces, cleats etc conforming to Fe-410 W (Grade E-250) quality A complete all as specified and directed |
| 64 | S & F MS framed work such as in gate grills, gratings, framed guard bars, angle iron, plate etc and similar work including necessary pintle hinges, stops, welding, riveting, bolting , hold fast , sliding bolt and other necessary fitiings confirming to Fe 410-0 or Fe 310-0, all as directed |
| 65 | S& F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified and directed as per Engr in charge/GE. |
| 66 | RCC M-20 (Design mix) as in foundation ,including rafts, footing foundation beams, plinth beams for columns. etc complete all as specified. |
| 67 | Formwork to sides of concrete foundation, footings bases of columns, raft and raft beams, plinth beams and similae work vertical or to batter complete with Rough finished flat surfaces complete all as specified. |
| 68 | M&L TMT bar 10 mm dia and over , cut to length, bend to as required including cranking, bending an binding with annealed wire not less than 0.9 mm dia complete all as required. |
| 69 | M&L TMT steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders in reinforcement , cut to length, bend to as required including cranking, bending an binding with annealed wire not less than 0.9 mm dia complete all as required. |
| 70 | Hard core of gauge n.exc. 63 mm, deosited spread and levelled in layers n.exc. 15 cm thick using broken stone or boulders, watered and rammed to a true surfaces. |
| 71 | M&L for 75 mm thick PCC 1:3:6 type C-2 using (40mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed. |
| 72 | M&L for 25 mm thick PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed. |
| 73 | 75 mm thick PCC 1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 74 | Providing cement concrete type B0 1:2:4 (12.5 mm graded aggregate) in lintel upto 1.50 m clear span, cill, steps, seismic and other similar bands, plinth course, stringe courese coping, kneelers, bed plate etc complete all as specified and directed. |
| 75 | M&L for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over chalk whitening finish wall surface even & smooth all as specified and directed. |
| 76 | M&L for preparation for newly plaster surface for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot tinted) with silicon additives @ 1.43 litre/10 Sqm iver abd including priming coat of exterior primer applied @ 0.90litre/10 sqm over new surface. |
| 77 | Preparation of new steel surface over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 78 | M&L for 100 mm thick PCC 1:4:8 type D-2 using (40mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents