Tender For Repair/ Maintenance Of Air Conditioning Plants, Spilt Ac/ Window Acs, Tower Acs, Dg Sets And Its Connected Works At Dmde Area, Sera, Vvr And Ce R&D Area Under Age E/M, Kanchanbagh, Hyderabad.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
21 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Air Conditioning Plants, Spilt Ac/ Window Acs, Tower Acs, Dg Sets And Its Connected Works At Dmde Area, Sera, Vvr And Ce R&D Area Under Age E/M, Kanchanbagh, Hyderabad.
BOQ
| Sl. No. | Item Description |
| 1 | Checking the refrigerant system of window/split type AC of capacity 1.5/2/3/4 ton / tower AC for detecting leaks and arresting the leaks with necessary brazing work after vacuuming the system and recharge the system with refrigerant gas including testing complete all as directed |
| 2 | Supply only refrigerant R-22 / 32 gas including charging to the required pressure for window/split type AC of any capacity and any make complete all as directed. |
| 3 | Supply only refrigerant R-134a/410 gas including charging to the required pressure for water cooler/refrigerator of any capacity and any make complete all as directed. |
| 4 | Taking down unserviceable compressor unit from ACs/watercoolers/ refrigerators by dismantling all electrical/gas connection and S&F new sealed compressor unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing complete all as directed for the following capacities: - |
| 5 | Split/Window type AC of 1.5 ton capacity |
| 6 | Split/Window type AC of 2 ton capacity |
| 7 | Vertical type AC of 3 ton capacity |
| 8 | Split (Cassette type) AC of 3 ton capacity |
| 9 | Split (Cassette type) AC of 4 ton capacity Make for srl item Nos. 4.01 to 4.05 :- Voltas/Carrier/LG/DAIKIN/ as per existing make. |
| 10 | Disconnecting the blower motor from the unit and taking out burnt copper wire from the motor and rewinding the motor with super enamelled copper wire as per existing gauge, varnishing, heating including replacement of existing unserviceable bushes & bearings complete and reconnecting the blower motor to the unit properly, making electrical connection for proper functioning of ACs/ watercoolers / refrigerators /air coolers / tower ACs of following capacity complete all as directed. |
| 11 | Split/Window type AC of 1.5 ton capacity |
| 12 | Split/Window type AC of 2 ton capacity |
| 13 | Vertical type AC of 3 ton capacity |
| 14 | Split (Cassette type) AC of 3 ton capacity |
| 15 | Split (Cassette type) AC of 4 ton capacity |
| 16 | Fresh air outdoor type air handling unit, delivery capacity of 12000 CFMMake for srl item Nos. 5.01 to 5.06 :- AVG/CG/BAJAJ/LG |
| 17 | Taking down unserviceable condensor unit from AC by dismantling all electrical/gas connection and S&F new condensor unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing complete all as directed for the following capacity: - |
| 18 | Split/Window type AC of 1.5 ton capacity |
| 19 | Split/Window type AC of 2 ton capacity |
| 20 | Taking down unserviceable evaporator unit from AC by dismantling all electrical/gas connection and S&F new evaporator unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing complete all as directed for the following capacity: - |
| 21 | Split/ Window type AC of 1.5 ton capacity |
| 22 | Split/Window type AC of 2 ton capacityMake for item Srl No 6.01,6.02,7.01 & 7.02 :- Voltas/ Carrier/ Blue star/ LG/ Daikin/Hitachi |
| 23 | Taking down unserviceable following spare parts from Split / Tower type AC 1.5 to 4 Ton capacity and S&F new spare parts as per existing make and model all as directed |
| 24 | Air filter pad coir |
| 25 | Power circuit board |
| 26 | Remote controlled unit with hand set |
| 27 | Blower motor for fanMake : AUE/CG/Usha/Bajaj |
| 28 | Relay assemblyMake : Sriram/Annapurna/C&S/L&T/ABB/SEIMENS |
| 29 | Over load protectionMake : Sriram/Ranutrol//C&S/L&T |
| 30 | Running capacitor |
| 31 | Starting capacitorMake for srl items Nos.8.07 & 8.08 :- Usha/Universal/ Bhel/ TIBCO/CAPCO |
| 32 | Fan blade assembly |
| 33 | Oscillating motor |
| 34 | Blower with blower housing assembly |
| 35 | S&F flexible cable of size 6 Sqmm 3 core copper conductor multistranded 1100 volts grade, PVC insulated and PVC sheathed of size 6 Sqmm including taking down unserviceable cable complete all as directed. |
| 36 | S&F flexible cable of size 6 Sqmm 4 core copper conductor multistranded 1100 volts grade, PVC insulated and PVC sheathed of size 6 Sqmm including taking down unserviceable cable complete all as directed. Please Enable Macros to View BoQ information |
| 37 | S&F flexible cable of size 6 Sqmm 4 core copper conductor multistranded 1100 volts grade, PVC insulated and PVC sheathed of size 6 Sqmm including taking down unserviceable cable complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender