Project Description

Tender for General-Standardisation To Electrical Installations At Civil Station, Palakakd-Work-General Electrical Work

BOQ

Name of Work:- GENERAL-Standardisation to electrical installations at Civil Station, Palakakd-work-General Electrical Work
Sl. No. Item Description
1ELECTRICAL WORK
21.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
31.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
44.1.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
590.12.10.6:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation110/94 mm or nearest size
62.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
72.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
82.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door
990.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
1090.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1190.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
1290.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
1390.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
1490.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
1590.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
1690.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
1790.14.7:Supply and providing copper earth bus in the panel board
182.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
192.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
20OD106881/2024-2025:Supplying and fixing 40 amps to 63 amps rating, 415 volts,C- curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB completewith connections, testing and commissioning etc. as required.-Triple pole
2190.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
2290.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
232.2.14:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.125 Amp, 36 KA
242.2.15:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.200 Amp, 36 KA
25OD74343/2026-2027:Providing and fixing following rating and breaking capacity MCCB withthermo magnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.400 Amp, 50 KA, 4 pole with Isolation duty
2690.14.11.2:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to 200A with CBCT.
2790.14.11.3:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.
28OD44053/2026-2027:Supply and fixing of Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating upto 250 A (8 pcs) and giving connection etc as required.
29OD44080/2026-2027:Supply and fixing of Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating up to 400 A (8 pcs) and giving connection etc as required.
30OD107846/2024-2025:Supply of fuse puller 0-630A range
31OD107853/2024-2025:supply and fixing Digital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 1 LED
32OD107855/2024-2025:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
33OD107856/2024-2025:Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength
34OD107862/2024-2025:Supply and fixing push button station enclosure 1/2/3 hole
35OD107863/2024-2025:supply and fixing illuminated push button with actuators
36OD107865/2024-2025:Supply and fixing Add on Auxilary Contact block 1 NO+ 1 NC to the contactor L and T make/eqt
37OD107866/2024-2025:Supply and fixing Add on Auxilary Contact block 2 NO+ 2 NC to the contactor L and T make/eqt
3890.14.11.14:MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
3990.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
40OD10495/2026-2027:Suply & fixing the Push button station enclosure with 1/ 2/ 3 hole
41OD10498/2026-2027:Supply and fixing 2A SP MCB L and T make/eqt
42OD10499/2026-2027:supply and fixing Blue colour LED indicator, AC/DC, 22.5 mm cut out dia
43OD10500/2026-2027:supply and fixing Red & Yellow LED indicator, AC/DC, as required
4490.14.24.68:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
4590.14.24.71:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
46OD11728/2026-2027:Supply and fixing 3 Pole Capacitor duty contactor with AC coil for switchingcapacitor banks of rating 5kVAR with AC Coil in the existing panel assembly asrequired.
47OD11744/2026-2027:Supply and fixing 3 Pole Capacitor duty contactor with AC coil for switchingcapacitor banks of rating 10kVAR with AC Coil in the existing panel assembly asrequired
48OD107868/2024-2025:Supply & fixing 8 stage 440 / 110 V 5A/1A, Intelligent Power Factor Controllers (IPFC)
49OD11708/2026-2027:Supply and providing selector switch 415V ,4pole ,2 way for auto/manual operations.
50OD44116/2026-2027:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required. 2.50 sq mm wire single run
51OD11709/2026-2027:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.4.00sq mm wire single run
52OD11710/2026-2027:Supply and Installation of Illuminated Flush head Actuator - Green with legend 'ON', (Contact -1NO) in the existing panel board, Including all necessary wiring and connections.
53OD11711/2026-2027:Supply and Installation of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact -1NC) in the existing panel board, Including all necessary wiring and connections.
5490.12.5.34:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
5590.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
5690.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
5790.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
5890.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
5990.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
6090.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
6190.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
6290.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
6390.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
6490.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
6590.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
6690.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
6790.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
6890.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
6990.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
709.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
719.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
729.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
739.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
749.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
759.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
769.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
779.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
789.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
7990.11.1.20:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
802.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
812.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
822.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
832.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
842.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
852.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
862.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
87OD107377/2024-2025:Supply & Laying of 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
88OD107378/2024-2025:Supply & Laying of 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in the existing masonry open duct as required
8910.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
9010.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm
91OD107379/2024-2025:Earthing with G.I. earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with 450x450x10mm cover plate and watering pipe of 2 metre long etc. with charcoal/ coke as required
925.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
93OD10752/2026-2027:Supply and Fixing 400/5 A, 15 VA, accuracy class 0.5, Resin Cast Metering CT with all necessary connections
94OD10783/2026-2027:Supply and fixing 200/5 A, 10 VA, accuracy class 1, Resin Cast Metering CT with all necessary connections
95OD11580/2026-2027:Supply and laying the following sizes of strips laid 0.60 m below ground levelincluding excavating trench of suitable size and refilling etc. as required.40 x 6mm GI strip
96OD11536/2026-2027:Providing and fixing 40x6 mm X 6 mm G.I. strip earth lead from the test joint to the earth plate
97OD11593/2026-2027:Supply and providing 25x6 mm brass bolt and nut with washer including drilling holesas required.
9890.16.3.4:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 3 mm GI strip
9990.16.4.4:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 3 mm GI strip
10090.16.3.2:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm GI strip
10190.16.3.3:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip
102OD367257/2025-2026:Supply, conveyance, Installation, testing and commissioning of 250 KVA Indoor type unitized substation comprising of HT panel trunked with Cast Resin Transformer with with800A VCB on H.T. side and bottom / top entry cable box and 400 A 4pole 50Ka (I cs=100%Icu) micro processor MCCB on the LT side as per technical details furnished below:HT SIDE: On suitable size CC foundation: H.T Portion HT portion shall consists of1. 1 No 11K.V, 800A, VCB with 3O/C relay with high set elements, one E/F relay with DC trip with earth inter lock with main switch and mechanical ON/OFFIndication2. Horizontal Draw out VCB fitted with manual/ motor operated spring charging mechanism with 230V AC motor and motor control switch.3. Shunt trip coil for the remote operation of the VCB4. CT and PT unit for Voltage and current reading including 3Nos & 1 nos 0-60A digitalAmmeter and 0-12V 3Phase digital voltmeter.5. Protection CT (__/5A), 5P10, 15VA , 11KV/110V,25 VA PT & including Supply & providing 3 Phase, 4 wire, 110 V (L-L), -/1 A CT or -/5A CT, accuracy class 0.2S class, TOD meter . Transformer portion:1. Supply of 250 KVA, 11 KV/ 433 V, 50 Hz, Dyn11 Dry Type Cast resin insulatedCopper wound transformer. The core shall be made of high grade laser scribed coreand shall be protected against corrosion by epoxy resin finish. Class F insulation levelshallbe maintained. The maximum total loss of the transformer shall meet latestECBC standards.OFF load tap changing facility shall be incorporated so as to achieve tap position from+5% to -10% in steps of 2.5% changeable by tap links. Winding Temperature indicator with trip Annunciator is to be provided.The transformer shall confirm to IS 2026: Part 11 2021/ IEC 60076-11:2018 Dry typeTransformer. The transformer shall be subjected to all routine tests as per the relevantIS/ IEC standards and shall have all other standard fittings as per IS: 2026.IS/ IEC standards and shall have all other standard fittings as per IS: 2026.All inter connection from HT load break switch to transformer and to LT breaker shallbe given using Copper bus bars and support insulators. All internal earth connectionsare to be given as per standards. Necessary protection shall be made for giving cableConnections on the HT side as well as LT side including LT Cable Box. Phase barriersAnd shrouding as per rules has to be given. The USS shall have suitable enclosure forProviding CT PT unit and TOD metering facilities and neutral CT on earthed star point with connector for connection to REF relay provided in Main panel. The enclosure shall comply to IP 54 standards made of 2 mm CRCA sheet and shall have provisions with Epoxy powder coating the assembly after subjecting to 7 tank processes. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation and efficient Cooling, required including Danger boards, signage, lettering etc. required as per standards. The USS shall be installed at site as per the directions of Engineer in charge. The USS should have warranty of 3 years from the date of Installation.
103OD11973/2026-2027: SITC of 160 A ATS including Controller with wire harness for automatic Change over in the existing panel board and giving connection L n T make/ equivalant
104OD12132/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.6 core 2.5 sq mm wit
1052.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
106OD107870/2024-2025:SITC of fire extinguisher dry chemical powder (ABC) stored pressure type 4kg capacity as per IS:15683 with ISI mark and with initial charger and installation brackets.
107OD107850/2024-2025:Dismantling existing MCB DB/VDB/MCCB DB, fixing it at new place with out any damage and complete with connections, making good the damages etc
108OD11712/2026-2027:Dismantling the existing Panel Boards, transporting the same to sectional store and making good the surface with matching finish including painting as per the direction of departmental staff
109OD107854/2024-2025:Painting letters or figures with enamel paint as identification mark to SB, DB, panel board etc 1as required
110OD11931/2026-2027:Copying charges o electrical/fire drawing per A3 sheet additional copies towards Electrical inspectorate
111OD11932/2026-2027:Cgarges for preparation of Electrical / fire drawing per A3 sheet first copy towards Electrical inspectorate Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57646023
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 26-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Standardisation To Electrical Installations At Civil Station, Palakakd-Work-General Electrical Work
Basic Detail
Tender No PWD/BLDG/6580/2026-2027
Bidding Type Tender
Location
City Palakkad
State Kerala
Key Dates
Publish Date 22 Sep 2026
Submission Date 26 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
1610f40d-b855-4533-81b2-734f847eba02.html
BOQ_1477785.xls
SBD2.pdf
Tendernotice_1 (20).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf
Tendernotice_4.pdf
viewnit.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

1610f40d-b855-4533-81b2-734f847eba02.html

xls

BOQ_1477785.xls

pdf

SBD2.pdf

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

pdf

Tendernotice_4.pdf

pdf

viewnit.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders