Tender For Repair /Maintenance Of Apfc Panel, Lt Panel And Allied Works At Af Stn Jammu Under Ge (Af) Jammu
Tender Value
20 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
17 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Maintenance Of Apfc Panel, Lt Panel And Allied Works At Af Stn Jammu Under Ge (Af) Jammu
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting / taking down carefully existing unserviceable LT Panel Board any type and capacity including all control switches, fittings and fixtures from different location complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Supplying, Installing, Testing and Commissioning Outdoor type Cubical Panel Board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2.0 mm thick MS sheet and MS angle section 50 x 50 x 6mm mounted on platform of PCC 1:2:4 type B-1, 60 cm above and 45 cm below the ground level, Frame Factory fabricated with front and back openable, double door system and cable alley (Each door hinged with body at three places through weldeding) Lockable / Openable by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for Three Phase Four Wire 415 Volts, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it Dust / Vermin Proof and general construction confirming to IS:8623/93 comprising of the following :(a) Busbar rating 800 Amps Capacity 4 wires fixed on insulator not less than 1.0 mtr long bus bar - 01 Set(b) Incoming MCCB 630 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 50 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 Nos.(c) Outgoing MCCB 250 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 Nos.(d)Outgoing MCCB 200Amps F 415 Volts AC with adjustable thermal magnetic trip release 36 KA,Ics=100%, Icu class-2 front face isolation with (+) break indication with double break contacts with spreader and phase barrier 1 Nos. Please Enable Macros to View BoQ information |
| 3 | Supplying, Installing, Testing and Commissioning Outdoor type Cubical Panel Board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2.0 mm thick MS sheet and MS angle section 50 x 50 x 6mm mounted on platform of PCC 1:2:4 type B-1, 60 cm above and 45 cm below the ground level, Frame Factory fabricated with front and back openable, double door system and cable alley (Each door hinged with body at three places through weldeding) Lockable / Openable by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for Three Phase Four Wire 415 Volts, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it Dust / Vermin Proof and general construction confirming to IS:8623/93 comprising of the following :(a) Busbar rating 800 Amps Capacity 4 wires fixed on insulator not less than 1.0 mtr long bus bar - 01 Set(b) Incoming MCCB 630 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 50 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 Nos.(c) Outgoing MCCB 250 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 Nos.(d)Outgoing MCCB 200Amps F 415 Volts AC with adjustable thermal magnetic trip release 36 KA,Ics=100%, Icu class-2 front face isolation with (+) break indication with double break contacts with spreader and phase barrier 1 Nos. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender