Public Administrative Department Government Departments Closing in 6 days TDR #57643481

Tender For Repairs And Maintenance & Operations (Armo) Work Of Electrical At Esic Hospital And Dental College Rohini, New Delhi C Us Along With Attached Staff Quarters And Data Centre Along With Provision Of Special Repair Work Of Same On As And When

Issued by Government Departments · Delhi, Delhi
Tender Value
99.82 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
6 days left
EMD
99900
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairs And Maintenance & Operations (Armo) Work Of Electrical At Esic Hospital And Dental College Rohini, New Delhi C Us Along With Attached Staff Quarters And Data Centre Along With Provision Of Special Repair Work Of Same On As And When Required Basis.

BOQ

Name of Work:- Repairs and Maintenance & Operations (ARMO) work of Electrical at ESIC Hospital and Dental College Rohini, New Delhi c us along with attached Staff quarters and Data Centre along with provision of special repair work of same on as and when required basis.
Sl. No. Item Description
12 pair, 0.5 mm dia annealed copper conductor, FRLS PVCinsulated, unarmoured, telephone cable.
23 Pole MCCB, 100 A, 16 KA
33 Pole MCCB, 125 A, 16 KA
43 pole MCCB, 150/160 A, 25 KA
53 pole MCCB, 200 A, 25 KA
63 pole MCCB, 250 A, 25 KA
73 pole MCCB, 315/320 A, 35 KA
83 pole MCCB, 400 A, 35 KA
93 pole MCCB, 630 A, 50 KA
104 pole MCCB, 100 A, 30 KA, IEC CERTIFIED
114 pole MCCB, 125 A, 36 KA, IEC CERTIFIED
124 pole MCCB, 200 A, 36 KA, IEC CERTIFIED
134 pole MCCB, 250 A, 36 KA, IEC CERTIFIED
144 pole MCCB ,400 A, 50 KA, IEC CERTIFIED
154 pole MCCB, 630 A, 50 KA, IEC CERTIFIED
16Aluminium lugs for 6 sq. mm cable
17Aluminium lugs for 10 sq. mm cable
18Aluminium lugs for 16 sq. mm cable
19Aluminium lugs for 25 sq. mm cable
20Aluminium lugs for 35 sq. mm cable
21Aluminium lugs for 50 sq. mm cable
22Aluminium lugs for 95 sq. mm cable
23Aluminium lugs for 150 sq. mm cable
24Aluminium lugs for 185 sq. mm cable
25Aluminium lugs for 240 sq. mm cable
26Aluminium lugs for 300 sq. mm cable
27Aluminium lugs for 400 sq. mm cable
28Supply at Site 7AH 12V DC Battery
29Supply at Site 90/100AH 12V DC Battery
30Supply at Site 150AH 12V DC Battery
31Supply at Site 180AH 12V DC Battery
32Supplying of Remote Control for Window / Split /Cassettee Air-conditioner
33Beetel Landline Phone Modal C-11
34Beetel Landline Phone Modal C-12
35Selector switch voltmeter / ammeter
36Digital Voltmeter 0-500 volt in required size
37Digital Ammeter in required range
38Digital VAF in required range
39Indicator lamp (L.E.D.)
40On-Load Changeover switch 4 pole 100 amp
41On-Load Changeover switch 4 pole 250 amp
42On-Load Changeover switch 4 pole 400 amp
431.5 TR Split Ac Cooling Coil
442 TR Split Ac Cooling Coil
453 TR Cassette Ac Cooling Coil
463 TR Condenser Coil
473 Ton AC Compresor
48Out Door Ac Jali 1.5/2 Ton
49Out Door Fan Blade Split Ac 1.5/2 Ton
508.5 Ton Out Door Motor (Hitachi)
51Cartage @ 1%
52Fixing Charge @ 10%
53OH & CP @ 15%
54ELECTRICAL WORK NDSR ITEM
55Design Fabrication, Supply, Installation, testing and commissioning of cubical typed totally enclosed free standing type dust and vermin proof LT Panel board, fully compartmentalized fabricated from 2mm Thick CRCA sheet steel, approx with following mm depth for incomer and out going with ACB/ MCCB/Change over switch i/c TPN strip type aluminium bus bar of followinf Amps. capacity complete with cable alley , duly powder coated in approved colour suitable for use on 415volt three phase with Neutral, 50Hz. AC Supply, indicating lamps. protection release, metering in coming and out going switch gear removable gland plate on top and bottom and mechanical interlocking with following accessories.
56400mm deep with 200 Amp Aluminium BusBar
57400mm deep with 400 Amp Aluminium BusBar
58800mm deep with 1200 Amp Aluminium BusBar
59800mm deep with 2000 Amp Aluminium BusBar
60Supply and fixing of following capacity ACB with new Air circuit breakers with LCD display and LED fault indication, LSIN+G protection release for adjustable OC, SC & EF protection, Instantaneous protection & over temp. protection ,ZSI, UV coil suitable for operation on 415 volt, 3 ph , 50 Hz ac supply , horizontal draw out , motorized , inbuilt thermal memory , 4 Nos NO/NC auxiliary contacts, double isolation features , in the existing LT panel i/c dismantling and modifying the chamber as per new ACB's making & reconnection of main incoming cables , modification of front cover/ door of ACB's compartment rewiring the control wiring of Metering & electrical interlocking as reqd. or any other related work to make it complete with the existing system etc. complete as reqd.
611600 A ,Three pole, 50 kA breaking capacity
621000 A ,Three pole, 50 kA breaking capacity
63SH-X : Maintenance of Sub-Station and Main Boards
64Servicing of Sub-station
65Cleaning, decarbonising and demoisturising the highly carbonised 11KV, HT panel board due to flash occurred, cleanig its enclosure, bus bars, fixed shutter, front and rear spout grid by opening the bus bar & CT's chamber, removing the carbon with CTC/CRC-2-26 and thinner, checking, cleaning & decarbonising the bus bar, fixed contacts of swithgear with CTC/CRC & tightening of contacts & joints of bus bars i/c replacing the old burnt HT taping & HT compound, tightening of cable end terminations, replacement of burnt/heated thimbles, nut bolts etc. wherever reqd. testing etc complete as reqd.
66High Voltage testing of 11KV HT Panal Board /cable (of size 3X300 / 3X240 sqmm) by injecting High Voltage with the help of suitable HV testing Kit for ensuring thehealthyness of cable.
67Servicing of 11KV, 400Amp, 350MVA, 3phase, metal clad bulk oil circuit breaker complete with removal from the HT panel board, dismantling / opening the required parts for servicing, checking, cleaning, testing & rectification of defects, oiling, greasing, assembling, dehydration & filteration of oil etc.complete as reqd.
68Servicing of 11KV, 630/ 800Amp, 350MVA, 50Hz, 3phase, horizontal draw out and horizontal isolation type All make vacuum circuit breaker (VCB) complete with removal from the HT panel board, dismantling / opening the required parts for servicing, checking, cleaning, testing & rectification of defects if any, setting right of main contacts, moving contacts, tripping and closing mechanism, oiling, greasing, assembling etc. complete as reqd.
69Servicing of upto 1600 Amp rating, 415/500 Volts, withdrawable type, 3 phase, 4 wire, 50 Hz, AC supply, L&T/GE/ABB make Air Circuit Breaker complete with removal from the panel board, opening/dismantling the required part, servicing, checking, cleaningand reassembling the same complete as reqd.
70Testing & calibration of All make IDMT relay set having 2Nos. O/C & 1No E/F element by secondary injection method,cleaning the contacts, resetting with required accuracy complete with checkingand set right the wiring etc complete as reqd.
71Testing of the complete system of HT panel for checking the actual working of the CTs, their wiring, connected IDMT relay, shunt trip system, breaker's tripping system and for any loose connection by primary injection method in all three phases and at each plug setting at actual time multiplier at site with suitable testing equipment i/c rectify the diffect in control wiring etc if any, complete as required.
72Fault location pin point of under ground 11KV HT/1.1KV LT cable upto length of 200mtr by high voltage surge injection with the help of fault location machine equipped with lap-top and other necessary equipments, tool & tackels etc complete as required.
73Providing & fixing power pack unit for protection and indication system of 11 KV HT Panel suitable for 110Volt DC output with 220/110 volt AC input supply, protection fuse on input as well as on output i/c connecting on HT panel board testing, commissioning etc complete as reqd.
74Annual Maintence & Servicing, checking, cleaning, testing of Upto 1000 KVA Transformer oil type & rectification of defects if any and chacking oil and topping up etc. complete as reqd. ( Cost of components used to paid extra )
75Dehydration, filtration and testing of the transformer oil of existing equipment by portable filtration plant at site including conducting dielectric test and recording the results in the presence of ESIC representative. The dehydration will be continued till required results are obtained for transformer/OCB complete as required.
76Supplying and filling of New dehydrated Transformer oil in existing equipment at site during dehydration process fortopping up etc. complete as required.
77Annual Maintence & Servicing, checking, cleaning, testing of All LT Panel Board & rectification of defects if any etc. complete as reqd. ( Cost of components used to paidextra )
78SH-XI : Maintenance of Air-conditioning system andPumps
79Annual Comprehensive Repair and Maintenance of Split type Air Conditioners of 1/1.5/2 TR rating. CAMC including Gas charging whenever required, servicing, and Repair of motor, fan ,relay & capacitor replacement etc for smooth operation complete. ( any other part need to replace costpaid extra )
80Annual Comprehensive Repair and Maintenance of Window type Air Conditioners of 1/1.5/2 TR rating. CAMC including Gas charging whenever required, servicing, and Repair of motor, fan ,relay & capacitor replacement etc for smooth operation complete. ( any other part need toreplace cost paid extra )
81Supplying, Installation, Testing & commissioning of Compressor of 1.5/2 TR Split / Window type Air- Conditioner including charging of R22 Gas complete asrequired.
82Annual Comprehensive Repair and Maintenance of Package/ Cessetee type Air Conditioners. CAMC including Gas charging whenever required, servicing, and Repair of motor, fan ,relay & capacitor replacement etc for smooth operation complete etc as required. (Any other part need to replace cost paid extra )
83a) 2 TR capacity
84b) 3 TR capacity
85c) 5 TR capacity
86d) 8 TR capacity
87Supplying, Installation, Testing & commissioning of Compressor of following capacity package / cassattee type Air-Conditioner including charging of refregerent Gascomplete as required.
88a) 2 TR capacity
89b) 3 TR capacity
90c) 5 TR capacity
91d) 8 TR capacity
92Replacement of PCB follwing type Air-Conditioner as persatisfaction of Engineer in Charge.
93PCB 1.5 TR Spilt/Window type Air-Conditioner
94PCB 2 TR Package/Cassatte type Air-Conditioner
95PCB 3 TR Package/Cassatte type Air-Conditioner
96PCB 5 TR Package/Cassatte type Air-Conditioner
97PCB 8 TR Package/Cassatte type Air-Conditioner
98PCB 1.5/2 TR Split/ Window Inverter type Air-Conditioner
99Supplying and fixing of Copper piping of size 1/4 inch &5/8 inch with insulation, jointing and testing complete as required.
100Supplying and fixing of Copper piping of size 3/8 inch & 5/8 inch with insulation, jointing and testing complete asrequired.
101Supplying and fixing of PVC Braided semi-felxible of size 25 mm OD with insulation, jointing and testing complete asrequired.
102Supplying and fixing of 4 sq mm X 4 core PVC insulated PVC sheathed copper conductor cable for air-conditioner, connection, testing complete as required.
103Annual Comprehensive Repair and Maintenance of Water Cooler i/c replacement of drain pipes, Gas Charging, replacement of relays, timers, thermostat checking of current drawn to known the healthy condition including chemical service & wet service etc. as required. Checking Firmness of supporting arrangement for the blower, motor, Painting of the MS portion prone to rusting etc. The history sheet of servicing/breakdown repairing of each and every unit shall be maintained. Cleaning of water coolers on weekly basis. The cleaning / minor repair of stabilizers shall be covered under the AMC contract. The copy of report shall be submitted along with the bill complete as required. but excluding replacement of PCB/ control panel and Compressor and Condenser /Cooling coil and Replacement of MS/PVC/SS body etc.
104Annual Comprehensive Repair/Maintenance of Refrigerator/Deep freezer i/c comprising of replacement of any or all parts of Refrigerator like switches, bulb, cables, wires, drain pipes, Gas Charging ,replacement of relays, timers, thermostat & checking of current drawn by each refrigerator to known the healthy condition. The comprehensive service would include chemical service & wet service etc. as required. Checking Firmness of supporting arrangement for the blower, motor, casing, Painting of the MS portion prone to rusting etc. The history sheet of servicing/breakdown repairing of each and every unit shall be maintained. The copy of report shall be submitted along with the bill subsequent to the servicing activity. The cleaning/ minor repair of stabilizers shall be covered under the AMC contract. but excluding replacement of PCB/ control panel and Compressor and Condenser Cooling coil and Replacement of MS/PVC/SS body etc.
105Annual Comprehensive maintenance contract for UV Water Purifier of all types including replacement of all parts as & when required, Periodical, preventive and breakdownmaintenance
106Supplying, Installation ,Testing & Commissioning offollowing capicity Pump Motor set with all other accessories etc complete as required.
1073 HP Three Phase mono block pump motor set.
1085 HP Three Phase mono block pump motor set.
10910 HP Three Phase mono block pump motor set.
1109.5KW, Three Phase, Swarege Submersible pump set
111Repairing and servicing of following HP water pump motor set including changing the worn-out parts, Machining, greasing, oiling, alignment, testing etc. complete as required. (Cost of components used to paid extra as below)
1122/3 HP Three phase pump set.
11310 HP Three phase pump set.
114Replacement of following worn-out Spare parts etc.complete as required.
115Providing Shaft made out of EN 8 material.
116Providing Neck-Ring
117Providing Mechanical Seal
118Providing Mechanical Seal plate
119Providing Shaft Sleeve
120Providing Ball Bearing of Pump
121Providing Ball Bearing of Motor
122Providing Stud / Bolt with nut and washer
123Rewinding of motor 3 HP pump
124Rewinding of motor 10 HP pump
125Lifting and lowering of submersible pump set of borewell and increasing depth of suction pipe complete as required.
126Supplying & installation of following capacity Motor starteri/c testing complete etc as required.
1271.5 to 7.5 HP DOL Motor Starter
128SD Starter7.5 HP to 15 HP
129SH-XII-A(Fire Fighting System)
130Testing, Refilling of following type fire extinguisheretc complete as required
131Testing, Refilling of carbon dioxide (CO2) type fireextinguisher capacity 22.5 kg.
132Testing, Refilling of carbon dioxide (CO2) type fireextinguisher capacity 4.5 kg.
133Refilling of carbon dioxide (CO2) type fire extinguishercapacity 2 kg.
134Refilling of ABC type fire extinguisher capacity 6 kg.
135Refilling of ABC type fire extinguisher capacity 4 kg.
136Refilling of Water-CO2 type fire extinguisher capacity9 kg.
137Refilling of M-Foam type fire extinguisher capacity 9 Litres.
138Refilling of M-Foam type fire extinguisher capacity 50Litres.
139Hydraulic pressure testing of all types fire extinguisher asper IS:2190:2010 as required.
140Supplying, & fixing of mounted photo luminescent signage's on 2mm thick aluminium sheet, non toxic. Non-radioactive,maintenance free self glowing safety signage's comprising of supplied chargeable crystals to glow in the dark with high intensity luminous 2mm aluminium sheet prpoperties by chemical coated (venial & tap not accepted) and covered with V protection layer printed inmuli in bilangual language ad graphic symbol as per requirement etc as required.
141Single side
142Double Side
143Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
14416 Zone
14520 Zone panel for fire alarm system
146Servicing contract for Fire Fighting Diesel Engine and replacement of all filter, gasket and Engine oil etc complete Engineer visit at every month / when required for smooth running of Engine during the contract period etc. completeas reqd.
147Servicing contract for Fire Fighting pumps, Drinking water pumps and Sewerage pump sets and electrical panel and replacement of defective parts etc complete Engineer/ Mechanic visit at every week and when required for smooth running of Engine/Pump & Motor during the contract period etc. complete as reqd. (Cost of components used to paid extra )
148Servicing contract for Fire Alarm system and PA System and replacement of defective parts etc complete Engineer visit at every week / when required for smooth working of AFA System & PA System etc during the contract period etc. complete as reqd. (Cost of components used to paidextra )
149Cartage @ 1%
150OH & CP @ 15%
151SH-XII-B (Fire Alarm and Fire Fighting System)
152Provinding laying , testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like ebbows , tees , flanges , tapers , nuts bolts, gaskets etc. in ground including welding , excavation & providing cement concrete blocks as supports , anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes comlete as required .
153150mm. Dia
154Provinding laying , testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 3589/IS 1239 including welding , fittings like elbows , tees , flanges, tapers, nuts bolts, gaskets etc . Fixing the pipe on the wall/ceiling with suitable clam/support frame and painting wih two or more coats of synthetic enamel paint of required shade comlete as required .
15580 mm dia
156100 mm dia
157150 mm dia
158Supplying and fixing Single headed internal hydrant valve with instantaneous Gunmetal/stainless steel couplingof 63 mm dia with cast iron wheel, ISI marked conforming to IS 5290 (Type - A) with blank Gunmetal/stainless steel capand chain as requried :
159Single headed Stainless Steel
160Supplying ,fixing testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as requried :
16140 mm dia
16250 mm dia
16365 mm dia
16480 mm dia
165100 mm dia
166150 mm dia
167Supplying ,fixing testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of followingsizes as requried :
16880 mm dia
169100 mm dia
170150 mm dia
171Providing , installation , testing and commissioning of non- return valve of following sizes conformig to IS : 5312 complete with rubber gasket , GI bolts , nuts , washers etc .As required :
17240 mm dia
17350 mm dia
17465 mm dia
17580 mm dia
176100 mm dia
177125 mm dia
178150 mm dia
179Supplying and fixing 63 mm dia , 15 m long RRL Hose pipe with 63mm dia male female couplings duly bound with GI wire , rivets etc. conforming to IS 636 (type-A) as required
180Stainless Steel (Grade 304)
181Supplying and fixing first-aid hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS : 12585
18220 mm nominal internal gunmetal globe valve & nozzle. Drum and brackets for fixing the rquipmentson wall.Connections from riser with 25 mm dia stop gun metal valve& M.S. pipe and socket
18340 M.
184Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal interanl diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
185Stainless Steel
186Supplying and fixing of fire brigade connection of cast iron body with gunmetal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection confoming to IS 904 as required :
1872 way-100 mm dia M.S. pipe
1884 way-150 mm dia M.S. pipe
189SH-XIII (Fire Alarm System)
190Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
191Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete withall connections etc. as required.
192Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push buttonetc. as required.
193Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. asrequired.
194Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted inM.S. box (16 SWG) with hinged cover plate & suitable foroperation with amplifier i/c line matching transformer etc. complete as required.
195MAN POWER)
196Diploma in Fire l Engineering with 10 years experience (Supervisory) in Maintenance Job
197Fire safety diploma with 10 years exerience (Highly skilled) (Oertation & Maintenance)
198Fire safety diploma with 10 years exerience (Highly skilled) (Oertation & Maintenance)Reliever
199Skilled with ITI/Diploma 3 yrs. exeperience
200Skilled/ Trade certificate with 3 yrs experience in lift maintenance & operation
201Skilled/ Trade certificate with 3 yrs experience in lift maintenance & operation.(reliever )
202Skilled/ITI certificate with 3 yrs.
203Skilled/ITI certificate with 3 yrs. (Reliever )
204Skilled/ Trade certificate with 3 yrs experience in EPBAX maintenance & operation
205Total Amount for 6 Months Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57643481
AUTHORITY Government Departments
TENDER VALUE 99.82 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Uttar Pradesh Small Industries Corporation Limited
Work Description Tender for Repairs And Maintenance & Operations (Armo) Work Of Electrical At Esic Hospital And Dental College Rohini, New Delhi C Us Along With Attached Staff Quarters And Data Centre Along With Provision Of Special Repair Work Of Same On As And When Required Basis.
Basic Detail
Tender No 100/SE/26-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 22 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 99.82 Lakhs
Tender Fee 2360
EMD 99900
Exemption Not Available
Document List
BOQ_2239820.xls
e01263a2-1e59-425e-92ca-2c88df6a61f2.html
NITESICHospitalRohiniNewDelhi.pdf
Tendernotice_1 (76).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2239820.xls

html

e01263a2-1e59-425e-92ca-2c88df6a61f2.html

pdf

NITESICHospitalRohiniNewDelhi.pdf

pdf

Tendernotice_1 (76).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders