Housing Urban and Rular Development Government Departments Closing in 3 days TDR #57642301

Tender For Rewiring And Renewal Of Worn Out Electrical Installations In Govt . Primary Health Centre At Velur, Perambalur District.

Issued by Government Departments · Perambalur, Tamil Nadu
Tender Value
4.45 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
3 days left
EMD
4500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Perambalur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Rewiring And Renewal Of Worn Out Electrical Installations In Govt . Primary Health Centre At Velur, Perambalur District.

BOQ

Name of Work:- Rewiring and renewal of worn out electrical Installations in Govt . Primary Health centre at Velur, Perambalur district.
Sl. No. Item Description
1Rewiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigidpipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colourfor open PVC light point / fan point (for electronic regulator) (5 points per coil)
2Renewal by Supply and fixing of 20W, 4 feet LED fitting with LED tube on a SBT fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting. (Higher End)
3Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with stepped electronic 300W regulator (Higher end) with 600 mm down rod on the existing fan clamp.
4Renewal bysupply and fixing of 400mm wall mounting fan with necessary clamp on wall with suuitable connection.
5Renewal by Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
6Supply and fixing of louvers shutters arrangements for 300 mm (12\\") sweep (light duty) AC exhaust fan.
7Renewal by Supply and fixing of 6 Nos flush type switches in existing TW box covered with suitable hylem sheet.
8Renewal bySupply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End.
9Renewal by Supply and fixing of 1 no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch , 1 no. 16A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End.
10Renewal by Supply and fixing of 2 nos.6A two module socket , 1 no. 6/16A two module socket , 2 nos. 6A one module switch, 1 no. 16A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End
11Renewal by Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug)
12Renewal by Supply and fixing of 32A DP pole MCB with suitable DP sheet steel enclosure box on wall with nacessary earth connection.
13Renewal by Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 12 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End.
14Renewal bySupply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitablecolour.
15Renewal by Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with continuous earth wire connection 1.5 sq.mm copper wire with painting of suitable colour.
16Renewal by Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigd pipe on wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire with painting of suitable colour.
17Renewal by Supply and erection testing, commissoning uninterrupted power supply (UPS) OFF LINE sine wave with copper wound transformer of 2000 VA input supply of 230V-50Hz AC supply with 150 AH tubular Battery to work at full load capacity back up of 1 hour including transportation with following specification.1.Input voltage: 230, 50HZ single phase AC supply.2.Output voltage: 220V to 240V 50HZ AC supply3. Battery charging device fo suitable rating4. circuit board of suitable capacity. 5. Over load and short circuit protection6. Visual Indication for ON/ OFF /TRIP battery charging/ mains failure/ low battery etc., 7. Mode setting for bypass/ Reset. 8. 12 V AC / 150AH Battery - 2 No. 9. Trolly for heavy ups & battery.
18Renewal by Supply, Erection, testing and Commissioning of 1.5 TR (6000K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Non CFL compressor operating on refrigerant suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with three Star rating as per BEE Specification Five Star Rated and capable of performing the following functions.(A) Cooling (B) Dehumidifying (C) Air Circulating. (D) Filtering.The installation work for the above split type AC units includes the following.1. Mounting / fixing indoor and outdoor units at their respective locations. 2. Laying refrigerent pipe line of 6mtrs. Length, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polyurthelene foam 5mm thick tubing.4. Laying 25mm dia flexible PVC drain pipe of 6mts. Length to drawn out the condensate water being formed in the indoor unit.5. Leakage testing the entire gas unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided 3 core with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make - Carrier / Voltas / Blue Star make only)
19Renewal by Supply and Erection of 4 KVA electronic automatic Voltage stabilzer with input range of 170V-270V and output range of 200-240V with high / low cut off 3 minutes time delay relay with demonstration suitable for operation on 230V/50HZ single phase AC supply.(V-GUARD/syscom/equ)
20Renewal by Supply and fixing of MS stand for fixing outdoor unit.
21Renewal by Supply and laying of 5/8\\" and 3/8\\" copper pipe.
22Supply and clarnping of 3-1/2 x 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
23Renewal by Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection.
24Renewal by Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable withnecessary aluminium cable sockets by crimping etc with electrical connection complete.
25Renewal by supply and fixing of 100W LED Flood light fitting on the existing post/ on wall with PVC unsheathed copper leads with MSclamps and with painting.
26Renewal by supply and fixing of 70W LED Flood light fitting on the existing post/ on wall with PVC unsheathed copper leads with MSclamps and with painting.
27Renewal by Supply and fixng of TNEB meter board suitable for 3phase 63A service connection made up of suitable angle iron frame work of size 2feetx1-1/2feet usingangle ironof size1-1/2\\"x1-1/2\\"x1/4\\"rigidly fixed on wall covered with hylem sheet of size 2feet x 1/2feetof 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos. 63A fuseunits (500V),1No.neutral link, copperearth flat of size 1\\"x1/4\\" with interconnection of EB meter tofuse unitsby 16 Sq.mm PVC insulated copper wire with 1No 63Amp 30MA Four Pole RCD/RCCB(HigherEnd)withsuitable necessary connection with earth connection complete.
28Renewal by Supply and Laying of 2x16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
29Renewal by Supply and clarnping of 2 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
30Renewal by Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection.
31Renewal by Supply and fixing of 1000W automatic electric water heater of 25litres capacity suitable for 230V 50c/s AC supply onsuitable MS clamps with 3 core flex wire,but without plumbing work.
32Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
33Renewal by Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
34Less credit
35GST @ 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57642301
AUTHORITY Government Departments
TENDER VALUE 4.45 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Rewiring And Renewal Of Worn Out Electrical Installations In Govt . Primary Health Centre At Velur, Perambalur District.
Basic Detail
Tender No TN.No. 3 2026-27 Dt 17.09.2026
Bidding Type Tender
Location
City Perambalur
State Tamil Nadu
Key Dates
Publish Date 22 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 4.45 Lakhs
Tender Fee Ref. Documents
EMD 4500
Exemption Not Available
Document List
773c4bc2-ff5a-430b-94cd-972545e7cc57.html
BOQ_849403.xls
PHCvelurperambalur.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

773c4bc2-ff5a-430b-94cd-972545e7cc57.html

xls

BOQ_849403.xls

pdf

PHCvelurperambalur.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender