Tender For Construction Of Evm & Vvpat Storage Warehouse At Reasi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Oct 2026
18 days left
EMD
7.83 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Evm & Vvpat Storage Warehouse At Reasi
BOQ
| Sl. No. | Item Description |
| 1 | SECTION A — BUILDING WORKS |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal) crushed. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams,suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level TheRmto-Mechanically Treated bars of grade Fe-500D or more. @175 kg/cum |
| 9 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 10 | Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square meter on damp proof courses after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 14 | Columns, pillars, piers, abutments, posts and struts. |
| 15 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Suspended floors, roofs, landings, balconies and access platfoRmts. |
| 17 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 18 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 mtr. of part thereof (Plan area to be measured). Suspended floors, roofs landing, beams and balconies |
| 19 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 20 | Extra for brick work in super structure above plinth level upto floor V-level. |
| 21 | Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Extra for half brick work in super structure above plinth level upto floor V-level. |
| 23 | Extra for providing and placing in position 2 Nos 6mm dia M.S Bars at every third course of half brick masonary — Qty vide item no. |
| 24 | Tile brick masonry with common burnt clay tile bricks of class designation 10 in foundation and plinth including curing complete in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 25 | Extra for tile bricks masonry with common burnt clay tile bricks in superstructure above plinth level upto floor five level. |
| 26 | Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 27 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound Confirming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 28 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg./sqm. and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured. |
| 29 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 30 | 15mm Cement plaster on rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 31 | 6mm Cement plaster to ceiling of mix:1 : 3 ( 1 cement : 3 fine sand) |
| 32 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. |
| 33 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete. |
| 34 | Add or deduct for plaster drip coarse / groove in plastered surface of moulding to RCC projections. |
| 35 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 36 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 38 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and Confirming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) Confirming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 39 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 40 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality Confirming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 41 | Providing and fixing of Description factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles duly einforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll foRmting process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket,stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall,plastic packers, plastic caps and ecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 42 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, |
| 43 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 44 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 45 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture |
| 46 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class Sal wood |
| 47 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter Confirming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately). 12 mm thick pre-laminated particle board (decorative lamination on one side and other side balancing lamination) grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848 and prelaminated Confirming to IS: 12823, Grade-I, Type-II marked : |
| 48 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) — 84 |
| 49 | Providing and fixing aluminium harware fittings — Aldrop with lock (NSI) |
| 50 | Providing and fixing aluminium harware fittings — Tower bolt 150mmx10mm |
| 51 | Providing and fixing aluminium harware fittings — Handle 125mm |
| 52 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 53 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 54 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floo rfinishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With Stainless Steel cover plate minimum 1.25 mm thickness. |
| 55 | 150x10mm. — 150x10mm. |
| 56 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm |
| 57 | Providing and fixing ISI marked oxidized M.S. door latches Confirming to IS : 5930 with screws etc. 300x20x6 mm |
| 58 | Providing and fixing aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper. |
| 59 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes Confirming to IS : 13592 Type B including jointing with seal ring Confirming to IS : 5382 leaving 10mm gap for theRmtal expansion. Single socketed pipes of 110mm diameter. |
| 60 | Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes Confirming to IS : 13592 Type B including jointing with seal ring Confirming to IS : 5382 leaving 10mm gap for thermal expansion |
| 61 | Coupler 110mm. |
| 62 | Single tee with door 110 x 110 x 110mm. |
| 63 | Bend 87.5* 110mm. |
| 64 | Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @0.90litre/10sqm over anunder coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 65 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes Confirming to IS: 15801, UV stabilized and anti-microbial fusion welded, having theRmtal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. — PN-16 pipe, 25mm OD(SDR-7.4) |
| 66 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes Confirming to IS: 15801, UV stabilized and anti-microbial fusion welded, having theRmtal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. — PN-16 pipe, 32mm OD(SDR-7.4) |
| 67 | Supply, installation, testing and commissioning of gunmetal, male or female threaded isolation control valve of approved quality confiRmting to IS 778, PN 10, with necessary specials, unions, nipple etc., — 25mm dia (NSI) |
| 68 | Supply, installation, testing and commissioning of gunmetal, male or female threaded isolation control valve of approved quality confiRmting to IS 778, PN 10, with necessary specials, unions, nipple etc., — 32mm dia (NSI) |
| 69 | Providing and fixing PPR Unions — PPR Union 32mm |
| 70 | Providing , fixing & laying G.I. pipes Medium type complete with G.I. fittings and clamps, incluing trenching and refilling (external work) — 25mm dia |
| 71 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings. Flat back wash basin of size 630x450 mm. |
| 72 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 73 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms. |
| 74 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 75 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) Confirming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 76 | Providing and fixing mirror of superior glass( of approved quality) and of required shape and size with plastic . moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm. |
| 77 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 78 | Providing & Fixing C.P. Single hole mixer for wash basin. |
| 79 | Providing & Fixing C.P. wall mixer of approved make including cutting and making good the walls wherever required (NSI) |
| 80 | Providing & Fixing C.P. tubes of approved make 450mm to 600mm long (NSI) |
| 81 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality Confirming to IS standards and weighing not less than 690 gms |
| 82 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make Confirming to IS : 8931 |
| 83 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. — 4 |
| 84 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Pipe 100mm (NSI) Type B |
| 85 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Floor trap 100mm (NSI) |
| 86 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Door T 100mm (NSI) |
| 87 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Collars 100 mm (NSI) |
| 88 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Reducer 100 x 50mm (NSI) |
| 89 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Pipe 75mm (NSI) |
| 90 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Floor trap 75mm (NSI) |
| 91 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Door T 75mm (NSI) |
| 92 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Collars 75 mm (NSI) |
| 93 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Pipe 50mm (NSI) |
| 94 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — Cone covel 50mm (NSI) |
| 95 | Providing and fixing P.V.C. pipe and pipe fittings of the following nominal dia to P.V.C. Soil/Waste/Ventilating pipes, excluding cost of holder-bats. — PVC waste pipe |
| 96 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 97 | Providing and fixing of master trap of approved quality and make.(NSI) |
| 98 | Providing and fixing of 6-layer water storage tanks of approved quality and make. |
| 99 | Structural design and preparation of Drawings including vetting from DIQC/IIT/NIT and soil testing as per directon of Engineer-In-Charge. |
| 100 | Carriage of materials by Mechanical Transport including loading, unloading and stacking, Sand Aggregate Average lead of 35 Km |
| 101 | Carriage of materials by Mechanical Transport including loading, unloading and stacking, Stone Aggregate Average lead of 10 Km |
| 102 | Carriage of materials by Mechanical Transport including loading, unloading and stacking. Bricks Average lead of 85 Kms |
| 103 | SECTION B — ELECTRICAL WORKS |
| 104 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in Existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 105 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 106 | 25mm. |
| 107 | 32mm. |
| 108 | 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE. |
| 109 | 2 X 4.0 SQ.MM + 1 X 4 SQ.MM EARTH WIRE. |
| 110 | 2 X 16.0 SQ.MM + 1 X 6 SQ.MM EARTH WIRE. |
| 111 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 112 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 113 | Supplying and fixing following way, single pole TPN DB and neutral, sheet steel, MCB distribution board 2 rows , 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 114 | 8 way , Double door TPN |
| 115 | 12 way , Double door SPN |
| 116 | Supplying and fixing 5amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 117 | Single pole |
| 118 | Single pole and neutral |
| 119 | Supply and fixing following rating double pole 240V Isolator in the existing MCB DB Complete with Connections, Testing and commissioning as required |
| 120 | 63Amp |
| 121 | SITC of pre-wired Surface / Recess Mounted LED Down Light 18 Watts W including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required . |
| 122 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 123 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 124 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 125 | SITC 250mm Exhast Fan Including all accessories & Fitting |
| 126 | 1200mm sweep BLDC Ceiling Fan Including all accessories & Fitting |
| 127 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. The arrangement is t obe provided with 6sqmm ( green) cu wire from earthing rod to main board. |
| 128 | Supplying and laying 25 mm x 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ teRmtinating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 129 | SITC 50 Ltrs water Heater |
| 130 | Supplying,Installation,Testing and Commissioning of Cubical Outdoor Type LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars, CT / PT/Meters all accesoriesetc. as required as per the Following Description.(IP:42)(SMDB-HS-GF) Incuding Everything |
| 131 | INCOMER MCCB 63 Amps 4 P (1 Nos), OUTGOINGS, MCCB 40 Amps FP (1 Nos), MCB 63 Amps DP (4 Nos), MCB 40Amp DP (2No.), MCB 32Amp DP (2No.), |
| 132 | 12.5 m polygonal hot-dip galvanised high mast, complete with base plate, anchor bolts, head frame and accessories with ring and bend etc completed job |
| 133 | 200 W LED floodlight, IP66, minimum 120–130 lm/W, surge-protected, complete with mounting bracket |
| 134 | SECTION C — FIRE FIGHTING WORKS |
| 135 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe Confirming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 136 | 25 mm dia |
| 137 | 80 mm dia |
| 138 | 100 mm dia |
| 139 | 150 mm dia |
| 140 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked Confirming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 141 | Single headed Gunmetal |
| 142 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel,ISI marked, Confirming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 143 | Single headed Gunmetal |
| 144 | Supplying and fixing orifice plate made out of 6 mm thick Stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 145 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. Confirming to IS 636 (type-A) as required : |
| 146 | Stainless steel |
| 147 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,Confirming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 148 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection Confirming to IS 904 as required : |
| 149 | 2 way - 150 mm dia M.S. Pipe |
| 150 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 151 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle Confirming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 152 | Stainless steel |
| 153 | Providing and fixing Weather proof hose cabinets for internal & yard hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No branch pipe and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitably mounted on a raised masonry platfoRmt as required. (Approx 0.75mx0.6 mx 0.25 m). |
| 154 | Providing and fixing standard fireman's axe with heavy insulated rubber handle Confirming to IS: 926 complete. |
| 155 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal Confirming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, Confirming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads. e)The Pump Flanges Shall be suitable for handling a Pressure of 16 Bar. |
| 156 | 1620 lpm at 56 m Head |
| 157 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following,complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft,mechanical seal Confirming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator,diesel engine Confirming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 158 | 1620 lpm at 56 m Head |
| 159 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following,complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal Confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, Confirming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 160 | 180 lpm at 56 m Head |
| 161 | Fire PanelFabrication, supplying, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and veRmtin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth teRmtinals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Incomings 630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps Outgoings (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump 125 Α, 50ΚΑ ΤΡΝ MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 100 A, 50kA ΤΡΝ MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Diesel Engine Control Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIncomings Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine |
| 162 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets Confirming to IS 13095 of following sizes as required : |
| 163 | 150 mm dia |
| 164 | 100mm dia |
| 165 | 80 mm dia |
| 166 | Providing, installation, testing and commissioning of non-return valve of following sizes confiRmting to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 167 | 150 mm dia |
| 168 | 100mm dia |
| 169 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 170 | 150mm dia |
| 171 | 100 mm dia |
| 172 | 80 mm dia |
| 173 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 174 | Supply, installation, testing & commissioning of Gun Metal Fire brigade suction hose coupling (Draw-out Connection) with nut for female coupling as per IS:902-1974 complete with 100 mm dia. GI suction pipe and 100 mm dia. 1 No. CI foot valve flanged (to be connected to static water tank). |
| 175 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 176 | Providing, installation, testing and commissioning of Pressure Guages |
| 177 | Signage with printed \\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\\" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points. |
| 178 | Floor identification signage ( i.e., GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. |
| 179 | Supplying & laying of 4 core 70 sq mm Aluminum aRmtoured cable from building main panel / transfoRmter to electrical panel for automation of the system. |
| 180 | Supplying & laying of 4 core 6 sq mm heavy duty copper aRmtoured cable from motor to electrical panel for automation of the system. |
| 181 | Supplying & lying of 4 core 16 sq mm heavy duty copper aRmtoured cable from motor to electrical panel for automation of the system. |
| 182 | Supplying Installation, Testing and Commissioning of G.I Earthing Electrode of Size 50 x 3000mm with Gl Pipe Outer Dia. 58 mm (+-) 5%, Length 3000 mm,Inner & Outer Gl Strip Size 32X6mm, TeRmtinal Hole Two Nos., TeRmtinal Hole Dia. 14 mm, Seal Plate Thickness 4 mm, Base Plate Thickness 4 mm, Inner Filling Material - Highly Conductive Super Crystalline Mixture, Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs |
| 183 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ teRmtinating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 184 | Fire Exit signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. |
| 185 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires |
| 186 | FIRE DETECTION (ADDRESSABLE ) |
| 187 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alaRmt panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 188 | Two Loop Panel. |
| 189 | Supplying, installation, testing & commissioning of intelligent analog addressable phototheRmtal detector complete with mounting base complete as required. |
| 190 | Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. |
| 191 | Supplying, installation, testing & commissioning of intelligent addressable theRmtal detector with rate of rise cum fixed temperature theRmtistor complete with base as required. |
| 192 | Manual Call PointSupplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 193 | Hooter Cum StrobeSupplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 194 | Supplying and drawing Fire Resistant flexible/stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. |
| 195 | 2 x 1.5 sq. mm ARmtoured With Outer Sheath in Red Color Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender