Tender For special Repair To Internal Wiring With Connected Works At Ncc Dte (Ap & T) Under Age E/M (S) Of Ge (S) Secunderabad
Tender Value
23.67 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
20 days left
EMD
47500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Internal Wiring With Connected Works At Ncc Dte (Ap & T) Under Age E/M (S) Of Ge (S) Secunderabad
BOQ
| Sl. No. | Item Description |
| 1 | M & L for taking down copper/aluminium point wiring (light, fan, socket, power, security lights or bulkhead) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed |
| 2 | Taking down existing unserviceable Distribution boards / AC board with MCB's any size and any type complete all as specified and as directed. |
| 3 | M & L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FR-LSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories surface in wall / ceiling including continous earth wire 1.5 Sqmm PVC insulated FR-LSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in walls and modular white plate covers with frame for mounting of modular switches/sockets etc complete including making good of disturbed surfaces of wall / ceiling / floor all complete as specified and directed(a) onelight point/ ceiling /exhaust fan point/bell point |
| 4 | (b) One three pin switch socket 6 Amps outlet on independent board. complete all as specified and as directed |
| 5 | (c) One three pin switch socket 6 Amps outlet on same board. complete all as specified and as directed |
| 6 | All as per item No 3 here in before but with cable 2.5 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed |
| 7 | All as per item No 3 here in before but with cable 4 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for socket out let 15 amps and AC box including continuous earth wire PVC insulated 4 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified |
| 8 | S & F in repair Modular switch 1 way 6A , 1-module complete all as specified and directed |
| 9 | S & F in repair Modular switch 1 way 16A with indicator, 1-module complete all as specified and directed |
| 10 | S & F in repair Modular bell push 1 way 6A with indicator, 1-module complete all as specified and directed. |
| 11 | S & F in repair Modular socket, shuttered type, 6A - 3 pin 2 -module complete all as specified and directed. |
| 12 | S & F in repair Modular socket, shuttered type, 6/16A - combined 2-module complete all as specified and directed |
| 13 | S & F 3 pin, 6 A, 250 V ceiling rose having terminal capacity 3 X 1.5 mm² IP 20 protection complete all as specified and directed |
| 14 | M&L of Bells Ding dong AC 230Volts Single pole complete all as specified and as directed. |
| 15 | S & F lamp holder any angle suitable for LED Bulbs insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and as directed |
| 16 | S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) incl taking down old one and deposited to MES store complete all as specified and directed |
| 17 | S & F exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep incl taking down old one and deposited to MES store complete all as specified and directed |
| 18 | S & F 20 W surface / wall mounted LED batten input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cupper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed |
| 19 | S&F LED batten light fitting10 Watts 2 feet surface / wall mounted efficacy not less than 100 Lumen/Watt rated life 25000 burning hours complete all as specified and directed |
| 20 | S & F recess mounting LED down light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow,efficacy 120 lumen/watts rated life 50000 burning hours suitable for false ceiling pop/grid ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and as directed. |
| 21 | S & F surface mounting light fitting with new LED down light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for True ceiling rated life 50,000 burning hours including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . |
| 22 | S & F LED security light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect as specified and directed by engineer-in-charge.complete all respect as specified and directed |
| 23 | S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) all as specified and as directed. |
| 24 | S & F TPN DB 8 way double door vertical load line with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed . |
| 25 | S&F in replacement MCCBs 415V, 16KA, 125 amps 4 Pole suitable for DB complete all as specified & directed |
| 26 | S&F of sheet metal enclosure TPN DBs with 200 Amps rated bus bar of 4 way 415 volts with blank plate complete with double door complete all as specified and directed. |
| 27 | S & F single pole & neutral, double door, metallic distribution board 8 ways conforming to IEC 61439-3, suitable for flush / surface mounting complete all as specified and directed |
| 28 | S&F MCB single phase and neutral (SPN), 40 Amps, 230 Volts, connecting with lugs, complete all as specified and directed |
| 29 | S&F MCB SP 6 to 32 Amps 'C' series complete all specified and directed. |
| 30 | S&F MCB, single pole, 63 Amps, 240 Volts, connecting with copper lugs complete all as specified and directed |
| 31 | S&F of MCB three phase and neutral (TPN), 100 Amps, 415 Volts, connecting with lugs, complete all as specified and directed |
| 32 | M & L for Submain concealed/ surface wiring with 2 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note:-(1) The wiring shall be done in proper colour coding using red,yellow,blue for phases , black for neutral and green for earth(2) The three runs of copper wire one run of PVC coduit is shall be measured as one running meter. |
| 33 | M & L for Submain concealed/surface wiring with 4 runs of single core 10sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 10 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note:-(1) The wiring shall be done in proper colour coding using red,yellow,blue for phases , black for neutral and green for earth(2) The three runs of copper wire one run of PVC coduit is shall be measured as one running meter. |
| 34 | S&f GI Perforated cable try size 300mm x 50mm with 16 SWG for fixing of cable conduit pipes incl suitable fastners etc for fixing arrangment complete all as all as specified and as directed. |
| 35 | M & L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete incl taking down old one all as specified and as directed. |
| 36 | M&L for earth continuity conductor 4 Sq.mm dia GI or steel wire complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
TodayOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender