Power Government Departments Closing in 0 days TDR #57639998

Tender For Supply, Installation, Testing and Commissioning Works For Augmentation Of Sub Stations For Critically Overloaded Dts For Winter Preparedness For Various Divisions Of Kpdcl Falling Under The Jurisdiction Of P&Ao Kpdcl Sopore ( Ed Sumbal Par

Issued by Government Departments · Ganderbal, Jammu and Kashmir
Tender Value
14.50 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
0 days left
EMD
29000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing and Commissioning Works For Augmentation Of Sub Stations For Critically Overloaded Dts For Winter Preparedness For Various Divisions Of Kpdcl Falling Under The Jurisdiction Of P&Ao Kpdcl Sopore ( Ed Sumbal Part ) Ut Capex 2026-27

BOQ

Name of Work:- SITC works for Augmentation of Sub Stations for critically overloaded DTs for Winter Preparedness for various Divisions of KPDCL falling under the jurisdiction of P&AO KPDCL Sopore ( ED Sumbal part ) UT Capex 2026-27
Sl. No. Item Description
1Augmentation of 100 kVA to 200 kVA Sub Station at MIR ABAD NAW ABDI MOHALLA SAFAPORA
2Sub Station Part
3SITC of 200 kVA 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer))
4SITC of 9 Mtr. Long Pole,ST-410 SP33) including pit excuavation 1/6th of pole height
5SITC of Galvanized Nuts & Bolts.
6SITC of GI Channel Cross arms (100X50X6 mm) and (75X40X6 mm) including transformer Belting, Clamps etc. fabricated out of Galvanised steel of different sizes to be fixed with G.I Nuts and bolts and washers.
7SITC of Earthing of Sub-Station - Excavation of earth Pit of 650 mm dia. & depth 3000 mm,Installation of earthing Pipe of 40 mm nominal bore and 4 mm wall thickness and length 2.5 m long as per IS-1239.GI strip for neutral earthing of size 25mm x 3mm for connection of X-mer body,G.O set & LA as per IS-2629/85,Gi nuts and bolts refilled with earth enhancement materials & earth Chamber made of Brick masonary with RCC Slab Cover.
8SITC of 11kV Gapeless Surge Arrestor ,9 kV,10 kA,LA with polymer housing station type with all accessories.
9SITC of 11 kV G.O AB Switch 3-Phase,3-Pole of Capacity 200A Vertical type with arrangements for pad locks and operating rod. The operating rod should be G.I Pipe (B Class) of 25 mm dia of requisite length.
10SITC of LT Distribution Box for: 200 kVA DTR with 315 MCCB 3P 16 kA for incomer & 160Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.
11SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
12SITC of 11 kV Horn Gape 3-phase Fuse set of capacity 200 A with all accessories.
13SITC of 11 kV Polymeric composite Disc insulator 12 kV,minimum failing load of 45 kN,lighting impulse of 75 kV positive & 80 kV negative and with creepage distance of 320 mm.
14SITC of PVC Cable 240 mmSq. Including Al thimbles and SL Clamps (as per latest specifications & drawings adopted and approved by the department).
15Providing and Laying of Cement Bottoming 1:2:4 mix as per REC standards 0.48cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 550X550X 1650mm for 9 ST poles (410,SP-33 ) (the leftover pit after concreting to be filled with soil and boulders).
16SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm
17SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
18SITC of GI Barbed wire for Anti Climbing
19SITC of Danger Plates with Clamps
20SITC of Red-Oxide for painting of Poles
21SITC of Aluminium paint for painting of Poles
22SITC of 0.05 ACSR Conductor (Rabbit).
23SITC of GI Mukhee Clamps with LT Shackle insulators made out of 50x8mm GI Flat
24Augmentation of 100 to 200 kVA Sub Station at DON Mohalla SK Bala
25Sub Station Part
26SITC of 200 kVA 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer))
27SITC of 9 Mtr. Long Pole,ST-410 SP33) including pit excuavation 1/6th of pole height
28SITC of Galvanized Nuts & Bolts.
29SITC of GI Channel Cross arms (100X50X6 mm) and (75X40X6 mm) including transformer Belting, Clamps etc. fabricated out of Galvanised steel of different sizes to be fixed with G.I Nuts and bolts and washers.
30SITC of Earthing of Sub-Station - Excavation of earth Pit of 650 mm dia. & depth 3000 mm,Installation of earthing Pipe of 40 mm nominal bore and 4 mm wall thickness and length 2.5 m long as per IS-1239.GI strip for neutral earthing of size 25mm x 3mm for connection of X-mer body,G.O set & LA as per IS-2629/85,Gi nuts and bolts refilled with earth enhancement materials & earth Chamber made of Brick masonary with RCC Slab Cover.
31SITC of 11kV Gapeless Surge Arrestor ,9 kV,10 kA,LA with polymer housing station type with all accessories.
32SITC of 11 kV G.O AB Switch 3-Phase,3-Pole of Capacity 200A Vertical type with arrangements for pad locks and operating rod. The operating rod should be G.I Pipe (B Class) of 25 mm dia of requisite length.
33SITC of LT Distribution Box for: 200 kVA DTR with 315 MCCB 3P 16 kA for incomer & 160Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.
34SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
35SITC of 11 kV Horn Gape 3-phase Fuse set of capacity 200 A with all accessories.
36SITC of 11 kV Polymeric composite Disc insulator 12 kV,minimum failing load of 45 kN,lighting impulse of 75 kV positive & 80 kV negative and with creepage distance of 320 mm.
37SITC of PVC Cable 240 mmSq. Including Al thimbles and SL Clamps (as per latest specifications & drawings adopted and approved by the department).
38Providing and Laying of Cement Bottoming 1:2:4 mix as per REC standards 0.48cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 550X550X 1650mm for 9 ST poles (410,SP-33 ) (the leftover pit after concreting to be filled with soil and boulders).
39SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm
40SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
41SITC of GI Barbed wire for Anti Climbing
42SITC of Danger Plates with Clamps
43SITC of Red-Oxide for painting of Poles
44SITC of Aluminium paint for painting of Poles
45LT Part
46SITC of ST Poles 8 Mtr long (410-SP-15).including pit excuavation 1/6th of pole height
47SITC of 0.05 ACSR Conductor (Rabbit).
48SITC of GI Mukhee Clamps with LT Shackle insulators including Nuts and Bolts
49SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm
50SITC of Red-Oxide for painting of Poles
51SITC of Aluminium paint for painting of Poles
52Providing and laying of Cement Bottoming 1:2:4 mix as per REC standards 0 .40 cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 500X500X 1650mm 8 Mtr ST poles (410,SP-15) (the leftover pit after concreting to be filled with soil and boulders).
53SITC of Anti-Climbing Device with Clamps
54Augmentation of 63 kVA to 100 kVA Sub Station Khanday Mohalla Banyari
55Sub Station Part
56ITC of 100 kVA 11/0.433kV, 3-phase Distribution Transformers spared from Augmentation of 100 to 200 kVA Sub Station at DON Mohalla SK Bala . The job includes carriage of trannsformer and commissioning along with SITC of SL Clamps of approprote size.
57SITC of 9 Mtr. Long Pole,ST-410 SP33) including pit excuavation 1/6th of pole height
58SITC of Galvanized Nuts & Bolts.
59SITC of GI Channel Cross arms (100X50X6 mm) and (75X40X6 mm) including transformer Belting, Clamps etc. fabricated out of Galvanised steel of different sizes to be fixed with G.I Nuts and bolts and washers.
60SITC of Earthing of Sub-Station - Excavation of earth Pit of 650 mm dia. & depth 3000 mm,Installation of earthing Pipe of 40 mm nominal bore and 4 mm wall thickness and length 2.5 m long as per IS-1239.GI strip for neutral earthing of size 25mm x 3mm for connection of X-mer body,G.O set & LA as per IS-2629/85,Gi nuts and bolts refilled with earth enhancement materials & earth Chamber made of Brick masonary with RCC Slab Cover.
61SITC of 11kV Gapeless Surge Arrestor ,9 kV,10 kA,LA with polymer housing station type with all accessories.
62SITC of 11 kV G.O AB Switch 3-Phase,3-Pole of Capacity 200A Vertical type with arrangements for pad locks and operating rod. The operating rod should be G.I Pipe (B Class) of 25 mm dia of requisite length.
63SITC of LT Distribution Box for: 100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
64SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
65SITC of 11 kV Horn Gape 3-phase Fuse set of capacity 200 A with all accessories.
66SITC of 11 kV Polymeric composite Disc insulator 12 kV,minimum failing load of 45 kN,lighting impulse of 75 kV positive & 80 kV negative and with creepage distance of 320 mm.
67SITC of PVC Cable 185 mmSq. Including Al thimbles and SL Clamps (as per latest specifications & drawings adopted and approved by the department).
68Providing and Laying of Cement Bottoming 1:2:4 mix as per REC standards 0.48cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 550X550X 1650mm for 9 ST poles (410,SP-33 ) (the leftover pit after concreting to be filled with soil and boulders).
69SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm
70SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
71SITC of GI Barbed wire for Anti Climbing
72SITC of Danger Plates with Clamps
73SITC of Red-Oxide for painting of Poles
74SITC of Aluminium paint for painting of Poles
75LT Part
76SITC of ST Poles 8 Mtr long (410-SP-15).including pit excuavation 1/6th of pole height
77SITC of 0.05 ACSR Conductor (Rabbit).
78SITC of GI U Clamps with LT Shackle insulators (GI U Clamps to be fixed with out drilling/punching of poles).
79SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm
80SITC of Red-Oxide for painting of Poles
81SITC of Aluminium paint for painting of Poles
82Providing and laying of Cement Bottoming 1:2:4 mix as per REC standards 0 .40 cum/pole including muffing 15 cm above ground level plaster and curing of concrete in size of 500X500X 1650mm 8 Mtr ST poles (410,SP-15) (the leftover pit after concreting to be filled with soil and boulders).
83SITC of Anti-Climbing Device with Clamps
84RED material etc
85Dismentalling and returning of all red material to divisional workshop /store including Red transformers including transportations of all above works
86Geo tag pics before , during and after completion of all above works Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57639998
AUTHORITY Government Departments
TENDER VALUE 14.50 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Power Development Department
Work Description Tender for Supply, Installation, Testing and Commissioning Works For Augmentation Of Sub Stations For Critically Overloaded Dts For Winter Preparedness For Various Divisions Of Kpdcl Falling Under The Jurisdiction Of P&Ao Kpdcl Sopore ( Ed Sumbal Part ) Ut Capex 2026-27
Basic Detail
Tender No EDSbl 17 of 2026-27
Bidding Type Tender
Location
City Ganderbal
State Jammu and Kashmir
Key Dates
Publish Date 22 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 14.50 Lakhs
Tender Fee 1000
EMD 29000
Exemption Available
Document List
BOQ_1100647.xls
Drawings.pdf
fc961bcd-7185-47df-8bdd-2f59dcd7d535.html
SBD17.pdf
Specifications.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1100647.xls

pdf

Drawings.pdf

html

fc961bcd-7185-47df-8bdd-2f59dcd7d535.html

pdf

SBD17.pdf

pdf

Specifications.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders