Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57646957

Tender For Repair/ Replacement Of Unsv Parts Of Ac Plants At Aftc And Unsv Duct Insulation, Underdeck, Robotic Cleaning Of Ducts, Grill, Diffuser And Replacement Of Unsv Duct At Bhdc Under Ge (East) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
40 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
10 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Unsv Parts Of Ac Plants At Aftc And Unsv Duct Insulation, Underdeck, Robotic Cleaning Of Ducts, Grill, Diffuser And Replacement Of Unsv Duct At Bhdc Under Ge (East) Delhi Cantt-10

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF UNSV PARTS OF AC PLANTS AT AFTC AND UNSV DUCT INSULATION, UNDERDECK, ROBOTIC CLEANING OF DUCTS, GRILL, DIFFUSER AND REPLACEMENT OF UNSV DUCT AT BHDC UNDER GE (EAST) DELHI CANTT-10
Sl. No. Item Description
1Supply, assembly and erection in replacement GI sheet 24 gauge with C & SS rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engr-in-Charge including making of hole in any type of wall and making good with plastering work, masonry work and necessary MS channel supports complete all as specified and directed
2Description all as per item No. 01.00 above here in after but GI sheet 22 gauge
3Supply & erection in replacement 19 mm thick nitrile duct thermal insulation with Aluminium foil, non-fibrous, fire retardant, closed cell, tri- dimensional, chemically cross linked polyethylene foam, confirm to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
4S&F in replacement acoustic lining of supply air ducting complete with GI frame, tissue paper, 26 Gauge perforated Aluminium Sheet, 25mm thick, of density 32 Kg/cum fiber glass insulation complete all as specified and as directed.
5M & L in replacement under deck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting in following operations complete all as directed and specified:- (a) S&F in replacement 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof.(b) S&F in replacement 22 SWG GI/ Aluminium wires supports for insulation.(c) S&F in replacement chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same.(d) S&F in replacement under deck insulation with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting.Note:- Insulating material shall be conforming to BS - 476, Part 4, 5, 6 & 7.
6S&F in replacement Acoustic treatment/ lining of area of AHU room with 22 Gauge, GI channels of 50x50 mm size fitted at 600x600mm girds, fitted with 50mm thick, 32 Kg/cum fibber glass insulation, covered with fibber glass tissue and 24 Gauge Aluminium perforated sheet as required, The joint shall be with minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering, All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed.
7Supply, installation, testing and balancing in repair square shape supply air diffusers with removable core and antismudge ring and volume control dampers, powder coated, extruded aluminium construction complete all as specified and as directed.
8Supply, installation, testing and balancing in repair square shape return air diffusers with removable core and antismudge ring and without control dampers, with powder coated, extruded aluminium construction complete all as specified and as directed.
9Supply and apply tack coat of STARBOND 30-36 of following items for out door ducting. (a) After eraction nitrile duct thermal insulation apply tack coat of STARBOND 30-36 and embed the selective lagging fabric (glass fiber cloth/canvas cloth) immediately.(b) Apply first coat STARBOND 30-36 by brush or roller when tack coat is cured that is 2-3 hours. (c) Apply final coat STARBOND 30-36 by brush or roller after first coat is fully cured.
10Supply and fixing in replacement air volume control damper with connected accessories, made out of 22 Gauge GI sheet with flap and operatig handle complete all as specified and as directed.
11Supply and fixing fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct complete with nuts, bolts complete all as specified and directed.
12Supply, installation, testing and balancing of Return air grill without damper powder coated extruded aluminum construction complete all as specified and directed.
13Supply, installation, testing and balancing of Supply air grill with aluminum damper powder coated extruded aluminum construction complete all as specified and directed.
14Supply, installation, testing and commission of UL-555 motorized fire dampers of required size complete with smoke detector/ thermister linkage etc in AHU Room Supply Air Ducts as required for operation complete all as specified and directed.
15Supply, installation, testing and commission of Actuator with control panel in AHU Room Supply Air Ducts as required for operation complete all as specified and directed.
16M&L for air duct cleanning filter vacuum unit and high pressure as required, robotic video camera must we used for inspection, cleaning of duct. While using robotic camera the video filmcopied on CD (before and after cleaning) will be kept on record by the Engineer-in-charge complete all as specifed and directed.
17Supply and fixing in replacement of venturies of VRF/VRV outdoor unit of capacity upto 30 HP complete all as specified and directed.
18Supply and fixing in replacement of GI Pipe 80mm dia heavy class fixing on wall for ducting supports including making of hole in any type of wall and making good with plastering work, masonry work complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57646957
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 13-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Unsv Parts Of Ac Plants At Aftc And Unsv Duct Insulation, Underdeck, Robotic Cleaning Of Ducts, Grill, Diffuser And Replacement Of Unsv Duct At Bhdc Under Ge (East) Delhi Cantt-10
Basic Detail
Tender No GE/DE-168/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 22 Sep 2026
Submission Date 13 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_886318.xls
dc2f1b0e-d4f2-43e1-9994-c45c86d76f21.html
Tender168.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_886318.xls

html

dc2f1b0e-d4f2-43e1-9994-c45c86d76f21.html

pdf

Tender168.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders