Tender For Special Repair To Building No T-24 At Med Regt Under Ge (East) Delhi Cantt-10
Tender Value
48.30 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
14 days left
EMD
96610
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No T-24 At Med Regt Under Ge (East) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified |
| 2 | Dismantling structural steel work including doors,gates ,framed trusses etc complete all as specified & directed |
| 3 | M&L for Mild Steel Framed work such as grills,grating etc with of bar shouldered or riveted or forged into spikes, framed guard bars,barred iron doors,ladders ,framework for water tank conforming to Fe-290 Gde-E-165 complete all as specified & directed |
| 4 | Dismantling timber scantling 40 sqcm & over in section in any position unframed work complete all as specified |
| 5 | M&L for Mild Steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified |
| 6 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 7 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 8 | Material & Labour for Plain Cement concrete type B-0 (1:2:4) using 12.5 mm graded crushed stone aggregate as in seismic and other similar bands, shelves, copings, bed plates, hold fasts, plinth courses,roof kerbs, chajjas, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, filling in pressed steel frame and the like finished fair and even incl necessary form work complete all as specified & directed. |
| 9 | Dismantling wall panelling and ceiling boards/ False ceiling board including snap grid etc (fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified & as directed. |
| 10 | Providing and fixing GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bendingtiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 11 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 12 | M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 13 | Taking down chowkhats with shutter without taking off shutters from the frames of door/windows/ventilator etc (area exc. 1.50 sqm but not exc. 4.00 sqm each) incl making good the disturbed surfaces complete all as specified & directed. |
| 14 | Taking down chowkhats with shutter without taking off shutters from the frames of door/windows/ventilator etc (area not exc. 1.50 sqm each) incl making good the disturbed surfaces complete all as specified & directed. |
| 15 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for joint free glazed coloured ceramic coloured tiles of 300mm x 600mm x 7mm thick on vertical surface of wallsof Class I and laid in pattern as approved by GE set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles, over and including 10mm thick rendering in CM 1:4, all as specified and directed by Engr-in-Charge. |
| 17 | M&L for Mild Steel Framed work as in chowkhats, doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting, purpose made butt hinges, sliding door bolts and tower bolts or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (GdeE- 250) quality a complete all as specified and directed |
| 18 | S&F flush door shutter 35mm thick solid core construction with Block board and plywood face panels, commercial type on both sides. complete all as specified and as directed. |
| 19 | S&F Floor door stopper of aluminium alloy body and tongue,140mm anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed |
| 20 | S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed aluminium (extruded section body) complete all as specified and directed |
| 21 | S&F hat and coat hooks aluminium anodised 200 to 250 mm in width with minimum 6 nos of hooks complete all as specified and directed |
| 22 | S&F anodised aluminium Chowkhat/ frame for doors,windows,ventillators with one or more rebates including joining cleat for fixing etc including powder coating (min thickness of powder coating 50 micron) complete all as specified & directed |
| 23 | M&L for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.), minimum thickness of powder coating 50 microns complete all as specified |
| 24 | S & F 100mm size butt hinges stainless steel complete all as specified and as directed. |
| 25 | S & F 150 mm size aluminium anodised, handles cast type anodised complete all as specified and directed |
| 26 | S & F 150 mm size aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 27 | S & F 250 mm long aluminium alloy, anodised siding door bolts, with has[, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminiums alloy and fixed |
| 28 | S & F stainless steel wire cloth 0.36mm normal dia of wire and average width a apparture 0.56 mm and fixed with tinned tacksor stainless steel wire staples as specified and directed. |
| 29 | S & F 4.8 mm thick sheet glass, tinted of any colour quality and glazed fixed in aluminium framework with necessary fittings and fixtures complete all as specified and directed |
| 30 | M & L 10-12 mm thick polymer modified readymix cement based plaster Make : Ultratech (Brand name Readiplast) complying to IS-1661-1972, IS-2250-1965, IS-2402-1963) or equivalent as approved by GE, applied in ratio as per manufacturer's instructions, on fair faces of brick masonry or concrete surfaces finished even and smooth, including taking down of existing cement or cement lime plaster of any thickness and any description on brick or stone walls including raking out joints, hacking for key and scrubbing down with water, complete all as specified and as directed. |
| 31 | M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of primer and 1mm birla white putty complete all as specified and directed. |
| 32 | M&L for preparation of newly plastered or unplastered wall surfaces and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified |
| 33 | Dismantling stone slab or tiles laid in any type of mortar complete all as specified and directed |
| 34 | M & L for 18 to 20 mm thick granite (of any type) work( table rubbed and polished) in jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab including 10 mm thick screed bed in CM 1:4 including rounding to edge of granite as per required complete all as specified and directed. |
| 35 | M & L for machine cut kota stone slab 20-25 mm thick as in flooring laid over and incl cement screed bed 20 mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and complete all as specified and directed. |
| 36 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement complete all as specified and as directed. |
| 37 | M&L Reinforced cement concrete 1:1½:3 type A1 (using 20mm graded crushed stone aggregate) (nominal mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge |
| 38 | S&F mild steel TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 39 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-charge. |
| 40 | M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc, complete all as specified and directed |
| 41 | M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 42 | Demolition of plain cement concrete in ground floor and paving not exc. 15 cm thick below or above ground level complete all as specified & directed. |
| 43 | Supply and fixing factory made prepolished chequred cement concrete coloured tiles 300mm x 300mm or 22-25mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and incl 20mm thick screed bed in CM 1:6, complete all as specified & directed. |
| 44 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base of floor complete all as specified and directed. |
| 45 | S&F Factory made precast perforated heavy duty drain/ manhole covers including MS frame plate and including reinforcement as per IS 12592 : 2002 with size 1.00mtr x 0.50mtr x 75mm thickness complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains finished even and smooth including use of necessary form work and finishing exposed surfaces even and smooth using cement slurry using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 47 | Material & Labour prepapration of new or previously untreated surfaces of wood or based materials of any description not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint coat over a coat of primer, complete all as spd and as directed. |
| 48 | M&L two coats of synthetic enamel paint over a coat of zinc chrome/red oxide primer including preparation of new or previously untreated steel surfaces over 10 cm in width or girth. |
| 49 | S&F 25 mm thick stainless steel decorative curtain rods including brackets fixed to walls to stainless steel screws complete all as specified and directed |
| 50 | Supply only end funnels/lattoo decorative type complete all as specified and directed |
| 51 | S&F 600 mm x 450 mm bevelled edge looking mirror of selected qualityglass mounted on 6 mm thick AC building board or commercial plywood and fixed with stainless steel screws and cup washers complete all as specified |
| 52 | S&F bevelled edge looking mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed with stainless steel screws and cup washers complete all as specified |
| 53 | Disposal of building rubbish/malba, similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading and disposal at an approved Municipal dumping ground outside Defence land (MoD land), for all leads and all lifts, complete all as specified and as directed by the Engineer-in-Charge.Notes:1. Photographic Evidence: The contractor shall submit clear photographic evidence in support of disposal of building rubbish/malba, similar unserviceable, dismantled or waste materials, indicating the condition of the site before loading, during transportation and after unloading at the approved Municipal dumping ground. The photographs shall preferably be geo-tagged and date-stamped and shall form part of the record for verification and payment purposes. 2. Certification by Engineer-in-Charge: Completion of whole work in this BOQ shall be deemed to have been achieved only after certification by the Engineer-in-Charge that no building rubbish/malba, similar unserviceable, dismantled or waste materials have been left at the site and that the site has been thoroughly cleared and cleaned to his satisfaction. 3. Each load shall comprise a minimum carrying capacity of 5.00 cubic metres (Cum). Payment under this item shall be made on a per-load basis for loads conforming to the above minimum capacity and duly verified by the Engineer-in-Charge. |
| 54 | Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) complete such as switches, light fittings , ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface complete all as directed. |
| 55 | Material and labour of point wiring complete with single core 1.5 Sq mm (nominal area) FRLSH PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm min dia and PVC conduit fittings such as tees, bends, elbow, reducers including cutting & chasing and FRLSH PVC insulated unsheathed 1.5 Sqmm copper conductor mulistranded earth single core wire, connecting to common earth dolly with and incl Metal flush box of suitable size with modular sheet and cover plate (Design and colour as directed by Engineer-in-Charge) for fixing modular switches/ sockets etc. for one light point /fans trolled by one 1-way switch complete all as directed. |
| 56 | Description all as per srl item no. 55.00 here-in-before but with 1.5 sqmm FRLSH copper wire with 1.5 Sqmm FRLSH copper earth wire for one socket outet point 5 amps on the same board. |
| 57 | Description all as per srl item no. 55.00 here-in-before but with 1.5 sq mm FRLSH copper wire with 1.5 Sqmm FRLSH copper earth wire for one socket outet point 5 amps on the independent board. |
| 58 | Description all as per srl item no. 55.00 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for 15 Amp power point. |
| 59 | S & F Modular switch (Shrounded Terminal, Min IP-20 protected) 6 Amp, 1 way, 1 module size complete Design and colour as directed by Engineer-in- Charge. |
| 60 | S & F modular socket (Shrounded Terminal, Min IP-20 protected) two-in-one, 6 Amp universal type, 02 module size complete all as directed. |
| 61 | S & F modular Socket (Shrounded Terminal, Min IP-20 protected), 16 Amp, multipurpose shutter type, 02 module size complete all as directed. |
| 62 | S & F Modular switch (Shrounded Terminal, Min IP-20 protected) 16 Amp, 1 way, 1 module size with indicator lamp complete all as directed. |
| 63 | Supply and fixing in replacement Ceiling rose, insulated body, 3 terminal, 240 volts, etc complete all as directed. |
| 64 | Material and labour for submain wiring in replacement complete with single core 2 x 4.0 sqmm (nominal area) FRLSH, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked and 1 x 4 sqmm as earth wire in and including PVC conduit of size 25 mm dia, medium grade and conduit fitting such as tees, bends, elbow, reducers etc complete all as directed. |
| 65 | Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and not exc 10 sqm on plan for foundations, laying of LT under ground cables/ GI pipes and steel tubular poles etc. and getting out as in soft / loose soil complete all as specified and directed. |
| 66 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete all as specified and directed. |
| 67 | Removal of excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above in starting point. |
| 68 | Supply and spread river sand to required width at bottom and top for cable cushioning all as specified in clause 19.75 of SSR part-I (Note :- thickness of sand will be measured after punning) |
| 69 | Material and labour for GI Tubes of size 40 mm dia light grade, galvanised, with all fitting, laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed. |
| 70 | Supply and lay common burnt bricks of sub class B old size laid at right angle on the cable complete in trenches for cable protection complete all as directed by Engr-in-charge. |
| 71 | S&F XLPE insulated armoured heavy duty U/G aluminium conductor cable served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and overall PVC sheathed of size 50 Sqmm 4 core. Considered for fixing clamping on wall from panel to DB,s connections complete all as directed. |
| 72 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet 10 watt 220 V AC decorative type with driver holder, power coated housing made of aluminium, THD<10%, Frequency 50Hz and lumens efficiency > 120 lm/watt including LED tubelight connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 73 | Supply and fixing in replacement LED light fitting 1X20 W, 220V AC decorative with driver, holder, power coated housing made of aluminium, THD<10%, Frequency 50Hz and lumens efficiency > 120 lm/watt including LED tubelight connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 74 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 75 | S & F 35W High efficient LED Street Light Fitting with pressure die cast Aluminium Housing and Has lenses specially designed for street light with polycarbonate cover. System level efficacy og the Luminaire should more than 100lm/W. The color temperature is around 6500k with a color rendring index of 70. The luminares is IP:66 Protected. it has an electronicdriver complaint to IEC safety standards with a power factor> 0.9, voltage variation range 120-270V, THD<20%, High and Low protection along with a surge protection of 4 KV including provision of 32mm dia GI light grade pipe 1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 76 | Supply and fixing in replacement of street light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed. |
| 77 | Taking down ceiling fan, sealing cable end and removing fan and blades and to be deposited E/M store yard and complete all as specified. |
| 78 | S&F in replacement of MCB DB conforming to IP 530- IK 08 with double door, SPN 16 way 230 Volt double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. (for each qrt 2) |
| 79 | Supply and fixing in replacement of MCB B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed. |
| 80 | Supply and fixing in replacement in replacement of MCB C curve, 10 kA, 63 Amp, SPN with over load and short circuit protection complete all as directed. |
| 81 | S&F of electric Wall mounted 400mm BLDC fan aerodynamically designed resin blades with powder coated guard with flexible ring and oscillation and speed control by pull cord system, connected compete all as specified and directed . |
| 82 | Supply and fixing in replacement of ceiling fan complete with blades, down roads and accessories, 230 volts,1200mm sweep, min air delivery 225 CMM with service value not less than 8.0 BEE star rated with BLDC with remote control for operating complete all as specified. |
| 83 | Supply and fixing in replacement of MCCB incommer Distribution Board (Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as directed. |
| 84 | S & F in replacement of MCCB, 415 volts, three pole of cap125 Amps, 10 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as directed. |
| 85 | Material and labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvinised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender