Tender For Electrical Work At Sahitya Kala Parishad, 3Rd Floor, Delhi Archives Building, New Delhi
Tender Value
2.33 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
0 days left
EMD
4671
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Work At Sahitya Kala Parishad, 3Rd Floor, Delhi Archives Building, New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 4 sq. mm |
| 3 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | 25 mm |
| 5 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 6 | 8 way (4 + 24), Double door |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 8 | 12 way , Double door |
| 9 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 10 | 12 way (4 + 36), Double door |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 12 | Single pole |
| 13 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 14 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 16 | 400 A, 35 KA,TPMCCB |
| 17 | 250 A, 35 KA,TPMCCB |
| 18 | 100 A, 16 KA,TPMCCB |
| 19 | Digital Ammeter Three phase |
| 20 | Digital Volt Meter Three phase |
| 21 | LED type indicating light (RYB) |
| 22 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required |
| 23 | 5/6 amps switch |
| 24 | 3 pin 5/6 A socket outlet |
| 25 | 15/16 A switch |
| 26 | 6 pin 15/16 A socket outlet |
| 27 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 28 | 15/16 A Switch |
| 29 | 6 Pin 15/16 A Socket Outlet |
| 30 | Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 31 | 6 Module (200mmX75mm) |
| 32 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 33 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 34 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 35 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 36 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 37 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. |
| 38 | 3 X 10 sq. mm (22mm) |
| 39 | 4 X 50 sq. mm (35mm) |
| 40 | Replacement of floor mounting compartmentalized cubical panel board minimum 400 mm depth with locking arrangement front openable, totally enclosed, dust & vermin proof fabricated out of 2mm thick cold rolled carbon annealed, sheet steel, with suitable incoming Amp 4 strip Al. bus bar, cable alley on both sides, powder coated paint of approved shade and 2 nos 25x5mm copper strips throughout the width of panel consisting of two earth studs on each strip complete with following incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing 50mm X 50mm X 6 mm thick Angle base upto 300 mm above ground level including necessary grouting / fixing on floor ( Drawing shall be got approved from Engineerincharge before fabrication(all MCCB's shall have spreader link & rotory handle) complete etc as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer