Tender For Activity Based Maintenance Contract Of Ohe And Psi For 90 Tkm Main Line & Depot Ohe, 37 Station Ass & 2 Depot Ass, 2 Rss, 2 Tss And 23 Switching Stations Of Nagpur Metro Rail Project Of Maha-Metro For 1 Year Extendable Up To 1 Year.
Tender Overview
Project Description
Tender for Activity Based Maintenance Contract Of Ohe And Psi For 90 Tkm Main Line & Depot Ohe, 37 Station Ass & 2 Depot Ass, 2 Rss, 2 Tss And 23 Switching Stations Of Nagpur Metro Rail Project Of Maha-Metro For 1 Year Extendable Up To 1 Year.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Sep-2026 | PreBid Link | Other | 19-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Maharashtra Metro Rail Corporation Limited, Nagpur Name of Work : Activity based Maintenance Contract of OHE and PSI for 90 TKM Main Line & Depot OHE, 37 Station ASS & 2 Depot ASS, 2 RSS, 2 TSS and 23 Switching stations of Nagpur Metro Rail Project of Maha-Metro for 1 year extendable up to 1 year. Contract No : N1-O&M (OHE&PSI)-65/2026 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description Item Code / Make Quantity Schedules Estimated Amount (including 18% GST) Select Excess (+) / Less (-) Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Quoted Percentage to be entered by Bidder Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Quoted Amount Quoted Amountincluding GST (Rs.) Quoted AmountIn Wordsincluding GST (Rs.) |
| 2 | Preventive Maintenance for Over Head Equipment (FOCS) (Department OHE) |
| 3 | Corrective/Breakdown Maintenance for Over Head Equipment (FOCS OHE)(Department OHE) |
| 4 | Tools,Plants & Consumables(Department OHE) |
| 5 | Preventive Maintenance for PSI(Department PSI) |
| 6 | Corrective/Breakdown Maintenance for PSI (RSS,ASS & Switching station) & Miscellaneous(Department PSI) |
| 7 | Tools,Plants & Consumables(Department PSI) |
| 8 | OEM Service support (GIS, AIS, SCADA)(Department PSI) |
| 9 | Manning of RSS & TSS(Department PSI) |
| 10 | Miscellaneous Items(Department PSI) Total in Figures 29403779.26 29403779.26 INR Two Crore Ninety Four Lakh Three Thousand Seven Hundred & Seventy Nine and Paise Twenty Six Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Two Crore Ninety Four Lakh Three Thousand Seven Hundred & Seventy Nine and Paise Twenty Six Only Schedule 1: Preventive Maintenance for OHE Annexure-2 SN Description of Work Unit Total Qty.of Assets Maint. Freq Total Qty.of Assets (One Year) Unit rate Total Amount (Rs.) A Preventive Maintenance for Over Head Equipment (FOCS OHE) A.1 Cantilever assembly,OHE Structure,Portal, TTU, DA, contact wire diameter checking and allied OHE SPS and structures.Checking of steel components, anchors, nuts, bolts, pins, spring washers, and locknuts for tightness and condition. Inspection of cantilever parts for corrosion, with rust removal and zinc coating wherever required. Verification of split pins, hard spots, flashing marks, steady arm alignment, and insulator cleanliness (ST, BT, and 9-tonne anchor insulators). Measurement and recording of contact wire height and stagger. Inspection of catenary for twists, bulging, and strand breakage, with splicing where strand damage exceeds permissible limits. Checking of nut-bolt tightness at catenary and contact wire supports,Portals and verification of dropper clamp tightness and dropper condition. Refer maintenance checklist for details. Nos. 2630.0 2 Yrly 1315.0 603.0 792945.0 A.2 FOCS Catenary system (Contact wire, catenary wire, droppers,jumper etc.)Measurement of contact wire diameter at high-wear locations and inspection of catenary wire for strand breakage, with splicing where breakage exceeds permissible limits. Cleaning of overheated conductors using emery paper. Inspection of wear-prone locations including support points, curves, section insulators, splices, turnouts, IOLs, tunnel approaches, overline structures, and pull-offs. Verification of contact wire condition for kinks, twists, height, and gradient. Checking of droppers for verticality, tightness, damage, and rubbing at multi-cantilever locations, with replacement or rectification wherever required.Refer maintenance checklist for details per TKM 90.0 Half Yrly 180.0 3619.0 651420.0 A.3 All type of 25 KV OHE feeding Jumpers (FOCS).; Inspection of conductors for broken/damaged strands, overheating and corrosion, particularly at LA, PTs,cross feeders, feeding supply and BM connections. Checking of jumper and PG clamp tightness. Verification of jumper condition, with replacement of frayed/damaged jumpers and rectification of any kinks observed.Refer maintenance checklist for details Nos. 122.0 Yrly 122.0 584.0 71248.0 A.4 Anti Creep Centre (ACC), Anti Creep Anchor (ACA) and Fix Termination Anchor (FTA) arrangement.Inspection of anti-creep wire for strand breakages, Double Messenger Suspension Clamp tightness, and 9-tonne anchor insulator condition, cleanliness, flashing, chipping, and skirt damage. Checking of nut-bolt tightness, availability of pins in anchor bolts and guy rods, and inspection of anchor bolts for rusting with application of anti-rust coating as required. Refer maintenance checklist for details Nos. 252.0 2 Yrly 126.0 1459.0 183834.0 A.5 All type Section Insulator Assembly. Cleaning of PTFE and 9-tonne cut-in insulators. Checking and correction of section insulator alignment, runner condition, nut-bolt and split-pin tightness, and pantograph gliding. Measurement of contact wire diameter, height, stagger and runner gap. Inspection of feeding jumper, stiffeners, PG clamps, flash marks, and broken strands.Refer maintenance checklist for details Nos. 66.0 Half Yrly 132.0 3619.0 477708.0 A.6 Overlaps (insulated and uninsulated). Measurement of OHE height and stagger in overlap sections. Checking of clearance between OHEs, contact wire parallelism length, and correctness of run OHE lifting using pantograph. Inspection of jumper, PG clamp, and RRA clamp tightness, ensuring compliance with prescribed overlap and operational requirements. Refer maintenance checklist for details No. 66.0 2 Yrly 33.0 1459.0 48147.0 A.7 OHE Cross over & Turnouts. Measurement of contact wire height and stagger at mainline and turnout OHE. Checking of pantograph gliding, hard spots, bracket plumb, registration tube alignment, steady arm dip, and take-off values at turnout/crossover locations. Verification of prescribed height difference and stagger limits, with corrective action wherever required. Refer maintenance checklist for details Nos. 85.0 Yrly 85.0 3619.0 307615.0 A.8 Spring Type & BW Auto tension Device (ATD).Checking of ATD fitting assembly nut-bolt tightness, pointer position with respect to temperature as per OEM chart, SS rope strand condition, equalizing plate position, and 9-tonne adjuster condition. Verification of split-pin availability in guy rods and rectification of any deficiencies observed.Checking of steel cable position and condition, pulley alignment, counterweight movement, and tightness of nuts, bolts, and V-pins. Greasing of ball bearings, verification of anti-slip clamp/bolt tightness, cleaning of 9-tonne anchor insulator, and checking of compensating/equalizing plate position.Refer maintenance checklist for details Nos. 210.0 Yrly 210.0 1809.0 379890.0 A.9 RCS Cantilever assembly & Drop Tube. Ensure proper tightness of Nut bolts,intactness of wiring, pins, alignment, cleanliness, and defect rectification.Refer maintenance checklist for details Nos. 60.0 2 Yrly 30.0 362.0 10860.0 A.10 All type Isolators for Maintenance of depot and Mainline.Checking of number plate cleanliness and tightness, operating rod alignment, contacts, arcing horns, and earth continuity. Verification of manual/auto isolator operation and interlocks. Lubrication of moving parts and locks. Measurement and adjustment of male-female contact gap in open position. Cleaning of feeding cable terminations where applicable.Refer maintenance checklist for details No 34.0 Yrly 34.0 1459.0 49606.0 A.11 Maintenance of ITL (Integral Transverse Link including BEC, plinth jumpers, sement jumpers, pier jumpers and all type of bonds etc.). Checking of tightness and corrosion of all ITL nuts and bolts. Inspection of ITL connections, including CAD-welded rail earthing cables, PG clamps, BEC, OPC connections, I/C cable lugs, and conductor strands for damage or breakage. Verification of ITL mounting pedestal condition and integrity. Refer maintenance checklist for details Nos. 180.0 Yrly 180.0 486.0 87480.0 A.12 Earthing System testing with its whitewash/painting & value writing (Depot).Checking of earth electrode nut-bolt tightness and replacement of corroded fasteners. Measurement and verification of individual earth electrode resistance, ensuring values do not exceed 10 ohms. Recording and marking of measured earth resistance values on the respective earth pits. Refer maintenance checklist for details Nos. 113.0 Yrly 113.0 443.0 50059.0 A.13 All type of board/number plate. Checking of nut-bolt tightness for all type boards. Inspection of boards and number plates for cleanliness, corrosion, damage, fading, and legibility. Verification of reflective surfaces, where applicable, to ensure proper visibility and effectiveness under low-light conditions.Refer maintenance checklist for details Nos. 1784.0 2 Yrly 892.0 55.0 49060.0 A.14 Foot Patrolling for OHE. Inspection of foundations for cracks, damage, settlement, tilting, water accumulation, and cleanliness. Checking of mast/portal alignment, impact damage, base plate bolts, lock arrangements, guy rods, anchor bolts, split pins, and corrosion. Verification of insulator condition, ATD pointer position, anti-slip rope integrity, equalizing plate terminations, droppers, jumpers, contact and catenary wires, including wear, sag, hog, and out-of-range conditions. Inspection of post insulators, isolators, control boxes, contacts, sparking signs, and number plates. Checking of earthing and bonding connections among OPC, BEC, masts, piers, DA, steel structures, handrails, fire water pipes, and ITLs. Verification of cable dressing, cable condition, and joints. Inspection of caution boards, DA protective screens, vegetation clearance, bird nests, stray wires, kites, and foreign materials near OHE. Recording of minor defects rectified during patrolling and major defects observed. Refer maintenance checklist for details per TKM 90.0 Monthly 1080.0 362.0 390960.0 A.15 Transportation vehicle including driver & all Fuel charges 24x7 per month services upto 2000 K.M. for one year (Camper/Yoddha), including all maint charges. Per Month 12.0 95241.0 1142892.0 Total Amount of Schedule 1 4693724.0 Schedule 2: Breakdown/Corrective Maintenance for OHE (BOQ) SN Description of Work Unit Total Qty.of Assets (One Year) Unit rate Total Amount (Rs.) Breakdown/Corrective Maintenance for Over Head Equipment (FOCS OHE). B.1 Breakdown attention by a gang for restoration of 25 KV OHE/PSI during accidents/unusual occurrence for checking OHE parameters. Breakdown attention gang shall be a part of CM/PM maintenance team. Nos. 1.0 15045.0 15045.0 B.2 Panto entanglement due to OHE componenet like Turn out,Overlap,non OHE zone,Jumper,Dropper, Cantilever steady arm & other componenet of Cantilever,Section insulator Foreign Material etc. Nos. 1.0 11002.0 11002.0 B.3 Replacement / Re-erection of Single bracket assembly Cantilever Nos. 4.0 5609.0 22436.0 B.4 Replacement / Re-erection Spring types of ATD (including loading & unloading) Nos. 1.0 68794.0 68794.0 B.5 Erection of Catenary wire splicing or Contact wire splicing. Nos. 2.0 15045.0 30090.0 B.6 Replacement / Re-erection of various types of insulators Nos. 4.0 5501.0 22004.0 B.7 Replacement / Re-erection of Section Insulator (double rod type) Nos. 1.0 22227.0 22227.0 B.8 Splicing of Over Head Conductor (OPC) Nos. 4.0 4153.0 16612.0 B.9 CAD Weld from ITL (Integral Transverse Link) to Rail. Nos. 4.0 7061.0 28244.0 B.10 Reconditioning of Earth pit with material as & when required Nos. 68.0 1392.0 94656.0 B.11 Stenciling on OHE Structure with Material Nos. 100.0 384.0 38400.0 B.12 Repaire of Discharge rod without material Nos. 100.0 94.0 9400.0 B.13 Supply & erection of all type boards Nos. 10.0 1262.0 12620.0 B.14 Rectification of Leaning Mast in Mainline & Depot Area with Material Nos. 1.0 9360.0 9360.0 B.15 Supervisor (Highly Skilled) - As required Mandays 120.0 1181.0 141720.0 B.16 Technician (Skilled) - As required Mandays 230.0 1089.0 250470.0 Total Amount of Schedule 2 793080.0 Schedule-3 Spares Tools & Consumables SN Description of Work Unit Total Qty. Unit rate Total Amount (Rs.) C.1 5 Tone Tirfer with rope & handle Nos. 2.0 31275.0 62550.0 C.2 3 Tone Tirfer with rope & handle Nos. 4.0 22627.0 90508.0 C.3 1.5 Tone Tirfer with rope & handle Nos. 4.0 17881.0 71524.0 C.4 0.75 Tone Tirfer with rope & handle Nos. 2.0 12524.0 25048.0 C.5 3 Tone Pull Lift Nos. 2.0 6875.0 13750.0 C.6 1.5 Tone Pull Lift Nos. 4.0 7400.0 29600.0 C.7 0.75 Tone Pull Lift Nos. 4.0 6050.0 24200.0 C.8 Wire Rope Sling(12mm) 1m. Nos. 6.0 335.0 2010.0 C.9 Wire Rope Sling(16mm) 1.5m. Nos. 6.0 710.0 4260.0 C.10 \\"D\\" Shackle 30mm Nos. 6.0 315.0 1890.0 C.11 \\"D\\" Shackle 25mm Nos. 6.0 185.0 1110.0 C.12 \\"D\\" Shackle 20mm Nos. 6.0 155.0 930.0 C.13 \\"D\\" Shackle 16mm Nos. 6.0 113.0 678.0 C.14 \\"D\\" Shackle 12mm Nos. 6.0 71.0 426.0 C.15 Come Along Clamp CW Nos. 4.0 2260.0 9040.0 C.16 Come Along Clamp MW Nos. 4.0 2260.0 9040.0 C.17 Come Along Clamp OPC Nos. 2.0 2280.0 4560.0 C.18 PG Clamp 1031-2 Nos. 20.0 450.0 9000.0 C.19 Belt Sling 1m,2m&3m of length capacity 10 ton Nos. 15.0 2500.0 37500.0 C.20 Manila Rope 16mm Nos. 30.0 1694.0 50820.0 C.21 Pulley Single Sleeve 4\\"inch Nos. 4.0 410.0 1640.0 C.22 Pulley Double Sleeve 4\\"inch Nos. 2.0 615.0 1230.0 C.23 Pulley Double Sleeve 6\\"inch Nos. 2.0 910.0 1820.0 C.24 Pulley Single Sleeve 6\\"inch Nos. 4.0 625.0 2500.0 C.25 Safety Belt Nos. 6.0 2710.0 16260.0 C.26 Through Bolt Nos. 4.0 450.0 1800.0 C.27 Binding Wire Bundle (10 kg) Nos. 1.0 1100.0 1100.0 C.28 Measuring tape (15 m) Nos. 2.0 190.0 380.0 C.29 Tree trimming rod Nos. 2.0 6400.0 12800.0 C.30 Hacksaw frame Nos. 2.0 405.0 810.0 C.31 Technician Tool Kit (with list) Nos. 6.0 9300.0 55800.0 Total amount of Schedule 3 544584.0 Total Amount of Schedule 1, 2 & 3(Excl. GST) 6031388.0 Total of Schedule 1,2 & 3(Incl. GST@18%) 7117037.84 Schedule 1: Preventive Maintenance for PSI (BOQ) SN Description of Work Unit Qty of Assets Maint. Frequency Total Qty.of Assets (One Year) Unit rate Total Amount (Rs.) A Section-A:- Preventive Maintenance for PSI (RSS) A.1 Preventive Maintenance of 132/33 kV, 25 MVA Auxiliary Main Transformer and 132/25 kV, 30.24 MVA Traction Transformer along with all associated accessories and auxiliaries including OLTC, RTCC Panel, Marshalling Box, Neutral Grounding Resistor (NGR), Lightning Arresters (LA), Isolators, NIFPS, Cooling System, Protection & Monitoring Devices, Control and Indication Circuits, and associated equipment, comprising inspection, testing, servicing, cleaning, adjustment, calibration, condition monitoring, and performance verification and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 8.0 Qtrly 32.0 7237.0 231584.0 A.2 Preventive Maintenance of 132 kV GIS (Gas Insulated Switchgear) Panel including Circuit Breaker, Disconnectors (Isolators), Earthing Switches, Busbars, Current Transformers (CTs), Voltage Transformers (VTs), SF₆ Gas Monitoring System, Local Control Cabinet (LCC), Protection & Control Circuits, Interlocking System, SCADA Interface, Auxiliary Supply System, and all associated accessories, comprising inspection,servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Bays 18.0 Half Yrly 36.0 1845.0 66420.0 A.3 Preventive Maintenance of 132 kV Control, Relay & Protection (CRP) Panel associated with 132 kV GIS/AIS Substation equipment, including numerical protection relays, control circuits, metering circuits, annunciation system, disturbance recorders, event loggers, SCADA interface, communication equipment, DC supply circuits, interlocking systems, terminal blocks, wiring, and all associated accessories, comprising inspection, testing, servicing, cleaning and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Panel 24.0 Half Yrly 48.0 840.0 40320.0 A.4 Preventive Maintenance of 33 kV/415 V, 400 kVA Dry Type Transformer including complete inspection, testing, servicing, cleaning, adjustment, condition assessment, and performance verification of the transformer and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 4.0 Qtrly 16.0 2918.0 46688.0 A.5 Preventive Maintenance of 33 kV Air Insulated Switchgear (AIS) Panels, including Circuit Breakers, Busbars, Current Transformers (CTs), Potential Transformers (PTs), Isolators, Earthing Switches, Protection & Control Circuits, Relay Panels, Metering Equipment, Annunciation System, Interlocking Arrangements, Auxiliary Supply System, and all associated accessories, comprising inspection, testing, servicing, cleaning, adjustment, lubrication, calibration verification and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist panel 22.0 Half Yrly 44.0 2412.0 106128.0 A.6 Preventive Maintenance of 25 kV Gas Insulated Switchgear (GIS) Panels, including Vacuum/SF₆ Circuit Breakers, Current Transformers (CTs), Potential Transformers (PTs), Disconnectors (Isolators), Earthing Switches, Protection & Control Equipment, Metering System, Interlocking Arrangements, Annunciation System, Auxiliary Supply System, SCADA Interface, and all associated accessories, comprising inspection, servicing, cleaning, adjustment, lubrication, calibration verification, condition monitoring and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Nos. 20.0 Half Yrly 40.0 1459.0 58360.0 A.7 Preventive Maintenance of AC Distribution Board (ACDB) including incoming and outgoing feeders, busbars, MCCBs, ACBs, MCBs, contactors, protection devices, metering instruments, control wiring, indication systems, earthing arrangements, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive Yearly maintenance checklist Nos. 2.0 Yrly 2.0 2217.0 4434.0 A.8 Preventive Maintenance of DC Distribution Board (DCDB) including incoming and outgoing feeders, busbars, MCCBs, ACBs, MCBs, contactors, protection devices, metering instruments, control wiring, indication systems, earthing arrangements, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive yearly maintenance checklist Nos. 2.0 Yrly 2.0 2217.0 4434.0 A.9 Preventive Maintenance of Battery Charger System including inspection, testing, servicing, cleaning, adjustment, and performance verification of the battery charger and associated equipment and to carry out all the activities mentioned in the preventive maintenance Quarterly/Half yearly/Yearly checklist Nos. 6.0 Qtrly 24.0 2217.0 53208.0 A.10 Preventive Maintenance of 450 Ah Battery Bank complete with battery cells, inter-cell connectors, battery stands, battery voltage and current monitoring, DC distribution connections, charger interface, ventilation arrangements, and associated accessories, including inspection, testing, servicing, cleaning, adjustment, performance verification and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 6.0 Qtrly 24.0 1478.0 35472.0 A.11 Preventive Maintenance of 33 kV, 1200 kVAR Shunt Reactor complete with reactor unit, bushings, support insulators, protection and control circuits, marshalling box, neutral grounding arrangement, surge protection devices, earthing system, and associated accessories, including inspection, testing, servicing, cleaning, tightening, adjustment and to carry out all activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 1.0 Qtrly 4.0 7571.0 30284.0 A.12 Preventive Maintenance of 5 kVA Uninterruptible Power Supply (UPS) System including UPS rectifier, inverter, static bypass switch, metering instruments, alarms, protection devices, communication modules, and all associated accessories, comprising inspection, testing, servicing, cleaning and to carry out all activities mentioned in the preventive Half yearly/Yearly maintenance checklist Nos. 2.0 Qtrly 8.0 2100.0 16800.0 A.13 Preventive Maintenance of 225 kVAR Dynamic Reactor Panel including reactor assembly, switching devices, control and protection circuits, capacitor/reactor control equipment, contactors, thyristor switching modules, metering instruments, indication and annunciation systems, auxiliary supply circuits, SCADA interface, earthing system, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening, adjustment and to carry out all the activities mentioned in the preventive Monthly maintenance checklist Nos. 2.0 Monthly 24.0 1596.0 38304.0 A.14 Preventive Maintenance of SCADA (Supervisory Control and Data Acquisition) System, SAS (Substation Automation System), Auxiliary Panels, Networking Panels, Communication Equipment, Servers, Workstations, HMIs, Ethernet Switches, Routers, Fiber Optic Communication Systems, Power Supply Units, interpanel Communication Interfaces, BOCC/OCC interface and all associated hardware and software, including inspection, testing, servicing, cleaning, configuration verification, communication health checks and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 10.0 Qrtly 40.0 672.0 26880.0 A.15 Checking of earthing system with its whitewash/painting & value writing (RSS & TSS) including inspection, testing, maintenance of earth pits, earthing conductors, equipment earthing connections, structure earthing, lightning protection earthing, neutral earthing, fencing earthing, cable tray earthing, and associated grounding network and to carry out all the activities mentioned in the preventive Yearly maintenance checklist Earth Pits 148.0 Yrly 148.0 443.0 65564.0 A.16 Preventive Maintenance of Buried Rail Earthing System installed at Receiving Substations (RSS) and Traction Substations (TSS) including buried rail electrodes, earth grid connections, earthing strips, earth risers, bonding joints, test links, earth pits, equipment earthing interfaces, and associated accessories and to carry out all the activities mentioned in the preventive Yearly maintenance checklist Nos. 4.0 Yrly 4.0 4434.0 17736.0 A.17 Preventive Maintenance of 5 TR (5 Ton Refrigeration) HVAC System installed at RSS, switchgear Room including Indoor Unit, Outdoor Unit, Compressor, Condenser, Evaporator, Refrigerant Circuit, Air Handling Components, Electrical Control Panel, Thermostats, Filters, Drainage System, Control Wiring, Protection Devices, and all associated accessories and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist sets 2.0 Qrtly 8.0 1608.0 12864.0 A.18 Preventive Maintenance of Split Type Air Conditioning Unit complete with indoor unit, outdoor condensing unit, compressor, condenser coil, evaporator coil, blower assembly, refrigerant piping, insulation, drainage system, electrical control panel, thermostat, remote controller, protection devices, and all associated accessories. The work shall include inspection, testing, servicing, cleaning, adjustment, performance evaluation and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 16.0 Qrtly 64.0 2350.0 150400.0 A.19 Preventive Maintenance of 5 Tonne Capacity Electric Overhead Travelling (EOT) Crane complete with brakes, motors, gearboxes, wheels, rails, electrical control panel, limit switches, protection devices, structural members, and all associated accessories and to carry out all the activities mentioned in the preventive yearly maintenance checklist Nos. 2.0 Yrly 2.0 3358.0 6716.0 Total Section A 1012596.0 B Section-B:- Preventive Maintenance for PSI (TSS) B.1 Preventive Maintenance of 33 kV/27.5 kV, 5 MVA Traction Transformer complete with OLTC, RTCC Panel, Marshalling Box, Cooling System, Protection & Monitoring Devices and all associated accessories including inspection,testing, servicing, cleaning, adjustment, calibration, condition assessment, and performance verification and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 4.0 Qrtly 16.0 7237.0 115792.0 B.2 Preventive Maintenance of Control, Relay and Protection (CRP) Panels of 33 kV and 25 kV systems including complete inspection, servicing, cleaning, adjustment, calibration, and performance verification of all protection, control, monitoring, indication, metering, annunciation, communication, and auxiliary circuits and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 7.0 Qrtly 28.0 2223.0 62244.0 B.3 Preventive Maintenance of Battery Charger System including inspection, testing, servicing, cleaning, adjustment, and performance verification of the battery charger and associated equipment and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 4.0 Qtrly 16.0 2217.0 35472.0 B.4 Preventive Maintenance of 200 Ah Battery Bank complete with battery cells, inter-cell connectors, battery stands, battery voltage and current monitoring, DC distribution connections, charger interface, ventilation arrangements, and associated accessories, including inspection, testing, servicing, cleaning, adjustment, performance verification and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 2.0 Qrtly 8.0 4434.0 35472.0 B.5 Preventive Maintenance of AC Distribution Board (ACDB) including incoming and outgoing feeders, busbars, MCCBs, ACBs, MCBs, contactors, protection devices, metering instruments, control wiring, indication systems, earthing arrangements, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive yearly maintenance checklist Nos. 2.0 Yrly 2.0 1109.0 2218.0 B.6 Preventive Maintenance of DC Distribution Board (DCDB) including incoming and outgoing feeders, busbars, MCCBs, ACBs, MCBs, contactors, protection devices, metering instruments, control wiring, indication systems, earthing arrangements, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive yearly maintenance checklist Nos. 2.0 Yrly 2.0 1109.0 2218.0 B.7 Preventive Maintenance of 33 kV Circuit Breakers, 25 kV Circuit Breakers, and Interrupter (BM) installed at RSS, TSS, Switching Stations, and associated power supply installations, including circuit breaker mechanism, interrupter unit, operating mechanism, spring charging system, control and protection circuits, CT/PT circuits, metering circuits, annunciation systems, auxiliary contacts, busbar connections, interlocking systems, and all associated accessories. The work shall include inspection, testing, servicing, cleaning, lubrication, adjustment, functional verification and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 17.0 Qtr 68.0 2223.0 151164.0 B.8 Preventive Maintenance of 33 kV and 25 kV Current Transformers (CT) and Potential Transformers (PT) installed in RSS, TSS, Feeder Bays, Transformer Bays, Bus Coupler Bays, Traction Feeders, Auxiliary Feeders, Metering Panels, Protection Systems, and associated power supply installations. The work shall include inspection, testing, servicing, cleaning, tightening, condition assessment, functional verification, and recording of operational parameters and to carry out all the activities mentioned in the preventive Quarterly/Half Yearly/Yearly maintenance checklist Nos. 58.0 Qtrly 232.0 1112.0 257984.0 B.9 Preventive Maintenance of 25 kV and 33 kV Outdoor Lightning Arresters (LA) installed at Traction Substations (TSS), Feeder Bays, Transformer Bays, Incoming/Outgoing Feeders, Busbars, and associated power supply installations. The work shall include inspection, testing, servicing, cleaning, tightening, condition monitoring, verification of surge counter operation, earthing system checks, and functional assessment of Lightning Arresters and associated accessories and to carry out all the activities mentioned in the preventive Quarterly/Half Yearly/Yearly maintenance checklist Nos. 33.0 Qtrly 132.0 840.0 110880.0 B.10 Preventive Maintenance of 25 kV/230 V, 25 kVA Auxiliary Transformer including complete inspection, testing, servicing, cleaning, adjustment, condition assessment, and performance verification of the transformer and to carry out all the activities mentioned in the preventive Quarterly/Half Yearly/Yearly maintenance checklist Nos. 4.0 Qtrly 16.0 2223.0 35568.0 B.11 Preventive Maintenance of 25 kV and 33 kV Outdoor Isolators installed at Traction Substations (TSS), Feeder Bays, Transformer Bays, Incoming/Outgoing Feeders, Busbars, and associated power supply installations. The work shall include inspection, testing, servicing, cleaning, tightening, condition monitoring, verification of surge counter operation, earthing system checks, and functional assessment of Lightning Arresters and associated accessories and to carry out all the activities mentioned in the preventive Quarterly/Half Yearly/Yearly maintenance checklist Nos. 41.0 Qtrly 164.0 1112.0 182368.0 B.12 Preventive Maintenance of RTUs, Ethernet Switches, Routers, Fiber Optic Communication Systems, Power Supply Units, Communication Interfaces, and all associated hardware and software, including inspection, testing, servicing, cleaning, configuration verification, communication health checks and to carry out all the activities mentioned in the preventive Quarterly/Half Yearly/Yearly maintenance checklist Nos. 2.0 Qtrly 8.0 1523.0 12184.0 Total Section B 1003564.0 C Section-C:- Preventive Maintenance for PSI (Switching station) C.1 Preventive Maintenance of 25 kV Interrupter (BM) installed at Switching Stations, and associated power supply installations, including circuit breaker mechanism, interrupter unit, operating mechanism, spring charging system, control and protection circuits, PT circuits, metering circuits, annunciation systems, auxiliary contacts, busbar connections, interlocking systems, and all associated accessories. The work shall include inspection, testing, servicing, cleaning, lubrication, adjustment, functional verification and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Nos. 71.0 Half Yrly 142.0 2918.0 414356.0 C.2 Preventive Maintenance of 25 kV Potential Transformers (PT) installed at Switchning station, and associated power supply installations. The work shall include inspection, testing, servicing, cleaning, tightening, condition assessment, functional verification, and recording of operational parameters and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Nos. 52.0 Half Yrly 104.0 1459.0 151736.0 C.3 Preventive Maintenance of 25 kV Lightning arrester (LA) installed at Traction Substations (TSS), Feeder Bays, Transformer Bays, Incoming/Outgoing Feeders, Busbars, and associated power supply installations. The work shall include inspection, testing, servicing, cleaning, tightening, condition monitoring, verification of surge counter operation, earthing system checks, and functional assessment of Lightning Arresters and associated accessories and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Nos. 14.0 Half Yrly 28.0 1459.0 40852.0 Total Section C 606944.0 D Section-D:- Preventive Maintenance for PSI (ASS) D.1 Preventive Maintenance of 33 kV/415 V, 400 kVA,1000kVA, 2500kVA Dry Type Transformer including complete inspection, testing, servicing, cleaning, adjustment, condition assessment, and performance verification of the transformer and to carry out all the activities mentioned in the preventive quarterly/Half yearly/Yearly maintenance checklist Nos. 78.0 Qtrly 312.0 2918.0 910416.0 D.2 Preventive Maintenance of 33 kV Air Insulated Switchgear (AIS) Panels, including Circuit Breakers, Busbars, Current Transformers (CTs), Potential Transformers (PTs), Isolators, Earthing Switches, Protection & Control Circuits, Relay Panels, Metering Equipment, Annunciation System, Interlocking Arrangements, Auxiliary Supply System, and all associated accessories, comprising inspection, testing, servicing, cleaning, adjustment, lubrication, calibration verification and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Nos. 240.0 Half Yrly 480.0 2412.0 1157760.0 D.3 Preventive Maintenance of Battery Charger including inspection, testing, servicing, cleaning, adjustment, and performance verification of the battery charger and associated equipment and to carry out all the activities mentioned in the preventive maintenance Quarterly/Half yearly/Yearly checklist Nos. 39.0 Qtrly 156.0 1478.0 230568.0 D.4 Preventive Maintenance of Battery Bank (125Ah, 150Ah & 183Ah) complete with battery cells, inter-cell connectors, battery stands, battery voltage and current monitoring, DC distribution connections, charger interface, ventilation arrangements, and associated accessories, including inspection, testing, servicing, cleaning, adjustment, performance verification and to carry out all the activities mentioned in the preventive Quarterly/Half yearly/Yearly maintenance checklist Nos. 39.0 Qtrly 156.0 1478.0 230568.0 D.5 Preventive Maintenance of AC Distribution Board (ACDB) including incoming and outgoing feeders, busbars, MCCBs, ACBs, MCBs, contactors, protection devices, metering instruments, control wiring, indication systems, earthing arrangements, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive Yearly maintenance checklist Nos. 39.0 Yrly 39.0 1109.0 43251.0 D.6 Preventive Maintenance of DC Distribution Board (DCDB) including incoming and outgoing feeders, busbars, MCCBs, ACBs, MCBs, contactors, protection devices, metering instruments, control wiring, indication systems, earthing arrangements, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening and to carry out all the activities mentioned in the preventive Yearly maintenance checklist Nos. 39.0 Yrly 39.0 1109.0 43251.0 D.7 Preventive Maintenance of Viaduct Lighting, power and control cables and Power sockets including junction box/terminal block (as & when required) Nos. 200.0 Yrly 200.0 443.0 88600.0 D.8 Preventive Maintenance of RTUs, Ethernet Switches, Routers, Fiber Optic Communication Systems, Power Supply Units, Communication Interfaces, and all associated hardware and software, including inspection, testing, servicing, cleaning, configuration verification, communication health checks and to carry out all the activities mentioned in the preventive maintenance checklist Nos. 39.0 Qtrly 156.0 1523.0 237588.0 D.9 Preventive Maintenance of 150 kVAR & 450 kVAR Dynamic Reactor Panel including reactor assembly, switching devices, control and protection circuits, capacitor/reactor control equipment, contactors, thyristor switching modules, metering instruments, indication and annunciation systems, auxiliary supply circuits, SCADA interface, earthing system, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening, adjustment and to carry out all the activities mentioned in the preventive Monthly maintenance checklist Nos. 32.0 Monthly 384.0 1596.0 612864.0 D.10 Preventive Maintenance of Fixed LT Reactor (100 kVAR, 250 kVAR and 300 kVAR) including reactor assembly, switching devices, control and protection circuits, capacitor/reactor control equipment, contactors, metering instruments, indication and annunciation systems, auxiliary supply circuits, SCADA interface, earthing system, and all associated accessories, comprising inspection, testing, servicing, cleaning, tightening, adjustment and to carry out all the activities mentioned in the preventive Monthly maintenance checklist Nos. 21.0 Qtrly 84.0 1679.0 141036.0 D.11 Transportation vehicle including driver & all Fuel charges 24x7 per month services upto 2000 K.M. for one year (Camper/Yoddha), including all maint charges. Month 12.0 95241.0 1142892.0 Total Section D 4838794.0 E Section-E:- Preventive Maintenance for PSI (SCADA system) E.1 Preventive Maintenance of SCADA (Supervisory Control and Data Acquisition) System for OCC including Servers, Workstations, HMIs, Ethernet Switches, Routers, Fiber Optic Communication Systems, Power Supply Units, interpanel Communication Interfaces, RSS/ASS/BOCC interface and all associated hardware and software,printer unit including inspection, testing, servicing, cleaning, configuration verification, communication health checks and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Set 1.0 Half Yrly 2.0 3358.0 6716.0 E.2 Preventive Maintenance of SCADA (Supervisory Control and Data Acquisition) System for BOCC including Servers, Workstations, HMIs, Ethernet Switches, Routers, Fiber Optic Communication Systems, Power Supply Units, interpanel Communication Interfaces, RSS/ASS/OCC interface and all associated hardware and software,printer unit including inspection, testing, servicing, cleaning, configuration verification, communication health checks and to carry out all the activities mentioned in the preventive Half yearly/Yearly maintenance checklist Set 1.0 Half Yrly 2.0 3358.0 6716.0 Total Section E 13432.0 Total of Schedule-1 7475330.0 Schedule 2: Breakdown/Corrective Maintenance for PSI (BOQ) SN Description of Work Unit Total Qty. Unit Rate Total Amount (Rs.) F Section-1 - Breakdown/Corrective Maintenance for PSI (RSS,ASS & Switching station). F.1 Corrective Maintenance for 33 kV and 25 kV Power Cable End Termination Jointing Work at RSS, TSS, ASS, Feeding Posts, and associated power supply installations, including dismantling of damaged/defective cable termination or joint, preparation of cable ends, installation of new termination/jointing kits, testing, commissioning, and restoration of the cable circuit. The termination/jointing kit shall be supplied by Maha-Metro, while the contractor shall provide all required tools, testing instruments, consumables, skilled manpower, and OEM-certified cable jointers authorized for execution of EHV/MV cable termination and jointing works. Nos. 6.0 3078.0 18468.0 F.2 Corrective Maintenance for 33 kV and 25 kV Power Cable Straight Through Jointing Work at RSS, TSS, ASS, Feeding Posts, and associated power supply installations, including dismantling of damaged/defective cable termination or joint, preparation of cable ends, installation of new termination/jointing kits, testing, commissioning, and restoration of the cable circuit. The termination/jointing kit shall be supplied by Maha-Metro, while the contractor shall provide all required tools, testing instruments, consumables, skilled manpower, and OEM-certified cable jointers authorized for execution of EHV/MV cable termination and jointing works. Nos. 6.0 3078.0 18468.0 F.3 Corrective Maintenance for 33 kV and 25 kV Underground Power Cable Joint Preparation Work including location and exposure of faulty cable, excavation, trench preparation, dewatering (if required), provision and installation of HDPE protection pipes, cable handling using suitable machinery, preparation of cable joint pit, sand cushioning, protective covering, backfilling, compaction, route restoration, disposal of surplus excavated material, and all associated civil and electrical activities required for execution of cable jointing/termination work. The termination/jointing kit shall be supplied by Maha-Metro, while the contractor shall provide all required tools, testing instruments, consumables, skilled manpower, and OEM-certified cable jointers authorized for execution of EHV/MV cable termination and jointing works. Nos. 1.0 8336.0 8336.0 F.4 Corrective Maintenance involving replacement of defective, failed, damaged, inaccurate, or malfunctioning 25kV & 33 kV Current Transformers (CT) and Potential Transformers (PT) installed in all types of 25kV & 33 kV HT switchgear panels including AIS Panels, GIS Panels, Feeder Panels, Transformer Panels, Bus Coupler Panels, Capacitor/Reactor Panels, Incoming/Outgoing Feeder Panels, and associated HT equipment. The CT/PT shall be provided by Maha-Metro, whereas the contractor shall provide all required manpower, tools, tackles, testing instruments, consumables, transportation, supervision, and skilled personnel for complete replacement, testing, commissioning, and restoration of the panel Nos. 6.0 3372.0 20232.0 F.5 Corrective Maintenance involving replacement of defective, damaged, failed, deteriorated, flashover-affected, aged, or malfunctioning 25 kV Outdoor Type Lightning Arrester (LA) installed at Traction Substations (TSS), Receiving Substations (RSS), Feeding Posts (SP), Traction Transformer Bays, Feeder Bays, OHE Feeders, and associated traction power supply installations. The Lightning Arrester shall be supplied by Maha-Metro, whereas the contractor shall provide all necessary manpower, supervision, tools and tackles, lifting equipment, testing instruments, consumables, transportation, and skilled personnel for dismantling, installation, testing, commissioning, and restoration of the system, complete in all respects. Nos. 1.0 2928.0 2928.0 F.6 Corrective Maintenance involving replacement of defective, damaged, failed, flashover-affected, aged, inaccurate, oil leakage affected, or malfunctioning 25 kV Outdoor Type Current Transformer (CT) and Potential Transformer (PT) installed at Traction Substations (TSS), Receiving Substations (RSS), Switching Stations, Feeder Bays, Transformer Bays and associated traction power supply installations. The CT/PT shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation, testing, commissioning, and restoration of the equipment complete in all respects. Nos. 1.0 3261.0 3261.0 F.7 Replacement & Laying of 33 & 25kV Cable on Viaduct/Tray. The cable shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation, and restoration of the cable network in all respects. Mtr. 100.0 151.0 15100.0 F.8 Replacement & Laying of 33&25kV Cable at-grade/underground. The cable shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation, and restoration of the cable network in all respects. Mtr. 50.0 606.0 30300.0 F.9 Laying of Control & LT Cable upto 95 Sq.mm.size in ASS, RSS,TSS and on viaduct cable tray. The cable shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation, and restoration of the cable network in all respects. Mtr. 1000.0 47.0 47000.0 F.10 Replacement of 33kV Dry Type Transformer of all capacities (400kVA, 1000kVA & 2500kVA) without machinaries at RSS & ASS. The spare Transformer of required rating shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation, testing, commissioning, and restoration of the equipment complete in all respects. Nos. 1.0 21961.0 21961.0 F.11 Skilled worker (As when required). Man/day 70.0 1089.0 76230.0 F.12 Unskilled workers like loading/unloading shifting of material etc (As when required). Man/day 80.0 893.0 71440.0 F.13 Hire & running charge for mobile crane upto 8 Tonne (As when required) per day 3.0 5099.0 15297.0 F.14 Hire & running charge for crane upto 40 Tonne capacity (As when required) per day 2.0 9037.0 18074.0 F.15 Earth switch assembly rectification work for 33kV AIS panel. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 5.0 3358.0 16790.0 F.16 Attending Oil leakages in Power/Auxiliary Transformers at RSS and TSS. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 1679.0 6716.0 F.17 Attending Oil leakages in CT/PT at RSS and TSS. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 1679.0 6716.0 F.18 Rectification of BM (fail to close/open issue/operation issue) at Switching Post in Line-1 & Line-2 section. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 1679.0 6716.0 F.19 Rectification of Spring charging mechanism (motor and gear assembly) for 33 KV Panels. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 2223.0 8892.0 F.20 Rectification of Mechanical assembly for CB rack in/ rack out for 33 KV Panels in RSS and ASS. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 2223.0 8892.0 F.21 Rectification/Replacement of Mechanical/Electrical control assembly of BM at Switching stations in Line-1 & Line-2 section. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 2223.0 8892.0 F.22 Rectification of 33kV & 25kV Circuit Breaker unit at RSS & TSS. The spare Circuit breakers required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 5.0 2223.0 11115.0 F.23 Replacement of various types of Relays at RSS, TSS and ASS. The spare relay shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 2.0 1135.0 2270.0 F.24 Replacement of Battery cell with its pre-charging and testing. The Battery cell required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 20.0 1135.0 22700.0 F.25 Replacement of Battery charger card. The spare card required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 2.0 840.0 1680.0 F.26 Replacement of Solenoid coil for 33 KV HT panels at RSS and ASS. The spares required shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 2223.0 8892.0 F.27 Replacement of Electrical Equipments including Reactors, ACDB, DCDB, Battery charger etc. at RSS, ASS, TSS with Hydra/Crane arrangement. The spares equipment shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 4.0 5535.0 22140.0 F.28 Replacement of viaduct light at at-grade section/ Viaduct The lights shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. No. 50.0 272.0 13600.0 F.29 Repairing of viaduct lights electrical circuit including repalcement of terminal blocks in junction box (terminal block will be provided by Maha-Metro) No. 100.0 136.0 13600.0 F.30 Repairing of power socket electrical circuit including repair if required in junction box No. 10.0 1089.0 10890.0 F.31 33KV cable end termination jointing work with HDPE pipe installation, excavation and backfilling of underground cable (1 joint of 3 core )(Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) Nos. 2.0 5535.0 11070.0 F.32 HVAC system corrective Maintenance at Jhansi Rani & Sitabuldi RSS- gas topup,leakage checking & attaining, PCB check and its repair if required, compressor circuit repair, and all work related to HVAC for maintaining system healthiness System 1.0 176834.0 176834.0 F.33 Replacement of Lights and power socket system(including all types of lights) at Substations (both RSS & TSS). The light shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. Nos. 50.0 181.0 9050.0 F.34 Replacement of High mast lights at Receiving substation. The light shall be supplied by Maha-Metro, whereas the contractor shall provide all manpower, supervision, lifting arrangements, tools and tackles, testing instruments, consumables, transportation, and skilled personnel required for dismantling, installation and restoration of the system in all respects. Nos. 5.0 840.0 4200.0 F.35 Refilling of Fire supression cylinder used for 33kV HT panel & Dry type Transformer with 6 kg clean agent (FK 5112 or equivalent gas) along with High pressure testing of cylinder before refilling and submission of report Nos. 5.0 15500.0 77500.0 F.36 Refilling of Fire supression cylinder used for Battery charger and other Electrical equipments at RSS with 2.5kg /3kg clean agent (FK 5112 or equivalent gas) along with High pressure testing of cylinder before refilling and submission of report Nos. 2.0 7750.0 15500.0 F.37 Dismantaling and reinstallation of Fire supression cylinder used for 33kV HT panel, Dry type Transformer, Battery charger and other electrical equipments along with any other accessories required for its rectification Nos. 7.0 5000.0 35000.0 F.38 Supply and installation of Multilayer special tube for 33kV HT panel from OEM/authorized dealer Mtr. 25.0 900.0 22500.0 F.39 132kV cable patrolling from Mankapur Grid Subsation to Jhansi rani RSS to Sitabuldi RSS (10km total cable length)- contractor staff has to check the complete cable route and if any activity observed on cable route, he has to immediately report to Maha-Metro incharge and contractor staff has to check that due to such activity if any damage to cable then he need to immediately terminate the activity in the vicinity of cable. Days 365.0 546.0 199290.0 Total Amount of Schedule 2 (Excl. GST) 1088540.0 Schedule-3 Spares Tools & Consumables Section G: List of Minor Tools SN Description of Item Unit Total Qty. Unit Rate Total Amount (Rs.) G.1 DE spanner set of 12 pieces - 6mm to 32mm (6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 21x23, 24x27, 25x28, 30x32) Nos. 2.0 2246.0 4492.0 G.2 Ring spanner set of 12 pieces - 6mm to 32mm (6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 21x23, 24x27, 25x28, 30x32) Nos. 2.0 2246.0 4492.0 G.3 Set of Screwdriver set ( size 4\\", 6\\", 8\\",10\\") Nos. 4.0 212.0 848.0 G.4 Adjustable pipe wrench 12\\" Nos. 4.0 299.0 1196.0 G.5 Drill Machine ( Portable) (Bosch) with hammer set Nos. 1.0 4899.0 4899.0 G.6 Ball pin Hammer Nos. 4.0 195.0 780.0 G.7 Hack saw frome adjustable (6\\" to 12\\") complete with handle Nos. 4.0 184.0 736.0 G.8 Insulated Noseplier 8\\" Nos. 4.0 310.0 1240.0 G.9 Insulated combination plier 8\\" Nos. 4.0 210.0 840.0 G.10 Bench vise 150mm Nos. 2.0 3259.0 6518.0 G.11 File 200mm Smooth flat Nos. 4.0 488.0 1952.0 G.12 File Half round 200 mm (bastard) Nos. 4.0 531.0 2124.0 G.13 Grease Gun Nos. 4.0 1172.0 4688.0 G.14 D' Shackle 20 mm Nos. 5.0 155.0 775.0 G.15 D' Shackle 16 mm Nos. 4.0 113.0 452.0 G.16 Pressure Oil Can Nos. 4.0 150.0 600.0 G.17 Screw Driver set Taparia no. 831 Nos. 4.0 252.0 1008.0 G.18 Hexogonal socket set 11 pieces with acessories (Taparia make) Nos. 2.0 3349.0 6698.0 G.19 Pulley Double Sleeve 6\\"inch Nos. 4.0 910.0 3640.0 G.20 Pulley Single Sleeve 6\\"inch Nos. 4.0 625.0 2500.0 G.21 Tirfor- 1.5tonn Nos. 1.0 17881.0 17881.0 G.22 Tirfor- 3tonn Nos. 1.0 22627.0 22627.0 G.23 Wire Rope Sling(12mm) 1m. Nos. 4.0 335.0 1340.0 G.24 Wire Rope Sling(16mm) 1.5m. Nos. 4.0 710.0 2840.0 G.25 Multi-Meter (fluke) 1 Nos/ team 2.0 4270.0 8540.0 G.26 Clamp meter (1A & 1000A) (Fluke) Nos. 2.0 13309.0 26618.0 G.27 Earth tester 3 terminal (Digital) Nos. 1.0 109901.0 109901.0 G.28 Insulation tester (500V, 2.5kV, 5kV) (Metrel) Nos. 2.0 133620.0 267240.0 G.29 Blowers (Bosch) Nos. 4.0 2699.0 10796.0 G.30 Vacuum cleaner Nos. 2.0 5000.0 10000.0 G.31 Richet (size 6 to 32 ) (Bosch) Set 2.0 5598.0 11196.0 G.32 Torque wrench (100Nm) nos 2.0 4500.0 9000.0 G.33 LED Torchlight Nos 4.0 1700.0 6800.0 G.34 Junction box (200m-15A) Nos 4.0 1000.0 4000.0 G.35 Crimping tool Nos 4.0 1000.0 4000.0 G.36 Tool box Nos. 2.0 6800.0 13600.0 G.37 Hand held drill machine Nos. 2.0 6700.0 13400.0 G.38 Aluminium Ladder Nos. 4.0 4500.0 18000.0 G.39 Hydraulic crimping tool Nos. 1.0 10000.0 10000.0 G.40 Hand Gloves 2 Nos. each 40.0 15.0 600.0 G.41 First aid box (Plantex) 1 Nos. each 5.0 1000.0 5000.0 G.42 Hydrometer, rubber gloves, funnel 1 Nos. each 2.0 2000.0 4000.0 G.43 Fibre glass tape 1 Nos. each 6.0 400.0 2400.0 Total of List of Minor Tools & Plant 630257.0 Section H: List of Consumables PSI SN Description of Item Unit Total Qty. Unit Rate Total Amount (Rs.) H.1 Cotton Cloth kg 30.0 100.0 3000.0 H.2 HT Tape(33 kv) (JONSON) Mtr 2.0 1300.0 2600.0 H.3 Silica Gel kg 50.0 250.0 12500.0 H.4 M-Seal(PIDILITE) no 4.0 30.0 120.0 H.5 Anabound no 5.0 170.0 850.0 H.6 Anti Track Paint spray(SPEZET) no 5.0 240.0 1200.0 H.7 Enamel Paint [Red,Yellow,Green,Black(1 kg can each),(ASIANPAINT) kg 4.0 270.0 1080.0 H.8 Touch up Paint Spray (400 ml)(Siemens grey)(CUBE) kg 6.0 240.0 1440.0 H.9 Insulating Tape (PVC tape)(STEELGRIP) no 10.0 20.0 200.0 H.10 Cells (1.5 V)(DURACELL) no 15.0 25.0 375.0 H.11 9 V Batteries for multimeter/ clampmeter (DURACELL) 5.0 235.0 1175.0 H.12 Hydrometer((MEGA) no 4.0 279.0 1116.0 H.13 Paint Brush [25 mm](ASIANPAINT) no 10.0 40.0 400.0 H.14 Paint Brush [50 mm](ASIANPAINT) no 10.0 60.0 600.0 H.15 Petroleum jelly(PURENSO) kg 2.0 1000.0 2000.0 H.16 Rust Cleaner spray(WD-40) no 10.0 325.0 3250.0 H.17 contact cleaner spray(WD-40) no 4.0 325.0 1300.0 H.18 Cold Galvanised(ZRC) no 5.0 400.0 2000.0 H.19 Oil leakage arresting Sealant (Putty) no 2.0 800.0 1600.0 H.20 Teflon Tape(SUPREME) no 5.0 20.0 100.0 H.21 Grease(SKF) kg 2.0 800.0 1600.0 H.22 Lubricant Oil(CASTROL) litre 1.0 400.0 400.0 H.23 Testing clips for eqiuipments no 10.0 25.0 250.0 H.24 Snake repellant (Carbolic acid bottles) no 4.0 600.0 2400.0 H.25 Distilled water for Batteries(HORSE) litre 100.0 25.0 2500.0 H.26 Emry Paper (Red, 0 number) no 20.0 10.0 200.0 H.27 Emry Paper (Black, 0 number) no 20.0 10.0 200.0 H.28 Sanitizer(DETTOL) litre 10.0 500.0 5000.0 H.29 Disinfectant spray(DETTOL) litre 6.0 720.0 4320.0 H.30 Anti weed material(LEQUIED WEEDISIDE- KATYAYANI) litre 4.0 1041.0 4164.0 Total of Consumables 57940.0 Total of Schedule 3 (Tools, Plants & Consumables) 688197.0 Schedule-4 OEM support for various system at RSS & ASS SN Description of Work Unit Total Qty. Unit rate Total Amount (Rs.) I.1 Provision of OEM service support in case of major failures in 132kV GIS system (5 days of Expert charges including To & Fro and accomodation and Rental Charges for SF6 gas analyzer for 5 days) LS 1.0 1530165.0 1530165.0 I.2 Provision of AMC of SCADA system at 2 RSS for 1 year including 12 mandays of Expert visit, To and fro charges of 2 visit and their lodging and boarding charges mandays 1.0 743400.0 743400.0 I.3 Breakdown maintenance of SCADA system at RSS/BOCC/OCC including emergency visit of SCADA Expert for 1 manday visit at RSS/OCC/BOCC, to and fro charges and their lodging and boarding charges Nos. 2.0 74450.0 148900.0 I.4 Provision of AMC of SCADA system at OCC and BOCC for 1 year including 6+6 mandays of Expert visit, To and fro charges of 2 visit and their lodging and boarding charges Nos. 1.0 773400.0 773400.0 I.5 Provision of OEM service support in case of major failures in 25kV GIS system (3 mandays of Expert chargs for breakdown rectification work) (Total 20 nos. of GIS panel installations at 2 RSS) Panel (LS) 1.0 337777.0 337777.0 I.6 Provision of OEM service support in case of major failures in 33kV AIS of M/s. Siemens ( Panel (LS) 1.0 200802.0 200802.0 I.7 Provision of OEM service support in case of major failures in 33kV AIS of M/s. Sterling Generators Panel (LS) 1.0 18840.0 18840.0 I.8 Provision of OEM service support in case of major failures in Battery Charger of M/s. Amara Raja Make for 1 mandays service charges including Trouble shooting, repairing, Checking & Testing of theequipment, (If any material is required for clearing the faults in battery charger maha-Metro will providethe necessary spare for clearing the fault) Panel (LS) 1.0 32272.0 32272.0 I.9 Provision of OEM service support in case of major failures in UPS of M/s. Power one Make Panel (LS) 1.0 71715.0 71715.0 Other Miscellaneous I.10 Transformer Oil Testing preferably from NABL accrediated lab sample 12.0 16296.0 195552.0 I.11 Calibration of testing equipment’s:Winding resistance meter Nos. 1.0 12359.0 12359.0 Total of Schedule-4 4065182.0 Schedule 5: Manning at RSS & TSS A Description of Work Unit Total Qty. Unit rate Total Amount (Rs.) J.1 Deployement of skilled manpower for manning in three shifts for 2 nos. RSS and 2 nos. TSS mandays 4380.0 1089.0 4769820.0 4380.0 Total of Scheduled-5 4769820.0 1088.5008 4767633.504 Schedule 6: Miscellaneous Items. SN Description of Work Unit Total Qty. Unit rate Total Amount (Rs.) K.1 Miscellaneous items and payment shall be made as per actual expenditure incurred. Lumsump 1.0 800000.0 800000.0 Total Amount of Section-2 (Excl. GST) 800000.0 Total Amount of Schedule-6 Total Amount of Schedule 1,2 ,3, 4 ,5 & 6 (Excl. GST) 18887069.0 Total of Schedule 1,2, 3, 4 ,5 & 6(Incl. GST@18%) 22286741.42 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 18 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender