Tender For Renovation Works At Fire Research Lab In The Cbri Institute..
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Sep 2026
4 days left
EMD
12800
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Works At Fire Research Lab In The Cbri Institute..
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 2 | 12 mm cement plaster of mix :1:6 (1 cement: 6 Fine sand) |
| 3 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth completed) |
| 4 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 5 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) |
| 6 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 7 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade one or more coat on old work. |
| 8 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 9 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 10 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 11 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge :Pre-laminated particle board with decorative lamination on both sides |
| 12 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 13 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 14 | Providing and fixing aluminium tower bolts, ISI marked, Powder coated,required colour or shade, with necessary screws etc. complete : 200x10 mm. |
| 15 | Providing and fixing aluminium sliding door bolts, ISI marked, Powder coated , required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 16 | Providing and fixing aluminium handles, ISI marked, Powder coated, with necessary screws etc. complete : 125 mm |
| 17 | Wiring for light Point /fan point /exhaust fan /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch of Legrand Myrius/ Havells crabtree Athena make ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable Havell’s/ Finolex/Polycab/ KEI make including ceiling rose,etc as required. Group C |
| 18 | Wiring for circuit /sub-main wiring along with earthwire with the following size of FRLS PVC Insulated copper conductor single core cable of Havell’s/ Finolex / Polycab make ISI Marked in surface/ recessed steel conduit as required |
| 19 | 2x2.5 Sq mm + 1x2.5 Sq mm earth wire |
| 20 | 2 x 4 sq mm + 1 x 4 sq mm earth wire |
| 21 | 2 x 6 sq mm + 1 x 6 sq mm earth wire |
| 22 | Supplying & Fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate. As required. |
| 23 | Supplying & Fixing Suitable size GI box with modular plate and cover in front on surface or in recess , including providing & Fixing 3pin 5/6 A modular socket outlet and 5/6 AmModular switch of ISI marked , connections etc as required. |
| 24 | Supplying & Fixing Suitable size GI box with modular plate and cover in front on surface or in recess , including providing & Fixing 6pin 5/6 and 15/16 A modular socket outlet and 15/16A modular switch of ISI marked , connections etc as required. |
| 25 | Supplying and fixing 5A to 32A rating, 240V/415V , 10kA,\\"C\\" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | 32A SP MCB |
| 27 | Supplying and fixing 8 way,Double Door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | Supplying and fixing of Wall Mounted Fan 400mm sweep for Orient/ Havells/ Bajaj/ Philips or its equivalent make. |
| 29 | Supplying and fixing of 30W LED batten square light of Havells/ Orient/ Philips or its equivalent make. |
| 30 | Supplying and fixing 32 A, 240 V, SPN Industrial typesocket outlet, with 2 pole and earth, metal enclosedplug top along with 32 A \\"C\\" curve, SP, MCB, in sheetsteel enclosure, on surface or in recess, with chainedmetal cover for the socket out let and complete withconnections, testing and commissioning etc. as required. |
| 31 | Supplying & Fixing of 230mm sweep double ball bearing type metal body four blade Exhaust Fan make of Havells/ Crompton / Bajaj / Orient or its equivalent in all respect as required and directed by engineer incharge |
| 32 | Supplying and fixing 63A, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 33 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensingcontrol IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature)with wall mounted stabilizer of 130-280V Input & Output 210-230 range of capacity 5KVA or Sutaible Upto 2T AC:-Inverter Type Cooling Only(make LG/ Voltas/ Samsaung/Hitachi ot its equivalent) 1.5 TR with 5 Star BEE Rating Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender