Tender For Special Repair Of Pathway At Scepta And Provision Of Three Gates Connecting Scepta And Dsoi And Certain Revenue Work At Si Lines Under Ge Bhopal
Tender Value
26.73 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
18 days left
EMD
53500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair Of Pathway At Scepta And Provision Of Three Gates Connecting Scepta And Dsoi And Certain Revenue Work At Si Lines Under Ge Bhopal
BOQ
| Sl. No. | Item Description |
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 3 | Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing outside MD land complete all as specified and directed. |
| 4 | Surface dressing n exc 30 cm deep and averaging 15 cm deep and getting out in hard dense soil complete all as specified and directed. |
| 5 | M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 6 | M&L for 25mm thick in PCC 1:2:4 type B0 using (using 12.5mm stone aggregate) as in bedding layer for laying in floor as in levelling course complete all as specified and directed. |
| 7 | M&L for Reinforced cement concrete (design mix) M-20 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 8 | M&L for brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 9 | M&L rendering 15 mm thick on fair face of brick work or concrete surfaces or brick masonry surfaces or surface in CM 1:4 finished even and rough complete all as specified and directed. |
| 10 | M&L for preparation of newly plastered or unplastered surfaces in walls soffits, facia, chajjas and applying two coat of exterior weather proof water based emulsion (100% acrylic)over a coat of compatible primer complete all as specified and directed. |
| 11 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 12 | M&L mild steel of 1.60 mm thick, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 13 | M&L for heavy duty full body vitrified outdoor tiles minimum 10mm thick (square/rectangular) area of each tiles not exc 0.36 sqm, in floors set and jointed in neat cement slurry and fixed over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 14 | M&L for 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms with rounding of edges and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified and directed. |
| 15 | Labour only for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 16 | M&L TMT reinforcement bars 8mm and above using cut to length bent to shape as required including cranking bending spirally for hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securig with clips etc complete all as specified and directed. |
| 17 | S&F Providing and laying 60mm thick rubber moulded factory made chamfered edge cement concrete glossy finish paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, laid in required colour & pattern over and including 45-50 mm thick compacted bed of fine river sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer and filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed |
| 18 | S&F Providing and laying 80mm thick rubber moulded factory made chamfered edge cement concrete glossy finish paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, laid in required colour & pattern over and including 45-50 mm thick compacted bed of fine river sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer and filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed |
| 19 | S&F Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 20 | M&L Providing, cement concrete 1:2:4 type B1 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including neccessary formwork. |
| 21 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Dismantling wall and ceiling board (fiber, pulp, insulation etc) or insulation board, slabs, blanket, ant thickness, including cover flats complete all as specified. |
| 22 | S & F of WPC Louver sheet (of approved color & texture) in seamless ceiling/ wall of minimum 17 mm thickness and 1.5 mm wall thickness fixed in frame with necessary fixing screw and clips or solvent complete all as specified and directed. |
| 23 | S&F mild steel rolled sections as in main and cross beams,hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates conforming to Fe-410 grade, cutting,drilling,notching,welding/bolting/riveting ,hoisting, erection and fixing in position including all necessary angle cleats,cnoncting plates ,nuts,bolts and washers complete all as specified and directed |
| 24 | M&L for preparation of new steel surfaces over 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed |
| 25 | Taking down carefully copper/aluminium point wiring concealed/ casing caping (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed. |
| 26 | Dismantling/taking down of unserviceable old existing service /submain wire of any size all as specified and directed |
| 27 | Taking down LED 2x2 feet pannel ceiling lights any type and deposited to SI Line E/M store yard safely without any damage and in working condition all as specified and as ditrcted. |
| 28 | Taking down any type of ceiling fan and deposited to SI Line E/M store yard safely without any damage all as specified and as ditrcted . |
| 29 | Taking down of any type of decorative wall/hanging lights deposited to user store and refixing the same without any damage and in working condition complete all as specified and as ditrcted . |
| 30 | M&L for concealed point wiring for one light/one fan/one exhaust fan controlled by one switch complete with and including single core PVC insulated unsheathed FRLS copper conductor 1.5 sqmm cable as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium grade PVC conduit as per IS 9537 (Part-III): 1983 not less than 20mm nominal dia including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and with addtional single core PVC insulated unsheathed FRLS copper conductor 1.5 sqmm multistarands cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed Note:- cost of cutting chase and making good shall be included in the quated rates. |
| 31 | All as per ser item No.29.00 here-in-before but for socket outlet 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge. |
| 32 | All as per ser item No.29.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge. |
| 33 | All as per ser item No.29.00 here-in-before but for socket outlet 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge. |
| 34 | All as per ser item No.29.00 here-in-before but for one socket outlet 3 pin 5/15 Amps on independent board with wire of size 4.0 Sqmm complete all as specified and directed by Engineer - in - Charge. |
| 35 | S&F modular switch, one way, 6 Amp one module, 240 volts ISI marked complete all as specified and directed by Engineer - in - Charge |
| 36 | Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts,ISI marked controlled by one switch complete all as specified and directed by Engineer - in - Charge |
| 37 | S & F modular switch one way 16 Amp one module, 240 volts ISI marked complete all as specified and directed by Engineer - in - Charge |
| 38 | Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, ISI marked controlled by one switch complete all as specified and directed by Engineer - in - Charge |
| 39 | Supply and fixing ceiling fan brown in colour complete with blades, down rod, and accessories, 230 V, 1200 mm sweep. Min air delivery 220-230 CFM with service value 6.00 BEE.complete all as specified and as directed. |
| 40 | S & F in replacement stepped type modular electronic fan regulator 2 module complete all as specified and directed by Engineer - in - Charge |
| 41 | S&F modular ceiling rose 3 terminals 65x25 mm dia poly carbonate ISI marked all as specified & directed. |
| 42 | M&L for sub main wiring with approved colour coding as per IS with single core PVC insulated FRLS cable 1100V unsheathed 3 wires, (2 for phase and neutral and one for earth) with stranded copper conductor of 6.0 sqmm nominal cross section area,and drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable for phase and neutral and one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length. |
| 43 | M&L for sub main wiring with approved colour coding as per IS with single core PVC insulated FRLS cable 1100V unsheathed 3 wires, (2 for phase and neutral and one for earth) with stranded copper conductor of 4.0 sqmm nominal cross section area,and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable for phase and neutral and one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length. |
| 44 | Supply and fix modular combo AC box (incl socket ,plug top and 25 Amp MCB's) 240 V,50 Hz an ISI-marked, impact-resistant body and Built with high-impact polycarbonate materials that offer high softening temperatures, ensuring long-lasting performance complete all as specified and directed . |
| 45 | S&F in repair sheet metal enclosure, double door type, surface mounted concealed in wall 12 ways, 240 Volts, IP 43 ISI marked 200 amps bus bar dust and vermin proof ( IP-54 protection )suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately. |
| 46 | S & F in repairs MCB, SP suitable for 240 volts, AC supply 6 to 32 Amps rupturing capacity not less than 10KA 'C' curve connection with suitable size copper lugs curve including complete all as specified and directed by Engineer - in - Charge. |
| 47 | S&F MCCB, 100 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed. |
| 48 | S & F in repair MCB SPN suitable for 240 volts, AC supply 40 Amps and rupturing capacity not less than 10KA 'C' curve connection with suitable size copper lugs complete all as specified and directed by Engineer - in - Charge. |
| 49 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 4 core all as specified & directed. Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule) |
| 50 | Supply and fixing in replacement factory made epoxy powder coated, Distribution Board TPN 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed.NOTE:- MCCB shall be measured and paid seperatly. |
| 51 | M&L earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately. |
| 52 | S&F of PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm multi strandrands copper conductor AC, 230 V complete all as specified and directed. |
| 53 | S&F non metalic heavy grade PVC conduit ISI marked of size 20mm dia incl all accessories complete all as specified and directed. |
| 54 | S & F in replacement sheet metal enclosure, double door type, surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. |
| 55 | Supply and fixing of 45W, warm white decorative gate light Input Voltage: Typically 160V-280V AC, suitable for standard household voltage. Color Temperature: 3000K (Warm White) is standard for cozy, non-glare illumination, Luminous, waterproof IP-65,suitable for outdoor use.Material: Die-cast heat sink aluminum body (powder-coated, anti-corrosion) with a optical grade PC diffuser. RAL9005 matt black finish all as specified and directed.Make:- cat part no BL ANTIQUA EVO NX 45W WW C3 BL S PT of Bajaj or equivalent make of Hellonix/Havells as approved by GE. Note:-Contractor shall submit the sample of light for approval of GE before procurement. |
| 56 | Supply & Fix surface mounted 6 watt LED BUSH light pressure die-cast aluminium heat sink & clear PC as a cover in white powder coated finish with Independent electronic LED driver. mounting spot focous LED light round warm in colour with excellent thermally managed luminaire 9 watt , 220V AC withtoughned glass IP66, diffuser soft glare free light suitable for garden illumination including connecting up with driver three core flexible coppder conductor cases of suitable size complete all as specified and directed by Engineer in charge.Make:- Cat part No - BL SPYKZ Nx6W WW - of Bajaj or equivqlent make Hallonix/Havells / C&G/ Philips as approved by GE. |
| 57 | Supply & fixing in replacement LED garden light (BAMBOO LED BOLLARD) in cylindrical shape with opal acrylic diffuser aesthetically designed aluminium landscape and IP 66 protection with 9 Watt LED as light source 3 feet in height complete all as specified & directed. Make:- Cat part No-BGBOL 605 9W LED WW 1M of Bajaj or equivqlent Halles/Crompton C&G. |
| 58 | Supply and fixing of 5W warm decorative LED foot step light of efficacy 08 lm/W & Input Voltage: Typically 160V-240V AC, suitable for standard household voltage. Light Source: SMD LED or Epistar LED chips.Color Temperature: 3000K (Warm White) is standard for cozy, non-glare illumination.Luminous Flux: Approximately 100 lumens for a 3W model. IP Rating (Waterproofing) IP65 and IK06 suitable for outdoor useMaterial: Die-cast aluminum body (powder-coated, anti-corrosion) with aopal/clear diffuser.Lifespan: Often up to 50,000 burning hours.Dimensions: Common sizes include compact 165X 105X65mm Mounting Recessed (with a plastic mounting box) or surface-mounted all as specified and directed.Make:- Cat part No -BL RAZOR Nx 5W WW of Bajaj or equivqlent Hallonix /Havells / C&G/ Philips as approved by GE. |
| 59 | S&F of flexible LED strip uses high brightness SMD LED as the light source for indoor application, luminaire 24 watt, 220 Volts AC with high efficiency light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make:- Cat part No - LHEHDLPFUN1W024 (Flexion Neo Led Strip 24 W of any colour) of Havells or equivqlent make Bajaj/ C&G/ Philips as approved by GE. |
| 60 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil complete all as specified and directed. |
| 61 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed |
| 62 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 63 | M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 64 | M&L for providing of un-reinforced precast concrete cable cover class LV, Type 1 size 250mmx 150mm x 40mm laid flat dry for protection of under ground cable complete all as specified and directed.class,, flat, |
| 65 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable pipe and getting out in soft disintegrated rock all as specified and directed. |
| 66 | M & L for making good the disturbed surface by filling PCC 1:2:4 type B-1 using 20 mm graded course aggregate to match with existing surfaces all as specified and directed. |
| 67 | M & L GI Tubing \\"light grade\\" galvanized for protection LT Cable all as specified of size 40 mm bore complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply, fix, testing & commissioning of panel box fabricated with 3.15 mm thick MS Sheet having 4 Nos closed Aluminium bus bar of capacity 100 A (including necessary insulator) suitable for 3 phase & neutral, 4 wire 50 Hz AC,415V with incoming MCCB 63 Amps .415V,braking capacity of 25KA Thermal and megnetic release -01 nos and out going MCB SP 40 Amps braking capacity 25 KA thermal and megnetic release -02 nos 230 V including red,blue & yellow LED indication lamp and both side openable hinged cover with proper locking arrangement ,outdoor type weather and vermin proof powder coated mounted on frame made of angle iron 50x50x5mm 100 cm above ground level grouting including making PCC 1:2:4 type B-1 using 20 mm graded course aggregate also includes suitable size of cable glands,cable lugs,nut, bolts,washers etc for fixing of cable with the bus bar with legs of angle iron size 25X25X3 mm complete all as specified and directed. |
| 69 | Deduct Schedule of credit (calculation will be done off line) Rs. 8373.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender