Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #57640595

Tender For Repair/Maintenance To Flameproof Fittings Cable Tray, Duct Cover And Connected Works At Bhisiana Under Ge (Af) Bhisiana

Issued by Statutory Bodies & Commissions/Committees · Bathinda, Punjab
Tender Value
30.50 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
15 days left
EMD
61000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance To Flameproof Fittings Cable Tray, Duct Cover And Connected Works At Bhisiana Under Ge (Af) Bhisiana

BOQ

Name of Work:- REPAIR/MAINTENANCE TO FLAMEPROOF FITTINGS CABLE TRAY, DUCT COVER AND CONNECTED WORKS AT BHISIANA UNDER GE (AF) BHISIANA
Sl. No. Item Description
1Supply and fixing in replacement of LED tube light fitting, 1 × 20/22 Watt, approximately 1200 mm (4 feet) long, complete with co-extruded polycarbonate (PC) body and diffuser, white acrylic cover, environment-friendly, pre-wired, suitable for 230 V AC, 50 Hz, single-phase supply, complete with LED driver, mounting clips, screws and all standard accessories. The item shall include fixing the fitting in position and making electrical connections using suitable size flexible copper conductor cable from the existing wiring/terminal, testing and commissioning, complete in all respects and following specifications and directed by the Engineer-in-Charge:-(a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
2Supply and fixing of outdoor decorative LED Post Top Lantern luminaire. The housing shall be constructed from heavy-duty spun aluminium / die-cast aluminium combining an integrated high-efficiency thermal management heat sink. Equipped with a high-transmittance, UV-stabilized PMMA (Acrylic) diffuser for glare-free symmetrical light distribution. Complete with a 7W to 10W high-efficiency LED bulb / integrated LED engine, Color Temperature: 4000K, operating on 240V, 50Hz AC supply. System shall have minimum IP65 ingress protection, impact resistance, internal driver, and necessary mounting accessories suited for installation on a pole/post top complete all as specified and as directed by Engineer-in-Charge.
3Taking down carefully existing flame proof point wiring (light/fan point) any type complete with all accessories including steel conduit, junction box, inspection box etc and removing from site and making good disturbed surface of walls/ceiling etc complete all as specified and as directed.
4Material and labour for surface type Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits for light/fan points) complete with 1.5 Sqmm (nominal cross section area) Single Core copper conductor (Flexible) Halogen Free Flame Retardant HFFR compound Insulated Industrial Cables (Unsheathed), 1100 Volt Confirming to IS 17048 for main point and for continues as earth wire connected to earth dolly etc. (Phase, neutral and earth wire) drawn through and including flame proof rigid stove enamelled black ERW conduit suitable nominal dia as required at site but not less than 20 mm nominal dia with all flame proof fittings and accessories i.e. flame proof pipe joint, pipe bend, union, reducer, nipple, pipe hook, inspection elbow, junction box LM6 protection any way, Screws, GI saddles, clamps, connectors etc, including making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note : (i) Rotary switch, Switch Socket and Plug Combined Unit, Flexible conduit, DB and MCB shall be measured and paid separately under appropriate item of BOQ).
5Material and labour for surface type Flame proof Point wiring (using red, black and green colour wires as colour coding for single phase circuits for light/fan points) complete with 2.5 Sqmm (nominal cross section area) Single Core copper conductor (Flexible) Halogen Free Flame Retardant HFFR compound Insulated Industrial Cables (Unsheathed), 1100 Volt Confirming to IS 17048 for main point and for continues as earth wire connected to earth dolly etc. (Phase, neutral and earth wire) drawn through and including flame proof rigid stove enamelled black ERW conduit suitable nominal dia as required at site but not less than 25 mm nominal dia with all flame proof fittings and accessories i.e. flame proof pipe joint, pipe bend, union, reducer, nipple, pipe hook, inspection elbow, junction box LM6 protection any way, Screws, GI saddles, clamps, connectors etc, including making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note : (i) Rotary switch, Switch Socket and Plug Combined Unit, Flexible conduit, DB and MCB shall be measured and paid separately under appropriate item of BOQ).
6Material and labour for supply and fixing on surface of walls/ceilings/floors, as applicable, of 25 mm nominal diameter flameproof rigid stove-enamelled black ERW steel conduit, complete with all necessary and compatible flameproof conduit fittings and accessories, including flameproof pipe joints, bends, unions, reducers, nipples, bushes, inspection/access fittings where required, pipe hooks, GI saddles, clamps, screws, fixing hardware, cutting, threading, bending, alignment etc. The work shall further include taking down and removal of existing/old conduit/pipe complete with fittings, and making good all disturbed surfaces of walls, ceilings and floors with cement mortar (1:3), including finishing to match the adjoining surface, Complete all as specified and as directed by the Engineer-in-Charge.
7Material and labour for supply, laying and drawing-in of 2.5 Sqmm (nominal cross-sectional area) single-core copper conductor, flexible, Halogen Free Flame Retardant (HFFR) compound insulated industrial cable (unsheathed), rated 1100 Volt and conforming to IS 17048, of colour as directed, in existing steel conduit as applicable, including termination and making connections at all points, provision of all necessary lugs, ferrules, sleeves, insulating materials and other accessories required for proper and safe termination, complete all as specified and as directed by the Engineer-in-Charge.
8Material and labour for surface sub main wiring (Three run i.e. 1 x phase and 1 x neutral and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 V grade, conforming to IS 694:2010, drawn through and including 25 mm nominal diameter flameproof rigid stove-enamelled black ERW steel conduit, complete with all necessary and compatible flameproof conduit fittings and accessories, including flameproof pipe joints, bends, unions, reducers, nipples, bushes, inspection/access fittings where required, pipe hooks, GI saddles, clamps, screws, fixing hardware, cutting, threading, bending, alignment etc. The work shall further include taking down and removal of existing/old conduit/pipe with wires and complete with fittings, and making good all disturbed surfaces of walls, ceilings and floors with cement mortar (1:3), including finishing to match the adjoining surface, Complete all as specified and as directed by the Engineer-in-Charge.Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same and cost for conduit fittings shall deemed to be included in the unit rate.
9Supply and Fixing in replacement of a Flameproof (FLP) & Weatherproof (WP) Interlocked Switch Socket and Plug Combined Unit Wall/Structure mounting, specifically designed for hazardous environments, Pressure Die-Cast Aluminum Alloy LM6, 16A, 250V AC, Single Phase, 2 Pole + Earth (2P+E), IP65 or IP66, Zone 1 & 2 (Gas Group IIA & IIB / IIC ), with all necessary accessories, including gland plates and earthing terminals, meeting IS: 2148-2004, CIMFR/PESO Certified for flameproof equipment complete all as specified and as directed.
10Supply and Fixing in replacement of a Flameproof (FLP) Rotary Switch (ON/OFF), specifically designed for hazardous environments, Pressure Die-Cast Aluminum Alloy LM6, 16 Amp, Single Pole (SP), 250V AC, Integrated Flameproof terminal chamber for easy wiring, IP65 or IP66, Zone 1 & 2 (Gas Group IIA & IIB), Compliance with IS: 2148-2004, CIMFR/PESO Certified for flameproof enclosures complete all as specified and as directed.
11Supply and fixing Flameproof flexible metallic hose conduits, heavy-duty, of size 20mm x 300mm long, with male/female brass or stainless-steel connectors (NPT or Metric threads) complete all as specified and as directed.
12Supply and Fixing of flame proof exhaust fans of size 380 mm, single phase 220/240V AC, 50Hz, 1400/1440 RPM, Designed for Hazardous Locations (Zone 1 & 2) with a robust Ex-d flameproof enclosure, Gas Groups IIA & IIB (or IIC), Cast Aluminum Alloy (LM-6), IP-65/65 (dust and water protection), CIMFR/PESO Certified, complete with all other accessories and fixing arrangement (Wall mounting or bracket mounting), fastener etc, making electric connection connecting with and including flexible copper conductor cable FRLSH of suitable size drawn through flexible metalic hose conduit pipe as per site requirement complete all as specified and as directed.Note: Taking down and removing the existing fan, of any type, wherever directed by the Engineer-in-Charge, including handling and depositing the same at the E/M Store Yard of GE (AF) Bhisiana, complete in all respects. Nothing extra shall be paid on this account.
13Supply and fixing in replacement of 2 × 18 W or 2 × 20 W rating LED tube light luminaire, 4 ft length each rod, CMRI/CIMFR-certified and PESO-approved flameproof (Ex-d), weatherproof LED tubular well-glass luminaire, suitable for hazardous areas, conforming to IS/IEC 60079-0:2017 (General Requirements) and IS/IEC 60079-1:2014 (Equipment Protection by Flameproof Enclosures “d”), suitable for Gas/Vapour Group IIA & IIB, Zone 1 & 2, with IP65/66 degree of protection, comprising LM6 die-cast aluminium alloy housing with high-impact, heat-resistant clear borosilicate toughened glass tube protected by heavy-duty SS 304/GI wire guard, suitable for operation on 240 V, 50 Hz AC single-phase supply, with wide-range electronic driver suitable for 150–270 V input and minimum 2 kV surge protection, with power factor not less than 0.95, total harmonic distortion (THD) less than 10%, system luminous efficacy not less than 100 lm/W, CCT 5700–6500 K, CRI greater than 70 and LED life of not less than 50,000 burning hours (L70B50), internally pre-wired and provided with flameproof cable entries/integral terminal chamber with suitable double-compression cable glands, including fixing accessories, making electrical connections with suitable size FRLSH flexible copper conductor cable drawn through flexible metallic hose conduit, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
14Supply and fixing in replacement of 90 W LED flood light luminaire, CMRI/CIMFR-certified and PESO-approved flameproof (Ex-d), suitable for hazardous areas, conforming to IS/IEC 60079-0:2017 (General Requirements) and IS/IEC 60079-1:2014 (Equipment Protection by Flameproof Enclosures “d”), suitable for Gas/Vapour Group IIA & IIB, Zone 1 & 2, with IP65/66 degree of protection, comprising LM6 die-cast aluminium alloy housing with high-impact, heat-resistant clear borosilicate toughened flat glass, suitable for operation on 240 V, 50 Hz AC single-phase supply, with wide-range electronic driver of the same make suitable for 150–270 V input and minimum 10 kV surge protection, with power factor not less than 0.95, total harmonic distortion (THD) less than 10%, system luminous efficacy not less than 100 lm/W, CCT 5700–6500 K, CRI greater than 70 and LED life of not less than 50,000 burning hours (L70B50), internally pre-wired and provided with flameproof cable entries/integral terminal chamber with suitable compression cable glands, including fixing accessories, making electrical connections with suitable size FRLSH flexible copper conductor cable drawn through flexible metallic hose conduit, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
15Supply and fixing in replacement of 40W LED Flameproof Well Glass Luminaire (Bulkhead type) suitable for wall mounted or hanging provision, CMRI/CIMFR-certified and PESO-approved flameproof (Ex-d), suitable for hazardous areas, conforming to IS/IEC 60079-0:2017 (General Requirements) and IS/IEC 60079-1:2014 (Equipment Protection by Flameproof Enclosures “d”), suitable for Gas/Vapour Group IIA & IIB, Zone 1 & 2, with IP65/66 degree of protection, comprising LM6 die-cast aluminium alloy housing epoxy powder-coated with high-impact, heat-resistant clear borosilicate toughened glass dome protected by heavy-duty SS 304/GI wire guard, suitable for operation on 240 V, 50 Hz AC single-phase supply, with wide-range electronic driver suitable for 150–270 V input and minimum 2 kV surge protection, with power factor not less than 0.95, total harmonic distortion (THD) less than 10%, system luminous efficacy not less than 100 lm/W, CCT 5700–6500 K, CRI greater than 70 and LED life of not less than 50,000 burning hours (L70B50), internally pre-wired and provided with flameproof cable entries/integral terminal chamber with suitable double-compression cable glands, including fixing accessories, making electrical connections with suitable size FRLSH flexible copper conductor cable drawn through flexible metallic hose conduit, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
16Supply and fixing in replacement of 8-way SPN, 240 V AC, flameproof (Ex-d), weatherproof distribution board suitable for hazardous areas, suitable for Gas Groups IIA, IIB and IIC, comprising robust die-cast aluminium alloy LM6 enclosure with corrosion-resistant finish, minimum IP65/IP66 degree of protection, conforming to the applicable requirements of IS/IEC 60079-0:2017 and IS/IEC 60079-1:2014, PESO-approved, complete with suitably rated aluminium busbar/ terminals, neutral link, earth terminal, MCB mounting accessories and all necessary fittings, flameproof cable entries with approved flameproof cable glands for incoming and outgoing cables, pre-wired, fixed flush-mounted on wall surface including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge and complete with the following MCBs:- (a) 63 A, single-pole & neutral (SPN) MCB, 10 kA breaking capacity, B-curve, 240 V AC, flameproof/approved for installation within the Ex-d DB — 1 No. (Incoming).(b) 6 A, single-pole MCB, 10 kA breaking capacity, B-curve, 240 V AC, flameproof/approved for installation within the Ex-d DB — 8 Nos. (Outgoing).
17Supply and fixing in replacement of existing LED tube/rod only in flameproof (Ex-d) and weatherproof tubular well-glass luminaire, 4 ft long, 18 W/20 W, suitable for 240 V, 50 Hz AC single-phase supply, energy-efficient LED type, complete with suitable LED driver compatible with the existing flameproof luminaire (i.e. 2X18/2X20), including removal of existing defective tube/rod, supply and fixing of new LED tube/rod, making necessary electrical connections, complete all as specified and as directed by the Engineer-in-Charge.Note: The replacement LED tube/rod shall be suitable for and fully compatible with the existing flameproof luminaire, including its existing lamp-holder/terminal and driver arrangement, without any modification to the flameproof enclosure or impairment of its flameproof integrity. Each LED tube/rod shall be measured and paid separately.
18Supply and fixing in replacement of Lead-Acid Battery, 150 AH, 12 V, suitable for departmental vehicles, including removal of existing unserviceable battery, supply and fixing of new battery of required size complete with copper battery terminals/connectors, including cleaning of battery tray and terminals, proper connection of positive and negative terminals, securing the battery in position, checking battery voltage and charging system, testing and making the vehicle fully serviceable, complete in all respects as specified and directed by the Engineer-in-Charge.
19Supply, installation and commissioning of U-shape perforated cable tray, 450 mm wide × 150 mm high on each side, fabricated from minimum 2.5 mm thick hot-dip galvanized steel sheet, including all required tray accessories and fittings such as cross-overs, bolt-in/snap-in longitudinal partition/barrier strips, supporting corners, horizontal bends, low/rising elbows, T-pieces, edge-protection trims, internal/external couplers, fish-plates, and all required SS/GI nuts, bolts, washers including anti-vibration washers. The cable tray shall be securely fixed in ground ducts, trenches or overhead locations using existing or separately measured and paid structural MS angle/channel supports, as applicable, complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Main structural MS support sections/angles/channels and separate tray covers are excluded from this item and shall be measured and paid separately under the respective BOQ items, wherever required as per site conditions.(ii) All tray fittings and accessories required for a complete and functional installation, other than the separately measured structural supports and tray covers, shall be deemed included in this item.
20Supply, installation and commissioning of U-shape perforated cable tray, 600 mm wide × 150 mm high on each side, fabricated from minimum 2.5 mm thick hot-dip galvanized steel sheet, including all required tray accessories and fittings such as cross-overs, bolt-in/snap-in longitudinal partition/barrier strips, supporting corners, horizontal bends, low/rising elbows, T-pieces, edge-protection trims, internal/external couplers, fish-plates, and all required SS/GI nuts, bolts, washers including anti-vibration washers. The cable tray shall be securely fixed in ground ducts, trenches or overhead locations using existing or separately measured and paid structural MS angle/channel supports, as applicable, complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Main structural MS support sections/angles/channels and separate tray covers are excluded from this item and shall be measured and paid separately under the respective BOQ items, wherever required as per site conditions.(ii) All tray fittings and accessories required for a complete and functional installation, other than the separately measured structural supports and tray covers, shall be deemed included in this item.
21Material and labour for providing and fixing display/safety instruction board of size 1.0 m × 1.0 m, made of 10 mm thick approved acrylic sheet, displaying in capital letters, with suitable photographs/pictorial illustrations, any one of the following as directed by the Engineer-in-Charge: “FIRST AID”, including first-aid instructions; “FIRE SAFETY INSTRUCTIONS”, including methods of operation/use of fire extinguishers; or “SAFETY INSTRUCTIONS IN CASE OF ELECTRIC SHOCK”, including first-aid/rescue procedure and methods of using fire extinguishers, all as per approved sample/design and colour scheme, including necessary lettering, pictorial printing/graphics, border, surface finishing, cutting, drilling and fixing arrangements, including stainless-steel stud fasteners for fixing to the wall, complete all as specified and as directed by the Engineer-in-Charge.
22Supply and laying in replacement of synthetic rubber insulating mat, size 2.0 m × 1.0 m and minimum 2.5 mm thick, red or blue in colour, Class B, having high electrical insulation resistance of not less than 1,000,000 MΩ when tested with a 500 V megger, with non-conductive surface, anti-slip texture, moisture-resistant and resistant to transformer oil, acids, alkalis, diesel and other commonly encountered electrical substation contaminants, suitable for electrical shock protection for voltages up to 11 kV, conforming to IS 15652:2006, including removal of existing mat, cleaning and preparation of the surface, laying the new mat properly flat and all necessary cutting, jointing complete all as specified and as directed by the Engineer-in-Charge.
23Supply and laying in replacement of synthetic rubber insulating mat, size 2.0 m × 1.0 m and minimum 3.5 mm thick, red or blue in colour, Class D, having high electrical insulation resistance of not less than 1,000,000 MΩ when tested with a 500 V megger, with non-conductive surface, anti-slip texture, moisture-resistant and resistant to transformer oil, acids, alkalis, diesel and other commonly encountered electrical substation contaminants, suitable for electrical shock protection for voltages up to 66 kV, conforming to IS 15652:2006, including removal of existing mat, cleaning and preparation of the surface, laying the new mat properly flat and all necessary cutting, jointing complete all as specified and as directed by the Engineer-in-Charge.
24Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles in any description and removing/disposal off from the site to outside MOD land complete all as specified and as directed.
25Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
26Material and labour for 15mm thick cement plastering/ rendering in cement mortar (1:4) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed.
27Material and labour for preparation of new steel and iron surfaces of any description, not otherwise described, exceeding 10 cm in width or girth, including cleaning the surface free from dust, dirt, grease, oil and other foreign matter and surface imperfections by rubbing down with emery paper/sand paper or by other approved means to obtain a clean, smooth and even surface and further applying one coat of red oxide zinc chromate primer and two coats of first-quality synthetic enamel paint of approved brand, shade and tint, each coat applied by brush only after proper preparation and complete drying of the preceding coat, to produce a smooth, uniform, durable and aesthetically acceptable finish, complete in all respects as specified and directed by the Engineer-in-Charge.
28Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns, basement slab etc. complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ.
29Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in walls, retaining walls, and the like; any thickness; above top of footings; complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ.
30Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to better rough finished flat complete all as specified & directed by Engineer-in- charge.
31Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter rough finished complete all as specified and as directed.
32Material and labour for mild steel TMT bars, grade Fe 500D/550D, 10mm dia & over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
33Material and labour for mild steel round bar, 10mm dia and over Grade E250 (Fe 410W), Quality A, cut to length bent to Shape required for lifting handles of RCC drain cover of drain complete all as specified and as directed.
34Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including removing debries/rubbish material from site to outside MOD land complete all as specified and as directed.
35Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and as directed.
36Material and labour for PCC (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in coping, mud stops, packing sides/around of interlocking tiles, kerbs & similar work etc at ground and normal height including weatherings, slightly rounded or chamfered angles and including necessary form work as required etc. complete all as specified and as directed.
37Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed
38Dismantling steel work of any description like supports to cable tray, sunshades/chajjas, parking sheds, cooler stand, grills, grating, walk ways, railings, frame work of water tanks, framed work of motor pump, doors, gates and similar work etc but excluding framed truss etc. complete all as specified and as directed.
39Material and labour for mild steel framed work comprising grills, gratings, drain cover, walkways, railing, supports to cable tray and other similar works, etc fabricated from angles, tees, square bar, expanded metals or other rolled steel sections, round bars, stiffeners and other connecting plates, conforming to Grade 290.Gde-E-165. The work shall include cutting, bending, notching, coping, drilling, punching, shaping, edge preparation, welding, grinding of welds, fabrication, shop assembly, transportation, erection, alignment and fixing in position with approved holding-down bolts, anchor fasteners, nuts, bolts, washers and all necessary fixing accessories. The item shall include all labour, materials, welding electrodes, gas cutting, scaffolding, staging, lifting arrangements, tools and plant, consumables, safety measures and all incidental works necessary for satisfactory completion of the work at all locations, complete in all respects, as specified and directed by the Engineer-in-Charge.
40Excavation in trenches (Manual), not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations of shafts, wells, cess pits, manholes, pipe line, cable in trenches etc., not exceeding 10 Sqm on plan and getting out in any type of soft including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed.
41Excavation over area (Manual), not exceeding 1.5 metre deep and getting out in soft/loose soil complete all as specified.
42Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed.
43Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
44Removing excavated material (surplus soil) to a distance exceeding 50 m but not exceeding 250 mand depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
45Demolition of cement concrete reinforced of any description such as cover slab of manhole, septic tank, roof slab and like, including reinforcement cut as required to facilitate demolition and prepare the surface to casting/jointing new, including removing debries/rubbish material from site to outside MOD land complete all as specified and as directed. Please Enable Macros to View BoQ information
46Demolition of cement concrete reinforced of any description such as cover slab of manhole, septic tank, roof slab and like, including reinforcement cut as required to facilitate demolition and prepare the surface to casting/jointing new, including removing debries/rubbish material from site to outside MOD land complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57640595
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30.50 Lakhs
LAST DATE 13-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance To Flameproof Fittings Cable Tray, Duct Cover And Connected Works At Bhisiana Under Ge (Af) Bhisiana
Basic Detail
Tender No GE/BHI/TOKEN-64/2026-27
Bidding Type Tender
Location
City Bathinda
State Punjab
Key Dates
Publish Date 22 Sep 2026
Submission Date 13 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 30.50 Lakhs
Tender Fee 500
EMD 61000
Exemption Available
Document List
766637a9-cc44-4d82-8a0c-f6da0a3db91f.html
BOQ_886249.xls
TenderDocToken64.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

766637a9-cc44-4d82-8a0c-f6da0a3db91f.html

xls

BOQ_886249.xls

pdf

TenderDocToken64.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders