Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 8 days TDR #57644328

Bids Are invited for Replacement Of Vfd And Conversion Of Softstarter To Vfd At Paradeep Terminal

Issued by Boards / Undertakings / PSU · Jagatsinghapur, Odisha
Tender Value
23.14 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
8 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jagatsinghapur → Odisha
EMD Exemption
Available
Quantity
5

Project Description

Bids Are invited for Vfd For 110 Kw 206A Motor Pump Application - Supply Installation Testing And Commissioning Of Vfd In Existing Fo P19 Feeder 110Kw At Paradeep Terminal. The Feeder Has Soft Starter Installed In It. Scope Includes All Necessary Switchgears And Items Relay Contactors Sfus Fuses Ct Terminal Blocks Lugs Control Cables Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Soft Starter Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Be Below 839Mm X 284Mm X 371Mmai 02 Atleast Ao 02 Atleast Current Rating 206A Minimum At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 75 Kw 145A Motor Pump Application - Supply Installation Testing And Commissioning Of Vfd In Existing Fo P14 Feeder 75 Kw At Paradeep Terminal. The Feeder Has Vfd Installed In It. Scope Includes All Necessary Switchgears And Items Relay Contactors Sfus Fuses Ct Terminal Blocks Lugs Control Cables Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Vfd Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Be Below 722 Mm X 252 Mm X 369 Mm Ai 02 Atleast Ao 02 Atleast Current Rating 145A Minimum At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 37 Kw 73A Motor Pump Application - Supply Installation Testing And Commissioning Of Vfd In Existing Ethanol P4 Feeder 37 Kw At Paradeep Terminal. The Feeder Has Soft Starter Installed In It. Scope Includes All Necessary Switchgears And Items Relay Contactors Sfus Fuses Ct Terminal Blocks Lugs Control Cables Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Soft Starter Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Be Below 636M Mx 203Mm X 57Mm Ai 02 Atleast Ao 02 Atleast Current Rating 73.0A Minimum At 400V Or 45V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 110 Kw 206A Motor Pump Application Ss To Vfd - Supply Installation Testing And Commissioning Of Vfd In Existing Fo P15 Feeder (110Kw) With Soft Starter Installed At Paradeep Terminal Scope Includes All Necessary Switchgears And Items Relay Contactors, Sfus, Fuses, Ct, Terminal Blocks, Lugs Control Cables, Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Soft Starter Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Below 839Mm X 284Mm X 371Mm Ai 02 Atleast Ao 02 Atleast Current Rating 206.0A Minimum At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 110 Kw 206A Motor Pump Application Vfd To Vfd - Supply Installation Testing And Commissioning Of Vfd In Existing Hsd Tw Feeder (110Kw) With Vfd Installed At Paradeep Terminal Scope Includes All Necessary Switchgears And Items (Relay Contactors, Sfus, Fuses, Ct, Terminal Blocks, Lugs Control Cables, Panel Dressing And Tagging Etc) S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Vfd Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Below 839Mm X 284Mm X 371Mm Ai 02 Atleast Ao 02 Atleast Current Rating 206.0A (Minimum) At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder.

BOQ

Sl. No. Item TitleItem Description
1VFD for 110 KW 206A Motor Pump ApplicationSupply Installation Testing and Commissioning of VFD in existing FO P19 Feeder 110KW at Paradeep Terminal. The feeder has Soft Starter installed in it. Scope Includes All necessary Switchgears and items Relay contactors SFUs Fuses CT Terminal blocks lugs control cables panel dressing and tagging etc s Wiring Installation Commissioning Parameterization Panel related fabrication Wiring all complete Spray Paint Soft Starter dismantling and handing over adjacent panel wiring for installation of VFD if required etc. VFD SIZE MUST BE BELOW 839MM x 284MM x 371MMAI 02 atleast AO 02 atleast Current Rating 206A Minimum at 400V or 415V VFD Multiline control display to be installed outside panel and suitable cable connection to it is in the scope of the bidder.
2VFD for 75 KW 145A Motor Pump ApplicationSupply Installation Testing and Commissioning of VFD in existing FO P14 Feeder 75 KW at Paradeep Terminal. The feeder has VFD installed in it. Scope Includes All necessary Switchgears and items Relay contactors SFUs Fuses CT Terminal blocks lugs control cables panel dressing and tagging etc s Wiring Installation Commissioning Parameterization Panel related fabrication Wiring all complete Spray Paint VFD dismantling and handing over adjacent panel wiring for installation of VFD if required etc. VFD SIZE MUST BE BELOW 722 MM x 252 MM x 369 MM AI 02 atleast AO 02 atleast Current Rating 145A Minimum at 400V or 415V VFD Multiline control display to be installed outside panel and suitable cable connection to it is in the scope of the bidder.
3VFD for 37 KW 73A Motor Pump ApplicationSupply Installation Testing and Commissioning of VFD in existing Ethanol P4 Feeder 37 KW at Paradeep Terminal. The feeder has Soft Starter installed in it. Scope Includes All necessary Switchgears and items Relay contactors SFUs Fuses CT Terminal blocks lugs control cables panel dressing and tagging etc s Wiring Installation Commissioning Parameterization Panel related fabrication Wiring all complete Spray Paint Soft Starter dismantling and handing over adjacent panel wiring for installation of VFD if required etc. VFD SIZE MUST BE BELOW 636M Mx 203MM x 57MM AI 02 atleast AO 02 atleast Current Rating 73.0A Minimum at 400V or 45V VFD Multiline control display to be installed outside panel and suitable cable connection to it is in the scope of the bidder.
4VFD for 110 KW 206A Motor Pump Application SS to VFDSupply Installation Testing and Commissioning of VFD in existing FO P15 Feeder (110KW) with Soft Starter installed at Paradeep Terminal Scope Includes All necessary Switchgears and items Relay contactors, SFUs, Fuses, CT, Terminal blocks, lugs control cables, panel dressing and tagging etc s Wiring Installation Commissioning Parameterization Panel related fabrication Wiring all complete Spray Paint Soft Starter dismantling and handing over adjacent panel wiring for installation of VFD if required etc. VFD SIZE MUST BELOW 839MM x 284MM x 371MM AI 02 atleast AO 02 atleast Current Rating 206.0A Minimum at 400V or 415V VFD Multiline control display to be installed outside panel and suitable cable connection to it is in the scope of the bidder.
5VFD for 110 KW 206A Motor Pump Application VFD to VFDSupply Installation Testing and Commissioning of VFD in existing HSD TW Feeder (110KW) with VFD installed at Paradeep Terminal Scope Includes All necessary Switchgears and items (Relay contactors, SFUs, Fuses, CT, Terminal blocks, lugs control cables, panel dressing and tagging etc) s Wiring Installation Commissioning Parameterization Panel related fabrication Wiring all complete Spray Paint VFD dismantling and handing over adjacent panel wiring for installation of VFD if required etc. VFD SIZE MUST BELOW 839MM x 284MM x 371MM AI 02 atleast AO 02 atleast Current Rating 206.0A (Minimum) at 400V or 415V VFD Multiline control display to be installed outside panel and suitable cable connection to it is in the scope of the bidder.

AI Tender Summary

OUR REF NO 57644328
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 23.14 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Indian Oil Corporation Limited
Work Description Bids Are invited for Vfd For 110 Kw 206A Motor Pump Application - Supply Installation Testing And Commissioning Of Vfd In Existing Fo P19 Feeder 110Kw At Paradeep Terminal. The Feeder Has Soft Starter Installed In It. Scope Includes All Necessary Switchgears And Items Relay Contactors Sfus Fuses Ct Terminal Blocks Lugs Control Cables Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Soft Starter Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Be Below 839Mm X 284Mm X 371Mmai 02 Atleast Ao 02 Atleast Current Rating 206A Minimum At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 75 Kw 145A Motor Pump Application - Supply Installation Testing And Commissioning Of Vfd In Existing Fo P14 Feeder 75 Kw At Paradeep Terminal. The Feeder Has Vfd Installed In It. Scope Includes All Necessary Switchgears And Items Relay Contactors Sfus Fuses Ct Terminal Blocks Lugs Control Cables Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Vfd Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Be Below 722 Mm X 252 Mm X 369 Mm Ai 02 Atleast Ao 02 Atleast Current Rating 145A Minimum At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 37 Kw 73A Motor Pump Application - Supply Installation Testing And Commissioning Of Vfd In Existing Ethanol P4 Feeder 37 Kw At Paradeep Terminal. The Feeder Has Soft Starter Installed In It. Scope Includes All Necessary Switchgears And Items Relay Contactors Sfus Fuses Ct Terminal Blocks Lugs Control Cables Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Soft Starter Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Be Below 636M Mx 203Mm X 57Mm Ai 02 Atleast Ao 02 Atleast Current Rating 73.0A Minimum At 400V Or 45V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 110 Kw 206A Motor Pump Application Ss To Vfd - Supply Installation Testing And Commissioning Of Vfd In Existing Fo P15 Feeder (110Kw) With Soft Starter Installed At Paradeep Terminal Scope Includes All Necessary Switchgears And Items Relay Contactors, Sfus, Fuses, Ct, Terminal Blocks, Lugs Control Cables, Panel Dressing And Tagging Etc S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Soft Starter Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Below 839Mm X 284Mm X 371Mm Ai 02 Atleast Ao 02 Atleast Current Rating 206.0A Minimum At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder. , Vfd For 110 Kw 206A Motor Pump Application Vfd To Vfd - Supply Installation Testing And Commissioning Of Vfd In Existing Hsd Tw Feeder (110Kw) With Vfd Installed At Paradeep Terminal Scope Includes All Necessary Switchgears And Items (Relay Contactors, Sfus, Fuses, Ct, Terminal Blocks, Lugs Control Cables, Panel Dressing And Tagging Etc) S Wiring Installation Commissioning Parameterization Panel Related Fabrication Wiring All Complete Spray Paint Vfd Dismantling And Handing Over Adjacent Panel Wiring For Installation Of Vfd If Required Etc. Vfd Size Must Below 839Mm X 284Mm X 371Mm Ai 02 Atleast Ao 02 Atleast Current Rating 206.0A (Minimum) At 400V Or 415V Vfd Multiline Control Display To Be Installed Outside Panel And Suitable Cable Connection To It Is In The Scope Of The Bidder.
Basic Detail
Tender No GEM/2026/B/8069297
Bidding Type Tender
Location
City Jagatsinghapur
State Odisha
Key Dates
Publish Date 22 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 23.14 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
63ed45f1-b7c3-41e3-adb3-87e613f0ba9e.pdf
chapter_-_3_-_scope_of_work__payment_2026-09-22-16-16-51_442b4145fe18e2e71a3ae642f7e74699.pdf
9930473_Boq_1.xlsx
TechBid_9dc0216a-5f94-45ec-872e1790074919508_opsim2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

63ed45f1-b7c3-41e3-adb3-87e613f0ba9e.pdf

pdf

chapter_-_3_-_scope_of_work__payment_2026-09-22-16-16-51_442b4145fe18e2e71a3ae642f7e74699.pdf

xlsx

9930473_Boq_1.xlsx

pdf

TechBid_9dc0216a-5f94-45ec-872e1790074919508_opsim2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders